Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45

Similar documents
Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6A Shielded Connection Module

NGBASE-T Cabling Requirements

TIA TR-42 Liaison to IEEE

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Certification for 10G copper cabling

Test Report modcon - PS88A6M

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Chapter 4: Network Access. Introduction to Networks v5.1

ISO/IEC TR Guidance on 40GBASE-T T Cabling

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity

ANSI/TIA-568-C Cat 6 Field Test Specifications

ANSI/TIA-568-C Cat 6A Field Test Specifications

Telegärtner Point of View

Cat.8 Shielded Field Termination Plug Description

10G Ethernet Over Structured Copper Cabling

INTERNATIONAL STANDARD

Cabling Infrastructure

40G BASE-T Cabling Infrastructure. Allan Nielsen Standards Manager

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

IEEE 802.3cg MDI connector Limitations. Amrik Bains - Cisco Systems George Curtis - Cisco Systems Ed Kliewer - Cisco Systems

Corrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises

PE310G4TSF4I71 Quad Port SFP+ 10 Gigabit Ethernet PCI Express Time Stamp Server Adapter Intel Based

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Link Segment Considerations Industrial Applications IEEE Mb/s Single Twisted Pair Ethernet Study Group. San Antonio, Texas November 2016

Single-pair cabling channel specifications

Understanding 3M Ultra Hard Metric (UHM) Connectors

40GBASE-T Cabling channel MDI-to-MDI

Cat.8 Shielded Keystone Jack Description

AMP-TWIST* 6S Series SL Jack

Network Media and Layer 1 Functionality

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

TN-5308 Quick Installation Guide

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Size of the Category 7 A Installed Base

Cable into the Future: Industrial Ethernet with 10 Gbps

IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force (10SPE)

Agilent U2751A USB Modular Switch Matrix. Data Sheet

INTERNATIONAL STANDARD

Datasheet: DSX CableAnalyzer Series

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Cabling for Data Centres. Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions

INTERNATIONAL STANDARD

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

Balanced single-pair cabling channel specifications

LANmark-6 10G LANmark-6 A

LCS² Cat. 6A RJ45 Socket

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

The Impact of Internet of Things (IoT) on Cable Certification

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

9/27/04 cci Cablecom Inc. 1

Closing Report. IEEE Working Group 25GBASE-T Call For Interest David Chalupsky, Intel. San Antonio, Texas November 6, 2014.

NBASE-T and IEEE802.3bz Ethernet Testing 7 MARCH 2016

POWERLINE SIGNAL COUPLERS xx for Intellon INT6300/INT6400 Designs

07. har-link Interface Connectors

History of Standards

How new testing standards affect you Singapore, Nov 2009

10G the Next Generation Structured Cabling. Technology Paper 002

NGAuto Channel Modeling and Analysis

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

07. har-link INTERFACE CONNECTORS

Standards Update. by Paul Kish NORDX/CDT

Certificate bundle. KELine components Cat.6 A, Cat.7, Cat.7 A. from independent testing laboratories. for KELine Structured Cabling

Performance specification for the Fluke DSP Fluke Corporation

ISO/IEC 11801: (E)

Cat 6 (500 MHz) UTP solid cable (PVC sheath)

Using ScTP Patch Cords for Mitigating Alien Crosstalk

CHAPTER 7 Copper Cable Testing

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

RJ point five CONNECTOR SYSTEM

NGEAB-T Use Case ad hoc February 6, 2015

Technical Committee. Addendum to ATM Physical Medium Dependent Interface Specification for 155 Mb/s Over Twisted Pair Cable (af-phy-0015.

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Faults on the system Proximity switch connection technology:

HCI 2017 Products Catalogue

Pro 21/Galea/Sistena socket for LCS 6 Category 6

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

The AMP NETCONNECT Category 6 Cabling System

OPTICAL SOLUTIONS & INFRASTRUCTURE

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017

Ronald Tellas, Technology and Applications Manager, Enterprise Networking

Family of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits

AN_8430_002 April 2011

UTP Cat 5e cable (200 MHz) (PVC sheath)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Link Segment IEEE Mb/s Single Twisted Pair Ethernet Study Group Chris DiMinico MC Communications/Panduit

Classical Ethernet (10 Mbps)

07. har-link Interface Connectors

Transcription:

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC 61076-3-110 Augmented RJ45 Rich Marowsky, Bel Stewart Yakov Belopolsky, Bel Stewart IEEE P802.3bq 40GBASE-T Task force San Antonio TX, USA, November 2014 1

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC 61076-3-110 Augmented RJ45 Abstract The objective of this contribution in support of IEEE 802.3bq 40GbE standard development is to provide direct test data for copper cable channels utilizing the standard connectors per IEC/ISO 61076-3-110 (Augmented RJ45). The data covers a variety of channels: 5m, 7m, 10m, 30m and 50m constructed with several cables. Testing was done in 2 GHz and 3 GHz spectra. Data demonstrated that use of IEC/ISO 61076-3-110 connectivity resulted in channels with improved transmission characteristics RL. NEXT, ACR, etc. The availability of copper connectivity is vital for implementation of 40GbE technology. 2

Rationale: The copper cabling channels of improved transmission parameters Return loss, NEXT, ACRF, TCL are needed to make the market adoption of 40GbE possible. USERS CONCERNS Length of copper cabling (up to 30 m) may not address some applications Copper channels can provide only marginal transmission performance Complex PHY and DSP would be needed to compensate for marginal transmission abilities of copper 40GbE may have very high energy requirements RJ45 connectivity may not provide enough safety margin for robust implementation 3

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC 61076-3-110 Augmented RJ45 ChX CORD1 Horizontal CORD2 Overall length 4

STANDARD CONNECTOR INTERFACES reviewed in this presentation IEC 60603-7 8-CONTACTS Category 3 to 6 A, Proposed category 8.1 IEC 61076-3-110 8-CONTACTS Category 7 A Proposed category 8.2 5 5

COMPENSATION vs. ISOLATION Major difference between proposed 8.1 and 8.2 RJ45 8-CONTACTS Proposed category 8.1 RJ45 use COMPENSATION to reduce differential NEXT. Method of creating the crosstalk equal in amplitude but opposite in phase by adding capacitive and inductive elements Augmented RJ45 8-CONTACTS Proposed category 8.2 Augmented RJ45 use ISOLATION to avoid differential NEXT. Faraday cage is built around each differential pair. 6 6

Proposed CATEGORY 8.1 and 8.2 Connectivity NOT mutually exclusive All Standard Connectors Utilize 8-wire Patch Cords RJ45 plug Proposed Category 8.2 plug Category 6 shielded RJ45 plug is shown combined with Augmented RJ45 Plug in same patch cord 7

7m IEC 61076-3-110 Augmented RJ45 2-3-2 Channel Ch1 8

30m IEC 61076-3-110 Augmented RJ45 2-26-2 Channel Ch8 Commercially Available Products 9

IEC 61076-3-110 Augmented RJ45 Channel Insertion Loss 30m 2+26+2 7m 2+3+2 Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 10

IEC 61076-3-110 Augmented RJ45 Channel Return Loss 30m 2+26+2 7m 2+3+2 Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 11

IEC 61076-3-110 Augmented RJ45 Channel NEXT 30m 2+26+2 7m 2+3+2 Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 12

IEC 61076-3-110 Augmented RJ45 Channel PS NEXT 30m 2+26+2 7m 2+3+2 D Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 13

IEC 61076-3-110 Augmented RJ45 Channel ACR-F 30m 2+26+2 7m 2+3+2 Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 14

IEC 61076-3-110 Augmented RJ45 Channel PS ACR-F 30m 2+26+2 7m 2+3+2 D Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 15

Channel ACR-N 30m 2+26+2 7m 2+3+2 D Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 16

Channel PS ACR-N 30m 2+26+2 7m 2+3+2 D Ch8 Ch1 End-to-End 4-connector channel. MDI connectors included 17

7m IEC 61076-3-110 Augmented RJ45 CHANNEL 1+5+1 Ch2 Ch2 18

7m IEC 61076-3-110 Augmented RJ45 CHANNEL 1+5+1 Ch2 Ch2 19

10m IEC 61076-3-110 Augmented RJ45 Channel 1+6.5+2.5 NEXT Ch4 30m IEC 61076-3-110 Augmented RJ45 Channel 2+26+2 RL Ch7 20

50m IEC 61076-3-110 Augmented RJ45 CHANNEL 2+46+2 Ch10 3000MHz Ch10 3000MHz 21

50m IEC 61076-3-110 Augmented RJ45 CHANNEL 2+46+2 Ch10 3000MHz Ch10 3000MHz 22

Measurement Data Summary A RL 23

Measurement Data Summary Use of IEC/ISO 61076-3-110 Standard Interface connectors resulted in significant improvement of transmission characteristics as compared to requirements of Category 8 PN-568-C-2-1-Draft 2.0c B NEXT 24

CONCLUSION Multiple tests demonstrated that IEC 61076-3-110 Connectivity can support 40GbE transmission in short and longer channels and should be considered for IEEE 802.3bq as an option for MDI connector interface 25