The Rosemount 356 Nuclear Connector

Similar documents
Rosemount 0085 Pipe Clamp Sensor

AMPMODU* MOD I Interconnection System

HIGH POWER CONTACT ELECTRICAL SPECIFICATIONS

Rosemount 1595 Conditioning Orifice Plate

Nuclear Power Generation Range 8N45 SERIES. Reactor Containment Certified Connectors

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet December 2014 IP207, Rev DA

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

EPIC Circular Connectors CIRCON M23 Series

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB

Rosemount 1595 Conditioning Orifice Plate

Rosemount 2110 Compact Vibrating Fork Liquid Level Switch

EPIC LS1 Series Circular Power & Mixed Power Connectors

EN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc

Rosemount 1595 Conditioning Orifice Plate

3420 Fieldbus Interface Module (FIM) Contents

Smart Wireless THUM Adapter

Safety switches for hinged doors

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET


Bulletin 871D Cylinder Position Inductive Style

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Safety switches with separate actuator

Smart Wireless THUM Adapter

PERFORMANCE SPECIFICATION SHEET CONNECTORS, COAXIAL, RADIO FREQUENCY, SERIES C (UNCABLED-RECEPTACLE, FEMALE, JAM NUT MOUNTED, HERMETIC SEAL, CLASS 2)

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

Instruction Sheet Board Style Low Water Cutoff

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Applications & Features, Type SSMP When using blind mate connectors in an application, careful consideration has to be given to choosing the right con

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

Figure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.

MMT330 Series Moisture and Temperature Transmitters for Oil

ASCO 920 Remote Control (RC) Switches

Safety switches with separate actuator

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Conveyor Belt Alignment Switches from IDEM

Smart Wireless THUM Adapter

versatile connectors for any application

masterelectronics.com onlinecomponents.com

Applications

Installation Instructions Temperature transmitter TAA /00 06/2011

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

DETAIL SPECIFICATION SHEET

Product Performance Specification Mini Power Connector

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

DETAIL SPECIFICATION SHEET

07. har-link INTERFACE CONNECTORS

Terminals, Lugs, and Fasteners

Limit Switches E47 Precision Switches

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Smiths Connectors Sabritec Test Report High Speed and Durability Test Quadrax Pin Contact & SKT Contacts

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Safety switches with separate actuator

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

iprox Sensing Solutions iprox Analog iprox Standard iprox Clone iprox Accessories iprox. The world s most versatile proximity sensor.

IP68 Sealed - Mini USB Buccaneer

PROXIMITY SENSORS. This document provided by Barr-Thorp Electric Co., Inc

802B Compact, Precision and Small Precision

4110 HART Level Encoder

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

0.703 dia. [17.86] Cord Connector Contact Arrangements Shown from rear of connector DIMENSIONS ARE FOR REFERENCE ONLY


Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

v1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc.

Solenoid Valves PN16 for gas flow interception

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, COAXIAL, RADIO FREQUENCY, (SERIES N (CABLED), PIN CONTACT, CLASS 2)

Data sheet C6 A modul 90 jack

Flowtronic D 607 Series

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

07. har-link Interface Connectors

Mar11 Rev C

Safety switches with manual mechanical delay and separate actuator

A2, LP2 & CB2. Single Row Terminal Blocks. Dimensions Inches (Millimeters) Specifications A2 & LP2 CB2

Level-Lance Model 5400A

PERFORMANCE SPECIFICATION ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY, (BETWEEN SERIES SMA TO SERIES TNC), CLASS 2, STRAIGHT PLUG

PRODUCT SPECIFICATION. This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors.

JAN 16 Rev B

920 Remote Control (RC) Switches

Telephony Multi-Taps. 9000T-TP Series

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

HART Communicator. Emerson Process Management Catalog

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS

Audio Patching Systems ProPatch Programmable (PPP) Series

M23 Connectors and cables

PD Channel Digital IO PD Series 600

Tongue Switches Trojan 5 & 6

FEATURES DESCRIPTION

Sales: Technical: Fax:

Transcription:

Product Data Sheet 00813-0200-4856, Rev AE March 2013 Rosemount 356 The Rosemount 356 Nuclear Connector Easy-to-install connector for use outside containment Die cast zinc or stainless steel connector body Available with top or side entry hood Qualified with Rosemount Nuclear Instruments pressure transmitters for mild service Contents Product Description... page 2 Qualification Standards & Reports... page 2 Nuclear Specifications... page 2 Functional Specifications... page 2 Physical Specifications... page 2 Installation... page 3 Field Side Kits... page 3 Revision Control... page 3 Dimensional Drawings... page 3 Ordering Information... page 5

Rosemount 356 Product Data Sheet March 2013 PRODUCT DESCRIPTION The Rosemount 356 Nuclear Electrical Connector is a clamp-style disconnect device. The connector is sealed on the instrument side to prevent moisture and water from penetrating the conduit entry. The 356 connector is available with a top or side entry hood on the field side. The connector assembly is manufactured under a nuclear quality assurance program that meets the requirements of KTA 1401 / 3507 and IAEA 50-C-Q. The instrument-side connector can be ordered with or without unassembled field side kit (for installation on-site with customer-provided cable, using approved assembly instructions). Figure 1. Rosemount 356 Nuclear Connector. Intended Applications 1E outside containment (valve chamber, annulus & auxiliaries) Features and Benefits Easy-to-install connector for use outside containment Choice of conduit entry threads (male): M20x1.5, PG13.5 Available with top or side entry hood Available in zinc die-cast or stainless steel connector body Qualified with Rosemount Nuclear Instruments pressure transmitters for mild service, no LOCA Maintenance free Qualification Standards & Reports KTA 3505 (11/2005), IEEE Std 344, IEC 61000, IEC/CISPR 16: D2009011, KTA Qualification Report for Rosemount 3152K Pressure Transmitter D2009013, KTA Qualification Report: Rosemount 356 Nuclear Connector SPECIFICATIONS Nuclear Specifications Qualification of Rosemount 356 has been established in conjunction with KTA testing of Rosemount 3152K pressure transmitter. See 3152K Product Data Sheet (00813-0200-4852) for nuclear specifications; qualification testing of 3152K with 356 Nuclear Connector (zinc die cast) is documented in qualification report D2009011. Rosemount 356 is not qualified for LOCA. Functional Specifications (1) Dielectric 60 sec @ 500 VAC: Withstand leakage 30 micro Amp Insulation 10 sec @ 500 VDC: Resistance IR 1 GOhm (1) Verified 100% during connector manufacturing Electrical Specifications (2) Working Voltage 250 V Working Current 1 Amp @ 125 C Contact Resistance 3 mohm (2) Maximum rated values Physical Specifications Weight (Instrument side) Protection Level (coupled) Approval according to UL 50 (coupled) 0.085 kg (zinc) 0.117 kg (SST) IP 65 NEMA 4X Materials of Construction Body Crimp Terminal Profile Seal (O-ring) Potting (instrument side) Lead Wire (instrument side) Installation Zinc die cast or, 316L SST Ryton FPM Stycast Eupen insulated wire (0.5 mm 2 ) 2

Product Data Sheet March 2013 Rosemount 356 The Rosemount 356 should be installed into the conduit entry using a plant-approved sealant with locknut tightened to 25 N-m (221 in-lb) (see instrument product manual for details). Integral lead wires are then connected to the instrument s terminal block, with polarity according to end user s requirements. The field-side is coupled to the instrument-side with a snap-type connection. If the 356 connector is not factory-installed, qualification of the instrument/connector interface becomes the user s responsibility. Field Side Kits Field side kits are available for on-site assembly using customer-provided instrumentation cable. Crimp tool is required for proper assembly and is available from Rosemount. The customer is responsible for proper assembly and for using an instrumentation cable that is both qualified and compatible with connector components. Contact Rosemount Nuclear Instruments for technical assistance. Revision Control Reference File RF-0356-EPR-01 has been created to document the evolution of important drawings, part numbers, manufacturing, test, and inspection procedures associated with the Rosemount 356 Nuclear Connector. The Reference File is maintained in accordance with RNII s documented quality system, and is intended to satisfy the requirements of Reference File as defined by RCC-E and Document Catalogue as defined by KTA. Baseline qualification hardware is documented in Equipment Identification File EIF-0356-EPR-01. Transmitter boundary 45 (1.77) Figure 2a. Instrument side connector Zinc die cast. Transmitter boundary 40 (1.57) 47 (1.85) Figure 2b. Instrument side connector SST. Figure 3. Wiring scheme. (see ordering information for polarity codes) Note: Dimensions are nominal in millimeters (inches). 3

Rosemount 356 Product Data Sheet March 2013 120 (4.72) 28 (1.10) Figure 4a. Coupled connector top entry hood (Zinc die cast). 95 (3.74) 60 (2.36) Figure 4b. Coupled connector side entry hood (Zinc die cast). 122 (4.80) 40 (1.57) Figure 5a. Coupled connector top entry hood (SST). 97 (3.82) 60 (2.36) Figure 5b. Coupled connector side entry hood (SST). Note: Dimensions are nominal in millimeters (inches). 4

Product Data Sheet March 2013 Rosemount 356 B/E A/D MODEL ORDERING INFORMATION Rosemount 356 Nuclear Electrical Connector (Type Han 7D) Model Description 356 Rosemount Nuclear Electrical Connector Connector Configuration (see note 2) A Instrument-side Only (zinc die cast) B Instrument-side + Field-side Kit (unassembled; no cable) (zinc die cast) D Instrument-side Only (SST) E Instrument-side + Field-side Kit (unassembled; no cable) (SST) Assemble to Flag & Polarity (see note 3) 0 Connector only; not ordered with pressure transmitter 1 Connector assembled to transmitter, pin 1 = positive 2 Connector assembled to transmitter, pin 2 = positive Conduit Entry Threads T2 PG13.5 T3 M20x1.5 Wire Size (Instrument side) 20 20 AWG (0.5mm 2 ) Number of Pins (see note 4) P2 2 Pins P3 3 Pins P4 4 Pins Lead Wire Length (Instrument side) 0150 150 mm (direct mounting of connector) 0200 200 mm (connector installed with 90 conduit elbow) xxxx Customer-specified Length (mm) Connector Hood Type (Field side) H1 Top Entry Hood H2 Side Entry Hood Wire Size (Field side) must agree with cable type W20 20 AWG (0.5mm 2 ) W18 18 AWG (1.0mm 2 ) Cable Gland (Field side) (see note 1) G1 Perfect EMC Notes (1) KTA qualification testing was performed using 356 Nuclear Connectors (zinc die cast) fabricated with Wadi EMC cable glands and Eupen cable, which were then installed on Rosemount 3152 & 1152 Pressure Transmitters. Perfect EMC cable gland is qualified to same levels by similarity. SST connectors are qualified by similarity analysis and test. Analysis or test may be required to demonstrate performance of other cable glands or cables. (2) The end user must take care to assemble field side kits in accordance with approved instructions. The end user is responsible for on-site assembly of field side connectors. (3) Explanation of assemble to flag and polarity: - code 0 should be used when ordering spare connectors for on-site installation by end user. - code 1 : Instrument side connector is factory-installed with pin 1 to positive terminal (see Figure 3). - code 2 : Instrument side connector is factory-installed with pin 2 to positive terminal (see Figure 3). (4) If ordering option code P4, contact Rosemount Nuclear Instruments, Inc. for wiring information. 5

Rosemount 356 Product Data Sheet March 2013 The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, and the Rosemount logotype are registered trademarks of Rosemount, Inc. All other marks are the property of their respective owners. Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale Emerson Process Management Rosemount Nuclear Instruments, Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (952) 949-5210 2013 Rosemount Inc. All rights reserved. www.rosemountnuclear.com