Transmittedlight TL BFDF (MDG 29) User Manual

Similar documents
eica-microsystems.com

Leica IsoPro Automated Cross-stage. User manual

Transmitted Light Bases TL RC (MDG 32) TL RCI (MDG 30) User Manual

Leica EM RAPID. Pharmaceutical Milling System for Pills

Leica EM KMR2. Glass Knifemaker for EM and LM Applications

Precision Cryoembedding System

Leica EM AFS2 Automatic Freeze Substitution System. Leica EM FSP Freeze Substitution Processor

Leica M525 MC1. The versatile surgical microscope for microsurgery

Leica DMS1000. System Diagram

Leica Application Suite. Archive

Leica TL3000 ST Leica TL4000 BFDF Leica TL4000 RC /RCI Leica TL5000 Ergo. Technical Data

Leica EM AMW. Automatic Microwave Tissue Processor for Electron Microscopy

Leica DM2500 M. Simply Microscopy! Blazing New Trails in the Material Sciences

Observe and Document in the Best Light

Leica ST High Throughput. Linear Staining System

Leica E Series. Technical information. Living up to Life

INDUSTRY DIVISION. Leica LED2000 & Leica LED2500. Microscope Stand and Illumination in One

Mar No.02. widefield Application Letter. resolution. Well Plate Acquisition Wizard

Leica DM E. Compound Microscope System. Great discoveries begin with vision.

MYcroscopy As Unique As You Are!

Leica EM KMR3. Balanced-break Glass Knife Maker

Leica DMD108. Modern Network Imaging Solution for Laboratories

Leica FL800. Integrated Vascular Fluorescence. Living up to Life

Leica EM TXP. Target Surfacing System

Leica QWin and Imaging Workstations

Leica LAS Live Image Builder

Leica EZ5. User manual

ww.stereozoom.com Leica StereoZoom Technical information

Leica EM RES101. Ion Beam Milling System for TEM, SEM and LM Preparation

From Eye to Insight. Leica DM2700 M. The reliable and convenient upright materials microscope with bright universal LED illumination.

Table of Contents. The Leica A60 S Congratulations! 13 An Overview of the Leica A60 S 14

MYcroscopy As Unique As You Are!

Leica EM PACT2 High Pressure Freezer. Leica EM RTS Rapid Transfer System

Leica EM TIC020. Triple Ion-Beam Cutter for Easy Site Specific Sample Preparation

Leica SM2500. Leica SP2600. Large Scale Heavy-Duty Sectioning System. and. Ultramilling Attachment

Leica EM CPD300. Automated Critical Point Dryer Controlled Specimen Drying for Biological and Industrial Applications

Leica DM2700 M. The reliable and convenient upright materials microscope with bright universal LED illumination.

TL3000 Ergo Transmitted Light Base User Manual

Operation Manual. for Micromas ter I Micros copes. T his manual covers catalog numbers : S 11031, S 11033, and S 11035

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Leica EZ4 and Leica EZ4 W

Leica DM IL. Inverted Microscope for all Routine and Laboratory Applications in Biology and Medicine

Brilliant, Easy Imaging at the Speed of Light

Leica M50, M60 and M80. Living up to Life

Living up to Life. User Manual. Leica TL5000 Ergo Transmitted Light Base

Leica EM ACE Coaters Cleaning Procedure. Version 06/14

Leica DM750 M Leica DM1750 M Leica DM2500 M. Upright Microscopes for Routine Applications in Materials Examinations

Richter Optica. Instructions for Model: HSX1 High School Microscope

Leica M50, M60 and M80. Routine stereomicroscopes for manufacturing, assembly, inspection, quality control, and failure analysis.

M40 Microscope User s Manual

Leica DFC295 & DFC290 HD. Microscope Cameras for Efficient and Comfortable Documentation

Leica M525 F20. Easy-to-Position Microscope for Precise ENT Surgery. Living up to Life

Leica M205 A, M205 C, M165 C, and M125. FusionOptics : High Resolution and High Depth of Field Simultaneously

Leica TCS SP5 X. X-citing Life The Only Confocal That Tunes Into Any Excitation

TECHNICAL INFORMATION

INDUSTRY DIVISION. Leica DMC2900. Digital microscope camera for easy, efficient documentation and presentation in industry and research

Leica LED2000 / LED2500 User Manual

CL-15.1 OPERATION MANUAL OPTIKA

Leica M220 F12. Microscope for Routine Ophthalmic Surgery. Living up to Life

ESV3000 ETDRS Illuminated Cabinet INSTRUCTION MANUAL

Leica E-Serie - Instruction manual

Swift SM100 Series Stereo Microscope

Leica KL200 LED / Leica L2

Leica DM4000 M Leica DM6000 M. Leica DigitalMicroscopes for Materials Sciences

OLYMPUS STEREO MICROSCOPES I INSTRUCTION MANUAL I MODELS VMF,VMT&VMZ OLYMPUS

Leica IMS500 HD Manual

Leica DM1000 Leica DM2000 Leica DM2500 Leica DM3000. MYcroscopy As Unique As You Are! Microscopy tailored to you

Leica DM ILM. Inverted Microscope for Material Control. Living up to Life

Leica DM750 M Leica DM1750 M Leica DM2700 M. Upright Microscopes for Routine Applications in Materials Examinations

Operating Instructions

BIOLOGICAL MICROSCOPE

Leica M420. Macroscope for high-precision work in documentation, inspection and measurement

Leica TCS SP2. Spectral Confocal & Multiphoton System

Mi50 Inverted Microscope User s Manual. Fein.

Leica DCM 3D. Dual Core 3D Profiler combines Confocal Imaging and Interferometry. Living up to Life

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

Leica M205 A, Leica M205 C, Leica M165 C & Leica M125. Stereomicroscopes Technical Information

Leica SmartTouch Manual

Swift SM100 Series Stereo Microscope

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Eco D-ELS-4 Stereo Microscope. Instruction Manual

Leica BM E. Compound Microscope System Great discoveries begin with vision.

OMM200 and OMM200T. Metallurgical Microscope

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

STEREO MICROSCOPE MODEL K400 / K500 / K700 INSTRUCTION MANUAL

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

C-pan arm USERS INSTRUCTIONS

Application Note. Microwave Embedding in Araldite. related instrument Leica EM AMW. Material Research. Life Science Research. Industrial Manufacturing

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

From Eye to Insight FAST DETECTION FAST ACTION. DM3 XL Inspection System. Microelectronics and Semiconductor Industry

Power Series Camera Support

Chapter overview. The Leica ICC Get Ready! 12. Get Set! 15. Go! 22. Care and Cleaning 24. Specifications 26. Leica ICC 50 Manual 2

Operation Manual (Version 1.0.0)

TECHNICAL INFORMATION

Leica M50 & M80. Stereomicroscopes Technical Information. Living up to Life

For Quality that Lasts Leica EZ4 StereoZoom and EZ4 D (Documentation) Stereomicroscopes for Assembly, Inspection, and Quality Control

tereomicroscopy.com Leica MS5 and MZ6 The most flexible routine stereomicroscopes in the world

MANUAL 3072 STEREO MICROSCOPE SERIES

Polarization Microscope. Omano OM349P Series. User Guide

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

Transcription:

Transmittedlight Base TL BFDF (MDG 29) User Manual

Contents Page Overviews Safety concept......................................... 4 Symbols............................................... 5 Safety regulations....................................... 6 Controls............................................... 8 Assembly First steps............................................. 10 Removing the transport anchors......................... 11 Unpacking and assembling the various components........ 12 Operation Light intensity.......................................... 14 Transmitted-light control................................ 14 IsoPro cross-stage................................... 14 Care, maintenance..................................... 15 Expansion diagram..................................... 16 Scope of delivery...................................... 17 Dimensions........................................... 18 Technical data........................................ 19 2 TL BFDF transmitted-light base Contents

Dear User Thank you very much for your trust in Leica Microsystems. We hope you will enjoy working with our high-quality, efficient products, and wish you much success. In developing our instruments, we put much emphasis on a simple, self-explanatory operation. However, take your time to read the user manual, in order to familiarize yourself with your stereomicroscope for optimal use of all its benefits and options. Should you have any questions, please consult your local Leica representative. You will find the address of the closest local representative, as well as valuable information about products and services from Leica Microsystems on our homepage at www.leica-microsystems.com We are gladly at your service. CUSTOMER SERVICE is a big thing with us. Not only before the sale, but afterwards as well. The user manual This user manual is available in 20 additional languages on our interactive CD-ROM. User manuals and updates are also available for download on our homepage at www.leica-microsystems.com. The user manual at hand describes safety instructions, assembly, and handling of the TL BFDF transmitted-light base. TL BFDF transmitted-light base Contents

Safety concept 1.1 The user manual The TL BFDF transmitted-light base comes with an interactive CD-ROM containing all relevant instructions in 20 additional languages. Keep this CD-ROM in a safe place, where it is available to the user. User manuals and updates are also available for download and printout on our homepage at www.stereomicroscopy.com. The TL BFDF transmitted-light base is a module in the Leica M stereomicroscope series. This user manual describes the special functions of the transmitted-light base and contains important instructions for operating safety, maintenance and the accessory parts. Before assembly, start up and use, please read the user manuals mentioned above. In particular, please observe all safety instructions. To maintain the unit in its original condition and to ensure safe operation, the user must follow the instructions and warnings contained in these user manuals. The M2-105-0 user manual for the Leica M stereomicroscopes contains additional safety rules for the stereomicroscope, accessories and electrical accessories, as well as instructions for maintenance. 4 TL BFDF transmitted-light base Safety concept

1.1.1 Symbols used Warning of danger This symbol indicates information, which must be read and obeyed. Disregarding these instructions can cause personal harm! can lead to malfunction and damage to instruments. Warning of dangerous electrical voltage This symbol indicates information, which must be read and obeyed. Disregarding these instructions can cause personal harm! can lead to malfunction and damage to instruments. Warning - hot surface This symbol warns against touching hot surfaces, e.g. those of light bulbs. Important information This symbol indicates additional information or explanations that intend to provide clarity. Action E This symbol within the text indicates that certain actions must be carried out. Explanatory notes This symbol indicates additional notes and explanations provided in the text. Figures (1.5) Numbers in brackets within the descriptions relate to the figures and the items within those figures. Example (1.3): Figure 1 is located, for example, on Page 8, and item 3 is the adjustment button for the light intensity. TL BFDF transmitted-light base Safety concept 5

1.2 Safety regulations Description The TL BFDF transmitted-light base fulfills the highest requirements for observation and documentation of the Leica M-series stereomicroscopes. It contains a path-folding mirror, a device for partial pupil illumination and relief contrast generation, a ground-glass screen, an additional condenser and Fresnel lenses. The complete stand consists of: TL BFDF transmitted-light base Column 300 mm or 500 mm long with focusing drive, manual coarse/fine or motorized focus Glass stage plate, clear, 220 170 4mm external cold light source of your choice Accessories: Gliding stage Leica MATS Thermocontrol System with heating stage Polarization set and many more (see Expansion diagram) Intended uses The TL BFDF transmitted-light base is used for assembling Leica M series stereomicroscopes with column and microscope carrier. Units or accessories described in the user manual have been checked for safety and possible dangers. For any changes to the instrument, modifications or combinations with non-leica components that exceed the scope of this manual, consult the appropriate Leica office or the Leica headquarters in Wetzlar! Unauthorized changes of the unit or improper use renders the warranty null and void. Place of use Only use the TL BFDF transmitted-light base in closed, dust free rooms and between +10 C and +40 C. Make sure that the rooms are free of oil vapors or other chemical vapors, and extreme humidity. Set up the electrical components at least 10cm from walls and combustible objects. Avoid large deviations in temperature, direct sunlight and shocks. This can cause faulty measurements or microphotographs. In warm, or warm and humid climates, the TL BFDF transmitted-light base requires special care to prevent formation of fungus. Prohibited uses Using the transmitted-light base TL BFDF, its components, and accessories in a way contrary to this user manual, can lead to bodily harm and damage to objects. Never: change, rebuild or take apart parts, if not specifically instructed to in this manual. allow non-authorized persons to open parts of the instrument. use the TL BFDF transmitted-light base for examination and surgery of the human eye. 6 TL BFDF transmitted-light base Safety concept

Operator responsibilities Make sure that only authorized and trained personnel is allowed to operate, maintain and repair the TL BFDF transmitted-light base and its accessories. all operators have read, understood and observe this user manual, and particularly the safety instructions. Repairs, Service Only Leica Microsystems trained service personnel or authorized technicians of your company should repair the equipment. Only use original Leica Microsystems parts. Before opening the devices, turn off the power and unplug the main power cables. Avoid contact with powered electrical circuits which can lead to injury. Transport Use the original packaging for shipping or transporting the TL BFDF transmitted-light base and the accessory components. To prevent damage by vibrations, remove and separately pack all the moving components which you have installed yourself (as outlined in the User Manual) and install the transport anchors. Integration in third-party products The following must be observed if Leica products are built into third-party products: The manufacturer of the complete system or the person putting it on the market is responsible for adhering to applicable safety regulations, laws and guidelines. Disposal The products described here must be disposed off in accordance with applicable local environmental laws and regulations. Legal requirements Adhere to general and local regulations relating to accident prevention and environmental protection. EC declaration of conformity The TL BFDF transmitted-light base and the accessories have been constructed according to the state of the art and issued with an EC declaration of conformity. TL BFDF transmitted-light base Safety concept 7

Controls 1 2 3 Fig. 1 Leica MZ16 with ErgoTube, coarse/ fine drive, TL BFDF transmitted-light base, standard stage and 4 slides 1 Adapter plate for easy assembly of focusing drives 2 Standard stage 10 447 269 3 Button to toggle between bright field and dark field 8 TL BFDF transmitted-light base Controls

Fig. 2 TL BFDF transmitted-light base adapter plate Fig. 3 Adapter at the focusing drive 1 Fig. 4 Button to toggle between bright field/ dark field (here: Button in dark field position) Fig. 5 Rear side of TL BFDF transmitted-light base 1 Connector for cold light sources (light conductor active f = 10mm, end tube f = 13mm) TL BFDF transmitted-light base Controls 9

Important information before first use Unpacking the Leica BFDF transmitted-light base Unpack the base on an adequately sized, level and nonskid underlay. Read and understand the User Manual included with this transmitted-light base. 10 TL BFDF transmitted-light base Unpacking

Removing the transport anchors Before you can use the transmitted-light base for the first time, it is absolutely necessary to remove the two transport anchors as follows: from the rear side of the transmitted-light base - remove anchor of the switching slide from the top of the base - remove the anchor of the mirror TL BFDF transmitted-light base Transport anchors 11

Assembly Before unpacking, make sure no persons can be injured by falling or tilting parts. 3.1 Unpacking the base The base is delivered with the adapter plate attached. The selected stage (IsoPro crossstage or standard stage 10 447 269), and the focusing drive will have to be mounted later. Make sure the devices are unpacked on a flat, sufficiently dimensioned, and non-slip surface. 3.2 Stage assembly The TL BFDF transmitted-light base can be equipped with two different stages. The selected stage is mounted on the base before startup. The two stages can be easily exchanged at any time. The following paragraph assumes the base without the stage mounted. Disassembly is performed in reverse order of the following steps. 3.2.1 Standard stage E Take the glass plate from the rectangular gap in the standard stage. E Position the stage on the transmitted-light base in such way that the four holes align over those in the base. E Attach the stage to the base with the four supplied Allen screws. E Re-insert the glass plate back into the standard stage. 3.2.2 IsoPro cross-stage Before the IsoPro cross-stage is mounted to the base, the axis containing the control buttons is attached either on the left or the right side of the cross-stage. If the controls shall be mounted on the left hand side, the gear rod on the bottom side of the crossstage must be unscrewed and re-attached in reverse. E Take the glass plate from the cross-stage. E Turn the cross-stage around and place it onto a non-slip surface. E Change the gear rod (6.2) from the left to the right hand side. E Skip the next two steps to mount the controls. Control assembly E Take the glass plate from the cross-stage. E Turn the cross-stage around and place it onto a non-slip surface. E Attach the axis with the control buttons (6.1) to the desired side. The fastener snaps into the cross-stage magnetically. E Attach the axis with the two supplied Allen screws. E Attach the cover rail to the cross-stage. Cross-stage assembly E Place the cross-stage onto the base. E Pull the upper part of the cross-stage carefully toward the user, fixing the lower part onto the transmitted-light base. E Attach the cross-stage evenly to the three threaded holes. E Push the cross-stage all the way back to the fence in direction of column. E Re-insert the glass plate back into the standard stage. 12 TL BFDF transmitted-light base Assembly

3.3 Focusing drive > column E Unscrew the adapter plate (1.1) from the base using the supplied Allen key. E Attach your focusing drive column to the bottom with the three Allen screws (2). E Re-attach the adapter plate to its original position with the three Allen screws. 3.4 Intermediate adapter assembly The distance between focusing and optical axis is larger on the new TL BFDF transmitted-light base. To balance this, mount the supplied adapter between column and microscope carrier. E Attach the adapter (3) to the focusing drive for the pins to lock in recess. E Attach the adapter using the supplied Allen key. 1 Fig 6 Rear side of IsoPro cross-stage 1 Axis with controls 2 Gear rack, mounted to cross-stage 2 3.5 Equipment assembly Once the adapter is mounted to the focusing drive the microscope carrier, optics carrier and the entire equipment can be assembled as usual. 3.6 Connecting the cold light-source to the TL BFDF transmitted-light base E Push the appropriate end of the cold light guide into the rear side of the base. E For further information about the use of cold light sources refer to the instructions supplied separately. 1 2 Fig. 7 Cross-stage controls 1 Control button for x-direction movement 2 Control button for y-direction movement TL BFDF transmitted-light base Assembly 13

Operation 4.1 Light intensity control Please observe the user manual and in particular the safety regulations of the manufacturers of the light guide and cold light source. E Turn on the cold light source according to the manufacturer's user manual and connect, activate, and adjust the light intensity. 4.3 Operating the cross-stage IsoPro E To move the stage in X direction rotate the outer knob (7.1) E To move the stage in Y direction rotate the inner control ring (7.2) 4.2 Transmitted-light control The TL BFDF transmitted-light base has a potentiometer that switches the light from "bright field" to "dark field". 4.2.1 Bright field Bright field is suited for transparent objects with structures that are rich in contrast. The object is illuminated directly from the bottom to appear pin sharp and in natural colors on a bright surface. E Turn the control button to limit "BF" ("bright field"). 4.2.2 Dark field Ring illumination is used for dark field illumination, so that no direct light reaches the objective without an object. Only the structure of semi-transparent, opaque objects, like foraminifera or fish eggs, disperse the light, making the object visible against a dark surface. E Turn the control button to limit "DF" ("dark field"). 14 TL BFDF transmitted-light base Operation

Care, maintenance In this chapter We guarantee quality we would like to explain and help you understand the careful handling of your valuable instrument, and provide you with some tips for proper maintenance and cleaning. You are using a precision instrument with many performance features. As appropriate for such instruments we guarantee the quality of our products. This guarantee covers all manufacturing and material defects of the original equipment, but not any damages that are the result of inappropriate use or negligence. Please handle your valuable optical instrument with the appropriate care. If you do so you will be able to enjoy many decades of accurate service by this equipment without any deterioration. This is the reputation of our equipment. Should your equipment, however, no longer provide accurate service, please contact your authorized service representative, your Leica distributor or directly Leica Microsystems (Switzerland) Ltd., CH-9435 Heerbrugg. Protect your instruments Protect from moisture, fumes, acids, bases and corrosive materials. Do not store any chemicals in close proximity of the instrument. Protect from inappropriate use or handling. Never use off-brand electrical connectors or wires; never disassemble optical systems or mechanical components, if no particular reference is made to that purpose in the instructions. Protect from oil and grease. Slide surfaces and mechanical components shall never be lubricated. TL BFDF transmitted-light base Care, maintenance 15

Expansion diagram 11 101 784 10 447 392 10 445 615 (300mm) 10 446 100 (500mm) 10 447 391 10 446 303 10 447 276 10 446 304 10 447 275 10 447 106 (300mm) 10 447 185 (500mm) 10 446 228 10 446 301 10 446 302 10 382 130 10 361 719 10 446 353 10 447 269 10 446 176 (300mm) 10 447 041 (500mm) 10 447 368 10 446 352 10 447 390 10 446 351 10 446 340 10 447 342 10 446 350 10 447 393 10 447 394 10 447 395 10 447 400 10 446 341 10 447 398 10 447 431 10 447 443 4 / 11.05 16 TL BFDF transmitted-light base Expansion diagram

Scope of delivery Incident-light bases 10 446 340 Incident-light base for S series 10 446 341 Sub-base for transmitted-light for S series incident light base 10 447 342 Incident-light base for M series 10 446 350 TL ST transmitted-light base 10 446 351 TL BFDF transmitted-light base 10 447 390 TL RC transmitted-light base for external cold light sources 10 446 352 TL RCI transmitted-light base with integrated halogen illumination Stages 10 447 269 Standard stage for TL BFDF, TL RC and TL RCI transmitted-light bases 10 446 35 Cross-stage for TL BFDF, TL RC, TL RCI transmitted-light bases and incident-light base (with adapter 10 447 368) 10 447 368 Adapter between cross-stage and 10 447 342 incident light base 10 447 275 Thermo stage Leica MATS TL with controller 10 447 276 Adapter for stages with 120mm 10 447 391 Stage for LifeOnStage accessory 10 447 392 Universal carrier for Petri dish, slides (up to four pieces) etc. 11 101 784 Column adapter for micromanipulation 10 446 301 Sliding stage, 120mm 10 446 302 Polarization stage, 120mm 10 382 130 Object guide for polarization stage 10 361 719 Compensator Red I for Pol rotating stage 10 446 303 Cup stage, 120mm 10 446 304 Universal carrier, 120mm 10 446 228 Glass insert with Pol, 120mm Focusing drives 10 445 615 Focusing drive with profile 300mm column for incident and transmittedlight bases 10 446 100 Focusing drive with profile 500mm column for incident and transmittedlight bases 10 447 106 Focusing drive, coarse/fine, with 300mm profile column for incident and transmitted-light bases 10 447 185 Focusing drive, coarse/fine, with 500mm profile column for incident and transmitted-light bases 10 446 176 Motorized focus drive with 300mm column and power supply for incident and transmitted-light bases 10 447 041 Motorized focus drive with 500mm column and power supply for incident and transmitted-light bases Filter 10 447 400 Day light filter for TL ST base 10 447 394 Fluorescence filter BG38 for transmitted-light bases TL RC / RCI 10 447 395 UV filter for bases TL RC / RCI 10 447 393 Filter ND (gray filter) for bases TL RC / RCI Illumination 10 447 44 Leica USB mouse, five key mouse, freely assignable for connections to transmitted-light bases TL RCI or PC 10 443 401 USB cable to connect TL RCI base to a PC 10 447 398 Foot switch with CAN bus connector Ergonomic Accessories 10 447 431 Leica ErgoRest (palm rest for fatigue-free operation) TL BFDF transmitted-light base Expansion diagram 17

Dimensions transmitted-light base Dimensions in mm 370 154 154 390 116 90 340 18 TL BFDF transmitted-light base Dimensions

Technical data Leica TL BFDF Light source external via cold light source Illuminated area 40mm Connections Connection for cold light conductor, active f=10mm, end tube f=13mm Weight 5.8 kg Illumination types Bright field yes Dark field yes Oblique light no Relief Contrast System (RC ) no CCIC no (Constant Color Intensity Control) Internal shutter/lamp control yes* Integrated filter holder no Coated optic to no Raise of color temperature Matching of high num. aperture yes** Remote control possibility yes*** AntiShock Pads yes Size of the base (W H D, in mm) 340 390 90 *with cold light source Leica CLS150 LS **concave mirror *** with external light source TL BFDF transmitted-light base Technical data 19

Leica Microsystems the brand for outstanding products Leica Microsystems mission is to be the world s first-choice provider of innovative solutions to our customers needs for vision, measurement and analysis of micro-structures. Leica, the leading brand for microscopes and scientific instruments, developed from five brand names, all with a long tradition: Wild, Leitz, Reichert, Jung and Cambridge Instruments. Yet Leica symbolizes innovation as well as tradition. Leica Microsystems an international company with a strong network of customer services. Australia: Gladesville Tel. +61 2 9879 9700 Fax +61 2 9817 8358 Austria: Vienna Tel. +43 1 486 80 50 0 Fax +43 1 486 80 50 30 Canada: Richmond Hill/Ontario Tel. +1 905 762 2000 Fax +1 905 762 8937 Denmark: Herlev Tel. +45 4454 0101 Fax +45 4454 0111 France: Rueil-Malmaison Tel. +33 1 47 32 85 85 Fax +33 1 47 32 85 86 Germany: Bensheim Tel. +49 6251 136 0 Fax +49 6251 136 155 Italy: Milan Tel. +39 0257 486.1 Fax +39 0257 40 3475 Japan: Tokyo Tel. + 81 3 5421 2800 Fax +81 3 5421 2896 Korea: Seoul Tel. +82 2 514 65 43 Fax +82 2 514 65 48 Netherlands: Rijswijk Tel. +31 70 4132 100 Fax +31 70 4132 109 People s Rep. of China: Hong Kong Tel. +852 2564 6699 Fax +852 2564 4163 Portugal: Lisbon Tel. +351 21 388 9112 Fax +351 21 385 4668 Singapore Tel. +65 6779 7823 Fax +65 6773 0628 Spain: Barcelona Tel. +34 93 494 95 30 Fax +34 93 494 95 32 Sweden: Sollentuna Tel. +46 8 625 45 45 Fax +46 8 625 45 10 Switzerland: Glattbrugg Tel. +41 44 809 34 34 Fax +41 44 809 34 44 United Kingdom: Milton Keynes Tel. +44 1908 246 246 Fax +44 1908 609 992 USA: Bannockburn/lllinois Tel. +1 847 405 0123 Fax +1 847 405 0164 and representatives of Leica Microsystems in more than 100 countries. In accordance with the ISO 9001 certificate, Leica Microsystems (Switzerland) Ltd, Business Unit Stereo & Macroscope Systems has at its disposal a management system that meets the requirements of the international standard for quality management. In addition, production meets the requirements of the international standard ISO 14001 for environmental management. The companies of the Leica Microsystems Group operate internationally in three business segments, where we rank with the market leaders. Microscopy Systems Our expertise in microscopy is the basis for all our solutions for visualization, measurement and analysis of micro-structures in life sciences and industry. With confocal laser technology and image analysis systems, we provide three-dimensional viewing facilities and offer new solutions for cytogenetics, pathology and materials sciences. Specimen Preparation We provide comprehensive systems and services for clinical histo- and cytopathology applications, biomedical research and industrial quality assurance. Our product range includes instruments, systems and consumables for tissue infiltration and embedding, microtomes and cryostats as well as automated stainers and coverslippers. Medical Equipment Innovative technologies in our surgical microscopes offer new therapeutic approaches in microsurgery. Illustrations, descriptions and technical data are non-binding subject to change without notice. M2-218-1en Leica Microsystems (Switzerland) Ltd CH-9435 Heerbrugg, 2005 en VI.2007 www.leica-microsystems.com