The electronic nip measurement is now connected Download TabletMeasure Apps from the Google Play Store. You can use the keyword: tabletmeasure or diginip Install and accept to access to these services. tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 1/10
When the App is launched it is necessary to connect a TabletMeasure module to unlock the App. Switch on the module Push the chromium pushbutton, the Led flashes in blue each 2 seconds. A form invites you to subscribe to receive updates and information about the new features offered by TabletMeasure. The email address is mandatory. Then the App starts. The next time to launch the application, simply click on the TabletMeasure icon: Tap on the screen display tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 2/10
Tap the text "TAP" then select the visible TabletMeasure module. The LED of the module flashes with the same color than the color channel on the tablet. The module is connected and displays a value of 0.0 mm. Pressing "+" key on the top right of the screen, a second channel opens to connect a second module. The pairing is performed in the same manner as above. To remove a module, press 3 seconds on the desired channel on the screen (on-screen display 0.0) the module disconnects and goes out; the module's LED stops flashing. You can also press 3 seconds the module pushbutton to disconnect it. tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 3/10
Screen example with values transmitted by the modules: Sensor, here: DigiNip Analog level for each channel Battery level per channel Led On or Off Unit of measurement (mm or milinch) TabletMeasure function keys Android function keys Function keys on the button bar of the application TabletMeasure : A long press on a key function shows the name at the top of the screen. Setting Note Hold Memorization More. Unit of measurement mm ou milinch. Color channel. Switch Led «idea box». Written or vocal message. Hold the value on the display (The key function is blue and the value on the screen flashes). A short press stores the measurement. A long press lists stored values (here 8). More functions. Measurement campaigns. List of stored values. Status. Help Setting. Unit of measurement: mm ou milinch. Channel Color. Switch On or Off the Led tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 4/10
Note Written or vocal message Hold Hold the values on the display. The key is colored blue when this feature is active, and the values flash on the screen and no longer vary even if other measures are realized. In case of memorization it is the measured value which is stored and not the flashing on the screen. Memorization To memorize the value press the key briefly. The number written near the icon indicates the number of memorized data. To see the value memorized, press 2 sec on the same key. The list shows the date and time of the measurement, and the measurement for each module. The last stored measurement is No. 01. tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 5/10
To share / export this list by email, FTP, Cloud and communicate to the outside, press Share. The format is csv, you can open it with Excel. If necessary, change the file name without changing the extension *.csv. To share choose your service. More. More functions With this exclusive feature, prepare, store and perform measurement campaigns, share, execute, and report the results in a report automatically generated test. 1- Tap on the Prepare key. 2- Choose to take a picture with the integrated camera (take the picture and confirm), or select an existing stored in the tablet. 3- The image is displayed on the top left of the screen. Resize by zooming / de-zooming. 4- Validate the image size by pressing the Finish key. 5- Tap on the image at the desired location for indicating a measurement point. After 3 seconds a dialog box opens and asks you to select the sensor type used (DigiNip, DigiMatic... Here, it is DigiNip) 6- Enter the desired target value to be measured. If unknown, leave blank, default 0. 7- Repeat as many times as necessary to add unlimited measurement points. 8- Confirm by pressing the Finish key to save the campaign with the default name proposed or with yours. 9- To measure, select the test campaign template by pressing Measure key. 10- The image appears and the red data points are displayed. tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 6/10
11- Press the red dot and perform the measurement. Long press: details, move, delete. 12- The measurement window is displayed and when the nip value is reached, confirm the measurement by pressing the Record key or the module pushbutton. 13- The image appears again, and the measures may continue, knowing that the green dots represent the measurements. 14- To share / export this campaign (or test report) by email, FTP, Cloud... and communicate outside, press the Share key. 15- The file name is completed by the word "data" and incremented. If necessary, change the file name without changing the extension *.zip, and then select the application to share. 16 - Then save the campaign by pressing the Confirm key and save the file with a suitable name. tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 7/10
To delete files, simply select them and press the Trash key. Represents the list of values stored by the Memory key and / or the module pushbutton. Displays the versions of Android software, App TabletMeasure, module software and its circuit, MAC addresses of connected modules. Allows the user to return useful information to improve the application TabletMeasure. Access to the manual. TabletMeasure.com support@tabletmeasure.com tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 8/10
Replacement of the sensor and/or the battery Open the cover by rotating the ring in the opposite direction of the clockwise. Use the tip of the cover, go there under the sensor and lift from the printed circuit. Or remove the battery. Replace the sensor or a new battery and close the cover. Place ¼-turn-screw in this position and first press to push the screw and turn it with the ring in the direction of clockwise by ¼ turn. If problems If the application crashes (eg due to Android or manufacturer over-layer hardware customization), you can stop the process and restart the application. Press the Recent Apps key on your device. It appears all the active Apps. Stop the TabletMeasure App by simply slide it down and it disappears from the list. The App is completely interrupted. Then just restart the App tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 9/10
Warranty We guarantee the absence of material defects of DigiNip for a period of one year from the date of shipment. The warranty covers only the material that has been used properly and has not been subject to misuse, repair or unauthorized modification. During the warranty period, our responsibility is limited to the repair or replacement of defective hardware. We do not guarantee the DigiNip against misuse, and assume no responsibility for any misuse. We are in no way liable for damages resulting from the maintenance and / or staff errors. We are not in any way liable for the consequences of the results obtained with these instruments. These measures may be different from those made by other methods. This warranty does not include the sensor or battery. The sensor being subjected to operational constraints at the time of use (bending, deformation, contact with ink...), it cannot be guaranteed. It is guaranteed for one year before use. For repair guaranteed equipment, shipping charges are for the customer. We will bear the cost of returning the equipment after repair. Regarding DigiNip no longer under warranty, shipping and return are at the customer's expense. We reserve the right to make changes without committing to modify existing products. EC approval The DigiNip complies with Directive 89/336 /EEC EMC and has the following standard: EN61326-1 (1997) Class A Emission and Immunity. Registered The name "DigiNip" is a trade name deposited at the National Institute of Industrial Protection. International patent The device is protected by an international patent KRIER SAS No. WO2006106239 (A1). Environmental Information The batteries used in this device contain chemicals that are harmful to the environment. This is why you need to throw them to the specific measures for the recovery of used batteries, in accordance with regulations of the country, state and locality. How to eliminate (Waste Electrical and Electronic Equipment) This symbol on the product or its literature indicates that it should not be disposed of at end of life with other household waste. The uncontrolled disposal of waste that can harm the environment or human health, please separate this from other types of wastes and recycle it responsibly. You will promote the sustainable reuse of material resources. Individuals are invited to contact the retailer where they purchased this product, or inquire at their town hall to where and how they can take this item for environmentally safe recycling the environment. Businesses should contact their supplier and check the conditions of the purchase contract. This product should not be disposed of with other commercial waste. KRIER SAS FRANCE BP.39 F-78371 PLAISIR Cedex contact@krier-sa.com krier-sas.com tabletmeasure.com Krier-sas + 33 1 30 07 54 50 DigiNip 2 Operating manual v6.1 Page 10/10