Connect to the Future Today with Allen-Bradley s SLC 5/05 Processor with Ethernet SLC 5/05 Programmable Controllers (Cat. Nos. 1747-L551, -L552, -L553) Product Profile Allen-Bradley s SLC 5/05 Programmable Controllers (1747-L551, 1747-L552, and 1747-L553) provide high bandwidth networking for standards-based distributed programmable controller systems. They bring 10 Mbps Ethernet connectivity to the popular SLC 500 family of programmable controllers. Allen-Bradley supports TCP/IP (Transmission Control Protocol/Internet Protocol), a communication protocol in wide use over Ethernet networks. We integrate control systems with supervisory monitoring and information management systems through the SLC 5/05 processors that support TCP/IP-over-Ethernet communication. Through Ethernet networks, your SLC 5/05 processors can communicate plant-floor data in data acquisition, supervisory control, program management, statistical quality control, maintenance management, production scheduling, and material tracking applications. We help make it easy for you to use Ethernet networks in applications such as supervisory monitoring and SLC 5/05 processor program management. Processor Overview: Three processor models (16K, 32K and 64K memory) to fit a wide range of applications Built-in 10Base-T Ethernet channel 10 Mbps communications TCP/IP protocol Uses widely available Ethernet devices and cabling Supports online programming over Ethernet with RSLogix 500 Programming Software
Processor Overview: (continued) Supports Simple Network Management Protocol (SNMP) for network management Achieves high-speed peer-to-peer programmable controller communications via the SLC 500 message instruction High-speed performance 0.90 ms/k typical scan time Built-in real-time clock/calendar, Year 2000 and Leap Year ready 1 ms Selectable Timed Interrupt (STI) for use in time critical applications 0.50 ms Discrete Input Interrupt (DII) for use in high-speed applications Advanced math features trigonometric, PID, exponential, floating point, and the compute instruction Indirect addressing Flash PROM enables future firmware upgrades without physically changing EPROMs Programming: RSLogix 500, a Microsoft 32-bit Windows 95 and Windows NT programming software package, supports Allen-Bradley SLC 500 and MicroLogix families of processors. RSLogix 500 is designed to offer powerful functionality, superior diagnostics, reliable communications, and an easy-to-use interface. RSLogix 500 provides everything you expect in a programming software package, from consolidated project view to drag-and-drop editing. Plus RSLogix 500 is part of the RSLogix family of products that share: A common user interface and feature set Flexible, easy-to-use editors Point-and-click I/O configuration Powerful database editor Diagnostic and troubleshooting tools Dependable communications Flexible Ladder Editor Create programs without constantly correcting syntax errors, then later use the Project Verifier to navigate through the corrections. Powerful Database Editor Use the Symbol Group Editor to classify a group of symbols for easy reuse from project to project. Use the Symbol Picker to select address or symbols to address ladder instructions. RSLogix 500 symbols may be 20 characters long. Address comments may reach 100 characters (5 lines x 20 characters). Each rung comment may be 65K characters in length. Export your database to Comma-Separated-Value (CSV) format for use in Excel or another spreadsheet program Import changes back into RSLogix 500. Programming Tools RSLogix 500 designed for Microsoft Windows 95 and NT (4.0 or later) gives you powerful tools, such as drag and drop, multiple window view, drop down menus and much more. Diagnostics & Troubleshooting Tools Use Advanced Diagnostics to navigate to an application area that is causing problems. Use the Custom Data Monitor to monitor the status of bits, timers, counters, inputs, and outputs from within one window. Create a unique Custom Data Monitor window for each application. Upgradeability and Reusability Easily upgrade projects from Rockwell Software DOS programming packages, by opening the existing project in RSLogix 500. Or move a project developed in RSLogix 500 to any of the DOS programming packages.
Features and Benefits Supports standard Ethernet communications on Channel 1. The SLC 5/05 processors support 10Mbps Ethernet communications and use the TCP/IP protocol. The 10Base-T Ethernet channel provides an economical connection to your Ethernet Network. Built-in Ethernet, not an add on module. The SLC 5/05 delivers fast data throughput with no backplane delays. The SLC 5/05 Modular Processors provide a second channel (Channel 0) for RS-232 communication. This allows: Dial up for remote monitoring and programming Networking over modems for SCADA master/slave RTU applications An alternate connection for operator interfaces freeing up peer-to-peer network Direct communication to ASCII devices such as bar code decoders and serial printers via a complete set of ASCII ladder instructions which simplify programming Direct connection to personal computer Channel 0 also supports DH-485 communication. Communication via the DH-485 network is available in every SLC processor we ship, reducing your system cost for processor communication. Supports user memory sizes of 16K, 32K, and 64K. By offering a wide range of user memory, the SLC 5/05 modular processors can be used in a wide range of applications. Supports a variety of input and output modules. The 1746 modular I/O system offers over 60 types of modules, allowing you to customize your control solution to meet your application needs, including discrete, analog, and specialty modules. Supports I/O configurations of up to 3 chassis (30 local I/O slots). Provides you with the flexibility to expand I/O capacity as required. Supports remote I/O and DeviceNet. The SLC 5/05 processors support up to 4096 discrete inputs and 4096 discrete outputs. This I/O can be any mix of local I/O, remote I/O, or I/O on a DeviceNet network. This also allows for connectivity to flex I/O. Provides user-selectable program security. The wide range of system protection capabilities allow you to secure user data and program files from changes. Supports a host of third-party products through the Allen-Bradley Encompass Program. The Encompass Program provides access to products and services that increase your application capabilities.
THIS SIDE UP ALLEN-BRADLEY 1784-PCC COMMUNICATION CARD ALLEN-BRADLEY 1784-PCC COMMUNICATION CARD ALLEN-BRADLEY 1784-PCC COMMUNICATION CARD ALLEN-BRADLEY 1784-PCC COMMUNICATION CARD ALLEN-BRADLEY 1784-PCC COMMUNICATION CARD ALLEN-BRADLEY 1784-PCC COMMUNICATION CARD System Example Windows NT or Windows 95 w/rsview Modem Link to Internet RSLinx and Windows 95 PCMCIA for ControlNet THIS SIDE UP RAC 6000 Industrial Conputer RSLogix 5, RSLinx, RSNetWorx SLC -5/05 W/KFC15 PLC-5C Controller w/enet interface TView PanelView 900,1000 or 1400e SLC -5/05 DeviceNet Scanner PLC-5C Controller SLC 500 I/O FLEX I/O 1336 FORCE Drive DeviceNet Scanner Dodge Smart Bearing Reliance Smart Motor SMP-3 Solid-State Overload AdaptaScan Bar Code Reader MicroLogix Controller Photoelectric Sensor
SLC 5/05 Processor General Specifications Specification 1747-L551 1747-L552 1747-L553 Memory Size 16K Words 32K Words 64K Words I/O Capacity up to 4096 inputs and 4096 outputs Maximum Chassis/Slots 3/30 Standard RAM Lithium Battery (2 years) Memory Back-up Options Flash EPROM LED Indicators Run, CPU Fault, Battery Low, Forced I/O, Ethernet, RS-232 Typical Scan Time 1 0.9 ms/k Bit Execution (XIC) 0.37 µs Communication Channel 1: Ethernet (10Base-T) Channel 0: RS-232 (DF1, ASCII, or DH485) Power Supply Loading at 1A 5V dc Power Supply Loading at 200 ma 24V dc Clock/Calendar Accuracy ±54 sec/month at +25 C (+77 F), ±81 sec/month at +60 C (+140 F) Year 2000 and Leap Year Ready Program Scan Hold-up Time 20 milliseconds to 3 seconds (dependent on power supply loading) after Loss of Power Noise Immunity NEMA Standard ICS 2-230 Ambient Temperature Rating Operating: 0 C to +60 C (+32 F to +140 F) Storage: -40 C to +85 C (-40 F to +185 F) Humidity 5 to 95% without condensation Shock (operating) 30Gs Vibration Displacement:.015 in., peak-to-peak at 5 to 57 Hz Acceleration: 2.5Gs at 57 to 2000 Hz Certification UL listed/csa approved Class 1, Groups A, B, C or D, Division 2 CE compliant for all applicable directives Ethernet Connections 16 simultaneous open connections per Processor Primary Cable Connection RJ45 Node Address Type Internet Protocol (IP address) Data Rate 10 Mbps 1 The scan times are typical for 1K ladder logic program consisting of simple ladder logic and communication servicing. Actual scan times depend on your program size, instructions used, and communication protocol.
SLC 5/05 System Test Specifications Description Specification Temperature Operating: 0 C to +60 C (+32 F to +140 F) Storage: -40 C to +85 C (-40 F to +185 F) Humidity 5 to 95% without condensation Vibration Operating: 1.0G at 5 to 2000 Hz Non-operating: 2.5Gs at 5 to 2000 Hz Shock Operating: 30.0Gs (3 pulses, 11 ms) Non-operating: 50.0Gs (3 pulses, 11 ms) Free Fall (drop test) Portable, 2.268 kg (5 lbs) or less at 0.762m (30 in.) (six drops) Portable, 2.268 kg (5 lbs) or more at 0.1016m (4 in.) (three flat drops) Electromagnetic Compatibility Showering Arc: 1.5 KV Per NEMA ICS 2-230/NEMA ICS 3-304 Surge Withstand Capability: 3 KV Per IEEE Std. 472-1974/ANSI C37.90/90A-1974 Fast Transient Burst (impulse): 2 KV for 1746 power supplies, 1 KV for 1746 I/O and communication lines over 10m (32.84 ft), 5 ns rise time Electrostatic Discharge (ESD): 15 KV, 100 pf/1.5k ohm model Radiated Electromagnetic Susceptibility: 5W walkie-talkie at 464.5 MHz and 153.05 MHz Safety Dielectric Withstand: 1500V ac Per UL 508, CSA C22.2 No. 142 Isolation between Communication Circuits: 500V dc Isolation between Backplane and I/Os:1500V ac Flammability and Electrical Ignition: UL94V-0 Certification UL listed/csa approved Class 1, Groups A, B, C or D, Division 2 CE compliant for all applicable directives For more information about the SLC 5/05 processor with built-in Ethernet, as well as other products and services, contact your local Allen-Bradley sales representative, authorized distributor or authorized system integrator. SLC 500, Encompass, ControlLogix, RAC6000, and MicroLogix are trademarks of Rockwell Automation. Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation. Microsoft and Windows 95 are registered trademarks of Microsoft Corporation. Windows NT is a trademark of Microsoft Corporation. DeviceNet is a trademark of Open DeviceNet Vendor Association. RSLogix 500 is a trademark of Rockwell Software, Inc. Publication 1747-1.18 November 1997 Copyright 1997 Rockwell International Corporation. All rights reserved. Printed in USA