Power supply CP-C 24/5.0

Similar documents
Redundancy unit CP-A RU

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-C 24/5.0

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Electronic timer CT-ERS.21

Electronic timer CT-AHD.22

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

STEP-PS/1AC/24DC/1.75

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Messaging module CP-C MM

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2007

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TRIO-DIODE/12-24DC/2X10/1X20

QUINT-PS-3x AC/24DC/10

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply HARTING pcon

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Three-phase monitoring relay

QUINT-BUFFER/24DC/24DC/40

Power Supply HARTING pcon

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

QUINT-PS AC/24DC/10

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Contact protection relay

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Rhino PSM Power Supplies. Operating Instructions

QUINT-PS/24DC/48DC/ 5

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Industrial Power Supplies

Redundancy Module QUINT-DIODE/40

ASI QUINT /2.4 EFD

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

QUINT-PS/ 1AC/24DC/20/CO

PMT. PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A. Highlights & Features. Safety Standards. Model Number: General Description

DC541 Digital Input/Output Module

Output Voltage* (nom.)(adjustable)

AO523 Analog Input Module

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Thermistor motor protection relay CM-MSS.21

AI531 Analog Input Module

PMT. Safety Standards. Model Number:

AO561 Analog Output Module

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

AI561 Analog Input Module

DC522 Digital Input/Output Module

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Industrial Power Supplies

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

DC561, digital input/output module,

Output Voltage* (nom.)(adjustable)

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

Thermistor motor protection relay CM-MSS.11

Industrial Power Supplies

Transcription:

2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous short-circuit proof Power reserve up to 50 % High efficiency of typ. 88-89 % Low power dissipation and low heating Pluggable double connecting terminals Integrated input fuse Parallel operation for increased capacity and redundancy Power factor correction EN 61000-3-2 Function modules pluggable onto the front side LED for status indication CP-C 24/5.0 Output terminals: L+, L- Input terminals: L, N and PE OUTPUT OK: green LED - operating state indication Adjustment of the output voltage by potentiometer Schematic circuit digram Approvals 508 1), UL 60950 1),, CB scheme 1) pending: 1604 (Class I, Div. 2), 1) Marks, Ordering data Type Supply voltage Output Order code CP-C 24/5.0 85-264 V AC / 22-28 V / 5 A 1SVR 427 024 R0000 100-350 V DC Ordering data - Accessories Type Description Order code CP-C MM Indication and remote-off module 1SVR 427 081 R0000 Details see data sheet 2CDC 114 014 D0201 Application The primary switch mode power supply CP-C 24/5.0 has two voltage inputs. This enables the supply with AC or DC. Furthermore the CP-C 24/5.0 is equipped with two generous capacitors, which ensure mains buffering of at least 100 ms. That is why the devices can be used worldwide also in high fluctuating networks and battery-powered plants. Due to their reliable construction, the devices can be used in very harsh industrial environments. The power reserve of up to 50 % enables trouble-free starting of heavy loads, so that no oversized power supply is needed. 1) Approvals refere to the rated input voltage V IN 1

Operating mode - parallel operation Power supply CP-C 24/5.0 In order to increase capacity and to enable redundancy, up to 5 devices can be connected in parallel. For a symmetric distribution it is advisable to execute the line connections with the same cross sections and same lengths. Parallel operation, increased capacity For n parallel connected devices, the output current can be increased to n x I OUT. It is advisable to use parallel connection if a power supply unit does not cover the current requirement of the most powerful consumer. Otherwise the consumers should be spread among individual devices independent of one other. Parallel operation, redundancy Redundant circuits are suitable to increase the operational reliability in case of errors. If a fault occurs in the first power supply circuit (called initial fault), the power supply of all consumers will be taken over by the second, redundant supply circuit. For this reason the power supply units to be connected in parallel are dimensioned in such a way that the total current requirement of all consumers can be completely covered by one power supply unit. 2CDC 272 024 F0004 2CDC 272 025 F0004 Operating mode - Output and temperature curves The switch mode power supply CP-C 24/5.0 is able to supply at 24 V DC output voltage and at an ambient temperature of 40 C a continuous output current of approx. 7.25 A 60 C the rated current of 5 A At ambient temperatures of: > 60 C the output power has to be reduced by 2,5 % per Celvin temperature increase. > 70 C i.e. thermal overload, the device will switch-off. If the switch mode power supply is loaded with an output current > 7.25 A, the operating point is passing through the V/I characteristic curve shown below. V out [V] I out [A] I out [A] 2CDC 272 026 F0004 T a [ C] 2CDC 272 006 F0004 Output curve at T a = 25 C 2CDC 273 046 F0004 Temperature curve at V out = 24 V Operation mode - Adjustable output voltage The CP-C 24/5.0 features an continuously adjustable output voltage from 22-28 V DC. Thus they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. 2

Operating mode - Pluggable function module CP-C MM The messaging module CP-C MM indicates the correct function of the power supply unit via LEDs and energized output relay. Furthermore the power supply unit can be switched off by closing of a volt-free contact at the REMOTE OFF input. If the supply voltage at the input of the power supply falls below 82 V AC (70 V DC), the corresponding output relay INPUT OK (contacts 11-12/14) is de-energized and the LED INPUT OK turns off. If the output voltage OUTPUT of the power supply falls below 19,8 V DC, the corresponding output relay OUTPUT OK (contacts 21-22/24) Installation Mounting The switch mode power supply can be snapped on a DIN rail according to EN 50022 as shown in the accompanying picture. For that the device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. 2CDC 272 012 F0004 2CDC 272 076 F0004 2CDC 272 013 F0004 Demounting Remove the switch mode power supply as shown in the accompanying picture. For that the latching lever is pulled downwards by means of the screwdriver. Then the device can be unhinged from the mounting rail edge and removed. Mounting position The devices have to be mounted horizontally with the input terminals on the bottom. In order to ensure a sufficient convection, the minimum distance to other modules must not be less than 80 mm in vertical direction and 10 mm in horizontal direction. Electrical connection of primary and secondary side Connect the input terminals L and N. The protective earth conductor PE must be connected. Actuate plug connector only when power is off. The installation must be executed EN 60950, provide a suitable disconnecting device (e. g. line protection switch) in the supply line. The input side is protected by an internal input fuse. Rate the lines for the maximum output current or provide a separate fuse protection. We recommend to choose the cable section as large as possible in order to minimize voltage drops. Observe the polarity. Actuate plug connector only when power is off. The device is overload, short-circuit and open-circuit proof. The secondary side of the power supply is electrically isolated from the input and internally not earthed (SELV) and can therefore be earthed by the user according to the needs with L+ or L- (PELV). 3

Position of connection terminals L+ L+ L- L- Power supply CP-C 24/5.0 L N PE PWM L+ L- L N PE 2CDC 272 014 F0004 L, N Supply voltage PE Protective earth conductor L+, L- Output voltage Safety instructions and warnings The device must be installed by qualified persons only and in accordance with the specific national regulations (e. g. VDE, etc.). The CP-C 24/5.0 is a chassis-mounted unit. It is maintenance-free and does not contain any integral setting elements and should therefore not be opend. Before any installation, maintenance or modification work: Disconnect the system from the supply network and protect against switching on! Before start of operation the following must be ensured: Connect to main according to the specific national regulations for class of protection I. Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the end product to disengage unit and supply cables from supply mains if required. The protective earth conductor must be connected to the terminal PE. Rate the output lines for the output current of the power supply and connect them with the correct polarity. In order to ensure sufficient air-cooling the distance to the other devices has to be considered. Screws at the enclosure are for internal grounding. Do not remove them! Do not connect cable! Attention! Improper installation/operation may impair safety and cause operational difficulties or destruction of the unit. In operation pay attention to: Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)! (Dis)connect the plug connector only when the power is off. Risk of burns: Depending on the operation conditions the enclosure can become very hot. If the internal fuse blows, most probably the device is defect. In this case, an examination of the switch mode power supply Attention! Danger to life! Disconnect the system from the supply network before executing any works at the device and protect against switching on! The power supply contains components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit and do not open the unit. With some units of this range the output is capable of providing hazardous energy. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. 4

Technical data Data at T a = 25 C, V IN = 230 V AC and nominal values, if nothing else indicated Input circuit L, N Rated input voltage V IN 110-240 V AC Input voltage range AC 85-264 V AC DC 100-350 V DC (if V > 264 V DC, use additionally an appropriate external fuse) Frequency range AC 47-63 Hz DC 0 Hz Current consumption I IN at 110-240 V AC ca. 2.2-1.2 A Power consumption typ. 135 W Inrush current / I 2 t (cold start) < 23 A / approx. 0.9 A 2 s Power failure buffering at nom. load typ. > 100 ms Starting time after applying supply voltage typ. < 100 ms Transient overvoltage protection Varistors Internal input fuse 4 A slow-acting (apparatus protection, not accessible) Discharge current for PE < 3.5 ma Output circuit L+, L+, L-, L- short-circuit, no-load and overload proof Rated output voltage V OUT 24 V DC Tolerance of the output voltage -1... +5 % Adjustment range of the output voltage 22-28 V DC, default setting 24 V DC 0,5 % Rated output power P OUT 120 W Rated output current I OUT T a < 60 C 5 A Peak output current I OUTmax (power reserve) T a < 40 C typ. 7.25 A Derating 60 C < T a < 70 C 2.5 % per Celvin temperature increase Deviation with load change 10-90 % statical typ. < 0.05 % dynamical typ. < 3 % control time typ. < 1 ms change of the input voltage of 10 % typ. < 0.05 % Response time T OUT 10-90 % at P NOM typ. < 30 ms Residual ripple and switching peaks 20 MHz typ. < 50 mv PP Parallel connection yes, up to 5 devices, to enable redundancy and to increase capacity, current not symmetrical Series connection to increase voltage yes, for decoupling Resistance to reverse feed yes, limited to approx. 35 V DC Power factor correction (PFC) yes Indication of operational states OUTPUT OK: green LED Overload performance see V/I and I/T curves Short circuit continuation with current limitation Current limitation at short circuit approx. 11 A Short circuit protection continuous short circuit stability Overload protection thermal protection Starting of capacitive loads unlimited General data Power dissipation typ. < 15 W Efficiency > 88 % MTBF 500.000 h Dimensions W x H x D 56.25 x 126 x 130 mm 5

Technical data (continued) General data (continued) Weight approx. 0.96 kg / 2.11 lb Minimum distance to other units horizontal 10 mm vertical 80 mm Degree of protection enclosure IP 20 terminals IP 20 Material of enclosure enclosure shell aluminium cover zinc-coated sheet steel Protection class EN 61140 1 Mounting DIN rail (EN 50022), snap-on mounting Mounting position horizontal Electrical connection - Input circuit pluggable connecting terminals, actuate only when power is off Wire size fine-strand with wire end ferrule 0.2-2.5 mm 2 ( 22-14 AWG) without wire end ferrule 0.2-2.5 mm 2 ( 22-14 AWG) rigid 0.2-2.5 mm 2 ( 22-14 AWG) Stripping length 7 mm (0.27 inches) Torque 0.4 Nm Electrical connection - Output circuit pluggable connecting terminals, actuate only when power is off Wire size fine-strand with wire end ferrule 0.12-2.5 mm 2 ( 26-14 AWG) without wire end ferrule 0.12-2.5 mm 2 ( 26-14 AWG) rigid 0.12-2.5 mm 2 ( 26-14 AWG) Stripping length 8 mm (0.315 inches) Torque 0.4 Nm Environmental data Temperature range operation -25...+70 C full load 0...+60 C (without derating) storage -40...+85 C Humidity IEC 60068-2-3 93 % at +40 C, no condensation Pollution degree EN 50178 2 Climatic category EN 60721 3K3 Vibration IEC 68-2-6 1-57 Hz, amplitude 0.075 mm 57-100 Hz, 5 g Shock IEC 68-2-27 30 g all directions Isolation data Insulation voltage input / output 3 kv AC (type test), 1.2 kv AC (routine test) input / PE 1.5 kv AC (type test), 1.2 kv AC (routine test) output / PE 350 V AC (routine test) Standards Product standard EN 61204 Low Voltage Directive 73/23/EEC EMC Directive 89/336/EEC Electrical safety EN 50178, EN 60950, UL 60950, UL 508 Protective low voltage SELV (EN 60950) 6

Technical data (continued) Approvals / marks Approvals existing culus 508 1), curus 1), GOST, CB scheme 1) pending UL 1604 (Class I, Div. 2), CCC 1) Marks CE, C-Tick Electromagnetic compatibility Interference immunity EN 61000-6-2 electrostatic discharge (ESD) electromagnetic field fast transients (Burst) powerful impulses (Surge) HF line emission EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 N 61000-4-5 N 61000-4-6 level 4-8 kv / 15 kv level 3-10 V/m level 4-4 kv level 4-2 kv symmetrical, level 3-3 kv unsymmetrical level 3-10 V Interference emission EN 61000-6-3 HF line emission EN 55022 class B electromagnetic field EN 55022 class B 1) Approvals refer to the rated input voltage V IN Dimensions in mm 2CDC 272 068 F0004 7

Publication No. 2CDC 114 011 D0202 - Issue 05.2005 ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Postfach 10 16 80 69006 Heidelberg, Germany Internet www.abb.com E-Mail epr-support@stotzkontakt.de