Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

Similar documents
H3CA-8H-AC/100/110/120

Solid-State Counter/Timer

Temperature Controller E5C4

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Model Number Structure

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Model Number Structure

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Special-Purpose Proximity Sensor E2C

Self-Powered Counters H7EC

Special-Purpose Photoelectric Sensors

Model Number Structure

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Model Number Structure

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

J ACCESSORY CROSS REFERENCE LIST

masterelectronics.com onlinecomponents.com

Model Number Structure

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Solid-state Timer H3YN


Model Number Structure

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Miniature Inductive Prox TL-W

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Cam Positioner H8PS. Plastic body, 2 m (6.56 ft.) cable Metal body, 2 m (6.56 ft.) cable

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

onlinecomponents.com

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Chemical Resistant Inductive Prox

Capacitive Prox E2K-X

Chip Immune Inductive Prox E2EZ

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

General-Purpose Photoelectric Sensor

Model Number Structure

2. Actuator B: Ball type P: Pin type F: Flat type

25 m 5 m 1 m. Part Number Mounting bracket. E39-LU1 Mounting bracket for E39-R1 reflector

Inductive Proximity Sensor

onlinecomponents.com

E2K-C25MY1 E2K-C25MY2

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

Model Number Structure

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Digital Timer Ultra-compact Timer Provides Advanced Functions and Security Settings. Features

I/O delay. (0.32 in ±0.06 in)

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

TIMERS FOR ALL APPLICATIONS

Plastic Cylindrical Inductive Prox

Multifunction Counter/Tachometer H7CX Series

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard.

SYSMAC Remote Transistor Module

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Inductive Proximity Sensor

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Adjustable Capacitive Prox E2K-C

Voltage Current Front-mounting bracket

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Digital Timer H5CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Inductive Proximity Sensor

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Switching Power Supply

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Capacitive Prox E2K-X

Transistor drive 2c/4c 5A slim power relays

Thread length (overall length) material

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Multifunction Preset Counter H7CX

Z-15GW2277 Z-15GW2277-B

78 Series Electromechanical Relay Selection Guide

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Chapter. In This Chapter...

D2SW-3L1HS D2SW-01L1HS

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

H2C Motor Timers will be Discontinued March 2013; Replace with H3CR-A8E Solid-state Timer

Model Number Structure

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

7511 / / / 711 / / 731 / Preset 27

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Solid State Relays with Failure Detection Function

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Transcription:

Digital Timer 1/16 DIN, Quartz Timer with Four-Digit LED Display Five wide ranges to choose from Wide-range AC or DC supply voltages Elapsed time (UP) or time remaining (DOWN) display available Selectable no-voltage reset and gate inputs expand capabilities Memory protection circuit available on AC/DC models; order back-up battery separately from accessories Easy-to-read 8 mm-high LED display Panel mounting adapter, sockets, and accessories may be ordered separately Ordering Information TIMERS NOTE: The complete part numbers shown here are the only timers currently available. Some time ranges and supply voltages have been discontinued. Timing functions -delay Contact type SPDT relay Solid-state open collector Display type Elapsed time (UP) Time remaining (DOWN) Elapsed time (UP) Memory protection Not provided Provided Not provided Not provided Terminal form 8-pin round 11-pin round 8-pin round socket 8-pin round socket socket socket Part number 0.001 to 9.999 sec -XZNS-AC0-240 -XZNS-DC12-48 0.01 to 99.9 sec -XAN-AC24 -XAN-AC0-240 -XANM-AC0-240 -YAN-AC0-240 -XANS-AC0-240 -XAN-DC12-48 -YAN-DC12-48 -XANS-DC12-48 0.1 to 999.9 sec -XBN-AC24 -XBN-AC0-240 -XBNM-AC0-240 -YBN-AC0-240 -XBN-DC12-48 -XBNM-DC24 -YBN-DC12-48 1 s to 99 min 59 s -XCN-AC24 -YCN-AC24 -XCN-AC0-240 -XCNM-AC0-240 -YCN-AC0-240 -XCN-DC12-48 -YCN-DC12-48 1 min to 99 h 59 min -XDN-AC24 -XDN-AC0-240 -XDNM-AC0-240 -YDN-AC0-240 -XDN-DC12-48 -YDN-DC12-48 1

ACCESSORIES Description Part number Sockets 11-pin Bottom surface or track mounting, top screw terminals P2CF-11 Bottom surface or track mounting, top screw terminals, finger safe terminal P2CF-11-E conforms to VDE06/P0 Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3GA-11 8-pin Bottom surface or track mounting, top screw terminals P2CF-08 Bottom surface or track mounting, top screw terminals, finger safe terminal P2CF-08-E conforms to VDE06/P0 Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-08 Terminal cover for P3G sockets, conforms to VDE06/P0 Y92A-48G Panel mounting adapter Fits behind panel, ideal for side by side installation. Use P3G - sockets Y92F-30 Battery for Use with - M timers Y92S-20 memory backup Protective cover Hard plastic cover protects against dust, dirt and water; not for use with panel covers Y92A-48B Soft plastic cover protects against dust, dirt and water; not for use with panel covers Y92A-48D NEMA 4 cover Waterproof front cover Y92A-48N Mounting track DIN rail, 50 cm (1.64 ft) length; 7.3 mm thick PFP-50N DIN rail, 1 m (3.28 ft) length; 7.3 mm thick PFP-0N DIN rail, 1 m (3.28 ft) length; 16 mm thick PFP-0N2 End plate PFP-M Spacer PFP-S Specifications Part number -X N -X NM -Y N -X NS Supply voltage Operating voltage Power consumption Timing functions AC 24 V, 0 to 240 V; 50/60 Hz 0 to 240 V; 50/60 Hz DC 12 to 48 V (permissible ripple factor; 20% max.) 85 to 1% of the rated voltage AC 12 VA at 240 VAC, 50/60 Hz DC 2.5 W at 48 VDC 2.5 W at 48 VDC -delay with elapsed time display -delay with time remaining display -delay with elapsed time display Reset, gate inputs No voltage Control output Type Time limit SPDT relay Open collector solid-state Instantaneous Max. load 3 A, 250 VAC (p.f. = 1) 0 ma max. 30 VDC Min. load ma, 5 VDC Repeat accuracy ±0.01% ±0.05 sec max. (power- start); ±0.005% ±0.03 sec max. (reset start) Setting error See "Repeat accuracy" Resetting system Power- and external reset Resetting time Power : 0.5 sec min.; External reset: 0.02 sec signal min. Indicators Time UP (red LED), 8 mm LED numeric display Materials Plastic Mounting Panel, track, surface Connections 8-pin round socket 11-pin round socket 8-pin round socket Weight 150 g (5.31 oz.) Approvals UL/CSA/SEV Operating ambient temperature - to 55 C (14 to 131 F) Humidity 35 to 85% RH Specifications table continued on the next page. 2

SPECIFICATIS continued Part number -X N -X NM -Y N -X NS Vibration Mechanical durability to 55 Hz; 0.75 mm (0.03 in) double amplitude Malfunction durability to 55 Hz; 0.5 mm (0.02 in) double amplitude Shock Mechanical durability 30 G Malfunction durability G Variation due to voltage change See "Repeat Accuracy" Variation due to temperature change See "Repeat Accuracy" Insulation resistance 0 MΩ min. at 500 VDC Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed noncurrent-carrying metal parts, between power supply circuit, and control output circuit Service life Mechanical million operations minimum Not applicable Electrical 0,000 operations minimum at maximum ratings Not applicable Engineering Data ELECTRICAL SERVICE LIFE Note: The service life graphs apply to all relay output models. They do not apply to solid-state output models -XZNS or -XANS. 3

Timing Charts ELAPSED TIME (UP) DISPLAY Reset input Gate input (interruption) Time up Digital display Control output (NO) Time UP indicator Set value TIME REMAINING (DOWN) DISPLAY Reset input Gate input (interruption) Digital display Set value No display No display Time up Control output (NO) Time UP indicator Dimensions Unit: mm (inch) TIMERS Panel cutout 50 45 (1.97) (1.77) 48 (1.89) 44.8 (1.76) 50 (1.97) 45 (1.77) 48 (1.89) 97.4 (3.84) Note: Recommended panel thickness is 1 to 3.2 mm. Panel cutout conforms to DIN 43700. 4

ACCESSORIES P2CF-08 Track Mounting/Front Connecting Socket Eight M3.5 x 7.5 sems 70 max. (2.76) 7.8 (0.31) 3 (0.12) Two 4.5 dia. holes 4.5 (0.18) 35.4 (1.39) Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes Two, 4.5 dia. or two M4 socket mounting holes 40 ± 0.2 (1.57) 4 (0.16) 50 max. (1.97) 20.3 max. (0.80) P2CF-08E Finger Safe Terminal Type Conforming to VDE06/P0 Eight M3.5 x 7.5 sems 7.8 (0.31) 5 4.5 (0.18) 3 70 max. (2.76) Two 4.5 dia. holes 1.3 35.4 (1.39) 40±0.2 50 max. (1.97) 19 20.3 21.5 max P3G-08 Back Connecting Socket 27 dia (1.06) Terminal Arrangement 45 (1.77) 45 (1.77) 4.9 (0.19) 17 (0.67) P2CF-11 Track Mounting/Front Connecting Socket Eleven M3.5 x 7.5 sems 7.8 (0.31) 3 (0.12) 4.5 (0.18) Terminal Arrangement Surface Mounting Holes Two, 4.5 dia. or two M4 socket mounting holes 70 max. (2.76) Two 4.5 dia. holes 35.4 (1.39) 40 ± 0.2 (1.57) 4 (0.16) 50 max. (1.97) 31.2 max. (1.23) 5

P2CF-11-E Finger Safe Terminal Type Conforming to VDE06/P0 Eight M3.5 x 7.5 sems 7.8 (0.31) 5 4.5 (0.18) 3 70 max. (2.76) Two 4.5 dia. holes 1.2 35.4 (1.39) 40±0.2 30 50 max. (1.97) 31.2 max P3GA-11 Back Mounting Socket 27 dia (1.06) Terminal arrangement (1.01) 16.3 (0.64) Y92A-48G Finger Safe Terminal for P3G(A) Conforming to VDE06/P0 Twelve, 6.4 dia. holes 34 47.7 x 4.47 48 x 48 16.5 27.6 47.4 Y92F-30 Mounting Adapter Adapter installs behind the panel. It is ideal for side by side installation. Use P3GA-11 or P3G-08 sockets. Panel Mounting adapter P3G- socket Panel cutout (2.28) 58 (1.77) 48 (1.89) (3.78) (1.77) Note: Recommended panel thickness is 1 to 3.2 mm. 6

Y92S-20 Battery for Memory Backup Use this battery with -XN M timers with memory protection circuit. While the timer's built-in memory protection circuit can retain values for power failures lasting up to minutes, the optional battery protects memory in case of a longer power outage. We recommend using the battery as a safeguard. Memory values can be retained for up to 5 years. 31.0 (1.2) Lead wire with spade lug 120 mm (4.72 in) length ( ) (+) 4.5 dia. hole Y92A-48B Hard Plastic Cover Y92A-48D Soft Plastic Cover Hard plastic cover Y92A-48B and soft plastic cover Y92A-48D snap onto the front of the timer to protect against dirt and water. The Y92A-48B hard plastic cover prevents accidental resetting. Y92A-48D soft plastic cover fits snugly over the front and allows settings to be changed. These covers are intended for use in areas where unusual service conditions do not exist. 50.5 (1.99) 50.5 (1.99) 16 (0.63) overall depth PFP-0N, PFP-50N Mounting Track PFP-0N2 Mounting Track 4.5 (0.18) 7.3±0.15 35±0.3 27±0.15 4.5 (0.18) 35±0.3 27 24 16 (0.63) 29.2 (1.15) 15 25 25 25 25 L L: Length 1 m PFP-0N 50 cm PFP-50N 1 m PFP-0N2 1 (0.04) 15 25 25 L 25 25 15 1 (0.04) 1.5 (0.06) PFP-M End Plate (0.39) 6.2 (0.24) 1.8 (0.07) PFP-S Spacer 5 (0.20) 16 (0.63) 12 50 (1.97) 11.5 (0.45) M4 x 8 pan head screw 1 1.8 1.3 (0.05) (.39) 4.8 (0.19) 35.5 35.3 (1.39) 44 (1.74) 16.5 (0.65) 34.8 (1.37) 7

Connections Part Input terminal number (no-voltage only) Power supply terminal numbers Output terminal numbers number COM Gate Reset AC (common), DC AC (hot), DC+ COM NC NO DC- DC+ - N 1 4 3 2 7 8 5 6 - S 1 4 3 2 7 8 6 - M 3 5 7 2 11 8 9 1 4 - N Timer - S Timer - M Timer Note: Internal (isolated) contacts are shaded. POWER SUPPLY - N and - S Timers - M Timers Connect the timer so that the supply voltage is For models with memory protection, connect applied to terminals 2 and 7. This is for models the supply voltage to terminals 2 and. without memory protection. CTROL OUTPUT Timed contact output type - N Terminals 5, 6 and 8 are used for the output relay. A normally open contact (Load 1) is connected between terminals 6 and 8. A normally closed contact (Load 2) is connected between terminals 5 and 8. 8

Timed Solid-state output type -X NS The solid-state output uses an open collector type transistor. Connect terminal 6 (collector) to the positive terminal of the load. Connect terminal 8 (emitter) to the negative terminal. A built-in surge suppression diode on terminal 5 should be connected to the positive terminal of the load when the timer switches an inductive load. Timed contact output with memory protection -X NM Terminals 8, 9 and 11 are used for the output relay. A normally open contact (Load 1) is connected between terminals 9 and 11. A normally closed contact (Load 2) is connected between terminals 8 and 11. INPUT REQUIREMENTS Contact Solid-State Resistance 1 KΩ max. Residual voltage 1 V max. when the contact makes Contact material Gold-plated contacts Note: Select a contact with short bounce time. Contact bounce causes an error in the operate time equal to bounce time. Input type Voltage when collector is Collector current Input current between collector and base Open collector transistor 20 V min. 50 ma min. 0.6 ma max. RESET INPUT Timers without memory protection -, - S Connect a no-voltage contact or an open collector transistor output to terminals 1 and 3. The timer resets when contact is made or when the transistor turns. Timers with memory protection -X NM Connect a no-voltage contact or an open collector transistor output to terminals 3 and 7. The timer resets when contact is made or when the transistor turns. 9

GATE INPUT Cumulative Timing Using the Gate Input with -Delay When the gate signal is closed, timing is temporarily stopped. When the gate signal opens, timing resumes at the point of interruption. The gate input terminal permits the timer to sum up times T 1, T 2 and T 3 as shown in the timing chart. Power supply [ Interruption Interruption Gate input [ T 1 T 2 T 3 Time up Digital display [ 0 1 2 3 3 4 5 6 7 7 8 9 Control output [ Preset time = seconds Timers without memory protection -, - S Connect a no-voltage contact or an open collector transistor output to terminals 1 and 4. The gate input interrupts timing when the contact closes or when the transistor is. Timing resumes from the point of interruption when the gate input is removed. Timers with memory protection - M Connect a no-voltage contact or an open collector transistor output to terminals 3 and 5. The gate input interrupts timing when the contact closes or when the transistor is. Timing resumes from the point of interruption when the gate input is removed. BATTERY FOR MEMORY PROTECTI Connect the Y92S-20 battery between terminals 1 and 4 on - M timers. The 3 V lithium battery is in a holder with lead wire and terminations. It may be used to preserve timer memory for power outages that are longer than minutes duration. Because power failure duration is unpredictable, we recommend using Y92S-20 for long-term memory back up. SIMULTANEOUS INPUT TO SEVERAL TIMERS For expanded convenience, input signal may be used to apply gate and reset signals to several timers. Also a combination of gate to some and reset to other timers is possible. Timers with and without memory backup may be used together. Pay attention to the different terminal numbers required for gate and reset when mixing timer types. Gate input, without memory protection Gate input, with memory protection

Simultaneous input to, continued Reset input, without memory Reset input, with memory protection Reset and gate inputs, without memory Reset and gate inputs, with memory protection Operation SETTING THE TIME PRESET Use the four pushwheel switches on the front panel to set the desired time. The timer does not display the decimal point. Firmly push the switches to avoid having two numbers appear in the display window. This causes the operating time to drift widely. Do not change the setting while the timer is powered up. It may cause a momentary output to occur. Undesirable settings 5 min 30 s? 25 min 30 s? 35 min 30 s? WARNING Do not set all four digits to zero. This causes a momentary output to occur that may lead to accidental injury or damage. Mounting PANEL MOUNTING Using Y92F-30 Adapter Insert the timer through the panel cutout. Push the Y92F-30 adapter from the rear of the timer as far forward toward the panel as possible. Push the P3G - socket onto the rear of the timer. Then wire the socket. Tighten the two retaining screws. To release the adapter, lift the tab at the rear of the adapter. 11

Using Y92F-30 Adapter (continued) Several timers may be panel mounted close together using Y92F-30 adapter as shown here. When mounting two or more timers in a vertical line, arrange the adapters so that their molded tabs are positioned on the right and left sides. When mounting two or more timers in a horizontal line, arrange the adapters so that their molded tabs are positioned on the top and bottom sides. Panel cutout for side-by-side mounting of two timers Molded tab Molded tab P2CF- Socket Mounting The P2CF- socket has two hooks that secure the timer to the socket. Be sure to allow at least 20 mm (0.79 in) clearance above and below the socket to gain access and to release the hooks for servicing and maintenance. Insert timer into the socket. Latch hooks. Then clip rear of the socket to the track. Push the bottom onto the track until the latch hooks securely. Removal Pull the latch on the socket with a flatblade screwdriver and remove the timer and socket as one unit. NOTE: DIMENSIS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMR ELECTRICS LLC OMR -LINE OMR CANADA, INC. One East Commerce Drive Global - http://www.omron.com 885 Milner Avenue Schaumburg, IL 60173 USA - http://www.omron.com/oei Scarborough, Ontario M1B 5V8 1-800-55-OMR Canada - http://www.omron.com/oci 416-286-6465 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice. Printed in the U.S.A. 12