General information. Display. Control elements. Supply voltage

Similar documents
General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

Product type designation

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Configuration control. Display. Control elements. Supply voltage

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage. Input current. Power losses

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Supply voltage

Product type designation. General information. Supply voltage

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

CPU 412H. Function. Parameterizable properties

Product type designation. General information. Supply voltage. Input current

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIPLUS CPU 313C-2DP. Function

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

CPU 412. Function. Programmable properties

Data sheet CPU 015PN (015-CEFPR01)

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. Supply voltage

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Preface. Documentation guide. Product overview.

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

Data sheet CPU 015PN (015-CEFPR00)

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Data sheet CPU 315SN/PN ECO (315-4PN33)

General information. Display. Supply voltage. Input current

Data sheet VIPA CPU M13C (M13-CCF0000)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet CPU 013C (013-CCF0R00)

Data sheet SLIO CPU 015PN (015-CEFPR01)

SIMATIC S Central processing units

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Data sheet CPU 315SN/NET (315-4NE12)

General information. Display. Supply voltage. Input current

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet VIPA CPU 214PG (214-2BE03)

CPU PN (6ES7511-1AK00-0AB0) SIMATIC S CPU PN (6ES7511-1AK00-0AB0) Preface. Documentation guide. Product overview.

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet CPU 315SB/DPM (315-2AG12)

General information. Supply voltage

Data sheet CPU 315SB/DPM (315-2AG12)

CPU PN/DP (6ES7517-3AP00-0AB0) SIMATIC S CPU PN/DP (6ES7517-3AP00-0AB0) Preface. Documentation guide. Product overview.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet VIPA CPU 115DP (115-6BL22)

CP ADVANCED. Function

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

SIMATIC PC-based controller

Data sheet CPU 115 (115-6BL02)

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Multi Panel options. SIMATIC WinAC MP 2/169

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

CPU 1214C. Overview. Design. The compact CPU 1214C has:

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Supply voltage. Input current. Encoder supply. Memory

System description SLIO

Main Catalog 2012/2013 for specialists in automation and control technology

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

Transcription:

Data sheet SIMATIC S7-1500F, CPU 1516F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1,5 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE: PROFIBUS, 10 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY General information Product type designation CPU 1516F-3 PN/DP HW functional status FS01 Firmware version V1.8 Engineering with STEP 7 TIA Portal configurable/integrated as of V13 SP1 Update 4 version Display Screen diagonal (cm) 6.1 cm Control elements Number of keys 6 Mode selector switch 1 Supply voltage Type of supply voltage permissible range, lower limit (DC) permissible range, upper limit (DC) Reverse polarity protection Mains buffering 24 V DC 19.2 V 28.8 V Page 1/10 19.11.2015 Copyright Siemens AG

Mains/voltage failure stored energy time Input current Current consumption (rated value) Inrush current, max. I²t Power Power consumption from the backplane bus (balanced) Infeed power to the backplane bus Power loss Power loss, typ. Memory SIMATIC Memory Card required Work memory integrated (for program) integrated (for data) Load memory Plug-in (SIMATIC Memory Card), max. Backup maintenance-free CPU processing times for bit operations, typ. for word operations, typ. for fixed point arithmetic, typ. for floating point arithmetic, typ. 5 ms 0.85 A 2.4 A; Rated value 0.02 A² s 6.7 W 12 W 7 W 1.5 Mbyte 5 Mbyte 32 Gbyte 10 ns 12 ns 16 ns 64 ns CPU-blocks Number of elements (total) 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements DB Number range 1... 60 999; subdivided into: number range that can be used by the user: 1... 59 999, and number range of DBs created via SFC 86: 60 000... 60 999 Size, max. 5 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB FB Number range 0... 65 535 Size, max. 512 kbyte FC Number range 0... 65 535 Size, max. 512 kbyte OB Page 2/10 19.11.2015 Copyright Siemens AG

Size, max. 512 kbyte Number of free cycle OBs 100 Number of time alarm OBs 20 Number of delay alarm OBs 20 Number of cyclic interrupt OBs 20 Number of process alarm OBs 50 Number of DPV1 alarm OBs 3 Number of isochronous mode OBs 2 Number of technology synchronous alarm OBs 2 Number of startup OBs 100 Number of asynchronous error OBs 4 Number of synchronous error OBs 2 Number of diagnostic alarm OBs 1 Nesting depth per priority class 24; Up to 8 possible for F-blocks Counters, timers and their retentivity S7 counter Number 2 048 Retentivity adjustable IEC counter Number Any (only limited by the main memory) Retentivity can be set S7 times Number 2 048 Retentivity adjustable IEC timer Number Any (only limited by the main memory) Retentivity adjustable Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Number of clock memories Data blocks Retentivity adjustable Retentivity preset 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB 16 kbyte 8; 8 clock memory bits, grouped into one clock memory byte No Page 3/10 19.11.2015 Copyright Siemens AG

Local data per priority class, max. 64 kbyte; max. 16 KB per block Address area Number of IO modules 8 192; max. number of modules / submodules I/O address area Inputs 32 kbyte; All inputs are in the process image Outputs 32 kbyte; All outputs are in the process image per integrated IO subsystem Inputs (volume) 8 kbyte Outputs (volume) 8 kbyte per CM/CP Inputs (volume) 8 kbyte Outputs (volume) 8 kbyte Subprocess images Number of subprocess images, max. 32 Hardware configuration Number of hierarchical IO systems 20 Number of DP masters integrated 1 Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total Number of IO Controllers integrated 1 Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total Rack Modules per rack, max. 32; CPU + 31 modules Rack, number of rows, max. 1 PtP CM Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots Time of day Clock Type Hardware clock Backup time 6 wk; At 40 C ambient temperature, typically Deviation per day, max. 10 s; Typ.: 2 s Operating hours counter Number 16 Clock synchronization supported to DP, master Page 4/10 19.11.2015 Copyright Siemens AG

in AS, master in AS, slave on Ethernet via NTP Interfaces Number of PROFINET interfaces 2 Number of PROFIBUS interfaces 1 1. Interface Interface types Number of ports 2 integrated switch RJ 45 (Ethernet) ; X1 Protocols PROFINET IO Controller PROFINET IO Device SIMATIC communication Open IE communication Web server Media redundancy 2. Interface Interface types Number of ports 1 integrated switch No RJ 45 (Ethernet) ; X2 Protocols PROFINET IO Controller No PROFINET IO Device No SIMATIC communication Open IE communication Web server 3. Interface Interface types Number of ports 1 RS 485 Protocols SIMATIC communication PROFIBUS DP master PROFIBUS DP slave No Interface types RJ 45 (Ethernet) 100 Mbps Autonegotiation Page 5/10 19.11.2015 Copyright Siemens AG

Autocrossing Industrial Ethernet status LED RS 485 Transmission rate, max. 12 Mbit/s Protocols Number of connections Number of connections, max. 256; via integrated interfaces of the CPU and connected CPs / CMs Number of connections reserved for ES/HMI/web Number of connections via integrated interfaces Number of S7 routing paths 16 PROFINET IO Controller Services 10 128 PG/OP communication S7 routing Isochronous mode Open IE communication IRT MRP ; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50 PROFIenergy Prioritized startup ; Max. 32 PROFINET devices Number of connectable IO Devices, max. 256; In total, up to 768 distributed I/O devices can be connected via PROFIBUS or PROFINET Of which IO devices with IRT, max. 64 Number of connectable IO Devices for RT, max. 256 of which in line, max. 256 Number of IO Devices that can be simultaneously activated/deactivated, max. Number of IO Devices per tool, max. 8 8 Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO with RT for send cycle of 250 µs 250 µs to 128 ms for send cycle of 500 µs 500 µs to 256 ms for send cycle of 1 ms 1 ms to 512 ms for send cycle of 2 ms 2 ms to 512 ms for send cycle of 4 ms 4 ms to 512 ms With IRT devices, and on the quantity of configured user data Page 6/10 19.11.2015 Copyright Siemens AG

for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive for send cycle of 500 µs 500 µs to 8 ms for send cycle of 1 ms 1 ms to 16 ms for send cycle of 2 ms 2 ms to 32 ms for send cycle of 4 ms 4 ms to 64 ms With IRT and parameterization of "odd" send cycles PROFINET IO Device Services PG/OP communication S7 routing Isochronous mode No Open IE communication IRT MRP PROFIenergy Shared device Number of IO Controllers with shared device, max. SIMATIC communication S7 communication, as server S7 communication, as client User data per job, max. Open IE communication TCP/IP Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs... 3 875 µs) 4 See online help (S7 communication, user data size) Data length, max. 64 kbyte several passive connections per port, supported ISO-on-TCP (RFC1006) UDP Data length, max. 64 kbyte Data length, max. 1 472 byte DHCP SNMP DCP LLDP Web server HTTP HTTPS PROFIBUS DP master No ; Standard and user-defined pages ; Standard and user-defined pages Page 7/10 19.11.2015 Copyright Siemens AG

Number of connections, max. 48; for the integrated PROFIBUS DP interface Services PG/OP communication S7 routing Data record routing Isochronous mode Equidistance Number of DP slaves 125; In total, up to 768 distributed I/O devices can be connected via PROFIBUS or PROFINET Activation/deactivation of DP slaves Further protocols MODBUS Media redundancy Switchover time on line break, typ. Number of stations in the ring, max. 50 ; MODBUS TCP 200 ms Isochronous mode Isochronous operation (application synchronized up to terminal) Equidistance ; With minimum OB 6x cycle of 375 µs S7 message functions Number of login stations for message functions, max. 32 Block related messages Number of configurable alarms, max. 10 000 Number of simultaneously active alarms in alarm pool Number of reserved user alarms 600 Number of reserved alarms for system 200 diagnostics Number of reserved alarms for motion 160 technology objects Test commissioning functions Joint commission (Team Engineering) ; Parallel online access possible for up to 8 engineering systems Status block ; Up to 8 simultaneously (in total across all ES clients) Single step No Status/control Status/control variable Variables Inputs, outputs, memory bits, DB, times, counters Number of variables, max. of which status variables, max. 200; per job of which control variables, max. 200; per job Forcing Page 8/10 19.11.2015 Copyright Siemens AG

Forcing, variables Peripheral inputs/outputs Number of variables, max. 200 Diagnostic buffer present Number of entries, max. 3 200 of which powerfail-proof 500 Traces Number of configurable Traces 4; Up to 512 KB of data per trace are possible Interrupts/diagnostics/status information Diagnostics indication LED RUN/STOP LED ERROR LED MAINT LED Connection display LINK TX/RX Supported technology objects Motion Speed-controlled axis Number of speed-controlled axes, max. 30; Requirement: There must be no other motion technology objects created Positioning axis Number of positioning axes, max. 30; Requirement: There must be no other motion technology objects created Synchronized axes (relative gear synchronization) Number of axes, max. 15; Requirement: There must be no other motion technology objects created External encoders Controller Number of external encoders, max. 30; Requirement: There must be no other motion technology objects created PID_Compact PID_3Step PID-Temp Counting and measuring High-speed counter Ambient conditions Ambient temperature during operation ; Universal PID controller with integrated optimization ; PID controller with integrated optimization for valves ; PID controller with integrated optimization for temperature horizontal installation, min. 0 C horizontal installation, max. 60 C; Display: 50 C, at an operating temperature of typically 50 C, the display is switched off vertical installation, min. 0 C Page 9/10 19.11.2015 Copyright Siemens AG

vertical installation, max. 40 C; Display: 40 C, at an operating temperature of typically 40 C, the display is switched off Configuration Programming Programming language LAD ; incl. failsafe FBD ; incl. failsafe STL SCL GRAPH Know-how protection User program protection Copy protection Block protection Access protection Password for display Protection level: Write protection Protection level: Read/write protection Protection level: Complete protection Cycle time monitoring lower limit upper limit adjustable minimum cycle time adjustable maximum cycle time Dimensions Width Height Depth Weights Weight, approx. 70 mm 147 mm 129 mm 845 g last modified: 12.11.2015 Page 10/10 19.11.2015 Copyright Siemens AG