APC APPLICATION NOTE #133

Similar documents
NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

APC Open Frame Rack Networking Solutions

How to Sell APC s Cisco Approved Solution for Nexus 7018

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

APC APPLICATION NOTE #146

Rack Systems. Rack enclosures and open frame racks for server and networking applications in IT environments

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

RACKS AND CABLE MANAGEMENT

Eaton Heat Containment System (HCS) Installation Guide

RE Series Rack from Eaton Product Presentation

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Heat Containment System (HCS)

Computer Network Design Guide Existing Systems 1 / 6

V800 Cabinet Solution

PLC Racks IC697CHS782/783

Rack Installation Instructions

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

APC APPLICATION NOTE #74

Vertiv VR Rack 1.0 GENERAL

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

or

System Storage EXP3000 Rack Installation Instructions

Target Interface / Construction Compliance Inspection Checklist

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

Titan Cable Management Catalog TCM3.0. IMS Engineered Products is ISO 9001 Certified. Designed and Manufactured in the USA

HPE Performance Optimized Datacenter (POD) Networking Guide

TYPE 4/12 PREMIER SERIES

PI Server - 19 enclosures

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

SYSTIMAX Rack and Cabinet Solution

MEMO. Manager7~ RICHARDSON TEXAS. June 5, 2018 DATE : Keith Dagen- Director of Finance TO: FROM : Todd Gastorf- Purchasing

H704-42(H)(E), H704-42/1(H)(E)

Ashly Power Amplifier

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

Thermal management. Thermal management

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

1 Getting Started Installing & Configuring

DATACOM CABINETS SOLUTION GUIDE

WIRE AND CABLE MANAGEMENT

Improving Rack Cooling Performance Using Blanking Panels

ICS Entrance Management Sign Installation Guide. Version 1.0

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

PACSystems RX7i IC698CHS009/119

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

IRONRIDGE PRODUCT CATALOG

APC APPLICATION NOTE #114

Enclosure and rack systems

Rack Mount Interconnect Center (RIC3)

Savant Host: SVR-4500S

CNC Tool Storage Solutions

Specification Sheet: HT SERIES

Data center solutions for successful companies. cable management solutions

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

CNC Tool Storage Solutions

Dimensions in mm in mm in. R in mm in mm mm. Weight. Dimensions in.

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

Enclosure and rack systems

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

ARCHITECTURAL GUIDELINES FOR INSTRUCTIONAL TECHNOLOGY

PowerChain Management solutions. Enclosure Solutions

Savant Call Server: SCS-3000

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

CMSA-100 Manual. Cinema Media Server Automation

Metropolis ADM MultiService Mux Compact Shelf

Project Olympus 2U Server Mechanical Specification

RACK READY TO SAVE 10% ON ALL RACKS AND ACCESSORIES

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

SNAP Compact Fiber Optic Patch Panel

GLYNN COUNTYIT DEPARTMENT

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

UltraRack. Advanced Data Centre Enclosures SR SERIES

QuickSpecs. HP Rack G2 Series Overview

VERTIV VR RACK. Selection Guide

Cutting Cabling Costs By Mike Martin

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12

CABINETS & CONTAINMENT SOLUTIONS GUIDE. designed to be better

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them.

Probably the fastest enclosure in the world

Savant Host: HST-4501

CVS -700 Vision System Specifying & Ordering Guide

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

TIA/EIA 568A Sub-system HORIZONTAL CABLING

Improve the appearance and accessibility of your rack

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

Knurr Miracel Server Rack

3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions

QuickSpecs. HPE G2 Advanced Series Racks. Overview

RCM & RCM+ enhancement

ACSUS-11. Access Cabinet Systems Cabinets & Accessories

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Quick Start Installation Guide

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

Agile Aircraft Installation Architecture In a Quick Reaction Capability Environment

CONCEPT Stainless Steel Wall-Mount Enclosures

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

V800. Cabinet V800 CABINETS

Transcription:

APPLICATION NOT #133 Cable Trough, Ladder, and Partition Configuration Guide By Bob Oliver Abstract Management of power and data cabling is critical for data center installation and long-term maintenance. APC has developed a line of products designed to contain and manage this array of cabling and piping. These products include cable troughs, ladders, and partitions. The following application note contains guidelines on positioning these products within a data center, determining cable capacity / fill of each product, planning for location of different services (power, data, cooling) within the data center, and installing these products. Introduction Generally speaking, data centers are made up of IT equipment housed in racks / enclosures or other physical structure (such as open frame racks). Data and power cabling are required to interconnect IT equipment in a single rack as well as across multiple racks in the data center. In addition, electrical conduits and piping are often required for cooling equipment. All cabling and piping must be supported, organized, and managed. The overhead trough / cabling system offered by APC is designed to serve this function. The system has three basic components: cable troughs, cable ladders, and partitions. The system is designed for quick, tool-less installation and can be configured in many different ways using the same basic set of components to offer maximum flexibility to meet the requirements and needs of each particular data center. Planning In most cases, the design and layout of the data center is driven by the physical dimensions of the space and additional considerations such as entry and exit locations for users, power source, and the amount and type of IT equipment to be installed. Since trough / cabling systems are flexible and can be adapted to many different data center configurations, the trough / cabling system layout is generally left until the above issues have been resolved. In most cases, when layout of the trough / cabling system begins, the physical locations of IT equipment, racks, and cooling equipment have already been determined. First determine cabling requirements for the data center The first consideration when designing a trough system for a data center is to determine the volume and type of cabling and piping that will need to enter and exit each rack or piece of cooling equipment. For example, for a rack populated with 40 1 _

servers, the number of cables exiting the rack can be as many as 120 data cables and 2 power cables. For a rack populated with switches and patch panels, the number of cables exiting the rack can be as many as 1,000 data cables and 1 power cable. The number and type of cabling can vary widely and should be determined as accurately as possible to ensure the most optimized trough system solution. Once the number of cables and piping that are passing in and out of each rack has been identified, the next objective is to determine the total volume and type of cables and piping that must pass over each rack (also over aisle ways and from row to row). Consider the following example. Figure 1 shows an example datacenter layout with four rows of three racks with two rows separated by an aisle way. For each rack, the number of data cables entering and / or exiting the rack is shown. Figure 1 xample data center layout with racks and data / power cable entering / leaving each rack Rack 1A Rack 1B Rack 1C Rack 3A Rack 3B Rack 3C 4 Power Rack 2A Rack 2B Rack 2C Rack 4A Rack 4B Rack 4C 327 Data 1 Power 231 Data 1 Power 4 Power 2

Figure 2 shows that same example datacenter with cable volume passing over each rack and over each row or aisle way. Figure 2 Quantities of cables passing over each rack from row to row and over the aisle way 14 Power Rack 1A Rack 1B Rack 1C 324 Data 14 Power 264 Data 1 204 Data 10 Power Rack 3A Rack 3B Rack 3C 4 Power 156 Data 8 Power 108 Data 4 Power 6 Data 14 Power Rack 2A Rack 2B Rack 2C 327 Data 1 Power 330 Data 1 231 Data 1 Power 231 Data 11 Power 228 Data 10 Power Rack 4A Rack 4B Rack 4C 168 Data 8 Power 4 Power 108 Data 6 Power Next determine cable volume at each location within the data center Once the cable volumes passing over each rack are known, the amount of trough space required at each rack can be determined. To prevent the risk of noise within data cables, power and data cables should be separated. Therefore, cable volume (or cable fill area) required for power and data cable should be considered separately. Calculations are made based on Article 392 of the National lectric Code which is the section which governs cable tray. According to the NC, cable tray is defined as a rigid structural support system used to securely fasten or support cables and raceways. APC s cable trough, cable ladder, and partitions fall under this definition since they are a rigid system when installed and are designed to support cabling. Calculations should be made as indicated in Table 1. ach APC cable trough is considered to be Solid Bottom Cable Tray with the width of the bottom equal to 6.25 inches. In some instances, a cable trough is not large enough to accommodate all of the cables required. In these instances, data partitions can be attached direction to the top of each rack. Data partitions can be attached at different locations on the rack so that the cable fill area can be increased. 3

Table 1 Calculation of cable fill for power and data cable in either a cable trough or between cable partitions Type of Cable Power Cable CFA = Data Cable CFA = Formula for Cable Fill Area Required (Max. # Cables) * pi * ((Cable diameter) / 2)² (Max. # Cables) * pi * ((Cable diameter) / 2)² Allowable Cable Fill Area per Trough Lookup from Table 392.9 of the NC based on: - Cable size - The fact that cable troughs are considered solid bottom tray - The width of the cable trough bottom is 6.25 in Allowable Cable Fill Area = 50% * (Cable Trough Usable Cross Sectional Area) Or Allowable Cable Fill Area 50% * ( Usable Area Between Cable Partitions) Calculations for xample Data Center Assume we are using 12 AWG (20A) cables so cable diameter = 0.471 in. CFA = (14 Cables) * 3.14 * (0.471 / 2) ² = 2.43 in² Width of cable trough bottom = 6.5 in Cable is < 4/0 so maximum fill area from Table 392.9 is 5.5 in². 2.43 in² < 5.5 in² so maximum number of power cables will fit in one trough. Assume we are using Cat 6 cables so cable diameter = 0.23 in. CFA = (330 Cables) * 3.14 * (0.23 / 2) ² = 26.5 in.² Cable Trough Usable Cross Sectional Area = 30 in.² Allowable Cable Fill Area = 50% * (30 in.²) = 15 in.² Cable will not fit into one trough. Use data partitions instead. Plan to set data partitions so they are a minimum of 11.5 inches apart at the base to achieve 26.5 in.² of Allowable Cable Fill Area. In many cases, cable ladders are required to bridge the gap between racks over aisle ways or between rows of racks. The cable capacity must be calculated for cable ladders as well to make sure the width and quantity of cable ladders is determined accurately. To prevent the risk of noise, it is considered good practice to make separate cable ladder runs for power and data cable. Perform calculations as indicated in Table 2. 4

Table 2 Calculation of cable fill for power and data cable on a cable ladder Type of Cable Power Cable CFA = Data Cable CFA = Formula for Cable Fill Area (Max. # Cables) * pi * ((Cable diameter) / 2)² (Max. # Cables) * pi * ((Cable diameter) / 2)² Allowable Cable Capacity per Ladder Lookup from Table 392.9 of the NC based on: - Cable size - The fact that cable ladders are considered ventilated / ladder bottom tray - The width of the cable trough bottom is 6.00 in. or 12.00 in. Allowable Cable Fill Area = 50% * (Ladder Width * 6 Max Fill Depth) Calculations for xample Data Center Assume we are using 12 AWG (20A) cables so cable diameter = 0.471 in. CFA = (14 Cables) * 3.14 * (0.471 / 2) ² = 2.43 in² Width of cable trough bottom = 6.0 in Cable is < 4/0 so maximum fill area from Table 392.9 is 5.5 in². 2.43 in² < 5.5 in² so maximum number of power cables will fit on one cable ladder. Assume we are using Cat 6 cables so cable diameter = 0.23 in. CFA = (168 Cables) * 3.14 * (0.23 / 2) ² = 6.97 in.² 6 Cable Ladder Allowable Fill Area = 50% * 6.00 * 6.00 = 18 in.² 6.97 in.² < 18 in.² so maximum number of data cables will fit on one cable ladder. Once the cable fill area and the type of cable management solution required have been determined, the next step is to determine where the cables, troughs, ladders and partitions will be located within the data center. Area on top of the rack APC cable troughs and partitions are attached to the roof of each APC rack. As a rule of thumb, the top of each rack has different areas reserved for different types of services (data, power, and piping). The layout of each rack top is shown in Figure 3. When a particular service type is not required or requires less space than indicated, this space can be used by another service. 5

Figure 3 Designated cable areas atop APC racks RAR (HOT AISL) Front and Rear Shaded Areas NOT Usable Cooling Power / Piping Zone Power Trough Zone Cooling Power / Data Cable Zone Data Partition Zone Cooling Power / Data Cable Zone SX Rack Frame RC Frame SX Wide Rack Frame SX Deep Rack Frame FRONT (COLD AISL) IN-ROW BASD COOLING PRODUCTS SHOWN For our example data center and based on Figure 3, cable troughs will be installed in the Power Trough Zone while data partitions will be installed in the Data Partition Zone. Six inch cable ladders will extend across the aisle way and from the rack row to the wall for cabling exiting the data center. One six inch cable ladder will connect the two rows of racks. The layout has been updated to show the cable troughs, partitions, and ladders included in the datacenter layout (See Figure 4). Some cooling products (such as several offered by APC) are designed to be installed in-row with racks. In those cases, space must be allocated above the racks for electrical conduits to the cooling equipment as well as piping for the coolant. 6

Figure 4 Data center configured with troughs, partitions, and cable ladders Rack 1A Rack 1B Rack 1C Rack 3A Rack 3B Rack 3C Troughs Partitions 6 Ladders Rack 2A Rack 2B Rack 2C Rack 4A Rack 4B Rack 4C Installation The following are some installation details showing how troughs, partitions, and ladders connect to APC racks as well as how they interconnect with one another. Attachment of cable troughs and partitions APC cable troughs and partitions are attached to APC racks without tools. Tabs on the bottom of each trough or partition snap into square holes in the rack roof. Ground wires are included with each trough and partition to chain all individual units together and then attach to a common ground (which is generally on the racks in the row). See Figure 5. 7

Figure 5 Cable trough and partition attachment Attachment of cable ladders to cable troughs and partitions (over aisle ways and between rows) APC cable ladders are generally used to span aisle ways and rows. They are designed to attach to cable troughs and partitions without tools. ach trough and partition has slots in each side that can accommodate either a 6 or 12 wide cable ladder fitted with a Ladder Bracket Kit (Part Number AR8166ABLK). Figure 6 shows the addition of a 12 wide cable ladder between rows and attached to either a partition or a trough. Figure 6 Cable ladder attachment 8

Cable ladders can also be attached over aisle ways to partitions or troughs. Figure 7 shows a cable ladder attached to partitions using the AR8166ABLK Ladder Bracket Kit. Attachment to a cable trough is completed in the same way. Grounding kits are provided to allow a grounded connection between the trough / partition and the cable ladder. Figure 7 Cable ladder attachment to partitions using ladder brackets Figure 8 shows attachment of a 6 cable ladder to a cable trough. Figure 8 Cable ladder attachment to trough using ladder brackets 9

Additional kits and accessories are available from APC. Please visit www.apc.com for additional details. See Table 3 for a partial list of available products: Table 3 APC product listing for cable troughs, ladders, partitions, and accessories Part Number Description Use For 600mm Wide Racks For 750mm Wide Racks AR8160ABLK AR8178BLK Power Shielding Trough Black Facilitates overhead power cabling distribution. Has protective grounding provisions. Tool-less mounting. Includes Installation Guide and (1) 20 cm grounding strap. AR8161ABLK AR8171BLK Power / Data Shielding Trough for Racks Black AR8162ABLK AR8172BLK Solid Shielding Partition for Racks Black AR8163ABLK AR8173BLK Pass-Through Shielding Partition for 600mm Wide Racks Black Facilitates overhead power or data cabling distribution. Has protective grounding provisions. Tool-less mounting. Includes Installation Guide and (1) 20 cm grounding strap. Facilitates overhead cable management. Has protective grounding provisions. Toolless mounting. Includes Installation Guide and (1) 20 cm grounding strap. Provides the ability to pass cables in and out of the cabling area contained by two partitions. Facilitates overhead cable management. Has protective grounding provisions. Tool-less mounting. Includes Installation Guide and (1) 20 cm grounding strap. AR8164ABLK AR8165ABLK 6 Wide Cable Ladder with Bracket Kit Black 12 Wide Cable Ladder with Bracket Kit Black Support data or power cabling across aisle ways or between rack rows. Support data or power cabling across aisle ways or between rack rows. AR8166ABLK Ladder Bracket Kit - Black Allows tool-less attachment of cable ladders to troughs and partitions. Includes Installation Guide. AR8168BLK Ladder to Rack Attachment Brackets Black Allows a cable ladder to attach direction to a rack. Tool-less mounting. Includes Installation Guide and (1) 20 cm grounding strap. 10

Conclusion With careful planning, cabling and piping can be accommodated within the data center. APC offers many products that install quickly and easily and can be adapted to many different layouts to help make this process more efficient and effective. About the Author: Bob Oliver is the ngineering Manager for Racks and nclosures for APC. He is responsible for design and development of racks and enclosures as well as rack accessories. Bob received a Bachelor s degree in Mechanical ngineering from the University of Missouri Columbia in 1992 and a Master s degree in ngineering Management from the University of Missouri Rolla in 1999. 11