of the numerical value of 54Hex ASCII is that 54 consists of 5 (35Hex) and 4(34 Hex).

Similar documents
1. Communication Data Frame

INVERTER E510. Communication Addendum. ModbusRTU/ASCI. DOCUMENT-TECO-E510-AC001 Ver01:

Modbus Protocol For FTS/FTM 3x&8x

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system

Tongta Inverter TDS-F8

1. Introduction. 2. Installation MODBUS INTERFACE

Automatic transfer switch

MODBUS Protocol Version

Manual 09/11 MN Z-EN. NZM-XATS-C Automatic Transfer Switch-Controller Modbus Communication Protocol

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 3

JCL-33A (C5) Warning. 1. System Configuration COMMUNICATION INSTRUCTION MANUAL

DC1010 DC1020 DC1030 DC1040

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 1

Optidrive Applications Support Library

INTELLIS. Modbus Direct Network Monitor

Optidrive Applications Support Library

EM24-DIN PFA, PFB & X models

The benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Section 0.0 Warnings... 2 Section 1.0 Quick Set-up... 3 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

Section 0.0 Warnings... 3 Section 1.0 Quick Set-up... 4 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

BINARY SYSTEM. Binary system is used in digital systems because it is:

FY100 FY101 FY400 FY600 FY700 FY800 FY900 FA200 FA211 TAIE COMMUNICATION MANUAL DIGITAL PID CONTROLLER. March, 2009 FY_COMM_EN_V1.

Phone: Fax: Web:

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

PFC96Evo / PFC144Evo CONTROLLER MODBUS PROTOCOL

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

Elotech Standard Protocol. for Single R8200 SC

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU. 1SFC132092M0201 June SFC132092M0201 1

S-Series Sensor ASCII Protocol v8.1.0

COMMUNICATION INSTRUCTION MANUAL Temperature Controller KT4R

RS-232 Serial Communication Control

EM21 COMMUNICATION PROTOCOL. Version 1 Revision 0

Positional Number System

4511 MODBUS RTU. Configuration Manual. Solenoid / alarm driver. No. 9203MCM100(1328)

Series Temperature Controller Instruction Sheet

Golander Peristaltic Pump MODBUS Communication Instruction

TOSVERT VF-S15 Series RS485 Communication Function Instruction Manual

EM300 Series. ET300 Series

EM270 COMMUNICATION PROTOCOL. Version 1 Revision 0

MCF. User's Manual. Air Flowmeter NPT Model. for Communication Functions. No. CP-SP-1301E

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

for more: efesotomasyon - sanch inverter S2000 is RS-232C built-in. It is available for RS-485 when WI-K2 interface card is added.

INSTRUCTION MANUAL FOR JU THYRISTOR REGULATOR COMMUNICATIONS INTERFACE

MODBUS Protocol for MiCOM P30 Series

Input-Output Organization

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

Modbus Communication Manual V7 and V74X Drives

[ 公司地址 ] Modbus Protocol. For THS/THM 30X&80X_Temp.&Humididy & THS8X/THM8X_Dew Point Series V7.0

1. System Configuration

1. System configuration

GPD 515/G5 Modbus RTU Technical Manual

Data Representation and Binary Arithmetic. Lecture 2

Modbus Remote Communication Protocol for REM 54_. Technical Description

mifare ID Reader with Selectable Outputs Data Sheet

Communications Interface (RS-485) Instruction Manual

EM271 COMMUNICATION PROTOCOL. Version 0 Revision 0

Product Family: GS Drives Number: AN-GS-006

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 0

RSGD 75mm Modbus Protocol

TOSVERT VF-S9 Communications Function Instruction Manual

TOSVERT VF-AS1 Series RS485 Communication Function Instruction Manual

Serial I/O. 4: Serial I/O. CET360 Microprocessor Engineering. J. Sumey

TOSVERT VF-nC1 Communications Function Instruction Manual

Controller Communication. Series. Digital

UNIT 7A Data Representation: Numbers and Text. Digital Data

Motors I Automation I Energy I Transmission & Distribution I Coatings. Modbus RTU CFW500. User s Manual

EM26-96 COMMUNICATION PROTOCOL. Version 1 Revision 0

Modbus RTU CFW100. User s Manual. Phone: Fax: Web: -

SENTRY HPS / HTS COMMUNICATION PROTOCOL

Aceprox FSK Proximity Reader REV2 Data Sheet

4. Setting parameters

Modbus Protocol For TGP03 / THP03

Temperature Controller SA100. Communication Instruction Manual IMR01J02-E2 RKC INSTRUMENT INC.

1. System Configuration

DTU sensor data formats.

THERMOSALD ISX RS485 MODBUS (V5) 3E S.r.l. - Via del Maccabreccia 37/a LIPPO DI CALDERARA (BOLOGNA) THERMOREGULATOR for PULSE WELDING

LD6015. Datasheet & Manual. 1. Features. 3. Description. 2. Applications. 4. Absolute maximum ratings* 5. Recommended operating conditions

plc numbers Encoded values; BCD and ASCII Error detection; parity, gray code and checksums

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

Programming (1.0hour)

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface

Input Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user

EM100 Series and ET100 Series

COMMUNICATIONS INTERFACES

Motors I Automation I Energy I Transmission & Distribution I Coatings. Modbus RTU CFW300. User s Manual

4511 MODBUS RTU. Configuration Manual. Pulse isolator. No. 9202MCM101(1707) For 4511 devices from ser. no:

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Modbus Protocol For PMX / PXM3X

T7 Modbus Communication User Guide

Modbus parameter specifi cations for emb Standard Series

FLUIDWELL GENERAL MODBUS COMMUNICATION PROTOCOL

EM24_E1. (Ethernet) COMMUNICATION PROTOCOL. Version 0 Revision 1.2

EE 109 Unit 3. Analog vs. Digital. Analog vs. Digital. Binary Representation Systems ANALOG VS. DIGITAL

LMV2 / LMV3... Modbus. User Documentation. Building Technologies Division

D I G I M A X BINARY COMMUNICATIONS PROTOCOL SYSTEM COMMAND AND CONTROL LANGUAGE APPLICATION MANUAL. Revision B1 April 30, 1993

Transcription:

of the numerical value of 54Hex ASCII is that 54 consists of 5 (35Hex) and 4(34 Hex).

1. Definition of coding Communication agreement belongs to hexadecimal system, of which each character represents the following information. Character 0 1 2 3 4 5 6 7 ASCII code 30H 31H 32H 33H 34H 35A 36A 37A Character 8 9 A B C D E F ASCII code 38A 39H 41H 42H 43A 44A 45H 46H 2. Character structure 10 Bit character box (For ASCII) Data pattern: 8N1 For ASCII Start bit 0 1 2 3 4 5 6 7 Stop bit 10-bits Character box 10 Bit character box (For RTU) Data pattern: 8N1 For RTU Start bit 0 1 2 3 4 5 6 7 Stop bit 10-bits Character box Data pattern: 8O1 For ASCII Start bit 0 1 2 3 4 5 6 7 Odd parity Stop bit 11-bits Character box

Data pattern: 8E1 For ASCII Start bit 0 1 2 3 4 5 6 7 ever parity Stop bit Data pattern: 8O1 For RTU 11-bits Character box Start bit 0 1 2 3 4 5 6 7 Odd parity Stop bit 11-bits Character box Data pattern: 8E1 For RTU Start bit 0 1 2 3 4 5 6 7 ever parity Stop bit 11-bits Character box 3. Structure of communication data Data format box ASCII mode: STX Hi Lo Hi Lo DATA (n-1) DATA 0 Start character = : (3AH) Communication address: 8-bit address consists of 2 ASCII codes code: 8-bit function code consists of 2 ASCII codes Data characters: n 8-bit data content consists of 2n ASCII codes n 16, with the maximum of 32 ASCII codes

LRC CHK Hi LRC CHK Lo END Hi END Lo LRC Check: 8-bit LRC Check consists of 2 ASCII codes End character: END Hi = CR (0DH), END Lo = LF (0AH) RTU mode: START DATA (n-1) DATA 0 CRC CHK Low CRC CHK High END Keep that zero-input signal is more than or equal to 10 ms Communication address: 8-bit binary address code: 8-bit binary address Data characters: n 8-bit data, n = 16 CRC Check: 16-bit CRC Check consists of 2 8-bit binary systems Keep that zero-input signal is more than or equal to 10 ms Communication 00H: All driver Broadcasts : For inverter with 01st address 0FH: For inverter with 15th address 10H: For inverter with 16th address, by analogy, the maximum could reach 240. code and Data Characters 03H: Read out the content of temporary storage 06H: Write a WORD into temporary storage; code 03H: Read out the content of temporary storage. For example: Driver address, reads out the data characters in 2 successive temporary storages as follows: Initial temporary storage address 2102H code 06H: Write a WORD into temporary storage.

Format of enquiry message character string: STX : Starting address Number of data (count by word) LRC Check END 3 2 2 2 D CR LF Format of response message character string: STX : Number of data (count by byte) Content of starting address 2102H Content of address 2103 H LRC Check END 3 4 CR LF ASCII mode: RTU mode: Format of enquiry message: Starting data address Number of data (count by word) CRC CHK Low CRC CHK High 03H 21H 02H 00H 02H 6FH F7H Format of response message: Number of data (count by byte) Content of data address 8102H Content of data address 8103H CRC CHK Low CRC CHK High 03H 04H 17H 70H 00H 00H FEH 5CH

For example: Driver address, writes 6000 (1770H) into the internal setting parameter 0100H of driver. LRC Check of ASCII mode ASCII mode: Format of enquiry message character string: STX : Data address Data content LRC Check END 6 CR LF Format of response message character string: STX : Data address Data content LRC Check END 6 CR LF RTU mode: Format of enquiry message: Data address Data content CRC CHK Low CRC CHK High 06H 00H 17H 70H 86H 22H Format of response message: 06H Data address 00H 17H Data content 70H CRC CHK Low 86H CRC CHK High 22H

LRC Check is the value added from to Data Content. For example, the LRC Check of the above 3.3.1 enquiry message is as: + 03H + 21H + 02H + 00H + 02H = 29H, then the complement of 2 (D7H) is taken. CRC Check of RTU mode CRC Check is from to Data content, and its running rule is as follows: Step 1: Make 16-bit temporary storage (CRC temporary storage) = FFFFH. Step 2: Exclusive OR first 8-bit byte message instruction and low 16-bit CRC temporary storage: Perform Exclusive OR, and store the result into CRC temporary storage. Step3: Move CRC temporary storage one more bit, and fill 0 into high bit position. Step 4: Check right shift value, if being 0, store the new value for step 3 into CRC temporary storage, otherwise in case of Exclusive OR A0 and CRC temporary storage, store the result into CRC temporary. Step 5: Repeat Step 3 ~ Step 4, and operate completely for 8-bit. Step 6: Repeat Step 2 ~ Step 5, and take the message instruction for next 8-bit, till all message instructions are operated completely. Finally, the value gotten of CRC temporary storage is CRC Check. It is noteworthy that, CRC Check must be placed into the check mode of message instruction interchangeably. The following is the example of CRC Check running written in C language: Unsigned char * data //Message instruction pointer Unsigned char length //Length of message instruction

unsigned int crc_chk (unsigned char*data, unsigned char length) { int j; unsigned int reg_crc=oxffff; while( 1ength--) { reg_crc^=*data ; for (j = 0; j<8; j ) { if (reg_crc & Ox01) { /*LSB (b0) =1 */ reg_ere= (reg_crc>>1) ^OXa001; }else{ reg_cre=reg_crc>>1; } } retum reg_crc; //Finally feedback the value of CRC temporary storage } 7-9 Advanced application parameters P800 Advanced application parameter lock Initial value: 1 Setting range 0 1 Unit 1 content 0: Lock 1: Unlock If P800 is set to 0,you can not use the advanced parameters. P801 System 50Hz/60Hz selection Initial value: 0 Setting range 0 1 Unit 1 content 0: 50Hz 1: 60Hz 50Hz/60Hz system could be set via the parameter according the condition of electric network. P802 constant and variable torque selection Initial value : 0 Setting range 0 1 Unit 1 content 0: Constant torque 1: Variable torque

For fan and pump load, you can select variable torque for better energy saving. P803 Overvoltage protection setting Initial value: change Setting range 760 820 Unit 1 P803 sets DC-bus overvoltage protection level. This function could be used to avoid over voltage protection during deceleration. P804 Undervoltage protection setting Initial value: change Setting range 380 450 Unit 1 P804 sets voltage protection level. If the input voltage is low, inverter is easy to trip for undervoltage. This function could be used to avoid inverter protection undervoltage. P805 Over temperature protection setting Initial value: change Setting range 40 120 Unit 1 P805 sets the over temperature protection level of inverter. In high temperature environment, the protection level could be improved appropriately, to guarantee the normal running of inverter. However, too high setting value will result in IGBT damage, so the only solution is to improve the effect of heat elimination, so as to achieve the goal of cooling-down. P806 Current display filter time Initial value: 2.0 Setting range 0 100 Unit 1 This parameter setting is relevant to the stabilization of current display, and shall not be modified in general. If the setting is too small, current display will fluctuate. P807 0-10V analogue output low end calibration coefficient Initial value: * Setting range 0 65535 Unit 1

P808 0-10V analog output high end calibration coefficient Initial value : * Setting range 0 65535 Unit 1 P809 0-20mA analogue output low end calibration coefficient Initial value: * Setting range 0 65535 Unit 1 P810 0-20mA analog output high end calibration coefficient Initial value: * Setting range 0 65535 Unit 1 The above parameters are factory default setting, normally shall not be adjusted, otherwise it may cause abnormal operation.