Valve and Case Expansion Monitor Specifications

Similar documents
Protection Cards for AMS 6500 Classic Systems

CSI 6500 Machinery Health Monitor Chassis Options

CSI 6300 SIS Overview

CSI 9330 Vibration Transmitter

AMS 6500 Machinery Health Monitor Chassis Options

Probe Pendulum for Eddy- Current Sensors

3500/45 Position Monitor

3500/45E Position Monitor

Ovation Machinery Health Monitor for the Power Industry

VMS Co., Ltd. VMS Reliability Systems - Korea

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

AMS 6500 ATG. Overview. API 670 compliant TSI protection system

M-series DC to DC Power Supply

M-series Intrinsically Safe I/O

DeltaV SIS Conditioning Components

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card

YTM Series Digital-Transmitter-Monitor

CSI 6500 Machinery Health TM Monitor

3500/77M Recip Cylinder Pressure Monitor

S-series Foundation Fieldbus I/O

DeltaV SIS TMConditioning Components

Faults on the system Proximity switch connection technology:

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

M-series Foundation Fieldbus I/O

Isolated Process Current Input with Loop Power 7B35

Digital Overspeed Protection System with PROFIBUS -DP interface DOPS, DOPS AS, DOPS TS

3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Product Specifications

Compact Speed Monitoring and Overspeed Protection System

3500/50E Tachometer Module

S-series H1 I/O Card with Integrated Power

DeltaV Bulk Power Supplies

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

S-Series DeltaV Controller Interface for PROVOX I/O

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Module VIB3000 Technical Data

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

3500/53 Electronic Overspeed Detection System

Micro Motion Model 7950 and Model 7951 Signal Converters

DeltaV Bulk Power Supplies

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

S-series Horizontal Carriers

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

3500/77M Recip Cylinder Pressure Monitor

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

DTM Distributed Transmitter Monitor

DeltaV Electronic Marshalling for Migrations

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

DeltaV M-series I/O Subsystem Horizontal Carriers

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

2301E ST Steam Turbine Control for Small Generator Applications

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

M-series MQ Controller

PD Channel Digital IO PD Series 600

ControlWave Micro Digital Input / Output Modules

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

MID approval no. DE-08-MI004-PTB004 Date of release

ControlWave Micro HART / BTI Interface Module

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

UniStream Uni-I/O Modules

S-series Sequence of Events Card

PHOENIX CONTACT - 01/2007

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

S-series Mass Connection Solutions

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Description. Specifications

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

AMS Suite: Machinery Health Manager 5.2 and 5.3 New Features and Enhancements

PT2060 Monitor. kmo turbo GmbH Friedrichstr Friedrichshafen Germany

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Operating instructions. Standstill monitor A / / 2011

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

PTT 280, 380 AND 480 WHITE PAPER

RSTI-EP Slice I/O. Digital Output Module

Voltage Transducer UMT516 / MT516

Ovation Ethernet Link Controller Module Data Sheet

digiclip Data sheet DF31DP Special features B en

Electronic Control Unit RC

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

M-series DeltaV Controller Interface for PROVOX I/O

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

Ethernet modules for length measurement, 24-bit 16/8/4 inductive transducers, LVDT, half-bridge

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

digiclip Data sheet DF31CAN Special features B en

" User s Manual. Adash 3900-II Online Vibration Monitoring System. Applications: Characteristics:

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Transcription:

Valve and Case Expansion Monitor Specifications The Valve and Case Expansion Monitor is designed for high reliability for the plant s most critical rotating machinery. This 1-slot monitor is used together with other CSI 6500 monitors to build a complete API 670 machinery protection monitor. Applications include steam, gas, compressors and hydro turbomachinery. The main functionality of the Valve and Case Expansion Monitor is to accurately monitor valve position and case expansion and reliably protect machinery by comparing parameters against alarm setpoints, driving alarms and relays. Valve position is a measurement of the main steam inlet valve stem position normally displayed in percent open. The valve position measurement provides the operator with an indication of the current load on the turbine. Case expansion monitoring usually consists of two inductive displacement sensor (or LVDT s) mounted in the axial direction, parallel to the shaft, and on each side of the turbine case. Unlike the eddy current sensor which is a non-contact sensor, the inductive sensor is a contact sensor. Case expansion monitoring is important at start-up, so both sides of the turbine case can be monitored for proper expansion rates. Because the turbine is allowed to slide on rails as it expands, if both sides are not free to expand, the turbine crabs (the case bends), leading to the rotor colliding with the case. Channel 1 can measure static values, such as case expansion, and can also be used for dynamic quantities, such as displacement, angles, forces, torsions or other physical quantities measured by inductive transducers. Channel 2 is left for static measurements and relative displacements (relative to channel 1). The CSI 6500 Machinery Health Monitor is an integral part of PlantWeb and AMS Suite. PlantWeb provides operationsintegrated machinery health combined with the Ovation and DeltaV process control system. AMS Suite provides maintenance personnel advanced predictive and performance diagnostic tools to confidently and accurately determine machine malfunctions early. n Two-channel, 3U size, 1-slot plug in module decreases cabinet space requirements in half from traditional four-channel 6U size cards n API 670 compliant, hot swappable module n Password protected user configuration n Self-checking facilities include monitoring hardware, power input, hardware temperature, sensor and cable n Front and rear buffered and proportional outputs, 0/4-20 ma output, 0-10 V output n Use with inductive displacement sensor 9350 www.assetweb.com/mhm

Transducer Inputs Number of inputs Type of inputs Emerson sensor inputs Isolation Input impedance Input voltage range Measuring frequency range Measuring Range Range Carrier Frequency Sensor power supply Nominal supply voltage Front Panel Outputs Green LED s Red LED s Front panel buffered outputs Mini DIN configuration socket Handle Analysis Measurement modes Configurable parameters Two, independent, differential inputs Inductive, half bridge or full bridge and differential transformers Part number: PR 9350/xx and K20315/xx Galvanically separated from power supply 200 kω 3.6 VDC (protected against over voltage) 0-100 Hz (-3 db) Continuously adjustable with configuration software One or both outputs may be inverted 4.75 khz Separate buffered sensor supply Galvanically separated from all system voltages and system supply voltage Open and short circuit proof 4 V rms 120-600 Ω Two LED s, indicates channel OK separately for each channel Four LED s, indicates alert and danger separately for each channel Two, identical to transducer sensor inputs ±12 V, >100 kω load Module interface connection for configuration and parameter and status monitoring RS-232 Easily remove card and provide plate for module and sensor identification Hot configurable for dual-channel measurement, expansion measurement Measuring range Engineering units Sensitivity Alert and Danger Page 2

Rear Outputs Available Current mode outputs Accuracy Settling time Rear Buffered Outputs Frequency range DC Voltage Outputs Accuracy Alarm Setpoints Alarm time delays Alert Danger OK Limit multiply Trip bypass 0/4-20 ma output for each channel proportional to main value <500 Ω ±1% of full scale Configurable, 0-10 seconds Raw buffered output signal, 0 to 12 V peak to peak 0-100 Hz (-3 db) >100 kω 0-10 VDC output proportional to main value ±1% of range >10 kω Selectable normally open, normally closed 0-5 second delay per channel 0-36 second delay with A6740 relay card Selectable to be blocked on channel not OK Adjustable range 5 to 100% of full scale value Resolution 1% of full scale value Alarm hysteresis on decreasing signal value, 0-20% of full scale value Selectable normally open, normally closed 0-5 second delay per channel 0-36 second delay with A6740 relay card Selectable to be blocked on channel not OK Adjustable range 5 to 100% of full scale value Resolution 1% of full scale value Alarm hysteresis on decreasing signal value, 0-20% of full scale value Self checking (normally closed): n power supply, sensor, cable, module checking, overload, internal temperature, system watchdog Green LED: n off when not OK n n during delay time, LED flashes reason for not OK can be read from communication bus Remote, relay input, 1.00-4.99 factor Remote, relay input Page 3

Environmental, General Module Front plate Climate Operating Temperature Storage Temperature Relative humidity Vibration Shock EMC resistance Power consumption Configuration IP 00, DIN 40050 IP 21, DIN 40050 DIN 40040 class KTF 0-65 C (32-149 F) -30-85 C (-22-185 F) 5 to 95%, non condensing IEC 68-2, part 6 0.15 mm, 10-55 Hz 19.6 mm/s 2, 55-150 Hz IEC 68-2, part 29 98 m/s 2 peak, 16 ms EN50081-1 / EN50082-2 Max. 6 W, 250 ma at 24 VDC Password protected Page 4

Ordering Information Model Number A6410 Product Description Dual-channel Valve and Case Expansion Monitor Emerson Process Management Asset Optimization Division 835 Innovation Drive Knoxville, TN 37932 USA T (865) 675-2400 F (865) 218-1401 2011, Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. All rights reserved. Machinery Health is a mark of one of the Emerson Process Management group of companies. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. Online Machinery Health Management powers PlantWeb through conditon monitoring of mechanical equipment to improve availability and performance. www.assetweb.com/mhm