Certification Document Supermicro SSG-6027R-E1R12T 04/30/2014. Supermicro SSG-6027R-E1R12T system

Similar documents
Certification Document GRAFENTHAL GmbH R2208 S2 01/04/2016. GRAFENTHAL GmbH R2208 S2 Storage system

Certification Document Starline NASdeluxe NDL-4224R/L 06/24/2015. Starline Computer GmbH NASdeluxe NDL-4224R/L Storage system

Certification Document macle GmbH IBM System xx3650 M4 03/06/2014. macle GmbH IBM System x3650 M4

Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014. Rackserver Open-E Unified Storage 15 TB O2212iR system

Certification Document HP Proliant DL380 G7 12/22/2011. HP Proliant DL380 G7 storage system

HA Certification Document Broadberry CyberStore 424S 05/17/2013. Open-E High Availability Certification report for Broadberry CyberStore 424S

HA Certification Document Dell PowerEdge R720 07/24/2013. Open-E High Availability Certification report for Dell PowerEdge R720

HA Certification Document Happyware HW-OPE2123-R1 07/04/2013. Open-E High Availability Certification report for Happyware HW-OPE2123-R1

HA Certification Document TAROX ParX R208s G5 03/26/2014. Open-E High Availability Certification report for TAROX ParX R208s G5

Open-E High Availability Certification report for Intel Server System R2224GZ4GC4

Lenovo RD240 storage system

Intel SR2612UR storage system

Q500-P20 performance report

ReadyNAS OS 6 Desktop & Rackmount Performance

Technical Presales Guidance for Partners

10/08/2010 Please see the part number system chart on page 8 for all red X, Y, R and Z s. Page1

HyperScalers JetStor appliance with Raidix storage software

Cisco CDE465 DIMM Reseating and Replacement Procedure. Modification History

Assessing performance in HP LeftHand SANs

StorPool System Requirements

SSG-6028R-E1CR16T SSG-6028R-E1CR24N/L SSG-2028R-E1CR48N/L SSG-6048R-E1CR60N/L

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

What is QES 2.1? Agenda. Supported Model. Live demo

High Performance Computing

2018 QSAN XCubeNAS. XN8016R / XN8024R Introduction

VX1800 Series Unified Network Storage

10Gb iscsi Initiators

Notes Section Notes for Workload. Configuration Section Configuration

TECHNICAL REFERENCE. XTAccess High Performance 3U Hardware Manual / TR-XTA3-2500B

JetStor White Paper SSD Caching

Pioneer DreamMicro. Rackmount 2U Server S87 Series

eslim SV Xeon 2U Server

STOR-LX. Features. Linux-Based Unified Storage Appliance

Design Concepts & Capacity Expansions of QNAP RAID 50/60

Sun Lustre Storage System Simplifying and Accelerating Lustre Deployments

EMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Vess A2000 Series. NVR Storage Appliance. Milestone Surveillance Solution. Version PROMISE Technology, Inc. All Rights Reserved.

NEC Express5800/R120e-2E Configuration Guide

High-speed rackmount NAS for SMBs with two 10GbE SFP+ ports & one PCIe slot for expansion

PREEvision System Requirements. Version 8.5 English

No More Waiting Around

Cisco Connected Safety and Security UCS C220

VX3000-E Unified Network Storage

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

All product specifications are subject to change without notice.

NEC Express5800/B120f-h System Configuration Guide

SurFS Product Description

System Requirements. PREEvision. System requirements and deployment scenarios Version 7.0 English

Cloudian Sizing and Architecture Guidelines

eslim SV Opteron 1U Server

Anil Vasudeva IMEX Research. (408)

PREEvision System Requirements. Version 9.0 English

eslim SV Xeon 1U Server

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary

Milestone Solution Partner IT Infrastructure Components Certification Report

Model Configurations. Contains: Hardware RAID with JBOD Expansion. HBA Mode with JBOD Expansion. JBOD Expansion

Avid Configuration Guidelines Dell T7600 Dual Six-Core / Dual Eight-Core CPU Workstation Media Composer 6.x Symphony 6.x NewsCutter 10.

Pioneer DreamMicro. Rackmount 1U Server - S58 Series

Acer AR320 F1 specifications

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120f-1M System Configuration Guide

NEC Express5800/B120e-h System Configuration Guide

Avid Configuration Guidelines HP Z820 Dual Six-Core / Dual Eight-Core CPU Workstation

Hardware & System Requirements

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage

Semantic Publishing Benchmark Full Disclosure Report Irini Fundulaki 24/04/2015

SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U

Streamlined feature-rich ATX UP serverboard. The most scalable I/O expandability

PREEvision. System Requirements. Version 7.5 English

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

iscsi STORAGE ARRAYS: AND DATABASE PERFORMANCE

Storage Adapter Testing Report

Avid Configuration Guidelines Dell T5610 Dual 6-Core, Dual 8-Core & Dual 12-Core CPU Media Composer Symphony NewsCutter 10.5.

IOPStor: Storage Made Easy. Key Business Features. Key Business Solutions. IOPStor IOP5BI50T Network Attached Storage (NAS) Page 1 of 5

Pioneer DreamMicro. Rackmount 1U Server - S48 Series

Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays

A step up from TS-831X

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP

System Requirements. PREEvision. System requirements and deployment scenarios Version 7.0 English

STOR-LX2. Features. Linux-Based Unified Storage Appliance

Avid Configuration Guidelines Dell Precision T Core, CPU Workstation Media Composer Symphony NewsCutter 10.5.

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Extreme I/O Expandability with High VR Power Efficiency

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

NEC Express5800/B110d Configuration Guide

Vess A2000 Series. NVR Storage Appliance. SeeTec Surveillance Solution. Version PROMISE Technology, Inc. All Rights Reserved.

STORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp

Backup Solutions with (DSS) July 2009

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

NEC Express5800/R120h-2E System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120h-1M System Configuration Guide

ThinkServer RD630 Photography - 3.5" Disk Bay*

should be able to scale to additional pair controllers with 128 GB Cache across Controllers." replacement. With memory of >= 64 GB

Backup Appliances. Geir Aasarmoen og Kåre Juvkam

Evaluation of the Chelsio T580-CR iscsi Offload adapter

Page 1 of 18 Dave Pimm Avid Technology Dec 6th, 2013 Rev B

Windows NAS Delivering Seamless Integration with All Windows Computers and Servers. Windows Storage Server

Transcription:

Supermicro SSG-6027R-E1R12T system

Executive summary After performing all tests, the Supermicro SSG-6027R-E1R12T has been officially certified according to the Open-E Hardware Certification Program Guide 2.1. During the tests, it was found that the system is functional and efficient. With the Open-E DSS V7 operating system installed, the Supermicro SSG-6027R-E1R12T is stable and performs well. In general, the system can be used for many different applications, but the following are recommended: iscsi storage The following features make Supermicro SSG-6027R-E1R12T good iscsi storage: Hardware RAID5, RAID6, RAID50 or RAID60 for high performance and data safety. Two 10GbE interfaces for fast MPIO connection and flexible network topology. Redundant power supply for system reliability. NAS filer The following features make Supermicro SSG-6027R-E1R12T a great NAS filer solution: Twelve high capacity SATA hard drives provide a lot of space for user files. Hardware RAID5, RAID6, RAID50 or RAID60 for fault tolerance and the most efficient use of available disk space or RAID10 for increased IOps. Two 10GbE interfaces for independent connection to different networks or link aggregation for improved throughput. Storage for backup For this application the following can be used: Two 10GbE network interfaces provides enough throughput for demanding backup networks. Redundant power supply for system reliability. Twelve high capacity SATA hard drives and RAID50 or RAID60, ensures a lot of safe storage space for backups. Certification notes For link aggregation, it is recommended to use balance-alb or 802.3ad bonding mode. 2

Supermicro SSG-6027R-E1R12T hardware components... 4 Supermicro SSG-6027R-E1R12T photos... 5 Auxiliary systems hardware components... 6 Administration functionality... 7 Network functionality... 8 Network test topology... 8 802.3ad bonding mode test... 9 Balance-alb bonding mode test... 10 Balance-rr bonding mode test... 11 Single NIC performance test... 12 RAID functionality... 13 RAID test topology... 13 Hardware RAID0 test... 14 Hardware RAID1 test... 15 Hardware RAID5 test... 16 Hardware RAID6 test... 17 Hardware RAID10 test... 18 Hardware RAID50 test... 19 Hardware RAID60 test... 20 NAS functionality... 21 NAS test topology... 21 SMB test... 22 iscsi functionality... 23 iscsi Initiator test topology... 23 iscsi Target test topology... 23 iscsi Initiator test... 24 iscsi Target test... 25 3

Supermicro SSG-6027R-E1R12T hardware components Technical specifications about the certified system are listed below: Model Supermicro SSG-6027R-E1R12T Operating system Open-E DSS V7 build 10529 Enclosure/chassis Supermicro CSE-826BE16-R920LPB CPU Intel Xeon Processor E5-2697 v2 2.70GHz Motherboard Supermicro MBD-X9DRH-7TF Memory 8x 8GB Samsung DDR3 ECC-REG M393B1K70CH0-CH9 Network Intel Ethernet Controller X540-AT2 HW RAID LSI SAS 2208 6Gb/s SAS Raid-on-Chip Hard disk drives 12x 3TB TOSHIBA MG03SCA300 TABLE 1: Hardware components list of Certified System with Open-E DSS V7 4

Supermicro SSG-6027R-E1R12T photos FIGURE 1: Front photo FIGURE 2: Rear photo FIGURE 3: Top photo 5

Auxiliary systems hardware components Auxiliary systems with MS Windows or Open-E DSS V7 installed, used in Open-E Hardware Certification Process. Model Operating system Enclosure/chassis Motherboard CPU Memory Network Network Hard disk drives Custom MS Windows Server 2012 R2 Supermicro CSE-827HQ-R1400B Supermicro MBD-X8DTT-HIBQF+-B 2x Intel Xeon Processor L5520 2.26GHz 2x 8GB Samsung DDR3 ECC-REG M393B1K70CH0-CH9 Intel 82574L Gigabit Ethernet Controller Intel Ethernet Controller X540-AT2 500GB Seagate ES ST500NM001 TABLE 2: Hardware components of first Workstation with MS Windows Model Operating system Enclosure/chassis Motherboard CPU Memory Network Network Hard disk drives Custom MS Windows Server 2012 R2 Supermicro CSE-827HQ-R1400B Supermicro MBD-X8DTT-HIBQF+-B 2x Intel Xeon Processor L5520 2.26GHz 2x 8GB Samsung DDR3 ECC-REG M393B1K70CH0-CH9 Intel 82574L Gigabit Ethernet Controller Intel Ethernet Controller X540-AT2 500GB Seagate ES ST500NM001 TABLE 3: Hardware components of second Workstation with MS Windows Model Custom Operating system Open-E DSS V7 build 10529 Enclosure/chassis Supermicro CSE-826BE16-R920LPB CPU Intel Xeon Processor E5-2697 v2 2.70GHz Motherboard Supermicro MBD-X9DRH-7TF Memory 8x 8GB Samsung DDR3 ECC-REG M393B1K70CH0-CH9 Network Intel Ethernet Controller X540-AT2 HW RAID LSI SAS 2208 6Gb/s SAS Raid-on-Chip Hard disk drives 12x 3TB TOSHIBA MG03SCA300 TABLE 4: Hardware components of Workstation with Open-E DSS V7 6

Model Description Supermicro SSE-X3348TR 48-ports 10GbE switch TABLE 5: Network switch details for 10 GbE connections Administration functionality The following functionality has been tested. Drive identifier Power button Front and rear LEDs OK OK OK TABLE 6: Administration functionality test 7

Network functionality Tests performed in this section check the functionality, performance and stability of the network solutions available in the Open-E DSS V7 product on the certified system. The tests rely on configuring the iscsi targets and copying the data from many Workstations with MS Windows through various network connections with big block size using appropriate testing tools. Network test topology Network topology for Network testing is shown below. FIGURE 4: Network topology for Network testing 8

802.3 ad bonding mode test The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through an 802.3ad bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test for 802.3ad bonding mode test performed on Intel Ethernet Controller X540-AT2 802.3ad bonding mode performance test NIC model Workstations with MS Windows Intel Ethernet Controller X540-AT2 1 st Workstation 695 737 passed 2 nd Workstation 734 784 passed TABLE 7: 802.3ad bonding mode performance test table for Intel Ethernet Controller X540-AT2 1st Workstation 2nd Workstation FIGURE 5: 802.3ad bonding mode performance test chart for Intel Ethernet Controller X540-AT2 9

Balance-alb bonding mode test The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-alb bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test for Balance-alb bonding mode test performed on Intel Ethernet Controller X540-AT2 Balance-alb bonding mode performance test NIC model Workstations with MS Windows Intel Ethernet Controller X540-AT2 1 st Workstation 554 750 passed 2 nd Workstation 783 771 passed TABLE 8: Balance-alb bonding mode performance test table for Intel Ethernet Controller X540-AT2 1st Workstation 2nd Workstation FIGURE 6: Balance-alb bonding mode performance test chart for Intel Ethernet Controller X540-AT2 10

Balance-rr bonding mode test The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-rr bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test for Balance-rr bonding mode test performed on Intel Ethernet Controller X540-AT2 Balance-rr bonding mode performance test NIC model Workstations with MS Windows Intel Ethernet Controller X540-AT2 1 st Workstation 739 244 passed 2 nd Workstation 729 249 passed TABLE 9: Balance-rr bonding mode performance test table for Intel Ethernet Controller X540-AT2 1st Workstation 2nd Workstation FIGURE 7: Balance-rr bonding mode performance test chart for Intel Ethernet Controller X540-AT2 11

Single NIC performance test The test relies on configuring the iscsi targets and copying the data from Workstations with MS Windows through single NIC with a 4MB block size using the Iometer testing tool. 2. Test for single NIC test performed on Intel Ethernet Controller X540-AT2 Single NIC performance test NIC model Workstations with MS Windows Intel Ethernet Controller X540-AT2 1 st Workstation 463 238 passed TABLE 10: Single NIC performance test table for Intel Ethernet Controller X540-AT2 1st Workstation FIGURE 8: Single NIC performance test chart for Intel Ethernet Controller X540-AT2 12

RAID functionality Tests performed in this section check the functionality, performance and stability of Open-E DSS V7 storage devices on the certified system. Tests in this section rely on the creation of the RAID units on 0, 1, 5, 6, 10, 50 and 60 levels, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. RAID test topology Network test topology for RAID testing is shown below FIGURE 9: Network test topology for RAID testing 13

Hardware RAID0 test The test relies on creation of the RAID0 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID0 and Intel Ethernet Controller X540-AT2 RAID0 performance test Block size [KB] 4 43 62 passed 32 288 470 passed 64 325 517 passed 128 398 753 passed 256 530 879 passed 512 508 842 passed 1024 540 997 passed 4096 541 1101 passed TABLE 11: RAID0 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 10: RAID0 performance test chart for Intel Ethernet Controller X540-AT2 14

Hardware RAID1 test 3. Test description The test relies on creation of the RAID1 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 4. Test for RAID1 and Intel Ethernet Controller X540-AT2 RAID1 performance test Block size [KB] 4 42 61 passed 32 284 408 passed 64 386 388 passed 128 488 502 passed 256 585 692 passed 512 641 415 passed 1024 647 411 passed 4096 555 416 passed TABLE 12: RAID1 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 11: RAID1 performance test chart for Intel Ethernet Controller X540-AT2 15

Hardware RAID5 test The test relies on creation of the RAID5 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID5 and Intel Ethernet Controller X540-AT2 RAID5 performance test Block size [KB] 4 40 56 passed 32 265 504 passed 64 365 746 passed 128 471 854 passed 256 592 1101 passed 512 620 1116 passed 1024 623 1104 passed 4096 636 1032 passed TABLE 13: RAID5 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 12: RAID5 performance test chart for Intel Ethernet Controller X540-AT2 16

Hardware RAID6 test The test relies on creation of the RAID6 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID6 and Intel Ethernet Controller X540-AT2 RAID6 performance test Block size [KB] 4 43 57 passed 32 284 466 passed 64 381 663 passed 128 469 854 passed 256 669 1050 passed 512 606 1113 passed 1024 604 1109 passed 4096 616 1098 passed TABLE 14: RAID6 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 13: RAID6 performance test chart for Intel Ethernet Controller X540-AT2 17

Hardware RAID10 test The test relies on creation of the RAID10 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID10 and Intel Ethernet Controller X540-AT2 RAID10 performance test Block size [KB] 4 44 62 passed 32 289 366 passed 64 378 414 passed 128 478 507 passed 256 550 686 passed 512 601 1057 passed 1024 627 1043 passed 4096 608 1010 passed TABLE 15: RAID10 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 14: RAID10 performance test chart for Intel Ethernet Controller X540-AT2 18

Hardware RAID50 test The test relies on creation of the RAID50 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID50 and Intel Ethernet Controller X540-AT2 RAID50 performance test Block size [KB] 4 41 58 passed 32 281 450 passed 64 377 694 passed 128 486 631 passed 256 562 869 passed 512 593 1058 passed 1024 648 830 passed 4096 601 857 passed TABLE 16: RAID50 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 15: RAID50 performance test chart for Intel Ethernet Controller X540-AT2 19

Hardware RAID60 test The test relies on creation of the RAID60 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID60 and Intel Ethernet Controller X540-AT2 RAID60 performance test Block size [KB] 4 42 58 passed 32 280 446 passed 64 374 646 passed 128 466 817 passed 256 593 1012 passed 512 628 1111 passed 1024 571 1104 passed 4096 577 1066 passed TABLE 17: RAID60 performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 16: RAID60 performance test chart for Intel Ethernet Controller X540-AT2 20

NAS functionality Tests performed in this section check the functionality, performance and stability of the NAS protocols in the Open-E DSS V7 product on the certified system. The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. NAS test topology Network topology for NAS testing is shown below. FIGURE 17: Network topology for NAS testing 21

SMB test The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for SMB and Intel Ethernet Controller X540-AT2 SMB performance test Block size [KB] 4 108 100 passed 32 573 571 passed 64 706 472 passed 128 1112 585 passed 256 1018 709 passed 512 1024 645 passed 1024 775 488 passed 4096 946 497 passed TABLE 18: SMB performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 18: SMB performance test chart for Intel Ethernet Controller X540-AT2 22

iscsi functionality Tests performed in this section check the functionality, performance and stability of the iscsi protocol in the Open-E DSS V7 product on the certified system. iscsi Initiator test topology Network topology for iscsi Initiator testing is shown below. FIGURE 19: Network topology for iscsi Initiator testing iscsi Target test topology Network topology for iscsi Target testing is shown below. FIGURE 20: Network topology for iscsi Target testing 23

iscsi Initiator test The test relies on using the storage connected via the built-in iscsi Initiator for NAS volumes, creating SMB shares on these NAS volumes and copying data from a Workstation with MS Windows to them with various block sizes using the Iometer testing tool. 2. Test for iscsi Initiator and Intel Ethernet Controller X540-AT2 iscsi Initiator performance test Block size [KB] 4 111 105 passed 32 539 554 passed 64 800 431 passed 128 876 581 passed 256 955 598 passed 512 807 625 passed 1024 970 544 passed 4096 1128 438 passed TABLE 19: iscsi Initiator performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 21: iscsi Initiator performance test chart for Intel Ethernet Controller X540-AT2 24

iscsi Target test The test relies on creating the iscsi target on the certified system and copying the data from a Workstation with MS Windows to it with various block sizes using the Iometer tool. 2. Test for iscsi Target and Intel Ethernet Controller X540-AT2 iscsi Target performance test Block size [KB] 4 42 60 passed 32 283 488 passed 64 382 706 passed 128 472 489 passed 256 578 640 passed 512 705 1020 passed 1024 675 559 passed 4096 617 817 passed TABLE 20: iscsi Target performance test table for Intel Ethernet Controller X540-AT2 Block size [KB] 4 32 64 128 256 512 1024 4096 FIGURE 22: iscsi Target performance test chart for Intel Ethernet Controller X540-AT2 25