Serverless Page/Party

Similar documents
Page Station Module Replacements Page/Talk, Page/Party & Third-Party

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

Digital Outdoor Intercom Station DA/DAE 0x5 Series

Page/Talk Industrial Desk Sets

(DISTRIBUTED AMPLIFIER BASED DESIGN) (NON BLOCKING TYPE).

N-8000 SERIES IP INTERCOM SYSTEM

Behavioral Health Telephones

Digital Intercom Stations DTM Series

GAI-TRONICS, a Hubbell Company, has been the leading manufacturer in the rugged communications

IP Desktop Intercom Stations 12 NIB 001 Series

Technical Data. General specifications. Rated operating distance s n 3 mm

IP-HVP. PoE+ Vandal and Weather Resistant Wall Mount IP Speaker

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

IP-DM. IP Wall Mount LCD with Microphone

STENTOFON PULSE SERVERLESS INTERCOM

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

IP Speaker System. Users Guide

AUD-340 Installation Guide

AUD-220 Installation Guide

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

STENTOFON PRO700 ExchangElEss IntERcOm

Indoor Industrial Analog Telephones

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

ArmorPoint I/O Field Potential Distributor, Series A

EMS10 - EMS50. Cameo specification sheet. Product Description

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

The Cisco Wireless IP Phone 8821-EX has not been tested or certified with any accessories for use in Potentially Explosive Atmosphere.

Automated Remote Messaging ARM-911A RM-911D RM-911W

Simply Communicate. Analog Partyline Systems

Communications and Control. Plant. Access

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

PI-EX-ME-2NAM/COC-120VAC

10 Industrial Media Converters

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

bi-way starter kit lbb 7026/65 MI v.1.2 mounting guide

General Specifications

PRO700 EXCHANGELESS INTERCOM CRITICAL COMMUNICATION

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Linear Luminaire with LED Series 6012/5

Level-Lance Model 5400A

FLEX Ex Spring Clamp Terminal Base

MPS10 - MPS50. Modular Paging and Emergency Microphones

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

Speaking Station LV30

IP-ZCM. PoE+ IP to Analog Gateway (Zone Controller)

PHOENIX CONTACT - 12/2007

Safety switches with separate actuator

Series Panel Mounted Control Devices

duplex communication (with handset) hands-free talking simplex communication can be activated standard 4 (up to 2 from front-door stations)

PI-EX-ME-2NAM/COC-24VDC

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Modlight30/50/70 Signal Towers

Connexus Communications Limited STENTOFON PULSE Intercom for Everyone

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM

PTC-101 Quick Installation Guide

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

Features and Benefits. Certifications

Safety switches for hinged doors

DVS-21 product catalogue 2015 V1.03. Table of contents:

Background. ii) Noise cancelling microphone. iii) Headset with integral boom microphone. iv) Headset jacking socket box. v) Telephone style handset

Installation Instructions

SPON Communication Technology Co., LTD

ZCM-V2+T. PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T

MPS01. Paging and Emergency Microphone

6MP Explosion Proof Digital Pan Tilt Zoom Security Camera - Pole Top Mount Coverage - C1D1

MA Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Declaration of Conformity

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Voice Alarm System VX-3000 Series

Electrical Actuators

VS-88UT All in One Presentation System with 8x8 4K60 4:2:0 HDMI/HDBaseT 2.0 Matrix Switching, Master Room Controller, PoE & Power Amplifier

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

MOXA EtherDevice Switch

Photoelectric Sensors Enhanced 50 Series

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.

EP/2 Installation Instructions

Electrical Actuators

May 7, :27:07 e ESC FORWARD/ DISPLAY CALLS REDIAL PAGE ALL SOURCE SELECTED HOLD ROOMS SPEAKER CANCEL/ CLEAR PHONE PTT/ ENTER TROUBLE

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

F O R U M S E R I E S

General Specifications

Thread length (overall length) material

Inductive sensor BI5-EM18-Y1X-H1141

Modern, sunlight-readable 7" colour display


Voice Alarm System VX-3000 Series

Safety switches with manual mechanical delay and separate actuator

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Technical Information Promonitor NRF560

DATA SHEET DEVIO DEVIO CR-1 CONFERENCE ROOM DEVICE

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

Linear Luminaire with LED Series 6412/5

ASK-4 #101-DV AUDIO MONITORING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Telephones. GB90 Series Options. Products. New. Jacks Inserts. Modules. Work Area Outlets. Telecom Room. Patch Cords. Video & Coax.

Transcription:

Serverless Page/Party VoIP Multicast Paging and Intercom

is GAI-Tronics most advanced paging and intercom system yet. Combining the simplicity of press to page, release to party operation with cutting-edge multicast Voice over Internet Protocol (VoIP) technology, SP2 is capable of providing virtually instant communication in the most demanding of environments. SP2 is a serverless system. While other systems rely on servers to route calls and administrate the system, SP2 uses multicast technology, bypassing the need for servers and resulting in a number of benefits. SP2 is fast. Since no server is needed to set up call routing and conference bridges, SP2 can provide immediate one way paging and full-duplex party line communication. SP2 is simple. There s no keypad, no extensions to memorize. Simply lift the handset, select a paging zone, squeeze the handset pressbar, and make an announcement over the system speakers. Release the pressbar and talk on one of the five available party lines. SP2 is reliable. There are no servers to fail or update. SP2 will also notify you of any problems via e-mail. SP2 is flexible. Every SP2 station is capable of being configured with unique characteristics, including priority, zone destinations, volume levels and so on. Indoor, weatherproof and hazardous area stations with worldwide approvals are available, ensuring that SP2 can be used everywhere it s needed

SP2 Architecture Network switch (provided by others) SP2 is simply wired to the nearest network switch using CAT5/CAT5E Ethernet cable, or Fiber Optic Cable. Local power is supplied to each station either as a separate power cable or contained in a hybrid power / network cable. Simple screw terminals within the station make field wiring possible without the need for any special tools. Since SP2 is a serverless system, it can easily be integrated into an existing IP network. This can significantly reduce the installation cost of SP2 and simplify plant data architecture. All SP2 stations feature a 30W, class D speaker amplifier. This amplifier is capable of producing paging output of up to 126dB when matched with GAI-Tronics 30W horn / driver combination. SP2 stations can be supplied with a handset, for paging and intercom, or without a handset for where only paging coverage is needed.

SP2 Features and Controls SP2 was designed with the user in mind. SP2 features simple controls that are easily operable while wearing gloves. A handset with a high-output receiver and noise-cancelling microphone ensures clear communication in high noise areas. Rugged Construction Reliable communications in any environment High visibility orange finish Receiver Hearing aid compatible Universal AC Power Worldwide operation Party Line Selector Switch Simple conference calls Paging Pressbar One-handed operation Optional Page Zone Selector Switch Configurable zoning for every SP2 station Dynamic Microphone Built-in noise cancellation ensures clear communication in high noise environments 30 Watt Speaker Amplifier with Ambient Noise Compensation Clear sound in any environment

SP2 Connections Each SP2 station can be expanded with several peripheral devices. A 30W external speaker provides up to 126dB of paging audio A flashing beacon attracts attention in very high noise areas A headset enables handsfree operation in any environment 600Ω A two-way 600Ω audio connection enables simple interfacing with other systems

SP2 Series Variants SP2 stations are available with many different mounting and environmental options, allowing SP2 to be used in every area of the facility. Indoor Wall-mount Stations Indoor Remote-mounted Subset Stations Weatherproof Wall-mount Stations Explosion-proof Stations Zone 2 Stations

Technical Data - SP2 Series Specifications Technical Data - SP2 Series Specifications Electrical Supply Voltage................................. 120/230 V ac Max Power Consumption.......... 400mA / 48.0VA @ 120 Vac Input Frequency Range.............................. 50/60 H Network Requirements......... 100 BaseT network with IGMP Handset Microphone....................... Dynamic, noise-cancelling Microphone Noise Discrimination.............. 18dB @ 250Hz Receiver.................... Dynamic, hearing aid compatible External Control.............. Push-to-page handset pressbar Handset Amplifier Output Level (compression controlled)........ 1.5VRMS nominal Frequency Response....... 250-6,500 Hz, +0/-3dB ref. to 1KHz Distortion...... <1.5% THD @ 1KHz (below compression level) Receiver Level........................... 200mVRMS nominal Network Connection CAT5/5E Stations.......................... Screw Terminals Fiber Optic Station...................... Standard SFP Port Speaker Amplifier Max Output............ 30W into 8Ω load with 1.5VRMS input Frequency Response: Distortion....................... <1% THD @ 1KHz to 24W <3% THD @ 1KHz to 30W Indoor Wall-mount Stations Mechanical Construction........................................................ 16 gauge cold-rolled steel Finish........................................................... Safety orange powder coating Connections................................................ Screw-type barrier terminal blocks Dimensions (overall).................. 12.5 H x 5.25 W x 7.34 D inches (317.5 x 133.4 x 188.4 mm) Temperature range......................................... -22 F to +140 F (-30 C to +60 C) Relative Humidity....................................................... 95%, non-condensing Approvals Electical Safety....................................... Complies with IEC 60950 and UL 60950 CE Mark.................................... Complies with Low Voltage Directive 73/23/EEC, and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC NRTL Listed............................ Hazardous locations, Class I, Div. 2, (USA and Canada) Groups A, B, C, D Indoor Wall-mount SP2 Part Numbers*: SP2 Series Mounting Party Lines Station Type Connection / Control Handset Approval Finish Options Entries 9 1 X X X X X X X 0 Ethernet with RTU 2 Ethernet with ALT Page and RTU 4 Ethernet with All Call and RTU 6 Amp Only 0 Multi Party 5 AC Handset/Speaker 1 AC Handset/Speaker/Aux 2 AC Speaker 3 Fiber with RTU* Fiber with Alt Call and RTU* Fiber with All Call and RTU* B D F Amp Only 0 6 PVC 1 15 PVC 2 25 PVC 3 6 Hytrel 4 15 Hytrel 5 25 Hytrel 6 CE UL CI D2 B S Orange 1 Gray 2 No Options 0 Trop TR A 70/100V R 70/100V, TR S Note: *Fiber optic stations require a suitable SFP module. Contact GAI-Tronics for more information. * Items marked as X are configurable. Not all option combinations are possible please contact GAI-Tronics for assistance.

Technical Data - SP2 Series Specifications Indoor Remote-mounted Subset Stations Remote Amplifier Mechanical Construction........................................................ 16 gauge cold-rolled steel Finish........................................................... Safety orange powder coating Connections................................................ Screw-type barrier terminal blocks DB25 connection to subset Dimensions (overall).................. 12.5 H x 5.25 W x 4.37 D inches (317.5 x 133.4 x 111.1 mm) Temperature range......................................... -22 F to +140 F (-30 C to +60 C) Relative Humidity....................................................... 95%, non-condensing Remote Amplifier SP2 Part Numbers*: SP2 Series Indoor Wall-mount Party Lines Approvals Electical Safety....................................... Complies with IEC 60950 and UL 60950 CE Mark.................................... Complies with Low Voltage Directive 73/23/EEC, and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC Station Type Connection / Control Remote Approval Finish Options Entries 9 3 0 4 X 0 X X X 0 Note: *Fiber optic stations require a suitable SFP module. Contact GAI-Tronics for more information. Ethernet with RTU 2 Fiber with RTU* B UL Safety CE R B Orange 1 Gray 2 No Options 0 Trop TR A 70/100V R 70/100V, TR S Desktop / Wall-mount Subset Mechanical Construction.................................... Black ABS housing with aluminum front panel Connections............................................. DB25 connection to remote amplifier Dimensions (overall)..................... 8.94 H x 7.6 W x 4.56 D inches (227.1 x 193 x 115.8 mm) Temperature range......................................... -22 F to +158 F (-30 C to +70 C) Relative Humidity....................................................... 95%, non-condensing Approvals Electical Safety....................................... Complies with IEC 60950 and UL 60950 CE Mark.................................... Complies with Low Voltage Directive 73/23/EEC, and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC Desktop / Wall-mounted Subset SP2 Part Numbers*: SP2 Series Mounting Party Lines Station Type Operation Handset Approval Finish Options Entries 8 4 5 0 0 8 X 3 X 0 UL Safety CE R B No Options 0 Trop TR A * Items marked as X are configurable. Not all option combinations are possible please contact GAI-Tronics for assistance.

Technical Data - SP2 Series Specifications Indoor Remote-mounted Subset Stations - cont. Flush-mount and Deskedge Subsets Mechanical Construction........................................................ 16 gauge cold-rolled steel Finish........................................................... Safety orange powder coating Connections............................................. DB25 connection to remote amplifier Dimensions (overall) Flush-mount........................... 6 H x 6 W x 5.61 D inches (152.4 x 152.4 x 142.5 mm) Desk-edge................................ 5 H x 3.19 W x 7.01 D inches (127 x 81 x 178 mm) Temperature range......................................... -22 F to +140 F (-30 C to +60 C) Relative Humidity....................................................... 95%, non-condensing Approvals Electical Safety....................................... Complies with IEC 60950 and UL 60950 CE Mark.................................... Complies with Low Voltage Directive 73/23/EEC, and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC Flush-mount and Deskedge Subsets SP2 Part Numbers*: SP2 Series Mounting 5-Party Lines Subset Subset Handset Approval Finish Options Entries 8 X 5 0 0 X X X X 0 Flush-mount 5 Desk-edge 6 6 PVC 1 15 PVC 2 25 PVC 3 6 Hytrel 4 15 Hytrel 5 25 Hytrel 6 UL Safety CE R B Orange 1 Gray 2 No Options 0 Trop TR A Explosionproof Wall-mount Stations Explosion-proof Wall-mount SP2 Part Numbers*: SP2 Series Mechanical Construction.......................................... Cast aluminum with gray epoxy coating Connections................................................ Screw-type barrier terminal blocks Dimensions (overall).............. 14.31 H x 13.06 W x 11.68 D inches (363.6 x 331.8 x 296.6 mm) Temperature range........................................... -4 F to +140 F (-20 C to +60 C) Relative Humidity....................................................... 95%, non-condensing Environmental Rating........................................................... Type 4X (IP66) Approvals Electical Safety....................................... Complies with IEC 60950 and UL 60950 CE Mark.................................... Complies with Low Voltage Directive 73/23/EEC, and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC NRTL (Listed USA and Canada)................ Hazardous locations, Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups F, G, Class III, Div. 1, T6 ATEX/IECEx Certified.................................................. II 2 G Ex d [ib] IIB + H2 T6 Outdoor Party Station Connection / Wall-mount Lines Type Control Handset Approval Gray Epoxy Finish Options Entries 9 2 X X X X X 5 X X Amp Only 0 Multi Party 5 AC Handset/Speaker 1 AC Speaker 3 Note: *Fiber optic stations require a suitable SFP module. Contact GAI-Tronics for more information. Ethernet with RTU 2 Ethernet with ALT Page and RTU 4 Ethernet with All Call and RTU 6 Fiber with RTU* B Fiber with Alt* Page and RTU D Fiber with All* Call and RTU F Amp Only 0 6 PVC 1 15 PVC 2 25 PVC 3 6 Hytrel 4 15 Hytrel 5 25 Hytrel 6 UL CI D1 C ATEX Zone 1 E IEC Zone 1 G No Options 0 Trop TR A UL 1 2x1.5NPT 2x0.75NPT ATEX/IEC 2 2xM40 2xM20 * Items marked as X are configurable. Not all option combinations are possible please contact GAI-Tronics for assistance.

Technical Data - SP2 Series Specifications Weatherproof Wall-mount Stations Mechanical Construction............................................... Engineered glass-reinforced plastic Connections................................................ Screw-type barrier terminal blocks Dimensions (overall)....................... 14.6 H x 10.9 W x 10.5 D inches (371 x 276 x 267 mm) Temperature range......................................... -22 F to +140 F (-30 C to +60 C) Relative Humidity....................................................... 95%, non-condensing Environmental Rating........................................................... Type 4X (IP66) Approvals Electical Safety....................................... Complies with IEC 60950 and UL 60950 CE Mark.................................... Complies with Low Voltage Directive 73/23/EEC, and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC NRTL Listed............................ Hazardous locations, Class I, Div. 2, (USA and Canada) Groups A, B, C, D Weatherproof Wall-mount Station SP2 Part Numbers*: SP2 Series Outdoor Wall-mount Party Lines Station Type Connection / Control Handset Approval Finish Options Entries 9 2 X X X X X X X 0 Amp Only 0 Multi Party 5 AC Handset/Speaker 1 AC Handset/Speaker/Aux 2 AC Speaker 3 Note: *Fiber optic stations require a suitable SFP module. Contact GAI-Tronics for more information. Ethernet with RTU 2 Ethernet with ALT Page and RTU 4 Ethernet with All Call and RTU 6 Fiber with RTU* B Fiber with Alt Page and RTU* D Fiber with All Call and RTU* F Amp Only 0 6 PVC 1 15 PVC 2 25 PVC 3 6 Hytrel 4 15 Hytrel 5 25 Hytrel 6 CE UL CI D2 B S Orange 1 Gray 2 No Options 0 Trop TR A Spring Kit SK B Vee Notch VN C Lock Door LD D LD, SK E LD, VN F LD, TR G SK, VN H SK, TR J VN, TR K LD, SK, VN L LD, SK, TR M LD, VN, TR N LD, SK, VN, TR P * Items marked as X are configurable. Not all option combinations are possible please contact GAI-Tronics for assistance.

Technical Data - SP2 Series Specifications Accessories Acoustic Hood - 9/14dB 6866-001 Yellow hood 9dB 6866-002 Gray hood 9dB 6866-003 Yellow hood 14dB 6866-004 Gray hood 14dB Acoustic Hood - 23dB 988-60-0002-701 Yellow hood 988-60-0002-702 Red hood 988-60-0002-703 Orange hood 988-60-0002-704 Blue hood Headset / Extension Cable 10401-201 Headset/Microphone 10416-103 30 Extension cable with push-to-page switch 10416-104 50 Extension cable with push-to-page switch 10416-105 8 Extension cable with push-to-page switch Subset Extension Cable 12587-101 25 Subset extension cable with fitted connectors. 12587-102 25 Subset extension cable with fitted connectors and wall plate. 12587-104 15 Subset extension cable with one fitted and one loose connector.

Contact your sales representative or call our toll-free sales hotline for further information at 1-800-492-1212. Look to GAI-Tronics, a leader in the emergency notification industry through its innovative products, uncompromising quality and advanced technology. Visit us @ GAI-TRONICS Quality Management System Certified by DNV-GL - ISO 9001:2008. The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice. Pub. 160303 Rev 4/2017