Mt. Stony Brook Meade 14-inch Set Up and Operations Manual

Similar documents
Mt. Stony Brook Meade 14-inch Set Up and Operations Manual

ESPRIT 120 ED Super APO

Orion StarShoot P1 Polar Alignment Camera

Quick Start Guide. SkyGuide Pro Camera Mount Model: #3550

xr Fiber Platform User Guide

Room Classroom Technology Updated March 4, 2019

IRF90 - Rotating Focuser

You, too, can make useful and beautiful astronomical images at Mees: Lesson 2

TEC APO 200 OWNER S MANUAL

Macro View All in One Scope Description. 2. Features. 3. Package Contents

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

First-Time Setup. Summary Steps CHAPTER

Quick Set-up Guide for the Biomedx Configured Olympus CX43

M40 Microscope User s Manual

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

Kodak Retina II (type 122)

Using an Astrodon MonsterMOAG with a Takahashi FSQ-106N Frank Barnes III December 15, 2007

2MASS Observer s Guide. Steward Observatory 61 Kuiper Telescope

ED80Sf ED100Sf Vixen Optics a Division of MrStarGuy, Inc.

Room Classroom Technology Updated March 4, 2019

SECURITY MASTERS ADVANCED MODULE 2

Room Classroom Technology Updated August 29, 2018

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

Mi50 Inverted Microscope User s Manual. Fein.

HPP Observatory Quick User Guide

Turn any wall projection interactive with Integrated Arm

Product Overview. Features

ASTRO-PHYSICS GTO CONTROL BOX FOR SERVO DRIVE Model GTOCP1

Quick Start Guide. Basic set-up for your Axis360 system

kena Instruction Manual T-1050

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

Operating Procedure for Horiba Raman Microscope

Silicon Chip Cleaving Tool

CoSMoS Starter Guide 1.4 Hoskins Lab Last Modified 03/03/2017 Chris DeCiantis

Microscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0

Eye-Pal Vision Quick Start Rev. A

Delta Five Bed Bug Monitoring System

Gemini 2 Quick Start Guide

Virtual Desktop Infrastructure Setup for MacOS

Written By: Walter Galan

Step 1: Adding Darwin to your computer

Smart Classroom Quick Start Guide. La Tourette 200. Orientation. Projector. Screen Control on East Wall by double doors. Document Camera.

Sylphit-Duo DSK-Series. KVM Drawer (with integrated KVM switch)

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

DV2. Alignment Procedure. Install DV2 on Microscope NOTE: PLEASE READ THE ENTIRE PROCEDURE BEFORE YOU BEGIN ALIGNMENT OF THE DV2. Alignment Procedure

EV3 Programming Workshop for FLL Coaches

Instruction Manual For. StarSplitter. & StarSplitter Video Astronomy Solution. We Bring the Universe Down to Earth

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

CoSMoS Starter Guide 1.6 Hoskins Lab Last Modified 03/30/2017 Chris DeCiantis

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

imac Intel 21.5" EMC 2389 Stand Replacement

Screen. Projector. Document Camera. Computer Monitor. Smart Classroom Quick Start Guide Music 173. Orientation

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

INSTRUCTION MANUAL POLARIZING & ORE MICROSCOPES. Polarizing Microscopes. Ore Microscopes. Model: NYMC62B00

GPS Asset Tracker - 3 Month Battery. User s Guide

Lynx Instruction Manual

kena TM Instruction Manual T-1050

Table of Contents Introduction... 4

Astronomy 150 Asteroid Lab Due in Class: Monday, Oct. 26

Primary Use. Operating Principle

1.0-m Telescope Control Software

Des Adapter CR-DA1. Operation Manual

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

ACE Desktop: Dome, Telescope, Instruments

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

25 Sport Scope Instruction Manual

Paramount Electronics Replacement Instructions

External filter wheels for G2, G3 and G4 CCD cameras

INTRODUCTION...1 FEATURES...1 PACKAGE CONTENTS... 1 TECHNICAL SPECIFICATIONS...2 SYSTEM REQUIREMENT..3 CABLE DIAGRAMS.3 PRODUCT DETAILS 4

Meade LS6 & LS8 LightSwitch Primer

PH 481/581 Physical Optics Winter 2018

For documentation, both instruments are available with a trinocular head which permits mounting of a video or digital camera system.

Dell Inspiron XPS and Inspiron 9100 Service Manual

Instruction Manual. Omegon Push+ Mini mount Art. Nr

M20 Metallurgical Microscope User s Manual. Fein.

Artemis Focuser User Guide. S Chambers

The Nureva Span ideation system. Installation guide. Single panoramic system

Virtual Desktop Infrastructure Setup for MacOS

LumaRail Free Stand Bed Assist Rail with IntelliBrite LED Night Light

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Panalytical MRD X-Ray Diffraction SOP

444/544 Advanced Lab Manual Astronomy

KM-4800w. Installation Guide

Installing the Focus Motor

7th Grade Basic Computer Training

SAMi Installation Instructions

Inspection Camera. User Manual

Projector. Screen. Computer Monitor. Document Camera Smart Classroom Quick Start Guide Still Gym 302. Orientation

Sony NEX-7 Screen Replacement

Further Information can be found at

Installing the Focus Motor

Smart Classroom Quick Start Guide

Projector. Screen Computer Monitor. Document Camera. Smart Classroom Quick Start Guide. Psych/CompSci 156. Orientation

Camera Installation Manual Ver 1.0. Pan, Tilt and Zoom Dome Camera / PTZ

Index Step 1 Setting up your surveillance system Step 2 Recording and accessing video on your DVR Step 3 Accessing your DVR from a Local Computer PC

Orion Deluxe Off-Axis Guider

Room Classroom Technology Updated March 4, 2019

Easy Installation Guide

Basic Computer and Mouse Skills Windows 10

Transcription:

Mt. Stony Brook Meade 14-inch Set Up and Operations Manual Anja von der Linden Original version by Matthew J. Wahl and Stanimir Metchev: Mar 1, 2010 Updated: August 24, 2016 This document includes instructions on how to set up and operate the Meade 14-inch telescope atop Mt. Stony Brook. 1. Checklist Make sure that you have all of the equipment you need to perform observations (e.g., eyepieces). Meade s telescope manual Eyepieces (if conducting eyepiece observations) If conducting CCD observations, then also: CCD camera briefcase laptop running the CCDOps or CCDSoft software power supply for laptop 2. Start-Up Procedure 1. DO NOT OPEN THE DOME IF IT IS RAINING, SNOWING, OR IF THERE ARE STRONG WINDS. 2. Open both doors, use rope to keep them open in order to cool down the dome. 3. Switch on the power to the dome drives: big ON / OFF handle on northern inside wall of the dome. 4. Use the dome remote to open the top shutter: press start, then open top shutter. 5. Use the dome remote to open the lower shutter: press start, then open lower shutter.

2 6. Remove the dust cover from the telescope. 7. After the top shutter has opened completely, remove the cap from the front of the telescope, as well as caps from the finder scope, eyepiece holder etc. 8. Plug in the telescope: the telescope power cable is wrapped around the telescope pillar. 9. R.A. and DEC. locks on the telescope tube must be and MUST REMAIN in the LOCKED position. 10. For eyepiece viewing: round counterweight underneath the telescope tube must be OFF. 11. For eyepiece viewing: put on your eyepiece of choice; tighten the two screws that secure it to the telescope. 12. For CCD observing: put on the largest counterweight underneath the telescope tube. The counterweight slide along the railing underneath the tube. First unscrew the screw at the end of the railing that is near the front end of the telescope. Then slide the counterweight until it reaches the Scotch tape mark on the railing. Tighten the screws on the counterweight. Replace the screw at the end of the railing. 13. For CCD observing: assemble the mount for the CCD camera. Remove the CCD camera from its box, gently unscrew its cover, screw on the cylindric attachment that is used to mount it to the telescope. The attachment, the four necessary screws (in a small ziplock bag), and a set of Allen wrenches should all be in the CCD briefcase. 14. For CCD observing: put on the CCD camera instead of an eyepiece. Take off the 90 reflecting element. Slide in and rotate the CCD camera so that its body is pointing to the left when viewed from behind the telescope. This is done for balancing purposes. FIRMLY tighten the two screws that secure the CCD camera to the telescope. Be sure to put the dust cover onto the end of the 90 reflecting element. 15. For CCD observing: plug in the CCD into the telescope pillar. The power cable is in the CCD briefcase. 16. For CCD observing: take the table from the south-east corner of the dome and place it next to the telescope pillar. Put the CCD briefcase and the laptop here, as well as any documentation to be used. 17. For CCD observing: plug in the laptop.

3 18. For CCD observing: plug in the USB cable in the CCD and in the laptop. The USB cable is in the CCD briefcase. 19. Turn the telescope ON. 20. Allow the telescope to get a GPS fix. 21. If necessary, focus the telescope. Slew to a bright object, unlock the primary mirror lock, and use the coarse focus knob. Once close to focus, re-lock the primary mirror lock and use the telescope microfocuser (using the Autostar keypad) to complete focusing. Focus for eyepiece observing is attained by rotating the coarse focus knob clockwise, if the previous focus setting was for CCD imaging, and vice versa. Focusing with the eyepiece is trivial. For CCD observations, see section 5 below. 3. Finder scope alignment This is done in eyepiece observing mode. Have the scope slew to a bright star in the sky. Use fine motor movements to get the star in the center of the field of view of the telescope. Adjust the screws on the finder scope so that the star lies in the center of the cross-hairs. 4. Use of the Autostar Keypad Some noteworthy facts: the Mode button is like Back on a web browser: it will return you to the previous menu; the bottom two arrows are to scroll through the menu you are currently in, whereas the D-Pad on the top is used for manually slewing the scope, focusing, etc; the Enter key is self explanatory. 4.1. Selecting an Object 4.1.1. Selecting a Named Object Use keys to select Object From here there is a variety of objects to choose from, Deep Sky, Solar System, Stars, etc.. choose you object by going through the subsequent menus, and then hit Go To The scope will slew to the object, however, some fine tuning is required to actually get it in the field of view. A good way to make this easier, is to make sure your finder scope is aligned before you start your observing run (see section 3).

4 4.1.2. Selecting a New, Unnamed Object Use keys to select Object : User. Give the object a name and then input its coordinates and magnitude through the keypad. Press Go To to slew to the new object. 4.2. Finding a Faint Object Telescope was polar-aligned on Feb 8, 2010. Pointing accuracy is to within 0.2 degrees (NB: the FOV of with the 26mm eyepiece is 26 ). The finder scope is also very well aligned to the eyepiece ( 0.1 ), and if centered on the cross-hairs, a star should be within the 25 FOV of the CCD camera. Procedure: 1. If necessary, enter the coordinates of your objects under Object : User object (see 4.1.2). 2. Go to a bright (naked-eye) star nearby (within 5 10 ). The star will be off-center, but should be close to the cross-hairs of the finder scope ( 1/5 of the finder scope FOV). 3. Press and hold the ENTER button on the keypad for >2 seconds, and then release it. The Autostar display now says Press ENTER to Sync... 4. Position the bright star near the center of the CCD camera with the paddle. If your star is very far off, you may need to first find it. To do this efficiently, make sure that your CCD is continuously taking short exposures. All this time, Autostar is recording the telescope motion commands that you are issuing between where it thought the star was, and where you tell it the stars is. Note that for the recommended CCD mounting procedure (see item 14 in Section 2), North on the CCD is to the left and East is down. 5. Press ENTER again. Now the Autostar software has a recorded the pointing correction that you gave it. 6. Slew directly to your science target, by selecting it in the Object list. Your target will now land at the same position on the CCD where the bright star was. NB: The program Stellarium was found to be quite useful as a check of pointing, with star catalogs displaying down to 14 mag stars. In particular, the program shows the size of the selected FOV. Essentially, Stellarium was a fancy finder chart, displaying object coordinates.

5 4.3. Telescope (Polar) Alignment You should not have to align the telescope, if you do make sure to first consult someone who knows the process as it is intensive, slightly confusing, and time consuming. Relevant information is in Appendix A of the Meade manual. Don t forget to the set the telescope Park Position. 5. Focusing the CCD This section has been superseded by the steps described in A Stony Brook Student s Guide to Using CCDSoft (Zajac 2012). Make sure you are looking at a star or grouping of stars. To focus the CCD, first unlock the mirror (rotate mirror lock clockwise). Then, click the focus button in CCDOps5, set the intervals for exposure and delay to your liking. When the program is running the delay portion, turn the coarse focus nob in and out until you achieve the best possible result (turn the doughnuts into point sources). Then lock the mirror (rotate mirror lock counterclockwise). Use Fine focus with Meade keypad to achieve more accurate focus. Hitting Focus on the keypad will allow you to adjust focus speed using the bottom two arrows. Using the top up and down arrows in this menu will adjust the actual focus. When you are done, simply close the focusing program. 6. Using of SBIG CCDOps Software This section has been superseded by the steps described in A Stony Brook Student s Guide to Using CCDSoft (Zajac 2012). 6.1. Starting Up Turn on the laptop. Select DOS as the operating system once it powers up. If you miss this chance (you have 3 seconds), wait for it to fully power up in Linux and then restart it. Login to Windows. Username: ccd, password: SBIGCCD Start up CCDOps 5; icon is on the Desktop Hit the button that says EstLnk to establish a link to the CCD. Click the tab that says Filter and click Cali- Calibrate/Initialize filter wheel. brate/initialize...

6 6.2. Taking an image To take an image using the CCD, hit the Grab button in CCDOps5, select the exposure length, and wait. Be sure to take flat field s at the beginning or at the end of the night so that your data can be reduced. Do not worry about taking dark fields, as they are automatically subtracted during the exposure (make sure the you check the box that refers to taking the dark image). You can also take a series of images. In the Grab dialog box select Auto Grab from the Signal Processing pull-down menu. The Auto Grab Setup dialog will pop up. Set up a name and destination directory for the series of images, select the number of exposures that you wish to take, the interval between consecutive exposures, and the number of exposures between consecutive dark frames. The latter is selected in the Dark interval pull-down menu; if you selecte the Series option, only one dark frame will be taken for the entire series. 6.3. Changing filters To change the filter, click the tab that says Filter, and select which one you want. A loading image will pop up, and close when the filter is changed. 7. Shut-Down Procedure 1. PARK THE TELESCOPE! Failure to do so will result in it forgetting where it was pointed and need for re-alignment next time it is powered up. To park the telescope, go to the Utilities section of the AutoStar controller. If this doesn t work, use the keypad to move the telescope to point South, with the optical tube app. perpendicular to the fork. 2. For CCD observing: Transfer your data on a USB stick; can be done also later. 3. For CCD observing: Turn off the computer, disconnect the CCD from the telescope and the computer, remove the mounting bracket from the front of the CCD and replace its screw cap. Put the CCD, all the CCD cabling, and the CCD manual in its briefcase. 4. For CCD observing: Remove the counterweight form the telescope tube. 5. For eyepiece observing: Remove the eyepiece and put all eyepieces back in the eyepiece case. 6. Power OFF the telescope.

7 7. Unplug the telescope from the mount and wrap its cable around the telescope mount. 8. Replace the telescope front cap, as well as finderscope and eyepiece caps. 9. Cover the telescope with the grey canvas cover. 10. Rotate the dome so that the dome slit is over the entrance door. 11. Close the lower dome shutter. 12. Close the top dome shutter. 13. Shut off the power to the dome. 14. Fill out the telescope logbook. 15. Collect the CCD, laptop, eyepieces, manuals, your personal belongings, and any trash before leaving. 16. Turn off all lights and close both doors. 17. If any problems were encountered with the telescope or with the CCD during the night, notify any of the astronomy faculty in charge of the telescope (von der Linden, Zingale, Calder).