Manual Supplement. Manual Title: 1760 Users Supplement Issue: 5 Print Date: June 2006 Issue Date: 2/18 Revision/Date: 2, 5/10 Page Count: 5

Similar documents
Manual Supplement. Manual Title: 1760 Users Supplement Issue: 4 Print Date: June 2006 Issue Date: 5/14 Revision/Date: 2, 5/10 Page Count: 4

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

Circuit Breaker Analyzer & Timer CAT31

MAJOR VA Power Inverter

PQA823 PQA824 Rel /09/12

GPS Synchronization Module

power quality Models 8230 & 8220

Circuit Breaker Analyzer & Timer CAT65

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 2 Print Date February 2012 Date: 2/13 Revision/Date: 1 Page Count: 18

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Programmable Relay ZEN V2 Units

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

BVS Series Battery Voltage Supervisor

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 1 Print Date February 2012 Date: 6/12 Revision/Date: 1 Page Count: 9

Pro II. Sound Level Meter V-9992

Circuit Breaker Analyzer & Timer CAT66

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126

LOW WEIGHT, SMALL SIZE,

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

H-series (Rectifier Module)

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Contact protection relay

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SVG3 (Basic Equipment)

Modular PDU Smart metering for your IT

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Circuit Breaker Analyzer & Timer CAT-P

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

Circuit Breaker Analyzer & Timer CAT-P

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

RT4B-110V/12A RECTIFIER

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

SmartPro LCD 120V 1300VA 720W Line- Interactive UPS, AVR, Tower, LCD, USB, 8 Outlets

Series Watt DC Power Supplies

Supplement. Manual Title: DSP-4000 Series User Supplement Issue: 3 Print Date: July 2001 Issue Date: 10/02 Revision/Date: Page Count: 4

RT4F-120V/20A-WAC RECTIFIER

Voltage Transducer UMT516 / MT516

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Quick Start Guide. Physical Description.

Autoranging True RMS Multimeter User Manual

User Manual. Printer P-52RUE

PCS POWER UPS. ST SERIES 1-10KVA UPS True On-Line High Frequency Double Conversion Technology. Uninterruptible Power Supply

PROFITEST Tester for DIN EN and VDE 0113

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Millenium II +: general characteristics

Circuit Breaker Analyzer & Timer CAT-P

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Keysight U8030 Series Triple-Output DC Power Supplies

MIC-2 Multi-instrument DATA SHEET

PHOENIX CONTACT - 01/2007

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

OmniVS 230V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port, C13 Outlets

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

Cabinet Interface Device

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

SmartPro LCD 120V 50/60Hz 1500VA 900W Line- Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

RT4F-48V/50A-WAC RECTIFIER

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

RM35TF V AC

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

COGNEX. Checker SensorView. Quick Reference Guide

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

The specifications for the Cisco 7304 router are listed in Table A-1.

Digital Clamp Meter User Manual

02/11/2015

Transcription:

Manual Supplement Manual Title: 1760 Users Supplement Issue: 5 Print Date: June 2006 Issue Date: 2/18 Revision/Date: 2, 5/10 Page Count: 5 This supplement contains information necessary to ensure the accuracy of the above manual. This manual is distributed as an electronic manual on the following CD-ROM: CD Title: 1760 CD Rev. & Date: 5, 7/2010 CD PN: 2583518 2011-2018 Fluke Corporation. All rights reserved. x

1760 Users Manual Supplement Change #1, 57261, 57516 On page 1-7, replace the first figure with: On page 5-3, under General Specifications, replace the Power Supply with: Power Supply Nominal Power Supply Operating 100 to 240 V ac, 50/60Hz, 100 to 350Vdc 83 to 264 V ac, 45 to 65 Hz, 100 to 375Vdc, 35W/70 VA On page 6-5, under Flexible Current Probes for AC, replace the Model No. Product No. column with: Model No. Product No. TPS FLEX 18-TF-II 4531837 TPS FLEX 24-TF-II 4531843 TPS FLEX 36-TF-II 4531855 On page 6-18, under General Specification:add the Measurement head cross section specifications and replace Weight, and Order-number with: Measurement head cross section: Weight: 8 mm (0.3 in) Order-number: 4531837 Approx. 0.3 kg (0.66 lb) On page 6-21, under General Specification, add the Measurement head cross section specifications and replace Weight, and Order-number with: Measurement head cross section: Weight: 8 mm (0.3 in) Order-number: 4531843 Approx. 0.35 kg (0.66 lb) On page 6-25, under General Characteristics, add the Measurement head cross section specifications and replace Weight, and Order-number with: Measurement head cross section: Weight: 8 mm (0.3 in) Order-number: 4531855 Approx. 0.4 kg (0.88 lb) 2/18 1

Manual Supplement 1760 Users Change #2, 67378, 67383 On page 1-3, in the Symbols table, replace the CAT II, III, IV entires with: Ã CAT II CAT III CAT IV Conforms to relevant South Korean EMC Standards. MEASUREMENT CATEGORY II is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the lowvoltage MAINS installation. MEASUREMENT CATEGORY III is applicable to test and measuring circuits connected to the distribution part of the building s low-voltage MAINS installation. MEASUREMENT CATEGORY IV is applicable to test and measuring circuits connected at the source of the building s low-voltage MAINS installation. On page 1-4, replace Figure 1-1 with: Figure 1-1. CAT 1-1.bmp Under Safety Instructions, remove the first sentence. 2 2/18

1760 Users Manual Supplement On page 1-8, replace Figure 1-3 with: Figure 1-3. Top View Grafikview.eps On page 1-9, replace Table 1-2, with: Item Description Mains connection Mains switch LED indicators Ethernet connector USB connectors COM1 serial port Feature connector (GPS, DCF 77, COM2, alarms, etc.) Measurement input connectors Reset button USB LED On page 1-15, replace the last sentence in Ethernet port with: For direct connection of the instrument to a PC, use the cross-linked Ethernet cable (do not use the gray plug). Change: To: USB connectors,, USB connectors reset button, USB LED. Under the first bullet, replace the sentence with: USB LED behavior during the USB copy process. 2/18 3

Manual Supplement 1760 Users Under 2 USB connectors, replace the Note with: Note A USB stick must not be pulled out while the USB LED flashes. This can cause permanent damage to the storage media. Only remove the USB stick while the USB LED is OFF or statically ON. Do not use the USB and data connection at the same time. Stored data can be erased by holding down the Reset button while switching on the instrument. This may be useful if the memory is full and may also resolve connectivity issues. On page 1-18, remove the first paragraph Compact Flash Card. On page 2-4, under Simple Measurements Function Check, replace the first sentence after Connect device with: Connect your computer and the recorder with the Crossover Ethernet cable (do not use the gray plug). On page 4-4, under Replacement of Battery Pack, replace the 4 th bullet with: For replacement of the battery pack, use only the original spare part (PN 3114277). On page 5-3, under General Specifications, Ambient condition, replace Operating temp. range with: Operating temperature range...0 C to +50 C, 32 F to +122 F (Startup temp 5 C (41 F)). On page 5-3, under General Specifications, remove the Quality system, Protection, Electrical safety, Environmental, and Emissions/Immunity entries and add: IP Rating...IEC 60529: IP40 Safety...IEC 61010-1: Overvoltage Category III, Pollution Degree 2 Electromagnetic Environment...IEC 61326-1: Basic IEC 61010-2-030: As specificed by attached accessory. Electromagnetic Compatibility...Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & Communication Equipment) [1] [1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. Radio Frequency Emissions...IEC CISPR 11: Group 1, Class A. Group 1 have intentionally generated and/or use conductively coupled radiofrequency energy which is necessary for the internal functioning of the equipment itself. Class A equipment is suitable for use in non-domestic locations and/or directly connected to a low-voltage power supply network. On page 5-5, replace Flicker with: Flicker As per IEC 61000-4-15:2010 10 min (PSt), 2 h (Plt) On pages 6-7, 6-11, 6-15, 6-18, 6-22 and 6-25 replace the Safety Standards with: IEC 61010-1: Pollution Degree 2 IEC 61010-031 IEC 61010-2-032: 300 V CAT IV 4 2/18

1760 Users Manual Supplement Change #3, 558 On page 6-4, in the first table, replace footnotes 2 and 3 with: 2 sensor + basic unit 0.1 % of Udin = 230 V P-N in accordance with IEC61000-4-30 Class A - for values <10 % and >150 % of Udin 0.15 % of rdg ±0.48 V 3 sensor + basic unit 0.1 % of Udin = 480 V and 600 V P-N in accordance with IEC61000-4-30 Class A - for values <10 % and >150 % of Udin 0.15 % of rdg ±0.8 V 2/18 5