Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Similar documents
CM-110SK Standalone Keypad Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Access Control

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Single Door Standalone Access Control User Manual

Digital Keypad Introduction

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

AS Keypad User Manual

Waterproof. Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

W3-M. Metal waterproof standalone access control/reader. User Manual

Fast operation of IP Villa System V 1.0

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

CM-500 SK 500 USER CODES KEYPAD

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

HSY-S209 EM Metal waterproof access control system User Manual

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

BC Digital Keypad. User Manual

FTK5 PROXIMITY KEYPAD

9212i INSTALLATION. Stand-Alone Keypad. Instructions

GV-AS Controller. Installation Guide

EL-ST100 KEYPAD CONTROLLER

CV-945 Stand-Alone Biometric Reader. Installation Instructions

User Manual. PCKeypad Wireless Keypad

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

VIDI-AC-2CS Access Controller/ Reader

DOLXFD1000B. Waterproof Access Control/Reader

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

GV-AS/EV Controller. User s Manual

PA5000 SERIES USER MANUAL

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

SYRIS SY110SA. Operating Manual. Ver:1.60

Fingerprint Identification Proximity Reader. Quick Installation Guide

RBR-SB-KTZ001 LAR 2. User Manual

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

OEM Proximity Reader with Keypad Manual REV1

1. Product Specification

User Manual. Split access control with intelligent secured power supply.

180 Series Keypad. Handbook. Revision 2.1

B100-SA Standalone Biometric Reader

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Quick Start Guide. GV-CS1320 Camera Access Controller

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

DG-800 Stand-Alone Proximity Reader Instruction Manual

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Specifications: Features:

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Stand-alone Proximity Access Control

Wi-Card Skeet-Trap Claymate Operator and User Manual

RFID/Digital Access Control Keypad

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

716 Converter. Programmable Data Converter

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Fingerprint Access Control F1. User Manual

Aceprox FSK Proximity Reader REV2 Data Sheet

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

mifare ID Reader with Selectable Outputs Data Sheet

Revision Date: 02 Mar 2018

Outdoor Stand-Alone Weatherproof Keypads

GV-EL124S Electric Strike

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Installing Keypad and Backplate

Two Door Controller GEN-045

With INTRATONE, you can easily secure all kinds of access points. You choose the management mode

CC Series metal access control Manual

Connecting a Cisco Reader Module

ACTpro Single Door IP Controller. Operating & Installation Instructions

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

212iL Rev. 1.1

INSTALLATION INSTRUCTION MANUAL

B100PROX-MF-SA Standalone Biometric Mifare Reader USER S MANUAL. Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT )

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

UC-2000 Installation Manual Unicorn Computers Technology Limited

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

Parrot MULTICOMM For Mitsubishi steering wheel

4 Channel DMX Driver Instruction Manual

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

Wiring Instructions v3

2000 Series e/em Style Keypad Installation and Programming Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Model # Date Wiring Diagram # Door No. #

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

Suprex RS-485 SPX-7500 Wired Reader-Extender

the Interactive Catalog

Transcription:

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader www.grantsautomation.com.au grant@grantsautomation.com.au

Wiring Diagrams for MAW6 Digital Keypad For Pedestrian Gates fitted with an electric Strike Lock or magnetic Lock Maw6 Digital Keypad/Touch Tag Reader BuzzA Pink BuzzB Pale Blue WG DO Green WG D1 White Alarm Grey Exit P/B Yellow or In Brown 9 to 28VDC Red Black NO Blue COM Purple NC Orange Alarm Exit Electric Strike Lock 12VDC Magnetic Lock 12VDC 12VDC Power Supply Can be unregulated with an output between 9V and 28VDC or Exit Button will activate the Devices output timer in the same manner that entering a correct code or touching a programmed tag or card does. Ideal as a way for pedestrians to exit without a code. or In is for a magnetic reed or micro switch fitted to a gate to activate an alarm if not closed in 1 minute after use. For 12V Automatic Gate Operator or 240V Operator with 12VDC output for accessories. BuzzA Pink Maw6 Digital Keypad/Touch Tag Reader BuzzB Pale Blue WG DO Green WG D1 White Alarm Grey Exit P/B Yellow or In Brown 9 to 28VDC Red Black NO Blue COM Purple P/B in P/B com 12V out Automatic Gate Operator Control Board NC Orange

Wiring Diagrams for MAW6 Digital Keypad For 24V Automatic Gate Operator or 240V operator with 24VAC or DC output for accessories. Maw6 Digital Keypad/Touch Tag Reader BuzzA Pink BuzzB Pale Blue WG DO Green WG D1 White Alarm Grey Exit P/B Yellow or In Brown 9 to 28VDC Red Black NO Blue COM Purple NC Orange P/B in P/B com 24V~ out 24V~ in 12V out Automatic Gate Operator Control Board VC12V Voltage Converter For Access Control/Alarms system Maw6 Digital Keypad/Touch Tag Reader BellA Pink BellB Pale Blue WG DO Green WG D1 White Alarm Grey Exit P/B Yellow or In Brown 9 to 28VDC Red Black NO Blue or Bell Alarm D0 D1 12V out Access Control/Alarm COM Purple NC Orange

Programming Instructions for MAW6 Digital Keypad and Card reader FEATURES: Up to 2000 User Codes (4 Digits), touch tags or cards all with a seperate user ID number so they can be removed even if tag or card is lost or code is forgotten. te: need to keep a log book Can use Code or Tag/Card or Code Tag/Card for extra security Activation time from 0 to 99 seconds. Users can change their own Code or Card without Master Code Keypads give a visual as well as acoustic signaling while entering codes PROGRAMMING: To Add a User Code or Tag/Card by ID To Add many Tags/ Cards To Remove a User Code or Tag/Card by ID press 1 press 1 press 2 Enter <User ID Number># 1 to 2000 Swipe Tag/Card Enter <User ID Number># 1 to 2000 will beep beep beep if this user already has a code or card sec if Tag/Card OK or beep beep Enter <User Code># (4 digits) or Swipe Tag/Card Add more? remove more? sec if Code or Card OK or beep beep programming mode programming mode Add more? programming mode www.grantsautomation.com.au grant@grantsautomation.com.au

PROGRAMMING: To Remove a Tag/Card with Tag/Card press 2 Swipe Tag/Card Set Tag/Card only Option press 30 # programming mode Set Tag/Card OR Code Option (default) press 32 # programming mode remove more? programming mode To Remove all User Codes or Tags/Cards Set Tag/Card & Code Option press 31 # programming mode To Change Activation Time press 4 Enter time in seconds from 0 to 99 YELLOW LED goes GREEN for 1/2 sec if OK or beep beep beep if not OK press 20,000 # programming mode programming mode www.grantsautomation.com.au grant@grantsautomation.com.au

Programming Instructions for MAW6 Digital Keypad To Change a User Code To Change the Master Code Restoring Settings. Enter <User ID Number># Enter <old User Code> # Enter <new User Code># (4 digits) Enter <new User Code># (4 digits) to confirm YELLOW LED goes GREEN for 1/2 sec if OK or beep beep beep if not OK press 0 Enter <new Master Code># (6 to 8 digits) Enter <new Master Code># (6 to 8 digits) to confirm YELLOW LED goes GREEN for 1/2 sec if OK or beep beep beep if not OK The factory settings can be recovered it necessary without loosing any user codes, tags or cards programmed in. To do this remove power from the device, then after 15 seconds press and hold the # key and restore power. When the decive beeps left go of the # key as the factory settings have been restored. programming mode programming Record Master Code Here: mode Record User ID numbers and Codes Here: User Name and/or Description User ID Number User Code www.grantsautomation.com.au grant@grantsautomation.com.au