DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE

Similar documents
DATA SHEET DEVIO SCR-20 CONFERENCING HUB

DATA SHEET DEVIO CR-1 CONFERENCING HUB

DATA SHEET DEVIO DEVIO CR-1 CONFERENCE ROOM DEVICE

DATA SHEET TESIRAFORTÉ DAN AI

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone

xin 4, xio 4x4 and xout 4

Biamp Price List 01 April 2019 MODEL DESCRIPTION RETAIL EXCL VAT Devio

TeamConnect Ceiling Ceiling microphone conference system

CHAT 50 Personal Speakerphone. Quick Start Guide

Spider MT503 SMART USER MANUAL. Page 1

LPT-C2 & LPT-C6 ListenPoint Standard & Advanced Control Unit (CU)

CHAT 150 CHATAttach 150 Group Speakerphone. Quick Start Guide

TitanONE Smart Mainframe Power Amplifier

The TesiraFORTÉ family offers several different models. Each TesiraFORTÉ

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

The 5.8mm diameter ROM-2235L-HD-R is designed for extreme fidelity in a compact housing with true 20 Hz to 20 khz performance.

DA-250 DSP Stereo Array Microphone Module Specification

Professional Audio Conferencing Products - CONVERGE Pro 2 Series

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

TeamConnect TeamConnect System - The perfect audio solution for meetings

Audia. AudiaFUSION. Manual

Spider MT503 SMART USER MANUAL. Page 1

PHS Series. PowerHUBB Node - Satellite

SMART Audio classroom amplification systems Model CAS-340

REDCAT ACCESS DETAILED SPECIFICATIONS

VS-88UT All in One Presentation System with 8x8 4K60 4:2:0 HDMI/HDBaseT 2.0 Matrix Switching, Master Room Controller, PoE & Power Amplifier

Vocia ELD-1. Operation Manual

ControlSpace EX-1280C conferencing processor

Brocade ICX 6610 Switch

Q-SYS NV-32-H Preliminary Specifications Q-SYS NV-32-H. Features. Native integration and control for the Q-SYS Ecosystem

ACCESS LINK DETAILED SPECIFICATIONS

USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 304

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

VIPEDIA-12. Cameo specification sheet. Product Description

Audio Zone Amplifier 2 x 20 watts Installation Guide

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

IP-ZCM. PoE+ IP to Analog Gateway (Zone Controller)

SYNAPSE. High Channel Density Networked Audio Interfaces AES67. Common Features DM 1. D32 o. D32 i. Product Family Overview. Applications.

CDI DriveCore Series. Features \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

QM-AE1. QuickMedia Audio Extractor

AUD-220 Installation Guide

ASP-MG2240. Amplified Sound Masking System

2-port KVM Switch with Dual VGA - USB 2.0

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

PROFESSIONAL AUDIO SYSTEMS

HDMI to CAT5 Extender W/ Optional Repeater Functionality and Audio 1080p / 1920x1080

CPCI-16HSDI. 16-Bit, Six-Channel Sigma-Delta Analog Input Board. With 1.1 MSPS Sample Rate per Channel, and Two Independent Clocks.

SmartAudio: SSA Feature Summary

SONAMP DSP AMPLIFIERS

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

Ceiling Microphone Array INSTALLATION MANUAL. VoIPon Tel: +44 (0) Fax: +44 (0)

PRELIMINARY DATA SHEET AM 1 AUTOMIXER SHIPS APRIL 2010

VoIP Gateway High Performance VoIP Gateway Solution

User Manual. Please read this manual carefully before using the Phoenix Octopus

PHS Series. PowerHUBB Node - Satellite

AMP Watt Audio Amplifier with RS-232 and IR Control. User s Manual CUSTOMER SUPPORT INFORMATION

Description Front View of SSC-0025 Rear View of SSC-0025

IP7 -SS40. IP Paging Amplifier. Reference Manual

IP Desktop Intercom Stations 12 NIB 001 Series

PC104P-16AO20 20-Channel 16-Bit High-Speed Analog Output PC104-Plus Board With 440,000 Samples per Second per Channel, and Simultaneous Clocking

EMS10 - EMS50. Cameo specification sheet. Product Description

JPEG 2000 Digital Cinema Grade Video over IP Encoder, PoE, HDMI

TOA Net Price List PROFESSIONAL USER

Data Sheet. V910 Impact-Resistant IP and Analog Camera Dome Series. Durable Construction and Easy Installation

Product information AD-850

ControlSpace ESP-00 Series II TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications


IP Speaker System. Users Guide

Description. SmartControl with PoE: SSC-P008. Feature Summary. Rear View of SSC-P008

HDMI and USB over IP Distribution Kit p

TOPCAT ACCESS SPECIFICATIONS

ZCM-V2+T. PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T

PHM Series. PowerHUBB Node - Master/Control

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

IP-DM. IP Wall Mount LCD with Microphone

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

14 USB devices or 3 USB hubs with 11 USB devices. Input: 100/240 V AC, Hz, 600 ma maximum Output: 5 V DC, 3 A

PMC-16AI Channel, 16-Bit Analog Input PMC Board. With 500 KSPS Input Conversion Rate. Features Include: Applications Include:

ex-s1110-xt Gigabit Ethernet Extenders

LA8 Amplified Controller

CONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES

EX-UBT AVB/USB EXPANDER OPERATION MANUAL

LD5400T Thunderbolt 3 Dock with K-Fob Smart Lock

LCD Central Drive Remote Driver Pathway Custom Series

PCI-16HSDI: 16-Bit, Six-Channel Sigma-Delta Analog Input PMC Board. With 1.1 MSPS Sample Rate per Channel, and Two Independent Clocks

TL-CAV-01 Classroom & Meeting Room Kit

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

IP-SM-72. PoE+ Indoor IP Endpoint Speaker with Microphone and Analog Transformer & Switch

IP-HVP. PoE+ Vandal and Weather Resistant Wall Mount IP Speaker

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

FOR THE LOVE OF SOUND

Minimal Proprietary Compression Video Over IP Encoder

9000M2 SERIES MODULAR DIGITAL MATRIX MIXER AND MIXER/AMPLIFIERS H IGHLIGHTS

SM 3 SPEEDMOUNT COMPACT FULL-RANGE SURFACE MOUNT SPEAKERS SPEAKERS. Patented, concealed mounting system

PMC-12AI Channel, 12-Bit Analog Input PMC Board. With 1,500 KSPS Input Conversion Rate

Yealink VC Microphone Profolio. Video Conferencing Phone VCP41. Key Features and Benefits

KD-AMP220. Operating Instructions. 2 Channel 20 Watt Per Channel, Compact Digital Audio Amplifier

Transcription:

DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE The TCM-1 is an AVB ceiling microphone for use in Tesira systems. Comprising a pendant microphone and plenum box, each microphone includes Beamtracking technology with three 120-degree zones, providing full 360-degree coverage of the meeting space. The TCM-1 microphone actively tracks and intelligently mixes conversations from around the table, allowing far-end conference participants to experience the conversation naturally. The Tesira TCM-1 comes with its own digital signal processing module for Beamtracking, and each plenum box comes with an additional RJ-45 connector for daisy-chain connections. A maximum of three microphones are permitted per daisy chain (one TCM-1 or TCM-1A required, plus up to two TCM-1EX). The TCM-1 is well suited for a variety of room types and sizes that require high-quality audio solutions, such as conference rooms or council chambers. FEATURES Beamtracking technology actively tracks and intelligently mixes conversations Three 120-degree zones for 360 degrees of coverage Plenum box includes DSP for Beamtracking LED mute status indicator User-adjustable mic height Easy single-cable installation process Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces Additional RJ-45 for daisy-chain connection to a TCM-1EX microphone (maximum of three mics per daisy chain; one TCM-1 or TCM-1A and two TCM-1EX) CE marked, UL listed, and RoHS compliant Covered by Biamp Systems five-year warranty ARCHITECTS & ENGINEERS SPECIFICATIONS The Beamtracking ceiling microphone shall be designed exclusively for use with Biamp Tesira systems. The Beamtracking ceiling microphone shall be comprised of a pendant microphone and plenum box. The Beamtracking ceiling microphone shall utilize an AVB/TSN network via an RJ-45 connector for audio networking as well as software configuration and control. The Beamtracking ceiling microphone shall contain eight-element microphones, and shall provide three 120-degree zones for 360 degrees of coverage. The Beamtracking ceiling microphone shall offer multidirectional beamforming and automatic signal tracking capabilities. The Beamtracking technology shall operate in conjunction with acoustic echo cancellation technology (AEC) in accordance with U.S. Patent 9659576. The signal processing of the Beamtracking ceiling microphone shall be configurable via the Tesira design software, including but not limited to: signal routing and mixing, equalization, filtering, dynamics, and delay, as well as control, monitoring, and diagnostic tools. The Beamtracking ceiling microphone shall offer simple installation and microphone height adjustment, and shall be mountable on a ceiling tile or in open-ceiling environments. The Beamtracking ceiling microphone shall be powered by Power-over- Ethernet (IEEE 802.3at Class 3). The Beamtracking ceiling microphone shall be suitable for use in air handling spaces in accordance with UL 2043, and shall provide a second RJ-45 connector to allow up to two additional expander TCM-1EX microphones to be daisychained together. The Beamtracking ceiling microphone shall be CE marked, UL listed, and compliant with the RoHS directive. Warranty shall be five years. The Beamtracking ceiling microphone shall be Tesira TCM-1.

TESIRA TCM-1 SPECIFICATIONS PENDANT MICROPHONE Microphone Technology: Frequency Response (150 Hz - 16 khz): Polar Pattern: Sensitivity (94dB SPL, 1kHz): Maximum SPL (at 0.5% THD): Dynamic Range (THD+N < 10%): Connector: 0 0 o BEAMFORMING RANGE Polar pattern shown at 1kHz Zone 1 0 o 0 db 30 o 8-Element Digital Array 60 o ± 3dB Beamformed > 70dB 106dB 92dB, A-Weighted Mute Indicator (Green/Red LED) Custom 2-pin (cable length 4.9 feet [1.5 meters]) 0.4 lbs (0.2 kg) PLENUM BOX Two RJ-45: one between TCM-1 plenum box and switch, the other between TCM-1 plenum box and additional TCM-1EX plenum box; 2-pin 3.5 mm Phoenix connector to TCM-1 microphone Power: IEEE 802.3at Class 3 Max Distance Between Devices: Power Indicator (Green/Yellow/Red LED) 330 feet (100 meters) from switch to TCM-1 plenum box; 33 feet (10 meters) for daisy-chained connections between TCM plenum boxes 7 inches (178 mm) 7.125 inches (181 mm) 2.4 lbs (1.1 kg) Environmental Ambient Operating Temperature Range: 32-104 F (0-40 C) Humidity: 0-95% relative humidity (non-condensing) Altitude: 0-10,000 ft (0-3000m) MSL Compliance: FCC Part 15B (USA) CE marked (Europe) UL and C-UL listed (USA and Canada) RoHS Directive (Europe) Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces 0 o 90 o Zone 3 0 o 120 o Zone 2 150 o 0 db 150 o 180 o TESDS-362-1804-EN-R1

DATA SHEET TESIRA TCM-1A AVB BEAMTRACKING CEILING MICROPHONE WITH POE+ AMPLIFIER The TCM-1A is an AVB ceiling microphone and PoE+ amplifier for use in Tesira systems. Comprising a pendant microphone and plenum box, each microphone includes Beamtracking technology with three 120-degree zones, providing full 360-degree coverage of the meeting space. The TCM-1A microphone actively tracks and intelligently mixes conversations from around the table, allowing far-end conference participants to experience the conversation naturally. The 2-channel PoE+ amplifier includes an internal limiter, selectable power, and is also capable of operating in a burst mode to handle peak signals, providing up to 40 watts (4Ω load) or 30 watts (8Ω load) per channel. The TCM-1A comes with its own digital signal processing module for Beamtracking, and each plenum box comes with an additional RJ-45 connector for daisy-chain connections. A maximum of three microphones are permitted per daisy chain (one TCM-1 or TCM-1A required, plus up to two TCM-1EX). The TCM-1A is well suited for a variety of room types and sizes that require high-quality audio solutions, such as conference rooms or council chambers. FEATURES Beamtracking technology actively tracks and intelligently mixes conversations Plenum box includes DSP for Beamtracking and a PoE+ amplifier Two channels; 4 watts continuous power per channel Burst mode to handle peak signals in accordance with ANSI/ CTA-2006-B; supports up to 40 watts (4Ω load) or 30 watts (8Ω load) per channel Software-selectable power vs. channel count Includes internal limiter function Three 120-degree zones for 360 degrees of coverage LED mute status indicator User-adjustable mic height Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces Additional RJ-45 for daisy-chain connection to a TCM-1EX microphone (maximum of three mics per daisy chain; one TCM-1 or TCM-1A and two TCM-1EX) CE marked, UL listed, and RoHS compliant Covered by Biamp Systems five-year warranty ARCHITECTS & ENGINEERS SPECIFICATIONS The Beamtracking ceiling microphone shall be designed exclusively for use with Biamp Tesira systems. The Beamtracking ceiling microphone shall be comprised of a pendant microphone and plenum box. The Beamtracking ceiling microphone shall utilize an AVB/ TSN network via an RJ-45 connector for audio networking as well as software configuration and control. The Beamtracking ceiling microphone shall contain eight-element microphones, and shall provide three 120-degree zones for 360 degrees of coverage. The Beamtracking ceiling microphone shall offer multidirectional beamforming and automatic signal tracking capabilities. The Beamtracking technology shall operate in conjunction with acoustic echo cancellation technology (AEC) in accordance with U.S. Patent 9659576. The signal processing of the Beamtracking ceiling microphone shall be configurable via the Tesira design software, including but not limited to: signal routing and mixing, equalization, filtering, dynamics, and delay, as well as control, monitoring, and diagnostic tools. The plenum box of the Beamtracking ceiling microphone shall provide two output channels of 4 watts of continuous power per channel into a 4-ohm load and an 8-ohm load. The plenum box of the Beamtracking ceiling microphone shall also provide burst power output of 40 watts per channel into a 4-ohm load, and 30 watts per channel into an 8-ohm load in accordance with ANSI/CTA-2006-B. The Beamtracking ceiling microphone shall offer simple installation and microphone height adjustment, and shall be mountable on a ceiling tile or in open-ceiling environments. The Beamtracking ceiling microphone shall be powered by Power-over-Ethernet (IEEE 802.3at Class 4). The Beamtracking ceiling microphone shall be suitable for use in air handling spaces in accordance with UL 2043, and shall provide a second RJ-45 connector to allow up to two additional expander TCM-1EX microphones to be daisy-chained together. The Beamtracking ceiling microphone shall be CE marked, UL listed, and compliant with the RoHS directive. Warranty shall be five years. The Beamtracking ceiling microphone shall be Tesira TCM-1A.

TESIRA TCM-1A SPECIFICATIONS PENDANT MICROPHONE Microphone Technology: Frequency Response (150 Hz - 16 khz): Polar Pattern: Sensitivity (94dB SPL, 1kHz): Maximum SPL (at 0.5% THD): Dynamic Range (THD+N < 10%): Connector: 0 o 0 0 o BEAMFORMING RANGE Polar pattern shown at 1kHz Zone 1 0 o 0 db 30 o 8-Element Digital Array 60 o 90 o ± 3dB Beamformed > 70dB 106dB 92dB, A-Weighted Mute Indicator (Green/Red LED) Custom 2-pin (cable length 4.9 feet [1.5 meters]) 0.4 lbs (0.2 kg) PLENUM BOX Two RJ-45: one between TCM-1A plenum box and switch, the other between TCM-1A plenum box and additional TCM-1EX plenum box; 2-pin 3.5 mm Phoenix connector to TCM-1A microphone Power: IEEE 802.3at Class 4 Max Distance Between Devices: Power Indicator (Green/Yellow/Red LED) Amp Status Indicator (Green/Yellow/Red LED) 330 feet (100 meters) from switch to TCM-1A plenum box; 33 feet (10 meters) for daisy-chained connections between TCM plenum boxes 7 inches (178 mm) 7.125 inches (181 mm) 2.4 lbs (1.1 kg) Environmental Ambient Operating Temperature Range: 32-104 F (0-40 C) Humidity: 0-95% relative humidity (non-condensing) Altitude: 0-10,000 ft (0-3000m) MSL Compliance: FCC Part 15B (USA) CE marked (Europe) UL and C-UL listed (USA and Canada) RoHS Directive (Europe) Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces AMPLIFIER Zone 3 0 o 150 o 0 db 150 o 180 o 120 o Zone 2 Number of Channels: 2 4-pin 5.08 mm Phoenix connectors Amplifier Topology: Class D Burst Power Output (per ANSI/CTA-2006-B @ 1kHz): 4Ω (per channel): 8Ω (per channel): 40W 30W Continuous Power Output: Single Channel Driven, (4Ω, 8Ω): Dual Channel Driven (4Ω, 8Ω): 8W 4W THD+N (20Hz-20kHz, at continuous power): < 0.3% Frequency Response (20Hz-20kHz): ± 1dB Dynamic Range (20Hz-20kHz BW): > 85dB Minimum Operational Load: 4Ω Intermodulation distortion (SMPTE): < 0.3% Cross Talk (channel to channel @ 1kHz): < -90dB TESDS-363-1804-EN-R1

DATA SHEET TESIRA TCM-1EX EXPANSION AVB BEAMTRACKING CEILING MICROPHONE The TCM-1EX is an expansion AVB ceiling microphone for use in Tesira systems. Comprising a pendant microphone and plenum box, each microphone includes Beamtracking technology with three 120-degree zones, providing full 360-degree coverage of the meeting space. The TCM-1EX microphone actively tracks and intelligently mixes conversations from around the table, allowing far-end conference participants to experience the conversation naturally. The Tesira TCM-1EX is intended to be used as a second and third microphone in conjunction with a TCM-1 or TCM-1A; it cannot operate as a standalone device. Each plenum box comes with an additional RJ-45 connector for daisy-chain connections. A maximum of three microphones are permitted per daisy chain (one TCM-1 or TCM-1A required, plus up to two TCM-1EX). The TCM-1EX is well suited for a variety of room types and sizes that require high-quality audio solutions, such as conference rooms or council chambers. FEATURES Must be used with a Tesira TCM-1 or TCM-1A microphone Beamtracking technology actively tracks and intelligently mixes conversations Three 120-degree zones for 360 degrees of coverage LED mute status indicator User-adjustable mic height Easy single-cable installation process Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces Additional RJ-45 for daisy-chain connection to another TCM-1EX microphone (maximum of three mics per daisy chain; one TCM-1 or TCM-1A and two TCM-1EX) CE marked, UL listed, and RoHS compliant Covered by Biamp Systems five-year warranty

ARCHITECTS & ENGINEERS SPECIFICATIONS The expansion Beamtracking ceiling microphone shall be designed exclusively for use with Biamp Tesira systems. The expansion Beamtracking ceiling microphone shall be comprised of a pendant microphone and plenum box. The expansion Beamtracking ceiling microphone shall utilize a proprietary digital protocol via an RJ-45 connector for audio networking with a TCM-1 or TCM-1A Beamtracking ceiling microphone. The expansion Beamtracking ceiling microphone shall contain eight-element microphones, and shall provide three 120-degree zones for 360 degrees of coverage. The expansion Beamtracking ceiling microphone shall offer multidirectional beamforming and automatic signal tracking capabilities. The Beamtracking technology shall operate in conjunction with acoustic echo cancellation technology (AEC) in accordance with U.S. Patent 9659576. The signal processing of the expansion Beamtracking ceiling microphone shall be configurable via the Tesira design software, including but not limited to: signal routing and mixing, equalization, filtering, dynamics, and delay, as well as control, monitoring, and diagnostic tools. The expansion Beamtracking ceiling microphone shall offer simple installation and microphone height adjustment, and shall be mountable on a ceiling tile or in open-ceiling environments. The expansion Beamtracking ceiling microphone shall be suitable for use in air handling spaces in accordance with UL 2043, and shall provide a second RJ-45 connector to allow up to three microphones to be daisychained together. The expansion Beamtracking ceiling microphone shall be CE marked, UL listed, and compliant with the RoHS directive. Warranty shall be five years. The expansion Beamtracking ceiling microphone shall be Tesira TCM-1EX. TESIRA TCM-1EX SPECIFICATIONS PENDANT MICROPHONE Microphone Technology: Frequency Response (150 Hz - 16 khz): Polar Pattern: Sensitivity (94dB SPL, 1kHz): Maximum SPL (at 0.5% THD): Dynamic Range (THD+N < 10%): Connector: : 0 0 o BEAMFORMING RANGE Polar pattern shown at 1kHz Zone 1 0 o 0 db 30 o 8-Element Digital Array 60 o ± 3dB Beamformed > 70dB 106dB 92 db, A-Weighted Mute Indicator (Green/Red LED) Custom 2-pin (cable length 4.9 feet [1.5 meters]) 0.4 lbs (0.2 kg) PLENUM BOX Power: Max Distance Between Devices: : Two RJ-45: one between TCM-1EX plenum box and TCM-1 or TCM-1A, the other between TCM-1EX plenum box and additional TCM-1EX plenum box; 2-pin 3.5 mm Phoenix connector to TCM-1EX microphone Link Indicator (Green LED) 33 feet (10 meters) between TCM plenum boxes 4 inches (102 mm) 5.25 inches (133 mm) 0.8 lbs (0.4 kg) Environmental: Ambient Operating Temperature Range: 32-104 F (0-40 C) Humidity: 0-95% relative humidity (non-condensing) Altitude: 0-10,000 ft (0-3000m) MSL Compliance: FCC Part 15B (USA) CE marked (Europe) UL and C-UL listed (USA and Canada) RoHS Directive (Europe) Evaluated to the requirements of UL 2043 and is suitable for use in air handling spaces 0 o 90 o Zone 3 0 o 120 o Zone 2 150 o 0 db 150 o 180 o TESDS-364-1804-EN-R1