Personal Sound Level Meter

Similar documents
Digital Sound Level Meter

Digital Sound Level Meter

User's Guide. Digital Sound Level Meter. Model

Digital Sound Level Meter

Digital Sound Level Meter MODEL

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

Pro II. Sound Level Meter V-9992

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Sound Level Meter SD Card real-time Datalogger

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

CM-140. Instruction Manual SOUND LEVEL METER G A L A X Y A U D I O

User's Manual Sound Level Alert Model SL130

Integrating Sound Level Datalogger Model

User s Manual. Sound Level Meter. FSM 30Plus. Lo/Hi MAX HOLD S/F. S F db BAT. SOUND LEVEL: Lo=35~100dB Hi=65~130dB. 94dB

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Sound Level Pen Instruction Manual

SOUND LEVEL CALIBRATOR DVM1356 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1356 SOUND LEVEL CALIBRATOR 1

Digital Sound Level Meter with USB Model:

User's Guide. EasyView K-Type Thermometer. Model EA11A

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Manual Sound level indicator PCE-353

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

USER S MANUAL. Data Logger SOUND LEVEL METER.

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

Formaldehyde Thermo-Hygrometer

INSTRUCTION MANUAL REC FAST A/C

ATE-9051 User s Manual

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

SOUND LEVEL DATALOGGER. Instruction Manual - 1 -

TES-1358 INSTRUCTION MANUAL

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Indoor Air Quality Meter/Datalogger

SOUND LEVEL METER INSTRUCTION MANUAL

Sound Level Calibrator

USER GUIDE. Noise Dosimeter with PC Interface. Model

Manual SOUND LEVEL METER PCE-322 A

Instruction Manual Digital Sound Level Meter

User's Manual. Digital Sound Level Meter. Model

1. GENERAL DESCRIPTION & SPECIFICATIONS

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Vibration Meter SD Card real-time datalogger

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

USER GUIDE. AC/DC Magnetic Meter. Model MF100

Contents. 1. Safety information 1 2. Description 2 3. Specifications 6 4. Operating instruction 8 5. Accessories 12

Heavy Duty Datalogging Light Meter

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

User Guide. Moisture Meter. Model MO250

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Heavy Duty Datalogging Light Meter

Light Meter SD Card real-time datalogger

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

Earth Resistance and Resistivity Tester

Model A Mini AC/DC Clamp Meter. User's Guide

DIGITAL SOUND METER WITH JUMBO DISPLAY

Ball Probe Moisture Meter With Bluetooth

Large Vane CFM/CMM Thermo-Anemometer

Pocket type SOUND LEVEL METER Model : SL-4030

Dual Moisture Meter Pin / Pinless Moisture Meter

User Manual. Thermocouple Datalogging Thermometer. Model EA15

DIGITAL SOUND LEVEL METER. Instruction Manual

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Hygro-Thermometer / Datalogger

USER GUIDE. Model Noise Dosimeter with PC Interface

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

Mini Digital Multimeter

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

4-Channel Thermometer / Datalogger

4-Channel Vibration Datalogger

Humidity & Temperature Datalogger

Model A Current / Voltage Calibrator. User's Guide

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

12-Channel Thermocouple Datalogger

Mini Photo Tachometer Model Mini Contact Tachometer Model

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

USER GUIDE. Differential Thermometer Datalogger. Model HD200

USER GUIDE Turbidity Meter Model TB400

Large Vane CFM/CMM Anemometer / Psychrometer

User s Manual. Model and Sound Level Calibrators

testo Sound Level Meter Instruction Manual

User's Guide. Extech AM A AC Analog Clamp Meter

User s Guide. 600A AC Clamp Meter. Model 38387

True RMS AC Voltage/Current Datalogger

Visit us at Back to the Extech Product Page

USER GUIDE Current Calibrator

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

USER MANUAL Video Particle Counter with built in Camera Model VPC300

ph/orp Meter SD Card real-time Datalogger

Humidity & Temperature Datalogger

Advanced Datalogging Sound Meter Instruction Manual

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Heavy Duty Vibration Meter

Transcription:

User's Guide Personal Sound Level Meter Model SL10

Introduction Congratulations on your purchase of the Extech SL10 Personal Sound Level Meter. The SL10 measures and displays sound pressure levels in db from 40 to 130dB with A weighting frequency response (dba). The LCD is backlit for viewing readings in dimly lit areas and includes a MAX-MIN feature. Careful use of this meter will provide years of reliable service. Safety Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. Environmental Conditions Altitude up to 2000 meters Relative Humidity: 90% max. Operating Temperature: 32 to 104 o F (0 to 40 o C) Maintenance and Cleaning Repair or servicing not covered in this manual should only be performed by qualified personnel. Periodically wipe the case with a dry cloth. Do not use abrasives or solvents. 2

Meter Description 1. Microphone sensor 2. Microphone chassis 3. Removable windscreen 4. Power switch 5. MAX-MIN button 6. LCD Backlight sensor 7. LCD Display Battery compartment and tripod mount located on rear of instrument Measurement Considerations 1. Wind blowing across the microphone increases the noise measurement. Use the supplied windscreen to cover the microphone when applicable. 2. Calibrate the instrument before each use if possible. Especially if the meter has not been used for a long period of time. 3. Do not store or operate the instrument in areas of high temperature or humidity. 4. Keep meter and microphone dry. 5. Avoid severe vibration. 6. Remove the battery when the meter is to be stored for long periods of time. 3

Operation 1. Power the meter by pressing the power button. The meter will begin displaying sound level readings. If the LCD does not switch on, check the 9V battery located in the rear battery compartment. 2. Hold the meter facing the microphone toward the source of the sound to be measured. For tripod use, the meter includes a tripod mount on the rear side of its housing. 3. View the measurement on the meter s LCD. An indication of OVER means that the measurement exceeds 130dB. 4. The meter automatically switches off after 15 minutes of inactivity to conserve battery energy. Press the power button to switch the instrument on again. A Frequency Weighting With A weighting, the frequency response of the meter is similar to the response of the human ear. A weighting is commonly used for environmental or hearing conservation programs such as OSHA regulatory testing and noise ordinance law enforcement. Fast Response Time The meter has a fast response time of 125 milliseconds (ms) in order to capture noise peaks and noises that occur very quickly. Over Range Alarm (OVER) If the measurement exceeds 130 db, the display indicates OVER. To avoid damage to the meter, do not continue to use the meter in an environment where the sound measured exceeds 130dB. MAX-MIN HOLD In this mode, the meter only updates the LCD reading when a higher reading (MAX mode) or lower reading (MIN mode) is detected. Select MAX HOLD by momentarily pressing the MAX-MIN button. The meter displays the MAX icon when in the MAX HOLD mode. Press the MAX-MIN button again to enter the MIN mode (the MIN icon will display). Press and hold the MAX-MIN button to exit this mode (the MAX-MIN indicators will switch off). Backlit LCD Display The LCD is equipped with backlighting for easier viewing, especially in dimly lit areas. The backlight automatically switches on and off based on ambient light conditions. The backlight sensor located just above the LCD display and just below the power button senses ambient light conditions. Battery Replacement When the low battery icon BAT appears on the LCD replace the 9V battery as soon as possible. The battery compartment cover is located on the rear of the meter. Slide the battery compartment cover off, change the battery, and replace the compartment cover. 4

Specifications Display Display update rate Microphone Measurement Bandwidth Measurement Range Frequency weighting 4-digit (4000 count) backlit LCD 0.5 seconds 0.5 Electret condenser 31.5Hz to 8KHz 40 to 130dB A (dba) Accuracy / Resolution ± 3.5dB (under 94dB reference conditions) / 0.1dB Response time Power Battery life Automatic power off Operating temperature Operating humidity 125 milliseconds 9V Battery 50 hours (typical); low battery indicator alerts user After approx. 15 minutes of inactivity 32 to 104 o F (0 to 40 o C) 10 to 90% RH Storage temperature 14 to 140 o F (-10 to 60 o C) Storage humidity Dimensions/weight Approvals 10 to 75% RH 8.3 x 2.2 x 1.3 (210 x 55 x 32mm) / 4.8oz (135g) CE Copyright 2013 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 5