VM series Cylindrical M2 in AC inductive sensors warranty features warranty Output: cable and M2 plug cable exit Models with 2 wires IP67 protection degree Multivoltage 20...253 Vac web contents Application notes Photos Catalogue / Manuals Cylindrical M2 in AC code description series housing output state version distance connect. VM 2 A C 0 2 B H AC M2 inductive proximity switch Standard body NO output state NC output state 2 wires version Shielded standard 2 mm Unshielded standard 4 mm Cable exit with tang M2 plug cable exit VM 2 / A 0 - B available models diameter installation distance plug distance (mm) NO NC M2 shielded unshielded standard cable with tang VM2/A0-B VM2/C0-B 2 M2 VM2/A0-H VM2/C0-H cable with tang VM2/A0-2B VM2/C0-2B 4 M2 VM2/A0-2H VM2/C0-2H VM 433
technical specification Cylindrical M2 in AC nominal sensing distance Sn operating distance hysteresis standard target repeatibility operating voltage inrush current output current output type leakage current switching frequency power on delay ambient temperature range temperature drift of Sr short-circuit protection LEDs protection degree EMC shocks and vibrations housing material active head material connection weight tightening torque VM2/**-* VM2/**-2* 2 mm 4 mm 0....6 mm 0... 3.2 mm... 20% 2x2 mm FE360 5% 20... 253 Vac 50/60 Hz 7A (Ton = 0 ms) 5... 300 ma RMS TRIAC NO or NC ma RMS max. 25 Hz 200 ms -25... +70 C 0% Sr - yellow (output energized) IP 67 () in conformity with the EMC Directive according to IEC 60947-5-2 IEC 60947-5-2 nickel-plated brass PBT cable 2 m PVC - plug M2 30 g M2 connector / 00 g cable 0 Nm () Protection guaranteed only with plug cable well mounted correction factors code steel FE 360 copper alluminium brass stainless steel VM2/**-* 0.40 0.55 0.75 0.50 VM2/**-2* 0.45 0.60 0.0 VM 434
electrical diagrams of connections M2 M2 BN/ BN/ BN BU BK brown blue black Cylindrical M2 in AC BU/3 BU/3 WH white response diagram parallel displacement VM2/*0-* parallel displacement VM2/*0-2* displacement (mm) displacement (mm) d (mm) d (mm) plug M2 ( ) 4 3 2 ( ) VM 435
D D D2 35 n D3 X X installation code D4 D D2 D3 Cylindrical M2 in AC D4 VM2/**-*.2 mm 2 mm 2 mm 6 mm VM2/**-2* 5 mm 4 mm 24 mm 2 mm dimensions (mm) VM2/**-B VM2/**-H ø 4.7 M2 x 7 ø.5 54.5 ø 2.5 53 45 42 63.5 ø 2.5 40.5 M2 x M2 x LED VM 436
X X VM2/**-2B VM2/**-2H 7 ø 4.7 ø.5 M2 x Cylindrical M2 in AC 59 ø 2.5 67 4.5 40.5 37.5 5 ø 2.5 36.5 5 M2 x M2 x dimensions (mm) accessories included in all M2 models M2 x 4 SW7 metallic nut (2 x) VM 437
notes VK 43
VK series Cylindrical M in AC inductive sensors warranty features warranty Output: cable and M2 plug cable exit Models with 2 wires IP 67 protection degree Multivoltage 20...253 Vac web contents Application notes Photos Catalogue / Manuals Cylindrical M in AC code description series housing output state version distance connect. VK 2 A C 0 2 B H AC M inductive proximity switch Standard body NO output state NC output state 2 wires version Shielded standard 5 mm Unshielded standard mm Cable exit with tang M2 plug cable exit VK 2 / A 0 - B available models diameter installation distance plug distance (mm) NO NC M2 shielded unshielded standard cable with tang VK2/A0-B VK2/C0-B 5 M2 VK2/A0-H VK2/C0-H cable with tang VK2/A0-2B VK2/C0-2B M2 VK2/A0-2H VK2/C0-2H VK 439
technical specification Cylindrical M in AC nominal sensing distance Sn operating distance VK2/**-* VK2/**-2* 5 mm mm 0... 4 mm 0... 6.5 mm hysteresis standard target repeatibility operating voltage inrush current output current output type leakage current switching frequency power on delay ambient temperature range temperature drift of Sr short-circuit protection LEDs protection degree EMC shocks and vibrations housing material active head material connection weight tightening torque () Protection guaranteed only with plug cable well mounted x mm FE360... 20% 5% 20... 253 Vac 50/60 Hz 7A (Ton = 0 ms) 5... 300 ma RMS TRIAC NO or NC ma RMS max. 25 Hz 200 ms -25... +70 C 0% Sr - yellow (output energized) IP 67 () in conformity with the EMC Directive according to IEC 60947-5-2 IEC 60947-5-2 nickel-plated brass PBT cable 2 m PVC - plug M2 30 g M2 connector 07 g cable 25 Nm 24x24 mm FE360 correction factors code steel FE 360 copper alluminium brass stainless steel VK2/**-* 0.35 0.40 0.50 0.0 VK2/**-2* 0.40 0.45 0.55 0.95 VK 440
electrical diagrams of connections M2 M2 BN/ BN/ BN BU BK brown blue black Cylindrical M in AC BU/3 BU/3 WH white plug M2 ( ) 4 3 2 ( ) response diagram VK2/*0-* parallel displacement VK2/*0-2* parallel displacement displacement (mm) displacement (mm) d (mm) d (mm) VK 44
D D D2 35 n D3 X X installation code D4 D D2 D3 Cylindrical M in AC D4 VK2/**-*.35 mm 5 mm mm 5 mm VK2/**-2*.5 mm mm 36 mm 24 mm dimensions (mm) VK2/**-B VK2/**-H M2 x ø 4.7 5.3 7 ø 73.3 ø 2.5 x 4 49.5 76.5 57 0 M x SW24 M x LED VK 442
X VK2/**-2B VK2/**-2H M2 x 7 0 X ø 4,7 ø 65. 5.3 ø 2.5 x 4 Cylindrical M in AC 42 69 M x 49.5 SW24 M x dimensions (mm) accessories included in all M models CH, 24 M X 4 metallic nut (2 x) VK 443
notes VT 444
VT series Cylindrical M30 in AC inductive sensors warranty features warranty Output: cable and M2 plug cable exit Models with 2 wires IP 67 protection degree Multivoltage 20...253 Vac web contents Application notes Photos Catalogue / Manuals Cylindrical M30 in AC code description series housing output state version distance connect. VT 2 A C 0 2 B H AC M30 inductive proximity switch Standard body NO output state NC output state 2 wires version Shielded standard 0 mm Unshielded standard 5 mm Cable exit with tang M2 connector exit VT 2 / A 0 - B available models diameter installation distance connection distance (mm) NO NC M2 shielded unshielded standard wire with tang VT2/A0-B VT2/C0-B 0 M2 VT2/A0-H VT2/C0-H wire with tang VT2/A0-2B VT2/C0-2B 5 M2 VT2/A0-2H VT2/C0-2H VT 445
technical specification Cylindrical M30 in AC nominal sensing distance operating distance hysteresis standard target repeatibility operating voltage inrush current output current output type leakage current switching frequency power on delay ambient temperature range temperature drift of Sr short-circuit protection LEDs protection degree EMC shocks and vibrations housing material active head material connection weight tightening torque VT2/**-* VT2/**-2* 0 mm 5 mm 0... mm 0...2. mm... 20% 2x2 mm FE360 5% 20... 253 Vac 50/60 Hz 7A (Ton = 0 ms) 5... 300 ma RMS TRIAC NO or NC ma RMS max. 25 Hz 200 ms -25... +70 C 0% Sr - yellow (output energized) IP 67 () in conformity with the EMC Directive according to IEC 60947-5-2 IEC 60947-5-2 nickel-plated brass PBT cable or M2 plug 30 g M2 connector 00 g cable 50 Nm () Protection guaranteed only with plug cable well mounted correction factors code steel FE 360 copper alluminium brass stainless steel VT2/**-* 0,40 0,55 0,75 0,50 VT2/**-2* 0,45 0,60 0,0 VT 446
electrical diagrams of connections M2 M2 BN/ BN/ BN BU BK brown blue black Cylindrical M30 in AC BU/3 BU/3 WH white plug M2 ( ) 4 3 2 ( ) response diagram VT2/*0-* parallel displacement VT2/*0-2* parallel displacement displacement (mm) displacement (mm) d (mm) d (mm) VT 447
X installation code D4 D D2 D3 Cylindrical M30 in AC D D D2 35 n D3 D4 VT2/**-*.2 mm 2 mm 2 mm 6 mm VT2/**-2* 5 mm 4 mm 24 mm 2 mm dimensions VT2/**-B VT2/**-H M2 x ø 5.5 3.7 22 X ø 75. ø 27. 50 0 50 ø 2.5 x 4 SW36 M30 x.5 SW36 M30 x.5 LED VT 44
X VT2/**-2B VT2/**-2H M2 x 22 X ø 5.5 ø 63. 3.7 ø 2.5 x 4 Cylindrical M30 in AC ø 27. 2 2 6 3 SW36 M30 x.5 SW36 M30 x.5 LED dimensions (mm) accessories included in all models SW36 M30 x.5 5 VT 449