PROFI-8455 PROFIBUS Remote I/O Unit

Similar documents
PROFI-5053 PROFIBUS Remote I/O Module Quick Start Guide

PROFI-8855 User Manual

GW-7553 PROFIBUS/Modbus TCP Gateway

Operator Manual for Profibus

FD67 QUICK START GUIDE PROFIBUS-DP

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

i-7550 PRIFIBUS to RS232/RS485/RS422

Operation manual. HDOM-Profibus-V0. More options please visit;

VersaMax IP Input Module

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

SMART RELAY SRW 01 V4.0X

SCHMIDT Sensor interface PROFIBUS Instructions for use

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

I-7550E PROFIBUS/Ethernet Converter. User's Manual

EL731 PROFIBUS INTERFACE

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

Copyright: December 2017 Nidec Issue: E

Additional instructions Memograph M, RSG45 Advanced Data Manager

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

PAC BI-DP BIM and 8701-CA-BI Carrier

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

T1K MODBUS Base Controller Specifications

PROFIBUS DP/CAN Gateway PCA-100. User Manual

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

PROFIBUS DP Interface Card "OPC- F1-PDP"

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Installation and Setup

Motors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual

User Manual BLCDP-2M12MT-2RFID-S

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

RMx621. Appendix to the operating manual

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

RMx621 /FML621. Appendix to the operating manual

G3 Series PROFIBUS DP Technical Manual

Product Description. Altus S. A. 1

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

CAN EGT-8 Amplifier. About:

MPCR Series Profibus-DP Technical Manual

PROFIBUS Interface WM : PD

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Bus Cover Description for Shaft Encoder

VPGate Manual PROFIBUS to serial

Pluto Gateway GATE-P1 Integration with Siemens S7

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

eloprog 485EPF.. - Vers. 1.2 eloprog Configurable safety system FIELD BUS MODULES

Profibus DP Expansion Board

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

Gateway 1400 Reference Manual

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

12.3 Fieldbus I/O Board

Connecting UniOP to Simatic S7 Profibus

Absolute Single/Multiturn Encoders. Singleturn Series 5858,5878 Multiturn Series 5868,5888

01325T -- Robot Welder

G5 Weighing Instrument

Technical Documentation

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

PROFIBUS DP Interface Option "OPC-E1-PDP"

7552 PROFIBUS/MODBUS GATEWAY. User's Manual. High Quality, Industrial Data Acquisition, and Control Products

MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

ProfiPro Distributed PROFIBUS I/O Modules User Manual

Original instructions A MEMBER OF THE ABB GROUP. PLUTO Gateway. User Manual

OPERATING INSTRUCTIONS MCD

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

2005/2012 Series Profibus DP Technical Manual

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

DVPPF02-SL PROFIBUS DP Slave Communication Module

V7 PROFIBUS-DP Option Technical Manual

MOVITRAC 31.. Frequency Inverter

User Manual for the HE693PBS106 PROFIBUS SLAVE. Second Edition 05 June 2003 MAN

CS series Mass Flow Controller Profibus Communication User s Manual Rev 1.0

PROFIBUS Technology Products

GW-7553 PROFIBUS/Modbus TCP Gateway. User's Manual

Profibus DP CFW-11. Communication Manual. Phone: Fax: Web:

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

ENCODER SERIES Pxx WITH PROFIBUS-DP INTERFACE

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

The following conventions are used to indicate precautions in this manual.

BB2 Profibus DP option

Table 1 Specifications Software Required for Configuration

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

Connecting SLC Systems as Remote I/O to PLC-5 Processors

CPU. Switch 1 Switch 2

HP8440 Power Box. The Intelligent Power Distribution Module. Installation and User Guide for PCM Version 9.02

1788HP-EN2PA-R USER MANUAL

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

Copyright 1999 by Siemens Energy & Automation, Inc. All Rights Reserved Printed in USA

SCH108BEX. Technical Manual. Scancon Encoders Huginsvej Hillerød Denmark Tlf Fax

MARTLINX INTERFACE MODULE

SBPC-21-PB FifeNet to Profibus Gateway

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

I/O Expansion Units I/O Expansion Units Overview P RS-485 I/O Expansion Unit P Modbus TCP I/O Expansion Unit P6-3-1

Transcription:

PROFI-8455 PROFIBUS Remote I/O Unit Introduction Quick Start User Guide This user guide introduces the user how to implement the PROFI-8455 into their applications in a quick and easy way. Therefore, it only provides the basic instructions. For more detail information about the PROFI-8455, please refer to the PROFI-8455 user manual in the ICP DAS product CD or download it from ICP DAS web site. PROFI-8455 Hardware Structure Status Indicator Power Input Address Console (Prog. DL.) PROFIBUS (Data Comm.) I/O Expansion Slot (Module Installation) PROFI-8455 Connector and Pin Assignment Pin No. Signal Meaning 3 B-Line Receive/Transmit data plus 5 GND Power ground of active terminator 6 VP Power 5 volt of active terminator 8 A-Line Receive/Transmit data - minus The PROFIBUS connector is a standard 9-pin D-Sub connector, there are only 4 pins used in PROFI-8455. The pins VP and GND support the 5 volt power to active terminal resistor, and the A-Line and B-Line is the data bus. PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------1

Status Indicator PROFI-8455 provide three types of status indicators, they are PWR LED (yellow), ERR LED (red) and RUN LED (green). Status Indicator Meaning Recommend solution ERR ON & PROFI-8455 is offline Check the address setting of RUN OFF with no valid baud rate PROFI-8455 and DP-master. ERR Flash (0.1 Sec) ERR Flash (0.5Sec) ERR Flash (1 Sec) ERR ON & RUN ON ERR OFF & RUN ON PWR Flash (1 Sec) (offline mode*) PROFI-8455 detects baud rate, but is still offline.(stop mode*) PROFI-8455 Prm is Fault.(Note 1) PROFI-8455 s Cfg is fault(note 2) PROFI-8455 is in clear mode*. PROFI-8455 is in operation mode*. PROFI-8455 detect module(s) offline Check the DP-Master is ready to communicate with PROFI-8455. Check the setting of PROFI-8455 in the master interface and make sure of the consistency. Same as above Sets the DP-Master from clear mode to operation mode Find the reason of the fault of corresponding module. PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------2

Terminating Resistors In order to minimize the reflection effect of the signal transmission, PROFIBUS device has to fit with an active terminal resistor at both first node and last node. The connection of active terminating resistors is shown in above circuit diagram. The PROFI-8455 doesn t have any terminating resistors inside. Therefore, users must add the terminator in external. In general, PROFIBUS connector has terminating resistors inside, and there is a switch to control the ON/OFF of the terminating resistors, as shown below. Terminator ON Terminator OFF Terminator Switch PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------3

PROFI-8455 Setting and Module Installation The following steps can help users to set and apply the PROFI-8455. 1. Load GSD file into the DP-Master Configuring software DP-Master configuring software (Siemens Step7 or ProfiCaptain etc...) loads IPDS0B0C.gsd file, and make sure of the PROFI-8455 label in I/O category. Finally, Loading PROFI-8455 into PROFIBUS at the software and activate it. 2. Select I/O modules Choose PROFI-8455 and add I/O module that you want to use. Modify the system parameter WD_On, Freeze/Sync Req., Lock/Unlock Req, Group-ID assignment, etc (modify by user s preference) 3. Set Parameter Data Wait parameterization is an important step before data exchange. In this stage, DP-Master provides the essential parameter to PROFI-8455 include user parameters and module parameters. Therefore, it must finish this setting before data exchange. 1. User Parameter: User parameter also called system parameter is the basic parameters. The number of parameter is fixed regardless of the number of modules. In PROFI-8455, there are two kinds of parameter. They are Byte Order and Diagnosis Repot Period. Byte-Order Parameter: If your system obeys the INTEL data format, you should select Little-Endian mode; otherwise, you should select Big-Endian mode. Diagnosis Report Period Parameter: This parameter dominates the time interval of each diagnostic message report. The unit of this period is millisecond. The maximum time interval is 65536 ms, the minimum is 0 ms. 2. Module Parameters: The most of modules must be initialized before applying them. Module parameters provide information about Operation Code, Data Code or Enable Diagnosis, etc Please refer to the manual to know more information about these parameters. 4. Download Setting and Program into DP-Master Users load the setting and program into DP-Master, and let it go. Users must finish these steps before starting to communicate with PROFI-8455. PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------4

5. Module Installation: In the expansion slots, users install the modules, and make sure of correct installation. Notice that address mapping is order by slot id of installed module (from left to right), and the expansion slot that without module will be skipped. 6. Address Setting: There are two hexadecimal rotary switches in PROFI-8455 panel. They dominate the address of PROFI-8455. The switch labeled LSB is represented the low nibble of the address, and the switch labeled MSB is represented the high nibble of the address. For advance setting, please refer to PROFI-8455 User s Manual. After finishing the procedure, DP-Master will establish the connection with PROFI-8455 and execute program automatically. RUN_LED indicates the status of connection that you can observe. PROFI-8455 state flow chart The state machine of PROFI-8455 is shown below. If your PROFI-8455 can t establish connection with DP-Master, you can see Q/A to solve it. PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------5

PROFI-8455 Q&A 1. Q: How do I know the status of the PROFI-8455? A: You can observe the RUN LED in PROFI-8455 panel. If RUN LED is light, data is exchanging. Otherwise it must be error in the previous state. You can see Q&A 3 to solve it. 2. Q: Have I must set the PROFI-8455 s address before power applied? A: You can change the address after power applied, but you should let the PROFI-8455 offline at least 5 second. After 5 second offline, PROFI-8455 will reset by itself, and then apply the new setting of the rotary switches. 3. Q: If PROFI-8455 couldn t establish communication with DP-Master, what can I do? A: In General, the PROFI-8455 s error is due to the following reasons. 1. Parameter Fault- PROFI-8455 s ERR LED will have an interval of 0.5 second in each flash. It may reduce from error module selection. 2, Configuration Fault-PROFI-8455 s ERR LED will have an interval of 1 second in each flash. It may reduce from error installation order. 3, DP-Master OFFLINE-PROFI-8455 s ERR LED will light until establish data exchange connection. You should switch DP-Master status from OFFLINE to OPERATE. 4, DP-Master STOP-PROFI-8455 s ERR LED will flash quickly (time interval may less then 0.5 second). You should switch DP-Master status from STOP to OPERATE. 4. Q: Which Modules is faster among the same Module Number (I-87017 and I-8017H)? A: I-8K series is faster than I-87K series. It is due to the communication interface, I-8K use Parallel interface, and I-87K use the serial communication. PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------6

5. Q: I feel that the reaction time of analog module in I-87K is slow. Why does it? A: It is due to low sampling rate. Beside the I-87017 series module, the remainder analog input module has sampling rate with 10Hz maximum. If you want to use the high sampling module, I-8017H and I-87017 is the best choice. 6. Q: how can I use the additional function of I-87082? A: Please refer to the Byte Order and Data Address chapter in the PROFI-8455 user s manual. PROFI-8455 Remote I/O Unit Quick Start User Guide (Version 1.1, January/2007) ------7