FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

Similar documents
Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual

Fisher FIELDVUE DVC6200 HW2 Management of Change Guide

Installing ValveLink DTM Software

Converting a Router DTM Installation to

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

HART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers

AMS ValveLink Software Quick-Start Guide

Baumann Little Scotty Bronze Control Valve

Dimensions for NPS 2 CL150 through 1500 Slip On Flange Connections

FIELDVUE Instrumentation

Module Definitions, IO Bytes, and Data Length for FIELDVUE DVC6200p PROFIBUS PA Digital Valve Controller

DVC2000 Series FIELDVUE Digital Valve Controllers

Fisher FIELDVUE DVC2000 Digital Valve

Fisher FIELDVUE DVC2000 Digital Valve

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

ScannerCal Accuracy Verification System for the FlowScanner

HK-H375A HART. Hand Held Communicator. Manual

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

Advanced Test Equipment Rentals ATEC (2832)

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

Safety manual for Fisher FIELDVUE DVC6200 SIS Digital Valve Controller, Position Monitor, and LCP200 Local Control Panel

HART Actuator Field Unit Technical Manual Modular Design Electric Valve Actuators

Fisher i2p-100 Electro-Pneumatic Transducer

Smart Wireless THUM Adapter

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Smart Wireless THUM Adapter

ControlWave Micro HART / BTI Interface Module

Communicator to a HART device, the tag and model number of the connected device is automatically displayed on the top line of the LCD screen!

Type i2p-100 Electro-Pneumatic Transducer

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

HART Communicator. Emerson Process Management Catalog

H375A HART. Hand Held Communicator. Manual

Rosemount 2051G Pressure Transmitter

HART Actuator Field Unit Technical Manual. (IQ / IQT 3 rd generation, CVA, CMA DEV_REV2) Publication PUB _0615

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) IFC090 KROHNE 11/2000

375 Field Communicator

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

HART Communicator. MAN 4275A00 PN: English July 2000

FIELDVUE DVC2000 Series Digital Valve Controllers

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

Installing ValveLink Software. ValveLink Solo ValveLink SNAP ON ValveLink DTM ValveLink PLUG IN for PRM. Installation Guide D102800X012

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

ControlWave Micro HART / BTI Interface Module

Fisher FIELDVUE DVC2000 Digital Valve

Fisher i2p-100 Electro-Pneumatic Transducer

M0310 MODBUS to HART Module User Manual

LC-110/H. Reference Manual

Fisher FIELDVUE DVC6000f Digital Valve Controllers (Supported)

Advanced Test Equipment Rentals ATEC (2832) 375 Field Communicator. 375 Field Communicator. Product Data Sheet

S-series Foundation Fieldbus I/O

ControlWave PAC Analog Input / Output Modules

PD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06

Rosemount Transmitter Diagnostics Reduce Maintenance Costs

ControlWave Micro Analog Input / Output Modules

THZ 2 & TDZ 2 THZ 2 & TDZ. 2 Programmable Smart HART. TPRG Programmable Smart HART. Temperature Transmitter and Display. November D

Technical Bulletin, HT/HM HART Module

2014 UK & Ireland Training Offerings

FREQUENTLY ASKED QUESTIONS

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

DELTA CONTROLS CORPORATION

No J March Temperature Concentrator System Multi-Channel Transmitter TCS

Bristol IStran. Product Data Document 1660DS-4a July 19, Page 1

S-series H1 I/O Card with Integrated Power

475 Field Communicator

Fisher i2p-100 Electro-Pneumatic Transducer

Rosemount VeriCase User Guide

M-series Foundation Fieldbus I/O

Rosemount 248 Wireless Temperature Transmitter

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) Process Device Manager (PDM) Device Type Manager(DTM) M10

1.6 Configuring Intelligent Devices

475 Field Communicator

AwiaTech WirelessHART TM Rapid Development Kit Manual

M-series Intrinsically Safe I/O

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

475 Field Communicator

Rosemount 2051 Wireless Pressure Transmitters

HART. Actuator Control. Redefining Flow Control

Rosemount 702 Wireless Discrete Transmitter

Electrical Measurement Module Kit with Docking Station

HART 7.x Field Device Specification for Honeywell SLG 700 SmartLine Level Transmitter 34-SL Rev 6.0 December 2017

475 Field Communicator

Oldham OLCT 200 Revision 1

Type 330SA High-Performance Electric Actuator

Scanner 2000 Steam Mass Flow Transmitter

ControlWave PAC Digital Input / Output Modules

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

HART Applications SEC-5000 Gas Detector

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

DELTA CONTROLS CORPORATION

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

PD Channel Digital IO PD Series 600

Advanced Test Equipment Rentals ATEC (2832)

Analog Output Isolators

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Transcription:

Instruction Manual Supplement D103267X012 FIELDVUE Digital Valve Controllers Supplement to HART Communicating Fisher FIELDVUE Digital Valve Controller Instruction Manuals Using the HART Tri-Loop HART-to-Analog Signal Converter with Fisher FIELDVUE Digital Valve Controllers Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers The Rosemount 333U (alarm high) and 333D (alarm low) HART Tri-Loop HART-to-Analog Signal Converter is used to read values from the digital valve controller and present them as 4 to 20 ma signals accessible to AI channels on traditional host systems. This device accepts a HART burst command 3 from a smart instrument and converts it into up to three 4 to 20 ma analog output signals. The output signals then can be read by a control system s analog input channels. See table 1 for command 3 variables. Figure 1 shows a typical installation of the Tri-Loop signal converter with a digital valve controller. The Tri-Loop signal converter may be used with the following FIELDVUE digital valve controllers: DVC5000 Series digital valve controllers with firmware revision 5, hardware revision 5 or newer. (DVC5000 Series digital valve controllers with firmware revisions earlier than revision 5 do not support burst mode communications. Instruments with firmware revision 5 and hardware revision 4 are not recommended for use with the Tri-Loop signal converter.) DVC6000 Series digital valve controllers, or DVC2000 Series digital valve controllers. Table 1. Command 3 Variables (1) TYPE VARIABLE VARIABLE NAME RANGE Primary Travel 0 to 100% (2) Secondary Travel Target 0 to 100% DVC5000 Firmware 5 Tertiary Pressure 0 to 100 psi 0 to 6.9 bar 0 to 690 kpa Quaternary Auxiliary Status Either 0 or 100% Primary Travel 0 to 100% Secondary Travel Target 0 to 100% DVC5000 Firmware 6 Tertiary Pressure 0 to 100 psi 0 to 6.9 bar 0 to 690 kpa Quaternary Drive Signal 0 to 100% Primary Analog Input 4 20 ma or 0 to 100% depending on instrument configuration DVC6000 Secondary Travel Target 0 to 100% 0 to 100 psi Tertiary Pressure (Supply or Output) (3) 0 to 6.9 bar 0 to 690 kpa Quaternary Travel 0 to 100% (2) Primary Analog Input 4 20 ma or 0 to 100% depending on instrument configuration DVC2000 Secondary Travel Target 0 to 100% Tertiary Pressure (Output) 0 to 100% 0 to 6.9 bar 0 to 690 kpa Quaternary Travel 0 to 100% (2) 1. AC tier does not support HART Command 3 or Burst Mode communications. 2. 0% valve travel is the zero control signal position for DVC5000 firmware 5, DVC6000, and DVC2000. 3. DVC6000 HC tier does not provide Supply Pressure. The Tri-Loop signal converter outputs will go to their fail state when any of the following occur: there is a loss of burst mode communication from the smart instrument www.fisher.com

FIELDVUE Digital Valve Controllers Instruction Manual Supplement NON-HAZARDOUS AREA HAZARDOUS AREA CHANNEL 1 MUST BE POWERED FOR THE TRI-LOOP TO OPERATE EACH TRI-LOOP CHANNEL RECEIVES POWER FROM CONTROL ROOM VALVE TRAVEL CHANNEL 2 CONFIGURED OUTPUT (OPTIONAL) CHANNEL 3 CONFIGURED OUTPUT (OPTIONAL) BURST INPUT CONTROL ROOM HART COMMUNICATION CONNECTION FIELD INSTRUMENT CONNECTION CONTROL SYSTEM CONNECTION + ANALOG OUTPUT CONTROLLING DIGITAL VALVE CONTROLLER + FISHER HF300 SERIES HART FILTER USE AN HF340 IF FILTER ACTION IS REQUIRED. USE AN HF341 IF NO FILTER ACTION IS REQUIRED. INTRINSIC SAFETY BARRIER IF REQUIRED BY APPLICATION FIELDVUE DIGITAL VALVE CONTROLLER IN BURST MODE (COMMAND 3) Figure 1. Example HART Tri-Loop HART-to-Analog Signal Converter Installation with a FIELDVUE DVC6000 Digital Valve Controller there is a device malfunction reported by the smart instrument, or there is a loss of power to channel 1 of the signal converter. Loss of power to channel 1 will cause all channels to go to their fail state. Loss of power to either channel 2 or 3 will not affect the remaining channels. When in its fail state, a 333U signal converter generates a current of 21.75 ma or greater. A 333D generates a fail state current which is less than 3.75 ma. The Tri-Loop signal converter is not recommended for FIELDVUE digital valve controller applications involving: split-ranging, or multi-drop (digital set point) 2

Instruction Manual Supplement FIELDVUE Digital Valve Controllers TRI-LOOP MODEL 333D 333U Table 2. Tri-Loop HART -to-analog Signal Converter Configuration Choices (1) FAIL STATE Low High 1 (Travel) CHANNEL (2) 2 (Travel Target) 3 (Not Configured) 0 to 100% 0 to 100% Disabled 1. Tri-Loops pre-configured for use with DVC5000 digital valve controllers are configured differently than those pre-configured for use with DVC6000 and DVC2000 digital valve controllers. 2. Configurations of channels are preset, but can be changed with the 275 HART Communicator, the 375 Field Communicator, or AMS Device Manager. Installation Considerations The Tri-Loop HART-to-analog signal converter design allows three different din-rail mounting options: Asymmetrical 32mm G rail Symmetrical 35 x 7.5 mm top hat rail Symmetrical 35 x 15 mm top hat rail As shown in figure 1, the signal converter must be installed on the safe side of an Intrinsic Safety (IS) barrier. It is approved for FM and CSA ordinary location, and bears the CE marking to indicate compliance with applicable EC directives. It is not approved nor designed for nuclear-qualified applications. Figure 1 also shows a HART filter as a convenient connection point for the two additional connections to the loop wires. The necessity of a HART filter depends upon the control system; the Tri-Loop signal converter does not add a requirement for a filter. If a filter is required, the HF340 din rail mount filter provides a convenient method for connecting field wiring between the control system, the signal converter and the digital valve controller. If no filter is required, the HF341 is available without filter action (straight-through). Tri-Loop Signal Converter Configuration From Fisher The Tri-Loop HART-to-analog signal converter ships from Fisher pre-configured with one of the choices listed in table 2. As shown in the table the unit is available with either a high or low fail state. The channel 1 variable is always travel and the channel 2 variable is always travel target. Channel 3 is disabled, but can be configured by the user, using the 275 HART Communicator, the 375 Field Communicator, or AMS Suite: Intelligent Device Manager. The burst message from FIELDVUE digital valve controllers configured for fail-open actuators associates 0% travel with an open valve. Therefore, channel 1 of the Tri-Loop should be configured to provide a 20 ma output when the valve is open and a 4 ma output when the valve is closed (range is 100 to 0 rather than 0 to 100). Power Source Each output channel on the signal converter connects to a separate control system analog input channel. Each channel operates on a terminal voltage of 11 to 42.4 VDC. The signal converter is powered from the channel 1 power source. Lack of power on channel 1 will produce error states on channels 2 and 3. Enabling Burst Mode For a FIELDVUE digital valve controller to communicate with the Tri-Loop signal converter, the burst mode must be enabled. You can use a 275 / 375 Communicator, AMS ValveLink Software, or AMS Device Manager to enable burst mode in the digital valve controller. To enable the burst mode when using a DVC5000 digital valve controller with the 275 / 375 Communicator, select Main Menu and Detailed Setup. From the Detailed Setup menu select Mode then Burst. When using a DVC6000 or DVC2000 digital valve controller with the 275 / 375 Communicator, select Setup & Diag and Detailed Setup. From the Detailed Setup menu select Mode, then Burst. With ValveLink Software click the Detailed Setup icon, or, from the menu bar select Instrument Setup, 3

FIELDVUE Digital Valve Controllers Instruction Manual Supplement Detailed Setup, and Instrument, and then click the Alert Record and Commands tab. until the burst mode is disabled. Even if instrument power is lost, the instrument will continue to burst command 3 when power is restored. Note HART devices connected to an instrument which is actively using burst mode communication may experience some HART communication errors. You should not be concerned unless the errors do not clear after a few moments or if they disrupt ValveLink Software configuration, calibration, or diagnostic activities. If a disruption occurs, disable burst mode during these activities and turn it back on when completed. Once burst mode is enabled, the digital valve controller will continue to burst HART command 3 Troubleshooting Refer to table 3 for Tri-Loop diagnostic status messages. To reach the Diagnostic Status menu using the 275 / 375 Communicator, select Diagnostics/Service, Test Device, and Status (fast key sequence 1-1-1). Other Tri-Loop parameters can be access using the 275 / 375 Communicator or AMS Device Manager. Refer to figure 2 for the 275 / 375 Communicator menu tree, and table 4 for the fast-key sequence. Table 3. Tri-Loop Diagnostic Status Messages (1) ERROR MESSAGE INTERPRETATION CH1 Burst mode variable Not a Number CH2 Burst mode variable Not a Number CH3 Burst mode variable Not a Number Not applicable to the digital valve controller (always off ) CH1 Burst mode variable at saturation CH2 Burst mode variable at saturation CH3 Burst mode variable at saturation Burst mode message is invalid Parity or checksum error with burst message Burst mode message timeout Tri-Loop not receiving burst command 3 Non-volatile memory checksum error Internal problem with the Tri-Loop Field device reporting failure Device Malfunction status from the digital valve controller CH1 Channel output is fixed CH2 Channel output is fixed Channel commanded into Output fixed mode CH3 Channel output is fixed CH1 Burst mode message units error CH2 Burst mode message units error Channel s units do no match digital valve controllers units CH3 Burst mode message units error 1. ON = error is in effect. OFF = error is not active. 4

Instruction Manual Supplement FIELDVUE Digital Valve Controllers 1 TEST DEVICE 1 Status 2 Reset 1 DIAGNOSTICS / SERVICE 2 LOOP TEST 3 CALIBRATION 1 CONFIGURE CHANNELS 2 RECALL FACTORY TRIM 1 4mA 2 20mA 3 Other 4 End 1 CONFIGURE CH1 2 CONFIGURE CH2 3 CONFIGURE CH3 4 All 1 Burst Variable 2 Units 3 LRV 4 URV 5 Enabled 4 D/A TRIM 2 BASIC SETUP 1 Tag 2 CONFIGURE CHANNELS 1 CONFIGURE CH1 2 CONFIGURE CH2 3 CONFIGURE CH3 1 Burst Variable 2 Units 3 LRV 4 URV 5 Enabled Online Menu 1 DEVICE SETUP 3 DEVICE INFORMATION 1 Model 2 Dev ID 3 Tag 4 Date 5 Descriptor 6 Message 7 Final Asmbly Num 8 REVISION # s 1 Universal Rev 2 Fld Dev Rev 3 Software Rev 1 LOOP TEST 1 4mA 2 20mA 3 Other 4 End 1 OUTPUT CONDITION 1 ANALOG OUTPUT 2 D/A TRIM 3 SCALED D/A TRIM 1 Proceed 2 Change 3 DETAILED SETUP 2 HART OUTPUT 1 Poll Addr 2 Num Req Preams 3 Num Rsp Preams 4 REVIEW 2 DEVICE INFORMATION Model Manufacturer Dev ID Tag Descriptor Message Date Final Asmbly Num Universal Rev Fld Dev Rev Software Rev Poll Addr Num Req Preams 1 Model 2 Dev ID 3 Tag 4 Date 5 Descriptor 6 Message 7 Final Asmbly Num 8 REVISION # s 1 Universal Rev 2 Fld Dev Rev 3 Software Rev Figure 2. Menu Tree for the Tri-Loop Signal Converter 5

FIELDVUE Digital Valve Controllers Instruction Manual Supplement Table 4. Fast-Key Sequence for the Tri-Loop Signal Converter FUNCTION Fast-Key Sequence FUNCTION Fast-Key Sequence 20 ma (Loop Test) 1-2-1-2 Final Asmbly Num (Detailed Setup) 3-2-7 20 ma (Output Condition) 3-1-1-1-1-2 Fld Dev Rev (Basic Setup) 2-3-8 2 4 ma (Loop Test) 1-2-1-1 Fld Dev Rev (Detailed Setup) 3-2-8-2 4 ma (Output Condition) 3-1-1-1-1-1 LRV (Calibration) 1-3-1-1-3 All (Calibration) 1-3-2-4 LRV (Configure Channels) 2-2-1-3 Burst Variable (Calibration) 1-3-1-1-1 Message (Basic Setup) 2-3-6 Burst Variable (Configure Channels) 2-2-1-1 Message (Detailed Setup) 3-2-6 CH1 (Calibration) 1-3-2-1 Model (Basic Setup) 2-3-1 CH1 (D/A TRIM) 1-4-1 Model (Detailed Setup) 3-2-1 CH1 (Output Condition) 3-1-1-2-1 Num Req Preams 3-1-2-2 CH2 (Calibration) 1-3-2-2 Num Rsp Preams 3-1-2-3 CH2 (D/A TRIM) 1-4-2 Other (Loop Test) 1-2-1-3 CH2 (Output Condition) 3-1-1-2-2 Other (Output Condition) 3-1-1-1-1-3 CH3 (Calibration) 1-3-2-3 Poll Addr 3-1-2-1 CH3 (D/A TRIM) 1-4-3 Proceed (Scaled D/A Trim) 3-1-1-3-1-1 CH3 (Output Condition) 3-1-1-2-3 Reset 1-1-2 Change (Scaled D/A Trim) 3-1-1-3-1-2 Software Rev (Basic Setup) 2-3-8-3 Date (Basic Setup) 2-3-4 Software Rev (Detailed Setup) 3-2-8-3 Date (Detailed Setup) 3-2-4 Status 1-1-1 Descriptor (Basic Setup) 2-3-5 Tag 2-1 Descriptor (Detailed Setup) 3-2-5 Tag (Basic Setup) 2-3-3 Dev ID (Basic Setup) 2-3-2 Tag (Detailed Setup) 3-2-3 Dev ID (Detailed Setup) 3-2-2 Units (Calibration) 1-3-1-1-2 Enabled (Calibration) 1-3-1-1-5 Units (Configure Channels) 2-2-1-2 Enabled (Configure Channels) 2-2-1-5 Universal Rev (Basic Setup) 2-3-8-1 End (Loop Test) 1-2-1-4 Universal Rev (Detailed Setup) 3-2-8-1 End (Output Condition) 3-1-1-1-1-4 URV (Calibration) 1-3-1-1-4 Final Asmbly Num (Basic Setup) 2-3-7 URV (Configure Channels) 2-2-1-4 6

Instruction Manual Supplement FIELDVUE Digital Valve Controllers Related Fisher Documents FIELDVUE DVC5000 Series Digital Valve Controllers Instruction Manual Note The DVC5000 digital valve controller is obsolete. Contact your Emerson Process Management sales office if a copy of this instruction manual is needed. Bulletin 62.1:DVC6000 Fisher FIELDVUE DVC6000 Series Digital Valve Controllers (D102758X012) Fisher FIELDVUE DVC6000 Series Digital Valve Controllers Instruction Manual (D102794X012) Fisher FIELDVUE DVC6000 Series Digital Valve Controllers Quick Start Guide (D102762X012) Bulletin 62.1:DVC2000 Fisher FIELDVUE DVC2000 Series Digital Valve Controllers (D103167X012) Fisher FIELDVUE DVC2000 Series Digital Valve Controllers Instruction Manual (D103176X012) Fisher FIELDVUE DVC2000 Series Digital Valve Controllers Quick Start Guide (D103203X012) Bulletin 62.1:HF300 Fisher FIELDVUE HF300 Series HART Filters (D102798X012) Fisher FIELDVUE HF300 Series HART Filters instruction manual (D102796X012) Related Rosemount Documents For more information on the Tri-Loop HART-to-analog signal converter, refer to the following Rosemount documents, available from the Rosemount Measurement division: Model 333 HART Tri-Loop HART -to- Analog Signal Converter (product manual), Rosemount Document Number 00809-0100-4754 Model 333 HART Tri-Loop HART -to- Analog Signal Converter (product brochure), Rosemount Document Number 00813-0100-4754 HART Communicator (product manual) Rosemount Document Number 00275 8026-0001 Note The 275 HART Communicator is obsolete. Contact your Emerson Process Management sales office if a copy of this product manual is needed. 375 Field Communicator (user s manual), Rosemount Document Number 00375 0047 0001 Note Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use, or maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchase and end-user. 7

FIELDVUE Digital Valve Controllers Instruction Manual Supplement Fisher, FIELDVUE, Tri-Loop, Rosemount, AMS, and ValveLink are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end-user. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com Fisher 8 Controls International LLC 2006, 2009; All Rights Reserved