Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Similar documents
VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- RELAY OUTPUT FR-A5AR

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

FR-A8AR INSTRUCTION MANUAL

INVERTER INSTRUCTION MANUAL. Analog output function Digital output function. Plug-in option FR-A7AY PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

FR-PU07 QUICK START MANUAL

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- COMMUNICATION OPTION FR-A5NC

Installation, Operation and Maintenance Manual

Table of Contents Product Overview Before using the product Installation Procedure... 5

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

INSTRUCTION MANUAL. communication function. Plug-in option FR-A8ND PRE-OPERATION INSTRUCTIONS INSTALLATION WIRING INVERTER SETTING FUNCTIONS

FR-A7NC E kit cover SC

Instruction Sheet WPC 2000 Option 1

FR-A7NCN INSTRUCTION MANUAL. communication function. Plug-in option PRE-OPERATION INSTRUCTIONS INSTALLATION WIRING INVERTER SETTING FUNCTIONS

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- COMMUNICATION OPTION FR-A5ND

MITSUBISHI TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- Option. DeviceNet TM FR-E5ND MITSUBISHI ELECTRIC

FR-A7ND INSTRUCTION MANUAL

Manual FC 3500 DC Fan Control

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

SMVector Additional I/O Module Installation and Operation Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TRANSISTORIZED INVERTER

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Digital ac/dc (24V) Input Module

Analog Monitor Installation Manual

Installing Your 1394 Drive Interface Module

GPIB-232CT-A IBCL EPROM Installation Guide

MOS-1110Y-0101E Isolated 16 DI/8 DO, 1-Ch, DB37, PCIe I/F

Model 7705 Control Module

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

TRANSISTORIZED INVERTER

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

D700 QUICK START MANUAL

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

MDM 011-Z1 Regen Resistor

Model 2380 Rack-Mount Kit

INVERTER INSTALLATION GUIDELINE. FR-F to NA FR-F to NA

FR-PU04 TRANSISTORIZED INVERTER INSTRUCTION MANUAL PARAMETER UNIT PRE-OPERATION INFORMATION. Chapter 1. FUNCTIONS Chapter 2. HELP Chapter 3 FR-PU04

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128

Analog Input Installation Manual

OPLC Installation Guide

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Model 2380 Rack-Mount Kit

PS/IO Circuit Board Retrofit

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TRC-190 User s Manual

Resolver to Digital Expansion Board

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

13 MMC for PC Option Modules

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

AutoMax Network Communication Option Board for use with GV3000/SE AC Drives M/N 2AX3000

25 South Street, Hopkinton, MA

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Installation Instructions

User Manual. Solar Inverter for Water Pump

Profibus/DP Communication Option

Allen-Bradley Drives

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Vision OPLC V TR6/V350-J-TR6

24/48/120 VAC Interface Card Instruction Manual

INVERTER FR-A800 INSTALLATION GUIDELINE FR-A (0.4K)

Lightning Stitch Assembly

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User safety and equipment protection guidelines

FX1N-2EYT-BD Output Expansion Board

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

FLEX Ex Spring Clamp Terminal Base

Please read here first

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TABLE OF CONTENTS 1. OVERVIEW... 1

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

PV Rapid Shutdown device

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Inverter (VFD) Manual

V E62B Snap-in I/O Module

KBMG MULTI-SPEED BOARD

SMVector Additional I/O Module Installation and Operation Manual

Bulletin 1336 Adjustable Frequency AC Drive 1336 B075 B C075 C VT B075 B150. Troubleshooting Guide

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

TRANSISTORIZED INVERTER INSTRUCTION MANUAL FR-E5NC

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

The following conventions are used to indicate precautions in this manual.

Model 2657A-LIM-3 LO Interconnect Module

PFC Mini TM Power Factor Corrected AC-DC Switchers

TPE 1464 Series Pressure Transducer

Transcription:

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01 AC Input Interface Option Unit

NOTE: CAUTION: WARNING: NOTES, CAUTIONS AND WARNINGS Notes are used to provide additional detail about a procedure. The Note will always precede the text that the Note refers to. Cautions provide additional detail where failure to observe the Caution may result in damage to the equipment or slight injury to the user. Warnings provide additional information, where failure to observe the Warning may result in death or severe injury SAFETY INSTRUCTION 1. Electric Shock Prevention WARNING: Do not open or remove the front cover while the Variable Frequency Drive is running. You may get an electrical shock. When necessary to perform inspections or when wiring the unit, switch power off and wait at least 10 minutes and until the bus charge light is off. Check for residual voltage. Do not attempt to inspect or wire any VFD or option unit unless you are fully competent to perform the work. Be sure hands are dry before operating any switches. Be sure cables do not have scratches, excessive stress, heavy loads or pinching to prevent electrical shock 2. Injury Prevention CAUTION: Be sure all connections are in accordance with instructions in this manual Check that cables are properly connected before turning equipment on. 1

After turning equipment off, wait at least 10 minutes and until the bus charge light is off before removing cover. With cover removed, charged components may be exposed. 3. Additional Cautions and Warnings CAUTION: Do not install the option unit if it is damaged or has parts missing Check that option unit is securely fastened to the variable frequency drive. Do not stand or rest heavy objects on top of unit. Do not allow metal fragments, conductive bodies, oil or other flammable substance to enter the variable frequency drive. Before starting operation, confirm and adjust the parameters. Failure to do so may cause the machines to make unexpected motions. When parameter clear or parameter all clear is performed, each parameter returns to the factory setting. Reset the required parameters before starting operation For prevention of damage caused by static buildup, touch a nearby grounded metal object to remove static from your body. Dispose of this product as general industrial waste. WARNING: Do not modify this equipment 2

Table of Contents Table of Contents... 3 1. Introduction...4 1.1 FR-A5AC-01 Structure...5 Figure 1: Top view...5 Figure 2: Connection Diagram...5 1.2 FR-A5AC-01 Signal Description...6 Table 1: A500(L) Interface Functions...6 Figure 3: Jumper Diagram...6 2. Installation...7 2.1 Unpacking the FR-A5AC-01 Option...7 Figure 4: Option Cable...7 2.2 Pre-Installation Checks...8 2.3 Mounting Procedure...8 Figure 5: Drive View...9 Figure 6: Cable Routing View...9 Figure 7: Wiring Diagram...10 3. FR-A5AC-01 Operation...12 3.1 AC Interface Operation...12 Table 2: AC I/O Terminal Description...12 3.1.1 VFD terminal block control input terminals...13 3.1.2 User Selectable Terminal Functions...14 3.1.3 Parameter Functions...14 Table 3: Control Signal Parameters...15 3.1.4 Parameter Settings...15 Table 4: Control Signal Parameter Settings...19 3.1.5 Parameter Setting Notes...20 4. FR-A5AC-01 Specifications...21 5. References...21 Mitsubishi Electric...21 Technical Support Number...21 6. Revisions...21 7. User Note s Section...22 3

1. Introduction Thank you for choosing this AC input interface option unit for the Mitsubishi FR-A500(L) series transistorized frequency VFD's. Please read this manual carefully before using this option unit. This instruction manual gives handling information and precautions for use of this product as well as the information required for the installation of the FR-A5AC-01 option. It is assumed that the reader of this manual possesses an understanding of the configuration, implementation, and operation of Mitsubishi FR-A500(L) series VFD's Please forward this manual to the end user. AC Input Interface Option Unit (FR-A5AC-01) This option unit lets you connect a FR-A500(L) series VFD with up to eight 120 VAC input signals which are then isolated and connected to the FR-A500(L) 24 V signal input terminal block. Some important features of this option unit include: All input functions are electrically isolated to 1000 volts from the VFD User selectable input functions. Can be used with communications options. Designed and assembled in the U.S.A. UL & C-UL Approved. 4

1.1 FR-A5AC-01 Structure Figure 1: Top view Figure 2: Connection Diagram 5

1.2 FR-A5AC-01 Signal Description Name FR-A5AC Input Terminal Block (J2) FR-A5AC Control Signal Terminal Block Cable (VC2C105A016) FR-A5AC Firmware Support Jumper (Jump1) Description Eight 120 VAC inputs, X1 X8, and a common. Terminals 1A,1B,1C & 2A,2B,2C are not available. FR-A5AC output signal for the A560(L) VFD's control signal terminal block, Y1 Y8 This jumper is not used and should be in the AC input only location. Table 1: A500(L) Interface Functions Figure 3: Jumper Diagram 6

2. Installation 2.1 Unpacking the FR-A5AC-01 Option 1. Check that all required components were received from the factory. The FR-A5AC-01 option should have the following items included. 1 Instruction Manual VC2BNA00031 1 Option Terminal Block Cable VC2C105A016 Figure 4: Option Cable 1 FR-A5AC-01 Option in an anti-static bag. C2C132U080 2 3 x 8 mm Machine Screws VSP896M205 2. The FR-A5AC-01 option should be left in the antistatic bag until installation to prevent damage caused by ESD. CAUTION The option module is sensitive to Electro-static discharge. Proper ESD measures required. 7

2.2 Pre-Installation Checks Remove the VFD cover carefully, following the directions given in the VFD instruction manual. Be sure to install the option unit using the following procedure: NOTE: The FR-A5AC-01 jumper JUMP1 is factory set to the A.C. INPUT ONLY position. 2.3 Mounting Procedure WARNING HAZARDOUS VOLTAGE PRESENT Always isolate power from the VFD and wait 10 minutes until the bus charge light is off and check for residual before inserting or removing this option unit or touching the terminals. 1. Make sure the VFD input line power is off and the charge light on the VFD shows that the VFD is not storing an electrical charge, always check for residual voltage. Refer to the VFD instruction manual if necessary. You may damage the option unit if you install it with the line power connected. 2. Insert the FR-A5AC-01 option unit into VFD s option port #2 or option port #3 (option port #1 is not recommended for easy wiring when installed). Carefully insert the connector of the option unit into the connector of the VFD. Use the two mounting holes and the guide hole to align the option with the matching machine screw inserts and the plastic guide pin on the VFD. Make sure that the FR- A5AC-01 option is firmly seated in the VFD and the connector is completely plugged in and secured. 8

Figure 5: Drive View Figure 6: Cable Routing View 9

3. Secure the option unit to the VFD with two mounting screws. If the screw holes in the option unit do not line up with the VFD mounting holes, check that the connectors have been fitted correctly. 4. Route the 120 VAC signal cables and the control signal terminal block cable along the side of the VFD case as shown in figure 6. Figure 7: Wiring Diagram 10

5. When wiring the option follow local electrical codes concerning proper wire gauge and circuit protection. 6. All external signals are connected to the option through the options terminal block labeled for signal Identification. The terminal block is UL & CSA approved for 28-16 AWG wire. 7. The 120VAC inputs are located at terminals X1 to X8 with common CM. The corresponding isolated outputs are the terminals labeled Y1 to Y8 and are designed to be connected directly to the VFD terminal block control input terminals via the FR- A5AC-01 control signal cable. The FR-A5AC-01 control signal cable can be connected to any 8 of the 11 standard input signals. 8. Any unused terminals from the cable should be removed or properly insulated to prevent accidental shorting. CAUTION Insulate or remove any unused terminals from the terminal block cable to prevent accidental shorting. 9. After connecting the terminal block cable to the VFD, plug the connector on the other end into the socket J1 on the FR-A5AC-01 AC Input Interface option. 10. Finally replace the VFD cover, while making sure that the signal wires are not caught or pinched between the cover and the chassis. 11

3. FR-A5AC-01 Operation The operation of the A500(L) VFD does not change when you install the FR-A5AC-01 option unit. The option features an eight input 120 VAC interface function. The eight 120 VAC inputs are converted to be used with the VFD s control signal terminal block to enter the command signals. 3.1 AC Interface Operation By using the 120VAC inputs to enter command signals, any terminal block functions can be implemented including running a motor in the forward or reverse rotation direction. The 120VAC inputs are isolated and entered into the VFD as open collector signals. Signal Name Description X1,X2,X3,X4, X5,X6,X7,X8 CM (Note 1) Y1,Y2,Y3,Y4, Y5,Y6,Y7,Y8 120 VAC control input Signal 120 VAC control input Signal Common Open Collector Output 120VAC Input signals Common terminal to X1- X8 (Isolated from VFD Control Circuit) Output signals corresponding to X1 X8 as open collector signals. Connect to the control input terminals of the VFD. Common terminal handled internally. Table 2: AC I/O Terminal Description Note: sink logic must be used on the VFD s control signal terminal block, see the A500(L) instruction manual for more details. 12

3.1.1 VFD terminal block control input terminals The FR-A5AC-01 outputs, Y1-Y8, can be connected to the following VFD control signal terminal block terminals. 1. STF: When the input signal is asserted into the STF terminal, the motor rotates in the forward direction. When the signal is removed, a stop command is given. 2. STR: When the input signal is asserted into the STR terminal, the motor rotates in the reverse direction. When the signal is removed, a stop command is given. 3. STOP: When the input signal is asserted into the STOP terminal, the self holding feature is enabled. 4. RH, RM, & RL: When the input signal is asserted into the RH, RM, or RL terminal respectively, and the appropriate multiple speed functions are enabled. 5. JOG: When the input signal is asserted into the JOG terminal, the JOG operation can be performed with the STF or STR signal. 6. RT: When the input signal is asserted into the RT terminal, the second acceleration / deceleration times are enabled. The second torque boost and second base frequency can also be selected with this function when set correctly. 7. MRS: When the input signal is asserted into the MRS terminal for 20 ms or longer, the stop command is given to the motor and the motor is stopped by the magnetic brake. 8. RES: When the input signal is asserted into the RES terminal for 0.1 s or longer, and then removed, the VFD will reset. 9. CS: When the input signal is asserted into the CS terminal, the VFD will restart after an instantaneous power failure. Note that this 13

feature requires that the restart parameters be set. When the VFD is shipped from the factory it is set with this feature disabled. 10. AU: This terminal should not be used by the FR- A5AC-01 option. 3.1.2 User Selectable Terminal Functions Several of the terminals listed above are user selectable to implement different functions when the signal to that terminal is asserted. The RL, RM, RH, RT, AU, JOG, & CS terminals are of this type and are set with the A500(L) parameters 180-186. See the A500(L) instruction manual for more details. 3.1.3 Parameter Functions The following parameters are used to change the VFD control signal terminal blocks functions. The terminals listed below can be changed by the user, and can implement any one of several functions. The valid value range for parameters 180-186 are 0 to 99, & 9999. Parameter Number Terminal Symbol Factory Setting Factory Setting Terminal Function 180 RL 0 Low Speed Operation Command 181 RM 1 Medium Speed Operation Command 182 RH 2 High Speed Operation Command 183 RT 3 Second Function Selection 184 AU 4 Current Input Selection 185 JOG 5 Jog Operation Selection 14

Parameter Number Terminal Symbol Factory Setting Factory Setting Terminal Function 186 CS 6 Automatic Restart After Instantaneous Power Failure Table 3: Control Signal Parameters 3.1.4 Parameter Settings Use the following list for setting parameters, Pr. 180-186. Setting = 0 Signal Name: RL Function: When PR 59 = 0, Low speed operation command, see the A500(L) manual for more details. Relevant Parameters: PR 4 to PR 6, PR 24 to 27, PR 232 to PR 239 Function: When PR 59 = 1,2 *, Remote Setting (acceleration) Relevant Parameters: PR 59, Function: When PR 79 = 5 *, Programmed operation group selection. Relevant Parameters: PR 79, PR 200, PR 201, PR 210, PR 211, PR 220, PR 221, PR 230, PR 231 Function: When PR 270 = 1,3 *, Stop on contact selection 0. Relevant Parameters: PR 270, PR 275, PR 276 15

Setting = 1 Signal Name: RM Function: When PR 59 = 0, Middle speed operation command. Relevant Parameters: PR 4 to PR 6, PR 24 to 27, PR 232 to PR 239 Function: When PR 59 = 1,2 *, Remote (deceleration) Relevant Parameters: PR 59, Setting Function: When PR 79 = 5 *, Programmed operation group selection. Relevant Parameters: PR 79, PR 200, PR 201, PR 210, PR 211, PR 220, PR 221, PR 230, PR 231 Setting = 2 Signal Name: RH Function: When PR 59 = 0, High speed operation command. Relevant Parameters: PR 4 to PR 6, PR 24 to 27, PR 232 to PR 239 Function: When PR 59 = 1,2 *, Remote Setting (setting clear) Relevant Parameters: PR 59, Function: When PR 79 = 5 *, Programmed operation group selection. Relevant Parameters: PR 79, PR 200, PR 201, PR 210, PR 211, PR 220, PR 221, PR 230, PR 231 16

Setting = 3 Signal Name: RT Function: Second function selection Relevant Parameters: PR 44 to PR 50, Function: When PR 270 = 1,3 *, Stop on contact selection 1 Relevant Parameters: PR 270, PR 275, PR 276 Setting = 4 Signal Name: AU Function: Current input selection. Relevant Parameters: Setting = 5 Signal Name: JOG Function: JOG operation selection. Relevant Parameters: PR 15, PR 16, Setting = 6 Signal Name: CS Function: Automatic restart after an instantaneous power failure selection. Relevant Parameters: PR 57, PR 58, PR 162 to PR 165 Setting = 7 Signal Name: OH Function: External thermal relay input** The externally provided overheat protection thermal relay, motor embedded temperature relay or the like is operated to stop the VFD. Relevant Parameters: 17

Setting = 8 Signal Name: REX Function: 15 Speed selection (in combination with RL, RM, & RH) Relevant Parameters: PR 4 to 6, PR 24 to 27, PR 232 to PR 239 Setting = 9 Signal Name: X9 Function: Third Function Relevant Parameters: PR 110 to 116 Setting = 10 Signal Name: X10 Function: FR-HC connection (VFD operation enable) Relevant Parameters: PR 30, PR 70 Setting = 11 Signal Name: X11 Function: FR-HC connection (instantaneous power failure detection) Relevant Parameters: PR 30, PR 70 Setting = 12 Signal Name: X12 Function: PU operation external interlock Relevant Parameters: PR 79 Setting = 13 Signal Name: X13 Function: External DC dynamic breaking start Relevant Parameters: PR 10 to PR 12 Setting = 14 Signal Name: X14 Function: PID control valid terminal Relevant Parameters: PR 128 to 134 18

Setting = 15 Signal Name: BRI Function: Brake opening completion signal Relevant Parameters: PR 278 to 285 Setting = 16 Signal Name: X16 Function: PU-external operation switch-over Relevant Parameters: PR 79 Setting = 17 Signal Name: X17 Function: Load pattern selection forward/reverse rotation boost Relevant Parameters: PR 14 Setting = 18 Signal Name: X18 Function: Advanced magnetic flux vector-v/f switch-over Relevant Parameters: PR 80, PR 81, PR 89 Setting = 19 Signal Name: X19 Function: Load torque high-speed frequency Relevant Parameters: PR 271 to 274 Setting = 9999 Function: NO function Signal Name: Table 4: Control Signal Parameter Settings *: When PR 59 = 1 or 2, PR 79 = 5, and PR 270 = 1 or 3, the functions of the RL, RM, RH, & RT signals change as listed above. **: Operated when the relay contact opens 19

3.1.5 Parameter Setting Notes 1. One function can be assigned to two or more terminals. In this case, the terminal inputs are OR Ed together. 2. The speed command priorities are higher in order of JOG, and then multi speed setting RH, RM, and RL. 3. When HC connection (VFD operation enable signal) is not selected, the MRS terminal shares this function. 4. When advanced magnetic flux vector-v/f switchover and load pattern selection forward/reverse rotation boost are not selected, the second functions (RT) share these functions. 5. Use common terminals to assign programmed operation group selection, multi-speeds (7 speeds) and remote setting. They cannot be set individually. 6. Stop-on-contact control section PR 270 = 1 or 3, shares RT with multi speed setting (low speed), and its allocation cannot be changed. 7. When FR-HC connection VFD operation enable (X10) signal is not assigned, the MRS terminal shares this function. 8. When PR 79 = 7 and the PU operation external interlock (x12)signal is not assigned, the MRS signal acts as this function. 9. When the load pattern selection forward/reverse rotation boost (X17) signal is not assigned, the RT signal shares this function. 10. When advanced magnetic flux vector-v/f switchover (X18) signal is not assigned, the RT signal shares this function. 20

4. FR-A5AC-01 Specifications 1. AC Input Voltage: 90 132 VAC 2. Operating Temperature 10 ~ 50 C 3. Storage Temperature(1) -20 ~ 56 C 4. Relative Humidity <= 90% @ 50 C, noncondensing. 5. Dimensions 96 x 49 x 18 mm (1) This refers to a short period of time such as during transportation. 5. References Mitsubishi Electric FR-A500(L) VFD Instruction Manual Technical Support Number 800-950-7781 6. Revisions Print Date Manual Number Revision June 2000 VC2BNA000031 REV A Original Version 21

7. User Note s Section 22

Mitsubishi VFD Instruction Manual FR-A5AC-01 2000 Mitsubishi Electric Automation, Inc. FR-A5AC-01 Auxiliary Control Option Unit VC2BNA00031 Revision A June 2000