Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Similar documents
Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc.

TABLE OF CONTENTS. Introduction... 1

CIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1

4. Specifications and Additional Information

CIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1

CIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1

DBK24. Isolated Digital Output Chassis. Overview

Gateway Ascii Command Protocol

PowerPrism16 Light Controllers Instruction Guide

CIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1

ECHO Process Instrumentation, Inc. Modbus RS485 Module. Operating Instructions. Version 1.0 June 2010

CIS-331 Exam 2 Fall 2014 Total of 105 Points. Version 1

RS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out.

ZN-DN312XE-M Quick User Guide

MAXIMA + Series ROTARY LEVEL CONTROL

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

CIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MAXIMA + Series ROTARY LEVEL CONTROL

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Hybrid AC Driver [GCNC-1110]

MAXIMA+ Series Rotary Level Indicator

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Model DMX8DIM Installation and Operations Manual

TOKISTAR LIGHTING INSTRUCTION MANUAL

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

CIS-331 Final Exam Spring 2018 Total of 120 Points. Version 1

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

CIS-331 Final Exam Spring 2015 Total of 115 Points. Version 1

OWNER'S MANUAL DIMMERMASTER 1224 DIGITAL DIMMER

USB-ASC232. ASCII RS-232 Controlled USB Keyboard and Mouse Cable. User Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

The cache is 4-way set associative, with 4-byte blocks, and 16 total lines

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

RTD SAMPLER OPERATOR S MANUAL

APPLICATION NOTE VACUUM FLUORESCENT DISPLAY MODULE

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage XF Series

AEXX-349 SERIES REMOTE DISPLAYS

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

IP67. Luminux Matrix RGB LED Panel. Luminux Matrix RGB LED Panel - LED Space and Diffuser Distance Guide.

iconverter 2-Module Power Chassis

Resolver to Digital Expansion Board

Vocia ELD-1. Operation Manual

Instruction Manual Series 46 PoE Ethernet Fiber Optic Transceivers

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

DCM Digital Control Modules

SCD96 DMX Output Interface. Installation guide

DC425 NEMA 4X Analog Output Transducers

CDR File Information. Comments Direct PCM

I/O Expansion Box Installation & Operator s Instruction Manual

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VA-8xl 8-Channel Balanced Stereo Audio Amplifier. P/N: Rev 1

C1098 JPEG Module User Manual

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

Acquirer JCB EMV Test Card Set

User Guide. Control Box. RoscoLED TM.

OPAL-RT FIU User Guide.

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

VADDIO /CANON BU-SERIES PTZ CAMERAS

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

SMD Series Integrated Stepper Driver and Motor Revision 1.3

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

EDITION : 02/01/07 DN

User s Guide. POWERVAR Single Phase Power Conditioners

PRO-DVI-CAT. DVI over Single CAT5 Extender. User Manual. Made in Taiwan

USER MANUAL. BBB36+ Beagle Bone Black Cape/ Standalone Lighting Controller

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Basketball Shot Clock Set LX2180 Manual

Wallstations for use with Grafik 3000 and 4000 Series Systems

Digital Projector X30N/X35N

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

USER MANUAL. Kramer Electronics, Ltd. Models:

Tempco Instruction Manual

DMX36 USER MANUAL Features Revision 1 Suits PCB revision June, 2014

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

MODEL No. SW1X8 RS422 SWITCHER

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page

ETC Installation Guide

PRODUCT DATA SHEET. Linear Illuminator EXOLIGHT PRODUCT FEATURES PRODUCT APPLICATIONS. MetaBright Series

DP-222Q Color Video Door Phone Manual

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

MIDI-Scope. Artistic Licence Engineering Ltd. Software Version V1.3 Manual Revision V1.91

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

First Data Dual Interface EMV Test Card Set. Version 1.20

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

KBMG MULTI-SPEED BOARD

SAVE THESE INSTRUCTIONS

Transcription:

Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems, Inc. USER'S MANUAL PD405DMXUM

PD405DMX24DC User's Manual Page PD405DMX unit includes a PP405DMX open frame module mounted inside an aluminum enclosure with 2 RJ45 connectors for control DATA input and output. The technical descriptions and wiring diagrams are the same as the PP405DMX except for the control DATA connections. GENERAL DESCRIPTION The PP405DMX is a 4channel DMX52 compatible dimmer pack. It is equivalent to four solidstate relays (SSR's) and a DMX52 Logic assembled on a single circuit board. Power is fed to the PP405DMX from FOUR 5 Amps. DC Voltage Power Supplies. Each solid state relay is rated for a maximum output current of 5 amperes. The PP405DMX has an open frame U shaped enclosure. The logic signals are opticallyisolated from all line voltage elements. An external stepdown The DMX52 control cable is hardwired to the PP405DMX. Several Dimmer packs may be daisychained together. Each PP405DMX may be easily set to a unique address with 2 hexadecimal selectors and will occupy the next four DMX control channels beginning with the one following the address selected. When two or more units are set to the same address, their respective outputs work in unison, increasing the amount of load that can be controlled by a single DMX channel. Each of the PP405DMX outputs may be independently configured not to dim. In such case, a DMX input value greater than 3 switches its respective output to 00%, else the output remains at 0%. DIMMING/SWITCHING (See Page 0 for more information) A PP405DMX may control a combination of dimmed and switched loads. Each of the PP405DMX s outputs may be independently configured not to dim. This is achieved using a HARDWARE lock ( Jumper )to ensure circuits do not dim. Please see Page 7 for location of these jumpers. 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

PP405DMX Detail PD405DMX24DC User's Manual Page 2 Figure PP405DMX Detail CH CH 2 CH 3 CH 4 6 9 20 2 22 7 5 2 2 3 3 4 8 S2 6 5 9 8 7 S3 S 4 0 Table INPUT / OUTPUT Terminals Definition NAME DESCRIPTION CH INPUT / OUTPUT Of SolidState Relay # CH 2 INPUT / OUTPUT Of SolidState Relay #2 CH 3 INPUT / OUTPUT Of SolidState Relay #3 CH 4 INPUT / OUTPUT Of SolidState Relay #4 Negative side switches, Common Positive Table 2 Absolute Maximum Electrical Ratings Electrical Characteristic TerminalMaximum Relay Load Current to 4 5 Amps. Input Current to 4 5 Amps. Input Voltage 8 to24 VDC PP405DMX24DC Table 3 PP405DMX Circuit Legend Microprocessor. 2 Not used 3 Communications Chip. 4 Quartz Crystal. 5 Power Supply Capacitor. 6 Voltage Regulator. 7 DMX52 DATA connector. 8 Logic power connector 9 Output LED Monitors. 0 Jumpers for switches only,2,3,4 Optical Couplers #,2,3,4 5,6,7,8 MOSFET #,2,3,4 9,20,2,22 Fuse 5mm,5 AMPS fast blow SS2 Address Selectors. S3 Hi address Jumper ( 257 to 52 ) 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

PD405DMX Control Wiring Figure 4 PD405 DATA Network Ports Connections. PD405DMX24DC User's Manual Page 3 DMX52 control ports J Data J2 Data Bottom View Terminal 7 PP405DMX Pin 2 3 4 5 6 7 8 (J) (J2) DATA DATA +DATA +DATA 8 RJ45 J DATA BUS PD SERIES DATA LINK Patch or cross CAT5 cables could be used with the PD405DMX24DC because the DATA is connected to the 4 th pair only ( brown and brown white) 8 RJ45 J RJ45 Female Connectors Figure 5 Typical Installation DMX CONTROL EQUIPMENT PD405DMX PD405DMX PD405DMX To more DMX Equipment CAT5 cable with RJ45 termination 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. PD405DMXUM

PD405DMX24DC User's Manual Page 4 Enclosure Installation Surface mount the dimmer pack in a well ventilated area where the ambient temperature does not exceed 04 F for full load operation. Allow 2" of side clearance for proper air circulation and servicing. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawings below (FIGURE 6) for the correct dimensions. Conduit shall be pulled to the top of the dimmer packs.. (28mm) 4.6 (7 mm) 2.4" (6 mm) /2 and 3/4 Conduit Knockouts 2.4 (6 mm) Top View 3.2.9" (82 mm) (48 mm) Control DATA Connectors J Data DMX52.25 (32 mm) Bottom View.40 " (36 mm) J2 Data DMX52.80 (46 mm) 3. (79 mm) 8.5 (26 mm) Ch: Ch: 2 Ch: 3 Ch: 4.2 (285 mm) PP405DMXxxDC PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack DMXDC V.0 www.digitallighting.com Digital Lighting Systems, Inc. 4.6" (7 mm) RJ45 Data Bus Connectors PD405DMX Front Cover Figure 6 PD405DMXDimensional Diagram 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

PD405DMX24DC User's Manual Page 5 Figure 7 PP405DMX24DC GENERAL WIRING INSTRUCTIONS: Wiring Notes DO NOT EXCEED 20W @ 24 VDC or 60 W @ 2 VDC (5 Amps. ) per dimmer output All wiring between the controller and other dimmers (DATA bus) is low voltage (NEMA Class 2) and may be run with One, twisted pair, shielded #22 AWG wire. PP405DMXdimmer Modules may be fed by 4 Class 2 Power supplies CAUTION: DO NOT attempt to parallel outputs to increase capacity. Installation must conform to local and/or NEC code requirements and must be performed by a qualified electrician. Power supply # IN OUT + Ch: Ch: 2 Ch: 3 Ch: 4 5 A. Fuse Power supply # 2 IN OUT + Power supply # 3 IN OUT + 5 A. Fuse 5 A. Fuse Power supply # 4 IN OUT + 5 A. Fuse Common POSITIVES ( Anodes ) Switched NEGATIVES ( Cathodes) For class 2 compliance USE 4 independent power supplies Maximum 5 Amps or 00 watts Voltage range: 6VDC < V in < 24 VDC TYPICAL CHANNEL CONNECTION 2 PP405DMX24DC Optocouplers 2 3 4 S2 DMXDC V.0 Microprocessor 023456789ABCDEF D 023456789ABCDEF RS485 Communication S Channel Indicators D + High address 3 4 6 VDC to 24 VDC IN LOAD + + + 2 3 4 + + TERMINAL # = INPUT (Negative ) 2 = INPUT +(Positive ) 3 = OUTPUT + ( Positive ) 4 = OUTPUT ( Negative ) Violet + DATA DMX52 DATA BUS Red DATA Data Bus connects to other DMX52 components 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

User's Manual Page 6 PD405DMX24DC DMX Address Setting Up to 28 PP405DMX dimmer packs may be installed per system and their DMX input daisychained using standard DMX52 cables. Different addresses ranging from to 509 may be selected for each dimmer, depending on which DMX channel(s) will be used to control it. Each dimmer pack uses four consecutive DMX bytes from the input stream beginning at the address selected using rotary selectors S, S2 and address expansion jumper S3. (See Figure 3 on page 2 for selectors location). The PP405DMX is shipped from the factory with jumper S3 installed allowing a DMX address range between and 256 to be selected by S & S2 (See Table 4). For higher addresses ( 257509) jumper S3 must be removed (See Table 5). NonDim Output Setting Any or all of the PP405DMX outputs may be configured for nondim (switch only) operation. This prevents inadvertent dimming, or damage, of loads that cannot be dimmed, such as contactors, mechanical relays, motors, nondim fluorescent, etc... Since this procedure involves adding external wire jumpers to the INT4 board, it is preferable to have it performed by the factory, at time of order. However, a qualified electronic technician can perform the procedure in the field when necessary. Figure 8 shows the location for installing the nondim (ND) jumpers. The numbers shown next to the ND jumpers represent the corresponding output number of the PP405DMX. Installing an ND jumper makes the corresponding output nondim (switch only). A DMX value greater than 3 turns a nondim output to full intensity. A DMX value of 3 or less turns it fully off. BEFORE ENERGIZING THE PP405DMX MAKE SURE: Loads are tested before connecting to dimmers. PP405DMX has been properly grounded. All line voltage screw terminals are properly tightened to prevent hot spots. Low voltage data lines connections are properly insulated. Low voltage data lines polarity is observed throughout the system. The PP405DMX is set to the right address. PP405DMX Installation Check List 2 PP405DMX Optocouplers 3 2 3 4 S2 DMXD V4.2 Microprocessor 023456789ABCDEF 023456789ABCDEF D RS485 Communication S3 S Channel Indicators D + High address ND ND2 ND3 ND4 4 Channel 4 Channel 3 Channel 2 Channel Address Expansion Jumper (S3) S3 Installed (S2,S) Address Range: 256 S3 Removed (S2,S) Address Range: 257509 NonDim Jumpers NDND4 Installed Removed Output Is NonDim (Switch Only) Normal Dimmer Output. Unit is shipped without ND jumpers. Figure 8 PP405DMX Address & Mode Selection. 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

User's Manual Page 7 PD405DMX24DC PP405DMX Address Selection Information Table 4 Addresses 256 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S 00 33 20 65 40 97 60 29 80 6 A0 93 C0 225 E0 2 0 34 2 66 4 98 6 30 8 62 A 94 C 226 E 3 02 35 22 67 42 99 62 3 82 63 A2 95 C2 227 E2 4 03 36 23 68 43 00 63 32 83 64 A3 96 C3 228 E3 5 04 37 24 69 44 0 64 33 84 65 A4 97 C4 229 E4 6 05 38 25 70 45 02 65 34 85 66 A5 98 C5 230 E5 7 06 39 26 7 46 03 66 35 86 67 A6 99 C6 23 E6 8 07 40 27 72 47 04 67 36 87 68 A7 200 C7 232 E7 9 08 4 28 73 48 05 68 37 88 69 A8 20 C8 233 E8 0 09 42 29 74 49 06 69 38 89 70 A9 202 C9 234 E9 0A 43 2A 75 4A 07 6A 39 8A 7 AA 203 CA 235 EA 2 0B 44 2B 76 4B 08 6B 40 8B 72 AB 204 CB 236 EB 3 0C 45 2C 77 4C 09 6C 4 8C 73 AC 205 CC 237 EC 4 0D 46 2D 78 4D 0 6D 42 8D 74 AD 206 CD 238 ED 5 0E 47 2E 79 4E 6E 43 8E 75 AE 207 CE 239 EE 6 0F 48 2F 80 4F 2 6F 44 8F 76 AF 208 CF 240 EF 7 0 49 30 8 50 3 70 45 90 77 B0 209 D0 24 F0 8 50 3 82 5 4 7 46 9 78 B 20 D 242 F 9 2 5 32 83 52 5 72 47 92 79 B2 2 D2 243 F2 20 3 52 33 84 53 6 73 48 93 80 B3 22 D3 244 F3 2 4 53 34 85 54 7 74 49 94 8 B4 23 D4 245 F4 22 5 54 35 86 55 8 75 50 95 82 B5 24 D5 246 F5 23 6 55 36 87 56 9 76 5 96 83 B6 25 D6 247 F6 24 7 56 37 88 57 20 77 52 97 84 B7 26 D7 248 F7 25 8 57 38 89 58 2 78 53 98 85 B8 27 D8 249 F8 26 9 58 39 90 59 22 79 54 99 86 B9 28 D9 250 F9 27 A 59 3A 9 5A 23 7A 55 9A 87 BA 29 DA 25 FA 28 B 60 3B 92 5B 24 7B 56 9B 88 BB 220 DB 252 FB 29 C 6 3C 93 5C 25 7C 57 9C 89 BC 22 DC 253 FC 30 D 62 3D 94 5D 26 7D 58 9D 90 BD 222 DD 254 FD 3 E 63 3E 95 5E 27 7E 59 9E 9 BE 223 DE 255 FE 32 F 64 3F 96 5F 28 7F 60 9F 92 BF 224 DF 256 FF Table 4 PP405DMX Decimal to Hexadecimal Address Chart. Address Selection Chart Using S2S with JUMPER 3 INSTALLED 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

PD405DMX24DC PP405DMX Address Selection Information Table 5 Addresses 257509 User's Manual Page 8 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S 257 00 289 20 32 40 353 60 385 80 47 A0 449 C0 48 E0 258 0 290 2 322 4 354 6 386 8 48 A 450 C 482 E 259 02 29 22 323 42 355 62 387 82 49 A2 45 C2 483 E2 260 03 292 23 324 43 356 63 388 83 420 A3 452 C3 484 E3 26 04 293 24 325 44 357 64 389 84 42 A4 453 C4 485 E4 262 05 294 25 326 45 358 65 390 85 422 A5 454 C5 486 E5 263 06 295 26 327 46 359 66 39 86 423 A6 455 C6 487 E6 264 07 296 27 328 47 360 67 392 87 424 A7 456 C7 488 E7 265 08 297 28 329 48 36 68 393 88 425 A8 457 C8 489 E8 266 09 298 29 330 49 362 69 394 89 426 A9 458 C9 490 E9 267 0A 299 2A 33 4A 363 6A 395 8A 427 AA 459 CA 49 EA 268 0B 300 2B 332 4B 364 6B 396 8B 428 AB 460 CB 492 EB 269 0C 30 2C 333 4C 365 6C 397 8C 429 AC 46 CC 493 EC 270 0D 302 2D 334 4D 366 6D 398 8D 430 AD 462 CD 494 ED 27 0E 303 2E 335 4E 367 6E 399 8E 43 AE 463 CE 495 EE 272 0F 304 2F 336 4F 368 6F 400 8F 432 AF 464 CF 496 EF 273 0 305 30 337 50 369 70 40 90 433 B0 465 D0 497 F0 274 306 3 338 5 370 7 402 9 434 B 466 D 498 F 275 2 307 32 339 52 37 72 403 92 435 B2 467 D2 499 F2 276 3 308 33 340 53 372 73 404 93 436 B3 468 D3 500 F3 277 4 309 34 34 54 373 74 405 94 437 B4 469 D4 50 F4 278 5 30 35 342 55 374 75 406 95 438 B5 470 D5 502 F5 279 6 3 36 343 56 375 76 407 96 439 B6 47 D6 503 F6 280 7 32 37 344 57 376 77 408 97 440 B7 472 D7 504 F7 28 8 33 38 345 58 377 78 409 98 44 B8 473 D8 505 F8 282 9 34 39 346 59 378 79 40 99 442 B9 474 D9 506 F9 283 A 35 3A 347 5A 379 7A 4 9A 443 BA 475 DA 507 FA 284 B 36 3B 348 5B 380 7B 42 9B 444 BB 476 DB 508 FB 285 C 37 3C 349 5C 38 7C 43 9C 445 BC 477 DC 509 FC 286 D 38 3D 350 5D 382 7D 44 9D 446 BD 478 DD 50 N/A 287 E 39 3E 35 5E 383 7E 45 9E 447 BE 479 DE 5 N/A 288 F 320 3F 352 5F 384 7F 46 9F 448 BF 480 DF 52 N/A Table 5 PP405DMX Decimal to Hexadecimal Address Chart. Address Selection Chart Using S2S with JUMPER 3 REMOVED 2302 SW 28 th Court # 05, Miami, Fl. 3386 Tel: 3059698442 Fax: 3059696785 PD405DMXUM

LIMITED WARRANTY Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty. Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state. Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective. No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory. Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission. Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems. Defective merchandise may be returned to Digital Lighting Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting Systems distributor, representative, or: Digital Lighting Systems, Inc. Attn: Customer Service Department 2302 Sw 28th ct, #05 Miami, FL 3386 (305)9698442 Sales@digitallighting.com Digital Lighting Systems, Inc. 2302 Sw 28th Court, # 05 Miami, FL 3386 www.digitallighting.com Tel 3059698442 Fax 3059696785 em info@digitallighting.com Printed in U.S.A. 04 / 2008