ETH-4X1-G / 2X1-G / 2X1

Similar documents
USB-C5 USB-C5-CE USB EXTENDER Installation and User Guide

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

-C5RS-LC RS232 EXTENDER

XTENDEX Series ST-C5USBD FOOT DVI and USB Extender via CAT5e/6 Installation and Operation Manual

EXTENDERS Installation and Operation Manual

PRIMUX Series. PRIMUX-RDSW PRIMUX Redundancy Switch Installation and Operation Manual

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

ST-C5VA-WL500 WALL MOUNT VGA VIDEO AND STEREO AUDIO EXTENDER

NTI. VEEMUX Series. SM-nXm-15V-LCD. Video Matrix Switch Installation and Operation Manual. MAN067 Rev Date 5/14/2007

NTI. VEEMUX A Series. SM-nXm-AV-LCD. Audio/Video Matrix Switch. Installation and Operation Manual. MAN069 Rev Date 2/5/2014

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

VEEMUX Series. SM-nXm-DVI-LCD DVI Video Matrix Switch Installation and Operation Manual

NTI. VEEMUX Series. SM-nXm-15V-LCD. Video Matrix Switch Installation and Operation Manual. MAN067 Rev Date 10/26/2017

ST-C6USBH-300 ST-C6USBHU-300 ST-C6USBH-IR-300 ST-C6USBHU-IR FOOT USB, HDMI AND IR EXTENDER Installation and Operation Manual

VEEMUX Series. SM-4X4-DVI SM-8X8-DVI DVI Video Matrix Switch Installation and Operation Manual

UNIMUX-DVI-x NTI. USB DVI KVM Switch Installation and Operation Manual. UNIMUX TM Series NETWORK TECHNOLOGIES INCORPORATED. MAN007 Rev Date 1/04/2008

EXTENDERS Installation and Operation Manual

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

NTI. VEEMUX Series. SM-nXm-15V-LC. Video Matrix Switch Installation and Operation Manual. MAN156 Rev Date 4/26/2017

VOPEX Series VOPEX-C5VA-xC1000 Video/Audio Splitter/Extender Installation and Operation Manual

NTI. KEEMUX-P4-LC (4-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

1275 Danner Dr Aurora, OH KEEMUX-USBV-2U (2-Port USB KVM Switch) NTI NETWORK TECHNOLOGIES INCORPORATED

Wiring and Configuration Instruction

SM-nXm-C5AV-1000 Audio/ Video Matrix Switch via CAT5

ST-IPHD-L/R-2GOPOE HDMI Over Gigabit IP Extender with Power over Ethernet (POE) Installation and Operation Manual

VEEMUX Series. SM-nXm-DVI(A)-LCD DVI Video Matrix Switch Installation and Operation Manual

VOPEX NTI. PS/2 KEYBOARD, MONITOR & MOUSE SPLITTER Installation and Operation Manual. VOPEX Series NETWORK TECHNOLOGIES INCORPORATED

EXTENDERS Installation and Operation Manual

NTI. ST-nXm-USBV-U (Multi-user / USB KVM Switch) INSTALLATION / USER GUIDE MAN028 Rev Date 8/21/2002 R NETWORK TECHNOLOGIES INCORPORATED

UNIMUX TM Series. UNIMUX-DVI(A)-xHD. USB DVI KVM Switch Installation and Operation Manual

VOPEX Series. VOPEX-2/4KVIM-A VOPEX PS/2 KEYBOARD, MONITOR, and MOUSE SPLITTER Installation and Operation Manual

USB-SUN USB TO SUN ADAPTER Installation Manual

RS-232 Connector Pin Assignments

PRIMUX CAT5 KVM System Quick Start Guide

ENVIROMUX Series Installation Instruction For:

ST-C6USBH(E)-HDBT 328 FOOT HDMI USB KVM Extender over HDBaseT Installation and Operation Manual

DGH A3000 Configuration Guide For use with DGH Modules

NM-541-MUX TECHNICAL APENDIX V1.00

Low Profile Hub. User Manual

Mounting ears as received from NTI. Rear View of ENVIROMUX-S5VDC

XTENDEX Series. ST-IPHD-LC HDMI Over IP Extender Installation and Operation Manual

Installation and Operation Manual

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-808TP 8x8 Twisted Pair Matrix Switcher. P/N: Rev 1

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Contents. One Introduction 2. Two Installation 3 Front Panel Connecting Ports LEDs

Model UD2A-EDID DVI Extender with EDID Management, Serial & GUI Control

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

USB 2.0 RG port USB m Cat 5e Extender System. User Guide

VGA RS-232 Extender USER MANUAL.

ST-2FODVI-LC DVI Extender via Fiber Optic Cable Installation and Operation Manual

XPress DR+W Quick Start Guide

HI-RES VGA USB KVM EXTENDERS

ENVIROMUX-DCLM-6 DC Voltage and Current Monitor

Contents. One Introduction 2. Two Installation 3 Front Panel 10base-T Ports 10/100base-TX Ports LEDs

Transceiver Hub with Integral Camera Power

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12

Kramer Electronics, Ltd. USER MANUAL. Models: TP-125, UXGA / Audio / Data Line Transmitter TP-126, UXGA / Audio / Data Line Receiver

GigaSwitch 8. User Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Installation and User Guide

USB 400 USER MANUAL.

MDI/MDIX) FEP-32005T-2

HDMI (HDBaseT) Matrix Switcher Series

CNX MAINTENANCE INTERFACE PANEL

VOPEX Series VOPEX-USBV-2/4. USB Keyboard, Video, and Mouse Splitter/Hub Installation and Operation Manual. Front and Rear View of VOPEX-USBV-4

CAT EXT-CAT USER MANUAL.

Active UTP Transceiver Hub with Integral Isolated Camera Power

NPort 6150/6250 Series Quick Installation Guide

USB 2.0 Ranger High Speed Extender System. User Guide

CAT EXT-CAT USER MANUAL.

Kramer Electronics, Ltd. USER MANUAL. Model: TP Channel UXGA/Audio/RS-232 to CAT 5 Transmitter

Operation Manual of EX9132CST-Series

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Tel: Fax:

epowerswitch-8 Power Management Master Slave User's Guide

Lab - Building an Ethernet Crossover Cable

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Powerline Communication

ST-C5USBV-300 ST-C5USBVA FOOT USB KVM EXTENDER

Data Broadcast Switch

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

16/24-Port Gigabit Desktop Switch

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

BIPAC Broadband Firewall Router. Quick Start Guide

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

Simple Card Reader for Door Access & Time Attendance System. User Guide

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

Communication Wiring Color Codes

Kramer Electronics, Ltd. USER MANUAL. Model: VP-311DVI. Automatic DVI / Audio Switcher

Transcription:

VIDEO 1275 Danner Drive Aurora,Ohio 44202 PRODUCTS Tel: 1-800-626-7801 Fax: 330-562-1999 www.vpi.us INCORPORATED ETH-4X1-G / 2X1-G / 2X1 Manual Ethernet Switch Installation and Operation Manual MAN048 Rev Date 4/26/2017

COPYRIGHT Copyright 2002-2017 by orporated. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Video Products Incorporated, 1275 Danner Drive, Aurora, Ohio 44202 CHANGES The material in this manual is for information only and is subject to change without notice. Video Products Incorporated reserves the right to make changes in the product design without reservation and without notification to its users. i

TABLE OF CONTENTS Introduction... 1 Glossary... 1 Supported Device Types... 1 Supported Operating Systems... 1 Application Examples... 2 Materials... 3 Preparation for Installation... 3 Features and Functions... 4 Installation... 5 Connect the Cables... 5 Plug-in and Boot Up... 6 RS232 Control... 7 Remote Connection... 7 Command Protocol... 7 NTI Switch Control Program For Windows 9X, NT, 2000 AND XP... 8 SerTest- RS232 Interface Test Program... 8 Main Options... 8 Switch Operations... 8 Setup Options... 9 Technical Specifications... 9 Interconnection Cable Wiring Method- Straight Thru... 9 Interconnection Cable Wiring Method- Crossover... 10 Troubleshooting... 10 Warranty Information... 10 ii

INTRODUCTION The NTI ETH-4X1-G Manual Ethernet Switch was designed to enable the connection between a common DEVICE or NETWORK and one of up to four DEVICEs or NETWORKs using standard Ethernet cable. The ETH-4x1-G is a switch that provides reliable physical signal separation between connected devices while supporting 10Base-T, 100Base-T, and 1000Base-T connections. Push buttons on the switch provide easy user control over the ETH-4X1-G to make a single connection active between two Ethernet-based devices at a time. Available Options Manual Ethernet Switch with 2 user selectable connection ports rather than 4 (ETH-2X1-G) 2-Port Manual Ethernet Switch with support for only 10Base-T and 100Base-T connections.(eth-2x1) RS232 control to change connections in the Ethernet switch via a serial stream (ETH-4X1-RS-G or ETH-2X1-RS-G) Glossary CPU- Computer for user access DEVICE- CPU or other data entry/acquisition equipment NETWORK- Local Area Network (LAN)*, File server, DSL internet connection MDI- Media Dependent Interface MDIX- Media Dependent Interface Crossover - A DEVICE or NETWORK that is to be commonly connected to the selected NETWORK or DEVICE (up to 4) through the ETH-4X1-G Manual Ethernet Switch SELECTABLE- Any NETWORKs or DEVICEs (up to 4) that will be plugged into the user selectable ports (1-4) and connected to the through the ETH-4X1-G Manual Ethernet Switch *Note: The ETH-4X1-G Manual Ethernet Switch cannot differentiate between LANs and cable/dsl modems. For the purposes of this manual they will be considered to be identical. Supported Device Types Routers HUBS ETHERNET Switches (Managed / UN-managed) PC s Network Appliances IEEE 802.3 Supported Devices Supported Operating Systems Any IEEE 802.3 compliant operating system 1

APPLICATION EXAMPLES CPU DSL SERVER MODEM ROUTER CPU CPU CPU CAT5e/CAT6 UTP cable RJ45 male-male See "Note" on page 3 1 2 3 4 ETH-4X1-G - + 4 3 2 1 LAN CPU CPU CPU CPU 1 2 3 4 CAT5e/CAT6 UTP cable RJ45 male-male See "Note" on page 3 ETH-4X1-G - + 4 3 2 1 Cable Modem CPU CPU CPU CPU 1 2 3 4 CAT5e/CAT6 UTP cable RJ45 male-male See "Note" on page 3 ETH-4X1-G - + 4 3 2 1 2

MATERIALS Materials Supplied with this kit: NTI ETH-4X1-G / ETH-2X1-G Manual Ethernet Switch 120 VAC at 60 Hz / AC Adapter Materials Not Supplied, BUT REQUIRED: Ethernet Cables- Cat5e/Cat6 UTP cable with male-male connectors, either wired straight-thru or crossover, depending upon the connected component. See note below. Note: A crossover cable may be required if any connected components (NETWORK or DEVICE) do not support Auto MDI/MDIX cable selection. Once a component is properly connected and powered ON, a link LED should illuminate to indicate communication with another component. If it does not illuminate, a crossover cable may be required. See pages 9 and 10 for cable pinouts. PREPARATION FOR INSTALLATION A location should be chosen for the ETH-4X1-G such that the Ethernet cable from each supported device will reach it. The Ethernet cables must be run to the locations where the ETH-4X1-G switch,, and the SELECTABLE(s) will be mounted. Be careful to route the cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the signal (i.e. AC motors, welding equipment, etc.). A 120V electrical outlet must be available close enough to the mounting location of the ETH-4X1-G to plug the AC adapter into. All cables should be installed in such a way that they do not cause stress on their connections to the equipment. Extended lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to minimize this. 3

Front View of ETH-4X1-RS-G Rear View of ETH-4X1-RS-G NETWORK ETH-4X1-RS-G - + 4 3 2 1 RS232 1 2 3 4 R R ETH-4X1-RS-G - + 4 3 2 1 RS232 1 2 3 4 1 2 3 4 5 6 FEATURES AND FUNCTIONS 1. - male connection jack for the AC adapter 2. Port Select Switches- (1-4)- for manual control of ""* and user selectable ports (1-4) Note: ETH-2x1-G Switch has only 1 Port Select switch that toggles between ports when pressed. 3. RS232-9 pin DIN male (optional)- for computer control of ""* and user selectable ports (1-4) (only on models with RS232 option) 4. Status LEDs- for visual indication of switch connection between the ""* and the user selectable ports (1-4) 5. User Selectable Ports (1-4)- RJ45 female- for connection of SELECTABLEs* Note: ETH-2x1-G Switch has only 2 user selectable ports. 6. port- RJ45 female- for connection of * *See Glossary (page 1) for explanation of and SELECTABLE. 4

INSTALLATION Connect the Cables 1. Position the ETH-4X1-G such that the Ethernet cable from the, the AC adapter power cable, and the Ethernet cables from the SELECTABLEs can reach the ETH-4X1-G. 2. Connect one end of an Ethernet cable to the (See Fig.1.) Connect the other end of that cable to the "" port on the ETH-4X1-G. 3. Connect another Ethernet cable between each SELECTABLE and the user selectable ports (1-4) on the ETH-4X1-G. (See Figs.1 and 2.) Rear View of CPU (DEVICE) Rear View of ETH-4X1-G R NETWORK 4 3 2 1 R ETH-4X1-G - + RJ45 Female 1 2 3 4 RJ45 Female RJ45 Male RJ45 Male Ethernet Cable See note under Materials on page 3 RJ45 Ethernet Cable to device (NETWORK) Rear View of ETH-4X1-G Figure 1- Connect DEVICE to switch ETH-4X1-G - + 4 3 2 1 Cable Modem (NETWORK) R R NETWORK RJ45 Female 1 2 3 4 RJ45 Female RJ45 Male RJ45 Male Ethernet Cable See note under Materials on page 3 RJ45 Ethernet Cable to device (DEVICE) Figure 2- Connect NETWORK to switch 5

Plug-in and Boot Up 1. Connect the AC adapter power connector to the port on the ETH-4X1-G. Make sure the power connector is properly inserted. (See Fig. 3.) 2. Plug the AC adapter into a power outlet. The status LED for SELECTABLE port 1 will illuminate indicating a proper power connection has been made. Note: An illuminated Status LED also indicates a connection between the "" port and the associated user selectable port. Front View of ETH-4X1-RS-G 1 2 3 4 Barrel (Outside barrel) Power Connector @ OUTPUT 2.1 mm x 5.5 mm Female 5 VDC Adapter ADAPTER (Inside barrel) NETWORK R ETH-4X1-RS-G - + 4 3 2 1 RS232 R Status LEDs DB9 Male RS232 Connector Figure 3- Connect the AC adapter 3. Power up the and SELECTABLE device(s). The device should react as if it were directly connected to the SELECTABLE device plugged into user selectable port 1. 6

RS232 Control RS232 (optional) enables the ETH-4X1-RS-G to be remotely controlled via RS232. To control the ETH-4X1-RS-G via RS232 the user has three options: write a program that runs on a PC using the Command Protocol (below) use the NTI Switch Control Program (page 8) provided on the CD use the SerTest program (page 8) provided on the CD Remote Connection The RS232 Interface is designed to control the switch via serial (RS232) connection from any host computer or other controller with an RS232 communications port. To use the RS232 port, connect a crossed female serial cable from a CPU serial port to the DB9 pin male RS232 port on the ETH-4X1-RS-G. Connections are as follows: RS232 Connector (DB9 Male) Pins at Signal ETH-4X1-RS-G Pins at CPU 2 RxD 3 3 TxD 2 5 GND 5 RS232 program setup parameters: 9600 baud 8 bit data 1 stop bit no parity no flow control "RS232" Connector 1 2 3 4 5 6 7 8 9 Mating Face of DB9 Male Command Protocol CPU controller commands supported by the unit are defined below. Commands may be sent using any RS232 communication program (i.e. Windows HyperTerminal). All commands should be terminated with a <CR> (carriage return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the command definitions table below. All characters in the command string should be upper case, and all numbers below 10 should have a leading 0 (ex: 1 = 01). As command strings are sent, the inner character delay cannot exceed 500 milliseconds. The following commands are supported. LEGEND ALL NUMBERS MUST BE TWO DIGITS SW: SWITCH UNIT ADDRESS- this is 01 and cannot be changed) OP: OUTPUT () PORT -this is 01 and cannot be changed IP: INPUT NETWORK PORT (01-MAXINPUTS) (MAXINPUTS = 02 or 04) <CR>: CARRIAGE RETURN (Hex 0x0D) Command String Good Response Description CS SW,IP,OP *<CR> Connect Port To Input/SELECTABLE Port RO SW,OP *<CR>IP<CR> Read Connection For Output/ Port RU SW *<CR>IP,OP<CR> Read Unit Size RV SW,00 *<CR>string\0<CR> Read NTI Version String (Short Version) RV SW,01 *<CR>string<CR> Read NTI Version String (Long Version) If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch memory (01), the command will be ignored. If the SW field corresponds to the unit address, but the syntax is wrong after this field, the switch will answer with a bad response?<cr>. 7

NTI Switch Control Program For Windows 9X, NT, 2000,Vista, XP, 7, 8 AND 10 The NTI Switch Control Program is an easy and powerful graphical program that controls NTI switches through an RS232 interface. The NTI Switch Control Program can be downloaded from https://www.vpi.us/network-devices/gigabit-ethernet-switch- 1044. To install the NTI Switch Control Program after downloading it to your computer from the manual CD: 1. Locate the Setup.exe in the directory the program was downloaded to and double-click on it 2. Follow the installation instructions on the screen The NTI Switch Control Program performs best on monitors set to a screen resolution of at least 800 X 600. Instruction for using the NTI Switch Control Program is available by opening "MSCP Help" in the "NTI" program group once the program has been installed and is open on the screen. To open "MSCP Help" from the Windows desktop: 1. Click on START 2. Click on PROGRAMS 3. Click on NTI 4. Click on MSCP Help SerTest- RS232 Interface Test Program This software allows a user to test the functions of an NTI server switch, matrix switch, Ethernet switch, or Multi-user/Multiplatform switch RS232 interface. The program SERTEST along with the NTI Switch Control Program (above) is installed from the CD packaged with this switch. SERTEST generates a main menu with the 4 selections described below: Main Options Switch Operations - send commands to the ETH-4X1-RS-G Ethernet Operations - set Ethernet connection variables (not applicable to this switch) Setup Options - set COM port, baud rate, and unit address About SerTest - display the program version Switch Operations Key Selection Description 1) Connect Video Output/User to an Input/CPU - connect an output () to an input(selectable) 2) Connect All Video Outputs/Users to an Input/CPU - connect all outputs to an input 3) Connect Audio Output/User to an Input/CPU - connect an output to an input (audio ports only) 4) Connect All Audio Outputs/Users to an Input - connect all outputs to an input (audio ports only) 5) Change Mute Status for Audio Output/User (not - mute or un-mute the Audio port output applicable to this unit) 6) Change Volume for Audio Output/User (not - change Audio port output volume applicable to this unit) 7) Read Connection for Video Output/User -read the connection of a specific video output ( (01)) 8) Read Connection for Audio Output/User -read the connection of a specific audio output 9) Read Mute and Volume for Audio Output/User - read the volume and the mute status of the specified audio output a) Save I/O Connections into Unit Memory -save the connections into switch memory bank b) Restore I/O Connections from Unit Memory -restore the connections from switch memory bank c) Change All Units Baud Rate (9600/COM1:) -change RS-232 Baud rate of all switches -the current baud rate and serial port are displayed in parentheses d) Reset Unit - send a reset command to the switch - the current unit address is displayed in parentheses e) Reset All Units - send an internal reset command to all switches f) Read Unit Size - read the switch size (number of inputs and outputs) g) Read Unit Version/Revision String -read a string containing the switch version, type, and size h) Save All Units I/O Connections into Units Memory -save the connections into switch memory bank, command for all switches i) Restore All Units I/O Connections from Units Memory -restore the connections from switch memory bank, command for all switches Selections in the "Key" column that are gray are not applicable to this product. 8

Setup Options Key Selection Description 1) select Com port current: (COM1:) - select PC serial port - the current PC serial port is displayed in parentheses 2) select Baud rate current: (9600) - select PC serial port baud rate - the current baud rate is displayed in parentheses 3) set unit Address current: (1) - select the unit address - the current address is displayed in parentheses For any selection that requires user input, the user is prompted. When commands are sent to the switch, the command string and switch responses are echoed to the screen. All commands generated by the program are formatted according to the information provided in sections above. If any transmission problems are detected, an error message is displayed. Press <Esc> or <Enter> to back out to the main menu and press again to exit. TECHNICAL SPECIFICATIONS Interconnect Cable CAT5e/CAT6 UTP Male-Male cables (see note under Materials on page 3) Power 120VAC @ 60Hz / AC Adapter (provided) ETH-4X1-G current draw < 0.2A @ Dimensions WxDxH (in.) 5.25 x 4.375 x 1.375 Interconnection Cable Wiring Method- Straight Thru In order to make a direct connection between two devices that support Auto MDI/MDIX, a cable wired straight-thru can be used. The cable is made with CAT5e/CAT6 UTP cable terminated with male RJ45 connectors and wired according to the EIA /TIA 568A industry standard. Both ends are wired is as per the table and the drawing below. Pin # Wire Color 1 White/Orange 2 Orange 3 White/Green 4 Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown 9

Interconnection Cable Wiring Method- Crossover In order to make a direct connection between two devices that do not support Auto MDI/MDIX, a crossover cable must be used either at the SELECTABLE port end or at the port. The cable is made with CAT5 cable terminated with male RJ45 connectors and wired according to the EIA /TIA 568A industry standard. The cable is wired according to the chart below. Pin assignment at Standard End Wire Color Pin assignment at Crossed End 1 White/Orange 3 2 Orange 6 3 White/Green 1 4 Blue 4 5 White/Blue 5 6 Green 2 7 White/Brown 7 8 Brown 8 Standard End Crossed End Crossover Cable TROUBLESHOOTING Each and every piece of every product produced by is 100% tested to exacting specifications. We make every effort to insure trouble-free installation and operation of our products. If problems are encountered while installing this product, please look over the troubleshooting chart below. If an answer is not found in the chart, check the FAQs (Frequently Asked Questions) at our website at http://www.vpi.us or contact directly for help at 800-626-7801 in US & Canada or 330-562-2622 (worldwide). We will be happy to assist in any way we can. Problem Cause Solution Status LEDs do not illuminate Power supply is not connected or plugged-in. Make sure outlet is live and AC adapter is plugged in. Also make sure power jack is NETWORKS(s) will not communicate with DEVICE(s) (no link light(s) ON) Poor Connection Wrong Ethernet cable fully connected to the switch. Make sure all Ethernet cables are inserted completely, snapping into RJ45 sockets Cable must be CAT5e/6 - see note under Materials on page 3 WARRANTY INFORMATION The warranty period on this product (parts and labor) is one (1) year from the date of purchase. Please contact Video Products Incorporated at (800) 626-7801 or (330) 562-2622 for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns. Man048 Revised 4/26/2017 10