Web-enabled DAQ System

Similar documents
Tablet Recorder. Web-enabled DAQ System. Bring your own tablet. Tablet Recorder. Taking signals from PLC and other devices

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

Paperless Recorder VGR-B100. Series

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: WL40EW2F. Wireless I/O WL40F Series

Communication Interface

SH2WEB24. Central unit module. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

WEB-ENABLED REMOTE TERMINAL UNIT Model: DL8 USERS MANUAL

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

User Manual. cmt-svr Startup Guide

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

AUDIN - 8, avenue de la malle Saint Brice Courcelles - Tel : Fax : Web : http:

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

SA2WEB24. Central unit module. Benefits. Description

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

A NEW DATA LOGGER Stand alone. Secure. Fast.

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

Compact data logger offering best-in-class noise resistance and communication function

AIAS. Technical description

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

User Manual. cmt-svr Startup Guide

USB-5100 Series Multi-Channel Data Loggers

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

X-Log Expert Data Logger

Com X 210, Com X 510 Technical Datasheet

GS828. GPRS Data Logger

Ethernet I/O Modules: ADAM-6000

BACnet Controller for General-purpose Building Applications

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

FCU-4 FAN COIL CONTROLLER

General information. Display. Supply voltage

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

GS828-H. GPRS Data Logger

General information. Display. Supply voltage

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Operator units CDPX Key features

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

General information. Display. Supply voltage

Saved Data playback Saved data in Memory card can be easily called out and played back on display

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Advancing AiHD Cloud Solution

General information. Display. Supply voltage. Input current

WISE-52xx Intelligent IIoT Concentrator

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

EC-PU4. Processor unit with 4 communication ports

General information. Display. Supply voltage. Input current

Wireless IoT Sensing Solutions

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted

General information. Display. Supply voltage. Input current. Encoder supply. Output current

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Monitoring various parameters with one power meter!

General information. Display. Supply voltage. Input current

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

LDALI ME204-U, LDALI ME201 U

ACONIS Advanced Control & Integration System

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

3.1 Updating Web Package Updating OS... 16

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

iologik 2500 HSPA/GPRS/WLAN Series

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

General information. Display. Supply voltage. Input current. Encoder supply. Output current

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Intech Micro 2400-A16-SD

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

General information. Display. Supply voltage. Input current

JUMO mtron T Measuring, Control, and Automation System

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

DISCONTINUED MODEL Replaced with Model MSRPAC-2006

MIC-2 MKII, Multi-instrument DATA SHEET

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

USB-500/600 Series Low-Cost Data Loggers and Accessories

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

GenIP : Intelligent gateway dedicated to most critical industrial applications

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

General information. Display. Supply voltage. Input current. Encoder supply. Output current

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

UA-5200 IIoT Communication Server

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

Redundant System Redundant System P9-1-1

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Transcription:

2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing User graphics Overview window Now, your tablet can be used as the display for a data recorder!

Hello, I'm your! Router Tablet Recorder Mobile Data Screen Web-enabled DAQ System via Wireless LAN Lab Wireless LAN Bioscience Wireless LAN router Brewing Agriculture Web-enabled DAQ System Various sensors

New TR30-G Leave only the Display and Operation functions open on the tablet! In the development lab In the experiment lab In the testing lab Process Plants Display and Operation No special apps required for tablet Engine Development Leave it to me for Generating Data Logger Screens, Saving & Transferring Data and Monitoring & Reporting Energy Monitoring Generating Data Logger Screens Saving & Transferring Data Trend data Comment data Event data Environmental Testing Trend graph Overview Monitoring & Reporting Event reporting mail Regular reporting mail Graphics Event summary

Multiple people can work on the same data logger at the same time! 1:n e B Conventional Paperless Recorder Common experimenting lab re o f Lab A Getting back to check the distant recorder is so hard! It's such a waste to have to meet back at the recorder all the time! Conventional paperless recorder Lab B Lab C I have no idea what the current value is! Lab C Lab A Lab B A Tablet Recorder e ft r I can check my results from the desk in my office! Everyone can see the same screen! Lab A Lab B Lab C Sensors Wireless LAN router Lab A Lab C I can check out the current value in real time. Lab B 4

Multiple data loggers can be accessed from a single tablet! n:1 e B Conventional Paperless Recorder re o f I'm tired of running around here and there between recorders! Sensors Conventional paperless recorder A e ft Wireless LAN router Tablet Recorder Sensors 7 r Now it's so easy to check all my data loggers right from my office!

Features of the TR30-G WEB SERV High Speed Sampling Highest rate 5 ms (16-point Ai/Pi, 32-point Di/Do) CURRENT DATE CURRENT TIME Maintenance Free Large main memory plus SD card realizing continuous recording for more than 10 years Flexible I/O 64 x Ai, Di and Do, 32 x Pi and Oi (function channels) Modbus/TCP Master PEN TIP External I/O modules can be added. Modbus/ TCP Slave Start/stop the logger or e-mailing controlled by a remote PLC. FTP Server and Client Files stored on SD cards inside the can be uploaded to a PC or a cloud server. Event Triggered Recording Start/stop logging by a high/low or status alarm trip or an external trigger from the PLC or PC. E-mailing PID cascade control simplified flow chart Sending e-mails by triggers of alarm trip or by external contact signal. Tank water level setpoint Tank water level Tank water level Built-in Browser Views User Defined Graphic View Trend, Overview, Event Summary, Comment Summary Create your own screens using Javascript, etc. PV SP LIC 04 MV Flow rate setpoint SP Flow rate setpoint PV Flow rate measured value FIC 01 MV M Tank 5 MENU BU

Easy to use... just ONE touch! VER URL UTTON UNACKNOWLEDGED EVENTS START/STOP RECORD SCREEN LOCK PAGE BUTTON DIGITAL DISPLAY AREA Tag names and status of measurement signals are displayed as numerals or characters. Analog signals can be displayed as the engineering unit value or percentages. CHANNEL NAME CHANNEL COMMENT PEN COLOR PEN NUMBER BAR INDICATOR DIGITAL DISPLAY Changing color by signal state (or simple bargraph for Ai percentage data) Ai: Numerical display of percent or engineering unit value (switched by tapping on the selected pen display) Di: Text assigned to ON/OFF states Pi: Numerical display of engineering unit value Do: Text assigned to ON/OFF states Convenient Tablet Functions Print out trend screen Wi-Fi Screen capture and air print Wi-Fi printer Screen capture and e-mail E-mail Send captured screen as e-mail attachment 6

TR30-G SPECIFICATIONS GENERAL SPECIFICATIONS Calendar clock: Year (4 digits), month, date, day, hour, minute, second Max. number of R30 I/O modules: 8 (Max. consumption current of I/O modules: 500 ma) Isolation: Ethernet to internal bus or internal power to RUN contact output to power supply to FE Read rate: ETHERNET COMMUNICATION Communication Standard: IEEE 802.3u Transmission: 10BASE-T, 100BASE-TX Baud rate: 10/100 Mbps (Auto Negotiation function) Protocol: TCP/IP, Modbus/TCP, HTTP, FTP, SMTP, SNTP Maximum segment length: 100 m Ethernet indicator LED: DPX, LNK IP address: 192.168.0.1 (factory setting) INSTALLATION Power input: 24V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Operating temperature: 0 to 50 C (32 to 122 F) Operating humidity: 10 to 90 %RH (non-condensing) Mounting: Installation Base (model: R30BS), Surface or DIN rail Weight: 300 g (0.66 lb) (stand alone TR30) PERFORMANCE Calendar clock: (with battery backup) Accuracy: Monthly deviation 2 minutes at 25 C Back up period: Approx. 2 years at 25 C Battery: Primary lithium battery (non-removable) Insulation resistance: Dielectric strength: 1500 V AC @ 1 minute (Ethernet to internal bus or internal power to RUN contact output to power supply to FE) DATA STORING The trend data, event data and comment data are stored into the internal memory with specified storing rate. It is available to transfer into the SD card with the timing according to the logging rate. Trend data Channel: Max. 120 points (Choose among followings: analog input (Ai), discrete input (Di), pulse input (Pi), function input (Oi), discrete output (Do). Storing rate: 5, 10, 50, 100 & 500 ms; 1, 2, 5 & 10 sec.; 1, 2, 5, 10 & 30 min.; 1 hour Sampling rate: 5 ms (for logging rate less than 50 ms) 100 ms (for logging rate between 100 ms and 1 sec.) 1 sec. (for logging rate over 2 sec.) Event data The TR30-G records a log when an event occurs, and can display a message on the time axis in a trend graph. Event: Transition of analog input zone, transition of pulse input zone, status change of discrete input Event detection interval: Same as trend data sampling rate Stored contents: Date/time, event Number of event: 3000 Comment data Comments can be added to trend graphs, and a list of entered comments can be later confirmed in a Comment summary page. Once entered, comments can also be edited and removed. Number of characters for comment: 32 Stored contents: Date/time, comment Number of comment: 1000 EXTERNAL DIMENSIONS unit: mm (inch) 110 (4.33) 100 (3.94) 4(.16) 50(1.97) SD Card Recording contents: Trend data, event data, comment data, settings information Data format: Trend data, event data and comment data are saved with dedicated format (binary, extension TRD ) or CSV format. Setting information is saved into text format (xml format, extension xml ). CSV format can be selected with storing rate 100 ms or longer. Deleting recorded data: When auto file delete is disabled, it is available to store until there is no remaining space in the SD card. When auto file delete is enabled and the remaining space in the SD card reaches 100 MB, the data is deleted from oldest. Storable time duration (rough guide for 4 GB SD card, when only trend logging is enabled.) Binary format STORING RATE 16 pens 32 pens 5 ms 3 days 100 ms 50 days 30 days 500 ms 8 months 4 months 1 sec. 1 year 9 months 5 sec. 7 years 4 years 1 min. 1 hour 10 years (max. 10 years) CSV format STORING RATE 100 ms 500 ms 1 sec. 5 sec. 1 min. 1 hour 16 pens 32 pens 28 days 15 days 4 months 78 days 9 months 5 months 3.5 years 2 years 10 years (max. 10 years) A SD card is required to store data in the unit. Use the specified model number of memory card. Available for purchase from M-System. Consult M-System. 24 (.94) [5 (.20)] DIN RAIL (35mm wide) 7 (.28) 4 (.16) 50(1.97) 110 (4.33)