CleaveMeter TM. Interferometric fiber end-face inspection systems for research, development and production.

Similar documents
SPECIALIZED FIBER OPTIC ENDFACE TESTING

SPECIALIZED FIBER OPTIC ENDFACE TESTING

ZX-1 Array Plus Zoom Interferometer

Phenom TM Pro Suite. The ultimate application software solution. Specification Sheet

Measuring range X / Y mm 100 / / /170 Z travel mm 200 / 400** Max. table load kg 20

Calibration of a portable interferometer for fiber optic connector endface measurements

Mu lt i s p e c t r a l

A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES

Complete 3D measurement solution

FIBRE OPTIC FUSION SPLICING EQUIPMENT SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

Eric Lindmark, Ph.D.

features and benefits

4. Recommended alignment procedure:

A U T O C O L L I M A T O R S

Contour LS-K Optical Surface Profiler

features and benefits

1. Summary of configurations for end face geometry and measurement conditions. Configurations for End Face Geometry

SPECIALTY FUSION SPLICING SYSTEMS. ARCMaster FSM-100M/ P ARCMaster FSM-100M+/ P+ LZM-100 LAZERMaster

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A MICHELSON INTERFEROMETER. TECHSPEC Optical Cage System

FSM-30PF SPECIFICATIONS FOR FIBER FUSION SPLICER FOR HIGH TENSILE STRENGTH SPLICING 1. GENERAL

PrismMaster. Ultra Accurate and Fully Automated Prisms and Polygons Measurement

SIMULATION AND VISUALIZATION IN THE EDUCATION OF COHERENT OPTICS

FUSION SPLICING SYSTEMS. Fusion Splicers Cleavers Tools & Supplies Software

How to Measure Wedge. Purpose. Introduction. Tools Needed

Table of Contents. Section Description Page

Compact non-contact 3D surface profiler

QUALITY ASSURANCE OF MULTIFIBER CONNECTORS

High Precision Fusion Splicer

Two 2 MP orthogonal video microscopes equipped with double sided telecentric lenses and LED backlighting

Highly Efficient Assembly of Lenses with. OptiCentric and OptiCentric Cementing

D-SCOPE The indispensable analysis tool for all diamonds

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

MICHELSON S INTERFEROMETER

Core-Aligning Fusion Splicers

7.3 Refractive Index Profiling of Fibers and Fusion Splices

TAGARNO. TAGARNO MEDTECH 320 when quality is paramount

Discover the new world of handheld digital microscopy

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control

AV6471A FTTH OPTICAL FIBER FUSION SPLICER

VibroFlex Compact Compactness meets versatility Preliminary datasheet. VibroFlex Compact

Compact 3D optical surface profiler

3SAE Large Diameter Splicing (LDS) System

ION BEAM MILLING SYSTEM FOR TEM, SEM AND LM PREPARATION. Leica EM RES102

Chapter 82 Example and Supplementary Problems

LEICA MANUFACTURING. The art of lens production.

INSPECTION TOOLS EYL10X. 10X Eye Loupe

FUSION- Modular Interchangeable Lens System

Quality control for the foil industry -the modular solutions-

Rugged and waterproof, plus high-power telescope with superior Nikon optics

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

OPTICAL FIBER SOLUTIONS

PRESETTER SP40. Pesaro, September 2013

Hand-held Fully Featured Eddy Current Flaw Detector ET NDE

Visualiner 3D Wheel Aligners

Cellcheck CIL-USB for solar industry

ksa MOS Ultra-Scan Performance Test Data

SURFACE TEXTURE EFFECT ON LUSTER OF ANODIZED ALUMINUM USING 3D PROFILOMETRY

ECEN 4606, UNDERGRADUATE OPTICS LAB

NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS

LEEDS FORENSIC SYSTEMS

SURFACE FINISH INSPECTION OF WOOD USING 3D PROFILOMETRY

Specification Sheet FPI lab

Optics for nonlinear microscopy

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

MURA & DEFECT DETECTION WITH TrueTest

Optical Topography Measurement of Patterned Wafers

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

Rodenstock Products Photo Optics / Digital Imaging

dimensional metrology

ECEN 4606, UNDERGRADUATE OPTICS LAB. Lab 12: Fiber optics

+ + Swift F1+ is a way on future splicers.

Video Endoscopic Metrology for Pipeline Welding

Discover the new world of handheld digital microscopy

All-In-One Fusion Splicer

5th Edition. Optem FUSION. Extreme Micro-Imaging Versatility

3D-Analysis of Microstructures with Confocal Laser Scanning Microscopy

S178A. Hand-Held Core-Alignment Fusion Splicer

What is Frequency Domain Analysis?

3M Fibrlok Optical Splice System

Peak measuring loupes

MarShaft. MarShaft SCOPE 250 plus

VISION MEASURING SYSTEMS

Features included in isolution Lite, i-solution, isolution DT

Operating Microscope OM-18. A i m i n g a t n e w l e v e l s i n q u a l i t y

TELECENTRIC LENSES INNOVATION STARTS HERE... Global Design & Support Rapid Prototyping Volume Manufacturing & Pricing

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

Field Splice Systems Fusion Splicers, Accessories, Tools and Consumables

TELECENTRIC LENSES INNOVATION STARTS HERE... Global Design & Support Rapid Prototyping Volume Manufacturing & Pricing

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

Related topics Interference, wavelength, refractive index, speed of light, phase, virtuallight source.

SPECIFICATIONS FOR RIBBON FIBER FUSION SPLICER 70R TENTATIVE

Determination and compensation of the reference surface from redundant sets of surface measurements

Full-HD (1080p) digital microscope. Stunning full-hd 1080p/60fps live video image quality

Leica DISTO D1 Laser Distance Meter

SANXO-Scope HD. Technical Description SANXO-SCOPE HD DIGITAL VIDEO MICROSCOPE INSPECTION AND MEASURING STATION ID 2017Q1

Light Tec Scattering measurements guideline

VEO. The bench mark in video magnifiers

FIXED FOCAL LENGTH LENSES

CLEMEX intelligent microscopy

SPECIFICATIONS FOR SINGLE FIBER FUSION SPLICER 19S TENTATIVE

Transcription:

CleaveMeter TM Interferometric fiber end-face inspection systems for research, development and production Product catalogue NYFORS is a trademark of Nyfors Teknologi AB. Edition 2013 January.

Interferometric fiber end-face inspection systems for research, development and production The CleaveMeter TM interferometer system is designed for inspecting the surface quality, flatness and perpendicularity of cleaved and polished optical fibers. Complementing the NYFORS AutoCleaver TM line of automatic fiber cleavers with process documentation and optimization functionality, it allows every cleave to be individually inspected and evaluated even in high volume production environments. In research, development and demanding production operations, the sophisticated analysis software provides valuable input when working with difficult to cleave speciality fibers with complicated internal structures, such as polarization maintaining and microstructured fibers. Two different versions are available the standard CleaveMeter 2 TM and the phase-shifting, CleaveMeter 3D TM high precision interferometer with three dimensional surface reconstruction capability. Features High precision optics. The built-in megapixel camera with digital zoom and the high quality optics together combine to produce sharp images and distinct, high contrast fringe patterns with very little aberration. This makes it easy for the operator to quickly estimate the cleave angle and surface quality from an image that show every detail of the fiber endface surface. Easy to use software available in two different versions standard and premium. Standard software features includes support for automatic cleave angle measurements with in-picture presentation of results and the ability to log information, save and load images to and from files with user defined markers at points of interest. The premium software package includes functionality for measurements of plane angles and fiber diameters as well as compensation for adaptor plate angular error for increased measurement precision. Three dimensional surface reconstruction capability. Using phase-shifting interferometry, the CleaveMeter 3D TM combines the information from several different interferograms to create high resolution, three dimensional images of the cleaved fiber end-face surface. This facilitates easier visual inspection of the cleave result, and more precise measurements of important end-face properties such as surface flatness and cleave angle. Optional pass/fail indication of cleave angle help ensure that consistent quality is maintained over long periods of continuous cleaver operation. Measurement of cleave angle with a NYFORS CleaveMeter TM. Each fringe over the user defined measurement line is indicated with a coloured dot. In this case the measurement result is seven fringes over 345.8 μm, corresponding to a cleave angle of about 0.33. User friendly and ergonomic design. Designed for full operator skill independence, the system accepts fiber holders from the major splicer manufacturers as well as NYFORS automatic fiber cleavers. This makes it easy to move the fiber from cleaver to interferometer for analysis, and then on to the splicer in a production environment. Small and compact, the CleaveMeter TM comes in a bench-top design that connects to the USB port of a PC running the host application. NYFORS is a trademark of Nyfors Teknologi AB. Edition 2013 January.

Interferometric fiber end-face inspection systems for research, development and production Reconstructed fiber end-face in 3D-mode (with height scaled 65 times to bring out surface irregularities and facilitate easier analysis). The sensitivity of the measurements and the level of detail is such that objects as small as a few nanometers in height, dust particles and other minute surface. Screenshot showing the pointwise slope of a fiber end-face, a useful feature for spotting small scale irregularities and examining crack propagation behaviour. NYFORS is a trademark of Nyfors Teknologi AB. Edition 2013 January.

CleaveMeter 3D TM NEW Optical fiber end-face interferometer with three-dimensional surface topography reconstruction Full resolution surface reconstruction 2D view of surface topography and pointwise slope 3D view of surface topography with camera and lighting control Extremely accurate, operator independent measurements of cleave angle and surface flatness over arbitrary diameters Optional pass/fail indication of cleave angle for fast operation in production environments The CleaveMeter 3D TM is a phase-shifting Michelson interferometer for non-contact end-face inspection of cleaved and polished optical fibers with cladding diameters up to 1200 µm. Designed for both production and research applications, this comprehensive fiber optic testing system combines full resolution, three-dimensional surface topography reconstruction and mapping with automated, operator independent measurements of cleave angle and surface flatness in a small, lightweight benchtop unit. When used in the 3D-mode, the surface topography is reconstructed from the fringe pattern and presented graphically as a three-dimensional image of the fiber end. By rotating the image and adjusting the scale and contrast, the surface quality and cleave angle at different points can be analysed in close detail, allowing for a more comprehensive understanding and accurate interpretation of the data and the cleaving process. While this capability is always important to cleave quality analysis, it can be even especially helpful when analysing cleaving of fibers with complicated structures such as polarization maintaining fibers, or microstructured fibers. Information on surface topography can also be saved to a file for further analysis using third party software. Extremely accurate measurements of both cleave angle and surface flatness over arbitrary diameters can be performed on the reconstructed end-face surface. These measurements are carried out automatically, with Reconstructed end-face surface of a cleaved 400 µm fiber (center cleave angle about 0.16 ), with height scaled three hundred times to bring out surface irregularities and facilitate easier cleave quality analysis. CleaveMeter 3D is a trademark of Nyfors Teknologi AB. Edition 2013 Jan.

Optical fiber end-face interferometer with three-dimensional surface topography reconstruction Reconstructed end-face surface of a cleaved 400 µm fiber (center cleave angle about 0.16 ), with height scaled three hundred times to bring out surface irregularities and facilitate easier cleave quality analysis. To the right a detail of the same image, showing a dust particle or other surface contamination with a height of about 15 nm illustrating the level of detail and sensitivity of the measurements. full operator independence. This makes the system well suited not only for detailed cleave quality analysis in laboratory environments, but also for close production monitoring where software features such as optional pass/fail indication of cleave angle help ensure that consistent cleave quality is maintained over long periods of continuous cleaver operation. In addition to cleave angle measurements, the system can also be used to measure a number of other properties such as plane angles, fiber diameters and the distance between different points. The software allows the user to view the point-wise slope across the whole fiber end-face, a very useful tool for spotting small scale irregularities and crack propagation behaviour. Adaptor plates are available for both perpendicular and angled cleave analysis. The mechanical design is compatible with all NYFORS automatic fiber cleavers and accepts the fiber holders used with those machines as well as those of major splicer manufacturers. Custom made adaptor plates are available upon request. The CleaveMeter 3D TM comes in a small, ergonomic bench-top design and connects to the USB port of a PC running the host application. TECHNICAL DATA Fiber cladding Fiber coating Camera resolution Image scale Image file format PC connection Power supply Dimensions Weight CLEAVE ANGLE ACCURACY Absolute accuracy** 125 1200 μm* 250 1500 μm 1280 1024 pixels 1.25 μm per pixel 8-bit JPEG, PNG, TIFF, BMP / 24-bit BMP for surface topography USB 2.0 port Through USB port 97 mm (W) 179 mm (D) 142 mm (H) 1.6 kg Relative accuracy 5 % NYFORS part number: 30100013 0.01 standard deviation Included in delivery: CleaveMeter 3D TM unit, PC Software, USB interface cable, Manual and Tools. *Fiber-specific adaptor plates required. ** This level of accuracy requires the adaptor plate angle error to be measured and compensated for on each individual CleaveMeter TM the holder is used with. For more information about system accuracy, please contact us at info@nyfors.com. CleaveMeter 3D is a trademark of Nyfors Teknologi AB. Edition 2013 Jan.

Selection Guide Matrix Fiber specific adaptor plates are required to clamp and align the fiber to the interferometer optics. They are not included in delivery and should be ordered separately. Adaptor plates are available for use with NYFORS automatic fiber cleavers and fiber holders from the major splicer manufacturers. Below you find a selection of the most common types and dimensions. NYFORS generic adaptor plates are compatible with NYFORS LD fiber clamps and Ericsson FSU-clamps. Select Adaptor Plate to match the fiber cladding diameter and Angle Adaptor Plate (optional) to match the fiber tilt angle. ARTICLE Adaptor Plate Cladding diameter Article number Article Description Article Type 115-210 μm 30100001 Adaptor plate, FJK, 115-210 μm Fujikura/AFL 200-529 μm 30100002 Adaptor plate, FJK, 200-529 μm Fujikura/AFL 510-800 μm 30100003 Adaptor plate, FJK, 510-800 μm Fujikura/AFL 800-1200 μm 30100004 Adaptor plate, FJK, 800-1200 μm Fujikura/AFL Customer specified 30100007 Adaptor plate, NYFORS, Generic NYFORS, Generic NYFORS/Ericsson Angle Adaptor Plate Fiber tilt angle Article number Article Description 15 30100008 Angle adaptor plate, 15 degrees 8 30100009 Angle adaptor plate, 8 degrees Customer specified 30100010 Angle adaptor plate, Generic

CleaveMeter 2 TM NEW Optical fiber end-face interferometer Sharp fringe patterns Flat and angled cleave measurements Operator skill independent for fast operation Accepts fibers with claddings from 125 µm up to 1200 µm Accepts fiber holders of major splicer manufacturers Adaptor plate angle error measurement and compensation (Premium software) Plane angle and three-point fiber diameter measurement (Premium software) The CleaveMeter 2 TM is a non-contact interferometer designed for inspecting the end-faces of cleaved and polished optical fibers with cladding diameters of 125 µm to 1200 µm. It gives immediate information on important endface properties such as flatness, perpendicularity, hackles and dust. Sampling tests as well as continuous process documentation can be carried out both easily and quickly, making this an ideal instrument for cleaver inspection and optimization. The optical system is based on a high-end camera with true megapixel resolution and very high sensitivity, yielding excellent image quality at high frame rates and high magnification. Switching between low and high magnification is software-controlled. High-precision optics guarantees sharp and clear images and fringe patterns with very little aberration. The CleaveMeter 2 TM comes with user friendly and efficient software available in two different versions standard and premium. Standard software features include cleave angle measurements with in-picture presentation of results, user-defined markers at points of interest, pseudo-colour mode for better contrast and the ability to log information, save and load images to and from files. The premium software package includes support for measurement of plane angles and fiber diameters as well as compensation for adaptor plate angle error for increased accuracy. The CleaveMeter 2 TM comes in a small ergonomic, bench-top design and connects to the USB port of a PC running the host application. TECHNICAL DATA Fiber cladding Fiber coating Camera resolution Image scale Image file format PC connection Power supply Dimensions Weight CLEAVE ANGLE ACCURACY Absolute accuracy Relative accuracy NYFORS part number: 30100011-12 125 1200 μm* 250 1500 μm 1280 1024 pixels 1.25 μm per pixel 8-bit JPEG, PNG, TIFF, BMP USB 2.0 port Through USB port 97 mm (W) 179 mm (D) 142 mm (H) 1.6 kg 0.15/0.03 degrees** 20 % (125-199 µm) 10 % (200-529 µm) 5 % (530-1200 µm) Included in delivery: CleaveMeter 2 TM unit, PC Software, USB interface cable, Manual and Tools. *Fiber-specific adaptor plates required. ** This level of accuracy requires adaptor plate angle errors to be measured/compensated on the individual CleaveMeters they are used with (Premium software only). For more information about system accuracy, please contact us at info@nyfors.com. CleaveMeter 2 is a trademark of Nyfors Teknologi AB. Edition 2013 Jan.

Selection Guide Matrix Fiber specific adaptor plates are required to clamp and align the fiber to the interferometer optics. They are not included in delivery and should be ordered separately. Adaptor plates are available for use with NYFORS automatic fiber cleavers and fiber holders from the major splicer manufacturers. Below you find a selection of the most common types and dimensions. NYFORS generic adaptor plates are compatible with NYFORS LD fiber clamps and Ericsson FSU-clamps. Select Adaptor Plate to match the fiber cladding diameter and Angle Adaptor Plate (optional) to match the fiber tilt angle. ARTICLE Adaptor Plate Cladding diameter Article number Article Description Article Type 115-210 μm 30100001 Adaptor plate, FJK, 115-210 μm Fujikura/AFL 200-529 μm 30100002 Adaptor plate, FJK, 200-529 μm Fujikura/AFL 510-800 μm 30100003 Adaptor plate, FJK, 510-800 μm Fujikura/AFL 800-1200 μm 30100004 Adaptor plate, FJK, 800-1200 μm Fujikura/AFL Customer specified 30100007 Adaptor plate, NYFORS, Generic NYFORS, Generic NYFORS/Ericsson Angle Adaptor Plate Fiber tilt angle Article number Article Description 15 30100008 Angle adaptor plate, 15 degrees 8 30100009 Angle adaptor plate, 8 degrees Customer specified 30100010 Angle adaptor plate, Generic