User Guide Automatic Transfer Switch (ATS)

Similar documents
Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Pulsar EXtreme 2000/3000 VA

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

INTELLIGENT SERVER. Model: BMS-LSV6E

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

Model HM-535 Power Supply Installation and Service Instructions

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Installation and user manual English Français Deutsch Italiano Español Nederlands Pulsar Series

* * Agilent Power Distribution Unit (PDU) Installation Guide

Party Dimmer IEC ORDERCODE 50324

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

EATON 5S 850/1200/1600

Rack Mount Power Supplies

DS-1H05 Ethernet-over-Coax Extender. User Manual

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

Broadband Automatic Disconnect Switch. User Manual

LED SPIDER MOVING HEAD LIGHT

PowerMust Office Uninterruptible Power System

PM3020FSNL/PM3028FSNL 16-Port 10/100Mbps+2 Gigabit TP/SFP Combo PoE Switch 24-Port 10/100Mbps+2 Gigabit TP/SFP Combo PoE Switch

User's Guide. Model W 3-in-1 Switching DC Power Supply

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

RPX Series USER S MANUAL

MODEL 805 USER MANUAL

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

POWERWALKER. Uninterruptible Power Supply. Line Interactive VI 1000/1400/2000. Thank you for purchasing PowerWalker UPS.

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

Daily use. indicating that the loud speakers

Powerware 3105 UPS User s manual

PRE116/126. User Manual.

MA V 60W Mixer Amplifier Order code: CRAM05 MA V 120W Mixer Amplifier Order code: CRAM06 USER MANUAL

CS2 DMX Distribution Splitter

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

Zonit μats TM Users Guide μats1-lv Version 1.2

Installation Manual of DS-9600NI-H8 DS-9600NI-H8. Installation Manual UD.7L0202A1730B01

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

APT20. User Manual.

TPC25 active crossover. user manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

Powerware 3105 UPS User s manual

EFRP-x462 SERIES. Industrial Computer File Server System Raid Subsystem

Our Company is a specialist in the design, development and manufacturing of uninterruptible power supplies (UPS).

U-150 Integrated Amplifier User s guide

icore Kiosk system Installation Guide

1 Channel Strobe Controller ORDERCODE 40226

RGB Power Batten. User Manual. Order code: EQLED032

DMX LED Starcloth Systems

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

UV Power Flood. User Manual. Order code: EQLED029

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

User Manual. Solar Inverter for Water Pump

Installation and Operation

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Innovative Circuit Technology Ltd.

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Blitzer Strobe. User Manual. Order code: EQLED366

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

MICRON DJ Booth Tri-colour Starcloth

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Liebert PSA5. Installer/User Guide

Network Camera. Quick Guide DC-B1203X. Powered by

4170 POS System Installation Guide

POWER DISTRIBUTION UNITS

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

MICRON DJ Booth System with Overhead Kit & CW Starcloth

Octostrip ORDERCODE 42220

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

VTPC190V / VS / VDC / VSDC

Liebert PSI5. Installer/User Guide

Gobo Projector XP 80W

KINKI STUDIO EX-M1 INTEGRATED AMPLIFIER INSTRUCTION MANUAL. - We are from China -

CPA 40 Two Channel Amplifier

Vector Beam White. User Manual. Order code: LEDJ265

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

This device can be installed by anyone on the condition that he/she has READ THE USER AND SAFETY MANUAL CAREFULLY.

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Quick Start Guide and Health and Safety Information

Alternative B Type Mid-Span Power Sourcing Equipment. User s Guide

Crossfire. User Manual. Order code: EQLED061

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

ZEPHYR Compact Haze Machine

Transcription:

User Guide Automatic Transfer Switch (ATS) V.1.0

Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation... 5 6. Operation... 6 7. Communication Port... 6 8. Trouble Shooting... 8 9. Specifications... 9 10. Appendix:... 10 1

1. Introduction This ATS product is designed with two independent power inlets to supply power to the load from a primary power source. Should primary power source fail, the secondary will automatically back up the connected equipment without any interruption. The transfer time from one line to another is seamless to the connected equipment. After switching to a secondary power source, the ATS can also switch power back to the primary input when power to the primary input is restored. Package contents: ATS module User manual mounting brackets 2. Product Overview Front View: Power switch for input source A Power switch for input source B Circuit breaker for output 2 Circuit breaker for output 3 USB communication port RS-232 communication port Communication slot Operation indicators (please refer to section 4 for the details) Back View Contact port (please refer to section 7 for the details) Output receptacles Output 3 (IEC 10A) Output receptacles Output 2 (IEC 10A) Output receptacle Output 1 (IEC 16A) Input source A connector Input source B connector 2

3. Important Safety Warnings Before using the unit, please read all instructions and cautionary markings on the unit, this manual and the batteries. WARNING!! The ATS must be connected to earth when in use. In line with current regulations, only use the cables that have been supplied with the machine. The power supply socket must be easily accessible to the operator. WARNING!! The ATS has been designed exclusively to operate indoors. It is advisable to install it in areas where no inflammable liquids or gases, or other harmful or noxious substances, have been stored. ATTENTI!! A soft damp cloth may be used to clean the outside of the machine (always with the system disconnected from the mains power supply and users). Do not use any type of solvent as this may damage the external finishing of the machine. ATTENTI!! The ATS has been designed exclusively for professional use. NOTE: These instructions may be modified by the wiring regulations in force in the country where the ATS is purchased. 4. Operation Indicators & Status Source preference selector Priority setting LEDs Power source status LEDs Output source LEDs Fault indicator Alarm mute button 3

Indication type LED description LED status Condition Alarm Priority setting LEDs Power source status Output status Alarm Source A ( ) Source B ( ) Source A ( ) Source B ( ) Status of source A ( ) Status of source B ( ) source A ( ) source B ( ) source A ( ) source B ( ) source A ( ) source B ( ) Fault ( ) Source A is priority Source B is priority Inlet A has no power input Flashing Inlet A has power input, and power is OK Inlet A has power input, but power is out of SPEC Inlet B has no power input Flashing Inlet B has power, and power is OK Inlet B has power input, but power is out of SPEC Power A is output Power B is output NO OUTPUT Alarm not present Alarm present Continuously 4

5. Installation NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Mounting the Unit The unit can be mounted in a standard 19" rack. Fasten the mounting brackets to the unit using the screws provided. With brackets attached securely, users can mount the unit in a standard 19" rack as shown below. NOTE: If the temperature around the unit will rise above 40 C, ventilation is required Connecting the Unit For connecting the ATS, plug input source A connector and input source B connector to the two independent power sources or UPSs depending using the SCHUCKO-IEC or IEC-IEC 16A cables supplied. Plug the user load to the output 10A ( Output 1 and 2 ) or 16A ( Output 3 ) sockets depending on user s requirements. 5

6. Operation Power On/Off Put the input power switch in position. The output will then be supplied by the source set as selected. Setting priority of power source It is possible to set the power source preference to supply the output by pushing the button of source preference selector. The default power source is Source A. Function Description Default Source perference selector Selection of input that normally supplies the load Source A Possible configuration Source A Source B 7. Communication Port The ATS is supplied with the following communication ports: Serial port is available with RS232 com. port and USB com. port on the front panel. NOTE: the use of one port automatically excludes the other. Contacts port on the rear panel. Serial Ports: RS-232 & USB connectors RS-232 connector USB connector PIN # NAME TYPE SIGNAL PIN # SIGNAL 1 1 VBUS 2 TX OUT Serial line TX 2 D- 3 RX IN Serial line RX 3 D+ 4 4 GND 5 GND POWER 6 +12V POWER 7 8 9 NOTE: The utilization of the communication port is optional and it is not necessary for the correct functioning of the ATS. 6

Contact Ports The contacts port is formed using six (6) pins numbered from left to right (see fig. 1), which can be connected to an external monitoring system (such as a BMS) in order to monitor the operational status of the ATS. The external equipment must respect the voltage and current characteristics of contacts port. Fig. 1: Focus on contacts port. The contacts port provides the following pins: Pin 1: common contact. Pin 2: Source B active contact (if the contact between pin 1 and pin 2 is closed, output is supplied by Source B ). Pin 3: Source A active contact (if the contact between pin 3 and pin 1 is closed, output is supplied by Source A ). Pin 4: Source A status OK contact (if the contact between pin 4 and pin 1 is closed, Source A is present and regular). Pin 5: Source B status OK contact (if the contact between pin 5 and pin 1 is closed, Source B is present and regular). Pin 6: Status OK contact (if the contact between pin 6 and pin 1 is closed, ATS functioning status is regular). The following diagram shows the functioning of the contacts port. Fig. 2: Contacts port basic diagram. ATTENTI: The pins of the contact port are able to carry maximum current of 8A and maximum voltage of 250Vac. 7

8. Trouble Shooting Use the table below to solve minor problems. Problem Possible Cause Solution The ATS with the mains voltage present, does don t turn on. (The LEDs does not flash and no alarm sounds.) The load is not powered. The display shows nothing or provides incorrect information. The display is off but the load is powered. No connection with input plugs Input switch in position Input power failure Protective device upstream activated No connection with output sockets Intervention of 10A thermal protection There is power supply problem in display. There is power supply problem in display. Connect the mains to the input plugs as indicated in the installation section. Turn the input switches in position. Check that the mains voltage is present or check if the UPS supplying the ATS is powered on. Reset the protective device. Warning: check that there is no overload or short-circuit at the output of the UPS. Connect the load to the output sockets The thermal protection device will operate in the event of a short circuit or overload on one of the 10A output sockets. The thermal protection can be reset by pushing the button in which will result in the power being reconnected to the load. Therefore prior to attempting a reset of the thermal protection, please check the connected loads rating and/or determine if there are any problems. Then once reset, reconnect each load one at a time to ensure no problems exists. Shut down the ATS completely and wait for a few seconds. Switch the ATS on again, if the problem persists, contact the nearest technical support centre. Contact the nearest technical support centre. If there is any abnormal situations occur, which doesn't list above, please call the service people immediately for professional examine. 8

9. Specifications MODEL ATS INPUT Input Voltage Acceptable Input Voltage Range Input Frequency Maximum Input Current 220/230/240 VAC 180-258 VAC 50 Hz/60 Hz 16 A OUTPUT Output Voltage Maximum Output Current CNECTI Input Output Communication TRANSFER TIME 220/230/240 VAC 10 A for IEC-C13 outlets 16 A for IEC-C19 outlet 2 x IEC-C20 inlets 8 x IEC-C13 1 x IEC-C19 USB/RS-232 9-12ms (Typical) PHYSICAL Dimension, D X W X H (mm) 330 X 483 X 44 Net Weight (kgs) 5.0 ENVIRMENT Operating Temperature 0-95 % RH @ -5 C- 45 C (non-condensing) 9

10. Appendix: Input Voltage and Frequency Thresholds FUNCTI Acceptable input voltage range for Source A Return voltage point for Source A Acceptable input voltage range for Source B Return voltage point for Source A Acceptable input frequency for Source A Acceptable input frequency for Source B DESCRIPTI Source A will be power source during this range. When input voltage of source A is beyond this range, ATS will automatically switch to power from Source B. When input voltage of Source A is back to normal, the ATS will switch back to Source A. (Setting Source A as priority power source and Source B is powering) Source B will be power source during this range. When input voltage of source B is beyond this range, ATS will automatically switch to power from Source A. When input voltage of Source B is back to normal, the ATS will switch back to Source B. (Setting Source B as priority power source and Source A is powering) Source A will be power source during this range. When input frequency of source A is beyond this range, ATS will automatically switch to power from Source B. Source B will be power source during this range. When input frequency of source B is beyond this range, ATS will automatically switch to power from Source A. DEFAULT SETTING 180V 258V Low point: 190V High point: 248V 180V 258V Low point: 190V High point: 248V 45Hz 55Hz 45Hz 55Hz 10