HMT330 Series Humidity and Temperature Transmitters

Similar documents
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

PTU300 Combined Pressure, Humidity and Temperature Transmitter

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement

HMT330 Series Humidity and Temperature Transmitters for demanding humidity measurement

MMT330 Series Moisture and Temperature Transmitters for Oil

DMT345 and DMT346 Dewpoint Transmitters

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

DMT340 Series Dew Point and Temperature Transmitters

) a Direct Measure of Oil Quality. Water Activity (a w

M212022EN-A. User Guide. Vaisala HUMICAP â Humidity and Temperature Probes HMP4, HMP5, HMP7, HMP8, TMP1

humidity / dew point / moisture in oil / carbon dioxide / pressure / weather

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

DMT340 Series Dewpoint and Temperature Transmitters

HUMIDITY / DEW POINT / MOISTURE IN OIL / CARBON DIOXIDE / OXYGEN / BAROMETRIC PRESSURE / WIND

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Vaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method

CAEL-DP Series Dew Point Transmitter for Industrial Control

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

The industrial humidity transmitter

EE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

Humidity transmitter for critical climate applications

The industrial humidity transmitter

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

InBin-P Pressure switches from 5 Pa Pa

Humidity goes Digital

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

InCos-P Pressure sensor 20 Pa Pa

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

Humidity goes Digital

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

Product Guide. Repeatable RH and temperature measurement for precise humidity control and validation

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

DPL4000 Portable Low Range Dew Point Analyzer

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

SX 6000 Paperless Recorder

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

CDD4 Duct Carbon Dioxide Transmitter

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

MID approval no. DE-08-MI004-PTB004 Date of release

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

iologik E1200H Series

PTU200 Transmitter. Measuring Barometric Pressure, Humidity and Temperature

MCX08M2 Programmable controller

VPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Temperature Switches

Family of Water Cut Analyzers

H290 HUMIDITY TRANSMITTER INSTRUCTION MANUAL

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

Refrigerated incubators with forced convection

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

HLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

with serial RS485/RS232 output

ZFM ZFM DIGITAL MASS FLOW METER

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Conductivity Transmitters

HygroFlex HF3 Transmitters. User Guide

LBVR1718. Description. Features channel paperless recorder

BACnet Controller for General-purpose Building Applications

Precision Hand-held Thermometer

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

HygroFlex TF5 Temperature Transmitter. User Guide

PRESSURE TRANSMITTER

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

M211888EN-A. User Guide. Vaisala PEROXCAP â Hydrogen Peroxide Probe HPP271

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

HygroLog NT Humidity Temperature Data Logger Instruction Manual

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Transcription:

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement Features Full 0 100 %RH measurement, temperature range up to +180 C (+356 F) depending on model Pressure tolerance up to 100 bar depending on model 4th generation Vaisala HUMICAP â sensor for superior accuracy and stability Corrosion-resistant IP65/IP66 housing Excellent performance in harsh conditions; good chemical tolerance Traceable calibration for measurement and analog outputs (certificates included) 10-year warranty when annually calibrated at the Vaisala Service Center Vaisala HMT330 Series HUMICAP â Humidity and Temperature Transmitters are designed for demanding industrial applications where stable measurements and extensive customization are essential. With multiple options to choose from, the instrument can be tailored to meet the specific needs of each individual application and is pre-configured for each delivery. Proven Vaisala HUMICAP Performance The HMT330 series incorporates Vaisala s 40 years of experience in industrial humidity measurement. The updated fourth-generation HUMICAP â sensor provides accurate and stable measurement even in environments with high humidity or chemical contaminants. Wide Range of Installation Options The wide variety of measurement probes, several installation accessories, and universal mains and DC power options make the instruments easy to install in various locations and kinds of environment; walls, poles, pipelines, and ducts, for example. The input/output cable can be fed through the back of the transmitter, which is a useful feature, especially for cleanroom installations. The HMT330 series includes six models: HMT331 for wall-mounted applications HMT333 for ducts and tight spaces HMT334 for high-pressure and vacuum applications HMT335 for high-temperature applications HMT337 for high-humidity applications HMT338 for pressurized pipelines With multiple options to choose from, including local display, the HMT330 series can be tailored to meet the specific needs of each individual application and is preconfigured for each delivery. Sensor options include HUMICAP â 180R for general purposes and HUMICAP â 180 for fast response time or low-temperature applications; and HUMICAP â 180C and HUMICAP â 180RC for applications requiring chemical purge functionality. For best corrosion resistance combined with chemical purge, the latest sensor HUMICAP â R2 is recommended. Connectivity RS-232/485/422 LAN Modbus protocol support (RTU/ TCP) Optional graphical display and keypad for convenient operation Multilingual user interface Compatible with Vaisala viewlinc

HMT330 Series Humidity and Temperature Transmitters Graphical Display of Measurement Data and Trends for Convenient Operation The HMT330 series features an optional numerical and graphical display with a multilingual menu and keypad. It allows users to easily monitor operational data, measurement trends, and access measurement history of up to 4 years. The display shows measurement trends and over four years of real-time measurement history. The display alarm allows any measured parameter to be tracked, with freely configurable low and high limits. Versatile Outputs and Data Collection The HMT330 can support up to three analog outputs; an isolated galvanic power supply and up to four relay outputs are also available. For serial interface the USB service cable, RS-232, and RS-485/422 can be used. HMT330 is also capable of applying the Modbus communication protocol and, together with an appropriate connection option, provides either Modbus RTU (RS-485) or Modbus TCP/IP (Ethernet) communication. The data logger, with real-time clock and battery backup, guarantees reliable logging of measurement data for over four years. The recorded data can be viewed on the local display or transferred to a PC with Microsoft Windowsâ. The transmitter can also be connected to a network with an optional LAN interface, which enables an Ethernet connection. A USB service cable makes it easy to connect the HMT330 to a PC via the service port. HMK15 salt bath calibrator in a controlled environment. The transmitter can also be sent to Vaisala for recalibration, and accredited ISO/IEC17025 calibrations and special calibrations are available. Chemical Purge Minimizes Effects of Contaminant In environments with high concentrations of chemicals and cleaning agents, the chemical purge option helps to maintain measurement accuracy between calibration intervals. The chemical purge involves heating the sensor to remove harmful chemicals. The function can be initiated manually or programmed to occur at set intervals. Flexible Calibration The HMT330 instruments are calibrated at five humidity points at the factory and come with a calibration certificate that meets all the relevant traceability and compliance requirements. A quick, one-point field calibration can be performed with the handheld HM70 meter. A two-point field calibration can be performed, for example, with the HMT331 HMT333 HMT334 HMT335 HMT337 HMT338 For Measurement within rooms General purposes High pressure and vacuum applications High temperatures High humidity applications Pressurized pipelines Operating Temperature -40... +60 C (-40... +140 F) -40... +80 C (-40... +176 F) or -40... +120 C (-40... +248 F) 40... +180 C (-40... +356 F) -40... +180 C (-40... +356 F) -40... +180 C (-40... +356 F) -40... +180 C (-40... +356 F) 0... 1 MPa (0... 10 bar) 0... 4MPa (0... 40 bar) Operating Pressure 0... 10 MPa (0... 100 bar)

HMT330 Series Measurement Performance Mechanical Specifications Relative Humidity Measurement range 0... 100 %RH Accuracy (including non-linearity, hysteresis, and repeatability) at +15... +25 C (59... +77 F) ±1 %RH (0... 90 %) at -20... +40 C (-4... +104 F) at -40... +180 C (-40... +356 F) Factory calibration uncertainty (+20 C) Response time (90%) at +20 C (+68 F) in still air Temperature Accuracy at +20 C (+68 F) ±1.7 %RH (90... 100 %RH) ±(1.0 + 0.008 x reading) %RH ±(1.5 + 0.015 x reading) %RH ±0.6 %RH (0... 40 %RH) ±1.0 %RH (40... 97 %RH) (Defined as ±2 standard deviation limits. Small variations possible; see also calibration certificate.) 8 s/17 s with grid filter 1) 20 s/50 s with grid + ting filter 1) 40 s/60 s with sintered filter 1) ± 0.2 C (± 0.36 F) Accuracy over temperature range (measurement range depends on model) Cable bushing Conduit fitting User cable connector (optional) option 1 option 2 Probe Cable Diameter HMT333 (+80 C) other probes Standard probe cable lengths Housing material IP rating Weight depending on selected probe, cable and modules M20 x 1.5 for cable diameter 8... 11 mm/0.31... 0.43" 1/2" NPT M12 series 8-pin (male) female plug with 5 m (16.4 ft.) black cable female plug with screw terminals 6.0 mm 5.5 mm 2 m, 5 m or 10 m (Additional lengths available, see order forms for details) G-AlSi 10 Mg (DIN1725) IP66 IP65 (NEMA4X) with local display 1.0-3.0 kgs C 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-80 -60-40 -20 0 20 40 60 80 100 120 140 160 180 Temperature sensor Pt100 RTD Class F0.1 IEC 60751 Other Available Variables (Model-Dependent) dew point temperature, mixing ratio, absolute humidity, wet bulb temperature, enthalpy, water vapor pressure 1) With HUMICAP 180R or 180RC or 180VC sensor C Dimensions in mm (inches) Operating Environment Operating Temperature for probe for transmitter body with display Storage temperature EMC compliance same as measurement range -40... +60 C (-40... 140 F) 0... +60 C (32... 140 F) -55... +80 C (-67... 176 F) EN61326-1, Industrial Environment Note: Transmitter with display test impedance of 40 Ω is used in IEC61000-4-5 (Surge immunity)

Inputs and Outputs Mounting Options Operating Voltage 10... 35 VDC, 24 VAC ±20% with optional power supply module 100... 240 VAC, 50/60 HZ Power Consumption at +20 C (Uin 24 Mounting with Wall Mounting Kit (not mandatory for wall installations) Mounting with DIN Rail Installation Kit VDC) RS-232 max. 25 ma Uout 2 x 0... 1 V/0... 5 V/0... 10 V max. 25 ma Iout 2 x 0... 20 ma max. 60 ma display and backlight + 20 ma during chemical purge max. 110 ma during probe heating (HMT337) + 120 ma Analog Outputs (2 standard, 3rd optional) current output 0... 20 ma, 4... 20 ma voltage output 0... 1 V, 0... 5 V, 0... 10 V Accuracy of analog outputs at +20 C ±0.05% full scale Pole Installation with Installation Kit for Mounting Rain Shield with Installation Pole or Pipeline Kit Temperature dependence of the analog ±0.005%/ C full scale outputs External loads: current outputs RL < 500 Ω 0... 1 V output RL > 2 kω 0... 5 V and 0... 10 V outputs RL > 10 kω Max. Wire Size 0.5 mm2 (AWG 20) stranded wires recommended Digital outputs RS-232, RS-485 (optional) Protocols ASCII commands, Modbus RTU Service Connection RS-232, USB Relay Outputs (Optional) 0.5 A, 250 VAC Ethernet Interface (Optional) Supported standards 10BASE-T, 100BASE-TX Connector 8P8C (RJ45) IPv4 address assignment DHCP (automatic), static Protocols Telnet, Modbus TCP/IP Optional Data Logger with Real-Time Clock Logged parameters max. four with trend/min/max values Logging interval 10 sec. (fixed) Max. logging period with max. temporal resolution 4 years, 5 months Logged points 13.7 million points per parameter Battery lifetime min. 5 years Display LCD with backlight, graphical trend display of any parameter Menu languages English, Chinese, Finnish, French, German, Japanese, Russian, Spanish, Swedish Vaisala Meteorological Installation Kit HMT330MIK enables HMT337 to be installed outdoors to obtain reliable measurements for meteorological purposes

HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications Cleanrooms Pharmaceutical processes Swimming halls Data centers Archives Vaisala HUMICAP â Humidity and Temperature Transmitter HMT331 is a high-quality wall-mounted transmitter for demanding HVAC and condition-monitoring applications. -40... +60 C (-40... +140 F) HMT331 with short cable probe Dimensions in mm (inches) Connection cable for HM70 211339 Wall-mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 DIN rail installation set 215094

HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces Vaisala HUMICAPâ Humidity and Temperature Transmitter HMT333 is a versatile instrument for applications where a small remote probe is needed, for example in demanding HVAC applications. Its small thermal mass enables rapid response to temperature changes. Flexible Installation To install the probe in ducts, channels, and through walls, an installation kit is available with a stainless steel flange, leadthrough piece, and steel support bar. HMT333 has two probe cable options a flexible rubber cable that withstands temperatures of up to +80 C, and a durable FEP cable that withstands temperatures of up to +120 C. Both cable options are available in lengths of 2, 5, and 10 meters. Additionally, flexible rubber cable (+80 C) is available in 20meter lengths. Cleanrooms For outdoor environments, the DTR502B solar radiation shield provides protection for the probe. The shield can be installed on a pole, beam, or flat surface. Industrial HVAC systems Environmental chambers Processes with moderate temperature and humidity 5) 50 (1.97).9-40... +80 C (-40... +176 F) or -40... +120 C (-40... +248 F) Installation flange dimensions M26x1.5 2 (0.08) M9 1.5 ø9 ) Duct installation kit for HMT333 99.5 (3.92) Dimensions in mm (inches) Duct installation kit 210697 Cable gland with split seal HMP247CG Connection cable for HM70 211339 Wall-mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 Solar radiation shield DTR502B DIN rail installation set 215094 PPS plastic grid filter DRW010276SP 37 90 37.5 (1.48) 79.5 (3.13) (0. ø 12 (0.47) ø7 5 The installation flange allows easy adjustment of the probe installation depth. (2 14 (0.55)

HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications Test chambers High-pressure and vacuum processes Vaisala HUMICAP â Humidity and Temperature Transmitter HMT334 is designed for humidity measurement in pressurized spaces or vacuum chambers. Every probe is tested for gas and vacuum-tight installation. Operating pressure ø12 (0.47) 41 (1.61) Dimensions in mm (inches) 120 (4.72) 170 (6.69) -40... +180 C (-40... +356 F) 0... 10 MPa (0... 100 bar) M22 1.5 or NPT 1/2" Fitting body NPT 1/2" 17225SP Connection cable for HM70 211339 Wall-mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 DIN rail installation set 215094 PPS plastic grid filter Stainless steel grid filter Fitting body ISO M22 x 1.5 DRW010276SP HM47453SP 17223SP

HMT335 Humidity and Temperature Transmitter for High Temperatures Hot drying processes Food processes, e.g. baking ovens Robust Probe Ideal for High Flow Rates The Vaisala HUMICAPâ Humidity and Temperature Transmitter HMT335 has a long stainless steel probe designed for high temperatures. With high tolerance for mechanical stress and high flow rates, HMT335 is ideal for duct measurements. The stainless steel installation flange allows easy adjustment of the probe s installation depth. Long, robust probe allows easy installation through insulation in ovens and similar applications. (2 ø7 5 2 (0.08).5 ø9 41 (1.6) -40... +180 C (-40... +356 F) ø13.5 (0.53).9 5) 50 (1.97) M26x1.5 ) 37 (0. 90 51 (2.0) 192 (7.56) 14 (0.55) Installation flange dimensions 253 (9.96) Dimensions in mm (inches) Mounting flange 210696 Connection cable for HM70 211339 Wall-mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 DIN rail installation set 215094 PPS plastic grid filter DRW010276SP Stainless steel grid filter HM47453SP Flange installation kit for HMT335

HMT337 Humidity and Temperature Transmitter for High Humidity Applications 2. HMT337 with a warmed probe, for dew point temperature measurement under constant near-condensing conditions 3. HMT337 with a warmed probe and an additional temperature sensor, for relative humidity measurement under constant nearcondensing conditions True Humidity Readings in Condensation Conditions Vaisala s unique warmed probe provides fast and reliable measurement in environments where humidity is near saturation. The heating prevents condensation from forming on the sensor. As the probe is heated, the relative humidity level inside it stays below the ambient level. With accurate temperature measurement, the ambient dew point temperature can be calculated precisely. Intake air monitoring of engines and gas turbines Timber drying kilns HMT337 Configurations Vaisala HUMICAPâ Humidity and Temperature Transmitter HMT337 is ideal for the most demanding process and meteorological measurements in high-humidity condensing environments. HMT337 is delivered in one of three configurations: 1. Basic HMT337, with a non-warmed probe for applications where humidity levels are not constantly near condensation -40... +180 C (-40... +356 F) Duct installation kit (RH A pressure and vapor tight installation up to 10 bars through a process wall can be achieved by sealing with Swagelokâ fittings from the probe, or sealing from the cable with a gland. The optional HMT330MIK Installation Kit is available for outdoor installations; duct installation kits are also available. Groove for lock ring HMP247CG probe)1) Duct installation kit (T probe) Installation Options 1) 210697 37.5 (1.48) 215003 79.5 (3.13) Swagelok fittings (NPT and ISO) for both RH and T probes (up to 10 bar) DTR502B Meteorological installation kit HMT330MIK Connection cable for HM70 211339 Wall-mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 DIN rail installation set 215094 Warmed probe accessory HMT330WPA PPS plastic grid filter DRW010276SP Stainless steel grid filter HM47453SP For more installation accessories, check the order form. 1) For an image of the duct installation kit, see HMT333 page. 99.5 (3.92) HMT337 RH Dimensions in mm (inches) Ø 6 (0.24) Solar radiation shield Ø 3.2 (0.13) Cable gland for probe cable If the relative humidity value is needed, an optional temperature sensor is used (configuration option 3). The measured ambient temperature provides the compensation for calculating relative humidity and other temperature-dependent humidity parameters. M9 1 Professional meteorology ø 12 (0.47) 135 (5.31) HMT337 T Dimensions in mm (inches)

HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines Process lines Environmental chambers Vacuum-drying processes Compressed air lines with refrigerant dryers Vaisala HUMICAP â Humidity and Temperature Transmitter HMT338 is ideal for installations in pressurized processes where the probe needs to be removed while the process is running. Insert or Remove the Probe while the Process is Running With hot tapping, the probe is inserted directly into the process while it is running, without the need for venting or lowering the process pressure.the probe is tightened to a ballvalve assembly fixed to the process pipe or wall. The adjustable hex nut is hand-tightened to temporarily hold the probe in place. The probe is then pushed down to the appropriate depth. The hex nut is then tightened with a wrench to lock the probe in place. Hot tapping is possible in pressures up to 10 bar. Operating pressure Dimensions -40... +180 C (-40... +356 F) 0... 4MPa (0... 40 bar) Ball-valve set BALLVALVE-1 Pressure fitting ISO 1/2 to NPT 1/2 210662 Connection cable for HM70 211339 Wall-mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 DIN rail installation set 215094 PPS plastic grid filter Stainless steel grid filter DRW010276SP HM47453SP Published by Vaisala B210951EN-K Vaisala 2017 www.vaisala.com All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. Any reproduction, transfer, distribution or storage of information contained in this document is strictly prohibited. All specifications technical included are subject to change without notice.