Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Similar documents
Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc.

TABLE OF CONTENTS. Introduction... 1

Digital Lighting Systems, Inc.

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA+ Series Rotary Level Indicator

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Digital Lighting Systems, Inc PROTOCOL. Lighting control system. Hardware Installation manual

Tempco Instruction Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Digital Lighting Systems, Inc Protocol Dimming System PROTOCOL. System Planning & Hardware INSTALLER MANUAL. PHM Rev. C - 8/02

WR-5e Remote Control

Basketball Shot Clock Set LX2180 Manual

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

SCD96 DMX Output Interface. Installation guide

iconverter 2-Module Power Chassis

User s Guide. POWERVAR Single Phase Power Conditioners

S66 Series Electronic Fan Speed Control

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

DCM Digital Control Modules

Ashly WR-5 Remote Control

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

Hybrid AC Driver [GCNC-1110]

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

OPERATIONS MANUAL PCM-I/O48

OWNER'S MANUAL DIMMERMASTER 1224 DIGITAL DIMMER

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

KBMG MULTI-SPEED BOARD

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

OP8/16 Optoisolated Digital Input Board User's Manual

PS8 - II. Professional Power Sequencer. User s Manual

RTD SAMPLER OPERATOR S MANUAL

Kramer Electronics, Ltd. USER MANUAL. Model: VS-4x4FW. 4x4 FireWire Switcher

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

XPWR104HR High efficiency PC/104 power supply module User s Manual

Resolver to Digital Expansion Board

Dim levels for each system output may be controlled by any of the following methods:

EMS Electrical Management System

Expandable Power Systems

P216 Series Condenser Fan Speed Controller

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

EMS Electrical Management System

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

SMD Series Integrated Stepper Driver and Motor Revision 1.3

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Model DMX8DIM Installation and Operations Manual

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

VPWR104HR High efficiency PC/104 power supply module User s Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

ETC Installation Guide

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Kramer Electronics, Ltd.

USER MANUAL. Kramer Electronics, Ltd. Models:

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Model: RK-1

AEXX-349 SERIES REMOTE DISPLAYS

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top)

Kramer Electronics, Ltd. USER MANUAL. Model: VM-4HDCP. 1:4 DVI Distributor

SAVE THESE INSTRUCTIONS

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

THE CTB08D LIGHT CONTOLLER

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Progressive Industries, Inc. EMS Electrical Management System

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Vocia ELD-1. Operation Manual

FDCCM1-MM-L & FDCCM1-MM-R

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

I/O Expansion Box Installation & Operator s Instruction Manual

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Kramer Electronics, Ltd. USER MANUAL

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

USER MANUAL. Kramer Electronics, Ltd. Models:

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

Integrated Stepper Drive & Motor

DVI ELR Extender over one CAT5

Transcription:

Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03

Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The PD26 is a 2-channel dimmer pack for the PROTOCOL lighting control system. The PD26 dimmer pack contains 2 solid-state dimmers. Power is fed to the PD26 from two 20 Amp. breakers on the same electrical phase. Each breaker feeds one dimmers and each dimmer is rated for a maximum output current of 6 amperes ( 920 Watts at 20 VAC ). The PD26 contains two printed circuit boards, the load driver module (LDM) and an INT0 control modules. The dimmers are triggered by the firing board (INT0). THE INT0 - (See diagram on Page 2) The INT0 is a microprocessor based control board with a nonvolatile memory chip, a communications chip, and a regulated DC power supply. The INT0 also contains, address selectors, LED output monitors and other support circuitry. The microprocessor is driven by powerful distributed intelligence software which handles all control and communications functions. The memory chip on the INT0 holds all of the PD26 s pertinent information and settings which include low and high trim levels for both of the outputs it controls. The PD26 does not rely on any shared data source and functions independently of any other system component and without a central system controller. The PD26 communicates with Protocol system stations and controllers over a single twisted-pair of wires and can be connected anywhere on the system network bus. This adds convenience and versatility by allowing PD26 dimmers to be installed close to their loads and/or service panels. THE LDM (LOAD DRIVER MODULE) - (See Diagram on Page 2) The LDM is equivalent to two solid-state relays (SSR's) assembled on a single circuit board. The LDM is mounted at the bottom of the PD26's enclosure which also serves as a heat sink. The relays are triggered by low-voltage signals generated by the INT0 module. These signals are optically-isolated by the LDM circuitry from all line voltage elements. A step-down 9 VAC- transformer on the LDM board supplies power to the INT0 module described above. OTHER INFORMATION- (See diagram Page ) Several PD DIMMERS (PD80, PD26 and PD26 dimmer packs) may be daisy-chained together in any combination, up to a maximum of 63 individually addressed INT0 s (each PD26 and PD08 has x INT0 each, each PD80 has two INT0 s). PD Dimmers are dasiy-chained using the RJPD-6 cables (cat5 network cables) supplied with the units. Each PD26 has a set of address selectors which must be set to a unique address. Please see Table on Page 9 of this manual or the PROTOCOL SOFTWARE MANUAL for more information on addressing the PD26 dimmer pack. DIMMING/SWITCHING - (See Page 8 for more information) Through the PROTOCOL s SOFTPRO configuration software, both of the PD26 s outputs may be independently configured not to dim. A PD26 may control any combination of dimmed and switched loads. There is also a HARDWARE lock to ensure circuits do not dim. Both outputs controlled by the INT0 may be configured not to dim by the installation of a small jumper on the back of the INT0 circuit board. This may be done at the factory or in the field. This jumper may be removed to allow the future dimming of those outputs. Please see Page 8 for location of this jumper. Alternatively, the PD26 may be ordered as a SWITCH-ONLY unit, the PD26-S. This unit has all the same features as the PD26 except that there is no dimming, and there are no chokes installed inside the unit. All other information in this manual is the same for both the PD26 and the PD26-S. 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26-UM

C C PD26 Digital Lighting Systems User's Manual - Page 2 PD26 Load Driver Module Information Figure - PD26 LDM Detail INT0 Control Board LDM SSR's OPTICAL ISOLATORS Ground Load Driver Module 9 VAC RJ5 Female Connectors SSR SSR NEUTRAL BUS Earth Ground H N N2 N3 N N5 N6 H2 Table - Terminals Definition NAME DESCRIPTION Output Of Solid-State Relay # Output Of Solid-State Relay # H Hot Line Feed For Relay. H2 Hot Line Feed For Relay. N-N6 Neutral Bus Connections. Table 2 - Absolute Maximum Electrical Ratings Electrical Characteristic Terminal Maximum Relay Load Current & 6 Amps. Input Current For Relay H 20 Amps. Input Current For Relay H2 20 Amps. Input Voltage H-H2 20 VAC, -Phase. PD26- INT0 Detail Table 3 - INT0 Circuit Legend Microprocessor. 2 Nonvolatile Memory. 3 Communications Chip. Quartz Crystal. 5 Power Supply Capacitor. 6 Voltage Regulator. 7 Signal & Power Connector. 8 Output LED Monitors. 9 Jumper for switches only S-S2 Address Selectors. NOTE: PD26 has one INT0 control board. 5 Components Side INT0 6 S2 2 3 E D F AB 0235 9 8 7 6 8 E D AB F 0235 9 8 7 6 7 S 9 9 Solder Side INT0 Figure 2 - PD26 / INT0 PROTOCOL Firing board Detail 3 S S3 7 8 2 S2 6 5 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26-UM

Digital Lighting Systems User's Manual - Page 3 Enclosure Installation Surface mount the dimmer pack in a well ventilated area where the ambient temperature does not exceed 0 F for full load operation. Allow 2" of side clearance for proper air circulation and servicing. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawings below (FIGURE 3) for the correct dimensions. Conduit shall be pulled to the top of the dimmer packs. NOTE PD26 The PD26 may create a slight buzzing noise and should not be located where this is objectionable. 8.30" (2 mm) Bottom View /2 and 3/ Conduit Knockouts.2" (05 mm) Low Voltage Ports.580" (0 mm).380" (35 mm) Top View.9" (8 mm) Data & Power J Data Only 2.560" (65 mm) 2.5" (55 mm) 2" (5 mm) 2" (5 mm) 2.5" (55 mm) 5" (27 mm) LDM - Load Driver Module H 2 N N2 N3 N N5 N6 3 H2.07" (28 mm) T T.75" (298 mm) ADDRESS SELECTORS INT0 S2 S C 0 VAC W 8 LED's OPTO-ISOLATORS W2 J J2 0 0 Data Bus Connectors PD26 ( LDM) Load Driver Module C 0.75" (9 mm) LED OUTPUT MONITORS 5" (27 mm) PD26 Front Cover Figure 3 - PD26 Dimensional Diagram 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26-UM

PD26 Digital Lighting Systems User's Manual - Page PD26 Low Voltage Wiring Methods W-W2 Shunt Jumpers Protocol systems with 3 control nodes or less (PS Series stations, DCO, DCI or RAU) do not require an external power supply transformer. Power for these components can be supplied by one of the PD DIMMER packs. Figure shows the PD26's network ports with its pin assignments. Installing W and W2 connects the 9 VAC transformer output to the network bus via. The 9 VAC output is permanently connected to J. Figure5 shows a typical small system with one PD Dimmer supplying power to the network. Figure 6 shows a typical system with an external transformer. System accessories such as extension cables and jumper boards are available from DLS and can simplify network bus connections. TO AVOID PARALLELING THE OUTPUTS OF SEVERAL TRANSFORMERS IN A PROTOCOL SYSTEM: ( Do not install the jumpers in any of the PD Dimmers when a DB panel with an external transformer is used in a system. ( Do not install jumpers in more than one PD Dimmer per system when no external transformer is used. W W2 Located On (LDM) Load Driver Module Low Voltage Ports PD Dimmer 0 VAC OUT +D -D PD Dimmer 0 VAC OUT +D -D CAUTION ONLY ONE SET OF W-W2 JUMPERS PER SYSTEM. CONNECT ONLY TO J PINS 8 & 9. CONNECT ONLY TO PINS -. Bottom View Data & Power J Data Only W 8 7 6 5 3 2 W2 0 9 8 7 6 5 3 2 This Port To Be Used For Data Connections ONLY J Figure PD Dimmer Network Ports Internal Connections. Figure 5 - Typical System Powered By a PD Dimmer Module Install W & W2 Jumpers in the first PD Dimmer ONLY. Use w/adaptor for system 8 pin header. #2 AWG Typical 2 HOT & 2 NEUT. To Loads #2 AWG Typical 2 HOT & 2 NEUT. To Loads #2 AWG Typical 2 HOT & 2 NEUT. To Loads PSXX-PT Pigtails PD26 # W-W2 J PD80 J PD08 J POWER & DATA 2 Twisted-Pair (-Wire) May be Carol Cable #C3362 or Equivalent POWER & DATA DATA DATA DATA Figure 6 Typical System Powered By An External DO NOT INSTALL W & W2 Jumpers in any PD Dimmer. #2 AWG Typical 2 HOT & 2 NEUT. Use. #2 AWG Typical 2 HOT & 2 NEUT. #2 AWG Typical 2 HOT & 2 NEUT. PSXX-PT Pigtails POWER & DATA 2 Twisted-Pair (-Wire) May be Carol Cable #C3362 or Equivalent External Power (For Stations & Control Modules) DB Power & Data Distribution Panel RJ5 JACK RJ5-DB DATA PD26 # To Loads J PD80 To Loads J5 PD08 To Loads DATA DATA DATA Network Bus Branch For RAU, DCI-6, DCO- Or Other System Components J 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26-UM

Digital Lighting Systems User's Manual - Page 5 PD26 General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 920 W (6 Amps. ) per dimmer output @ 20VAC. 0 All wiring between the control stations, dimmers, and other system controllers (network bus) is low voltage (NEMA Class 2) and may be run with two, twisted pair, shielded #8 AWG wire. Control network bus may be Carol Cable #C3362 unless otherwise required. Consult the PROTOCOL Hardware Installation Manual, Appendix E, for maximum wire length. 0 PD26 dimmer packs may be fed by one or two 20 A (maximum) branch circuits and may have up to two separately dimmed loads. 0 Both breakers must be on the same power phase. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE PD26 TO ENSURE PROPER WIRING. Figure 7 - PD26 Typical 20 VAC Wiring. CAUTION PD26-20 VAC Models ONLY INT0 Control Board LDM SSR's OPTICAL ISOLATORS Load Driver Module SSR 9 VAC SSR NEUTRAL BUS H N N2 N3 N N5 N6 H2 LOAD # Neutral Bus LOAD #2 Earth Ground Electrical Distribution Panel ON 2x20 A - 20 VAC Breakers On Same Phase 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26 ON For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load: 6 Amperes (920W at 20 VAC). PD26-UM

Digital Lighting Systems User's Manual - Page 6 Figure 8 - PD26 Typical 220/20 VAC Wiring. CAUTION PD26-220/20 VAC Models ONLY PD26-220 General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 380 W (6 Amps. ) per dimmer output @ 20VAC. 0 All wiring between the control stations, dimmers, and other system controllers (network bus) is low voltage (NEMA Class 2) and may be run with two, twisted pair, shielded #8 AWG wire. Control network bus may be Carol Cable #C3362 unless otherwise required. Consult the PROTOCOL Hardware Installation Manual, Appendix E, for maximum wire length. 0 PD26 dimmer packs may be fed by one or two 20 A (maximum) branch circuits and may have up to two separately dimmed loads. 0 Both breakers must be on the same power phase. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE PD26, TO ENSURE PROPER WIRING. INT0 Control Board LDM SSR's OPTICAL ISOLATORS Load Driver Module SSR 9 VAC SSR NEUTRAL BUS H N N2 N3 N N5 N6 H2 LOAD # Neutral Bus LOAD #2 Earth Ground Electrical Distribution Panel ON 2x20 Amp 220 to 20 VAC Breakers On Same Phase 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26 ON For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load: 6 Amperes (380W at 20 VAC). PD26-UM

Digital Lighting Systems User's Manual - Page 7 Figure 9 - PD26-2/2 Low Voltage Load and Power Wiring CAUTION PD26-2/PD26-2 Models ONLY PD26 Electrical Distribution Panel NEUTRAL X PRIMARY ON 2v or 2v SECONDARY X LDM Load Driver Module SSR H LOAD # INT0 Control Board SSR's OPTICAL ISOLATORS Voltage Divider Network NEUTRAL BUS N N2 N3 N N5 N6 SSR H2 LOAD #2 For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load per circuit : 6 Amperes (38W at 2 VAC). NOTES With PD26-2 you may use a single 2 VAC-800 VA or better transformer or two separate 2 VAC-00 VA or better transformers. 2 With PD26-2 you may use a single 2 VAC-00 VA or better transformer or two separate 2 VAC-200 VA or better transformers. 3 Follow transformer's installation & wiring instructions from manufacturer. Maximum Load Per Output: 92 Watts at 2 VAC. 5 Maximum Load Per Output: 38 watts at 2 VAC. 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26-UM

Digital Lighting Systems User's Manual - Page 8 PROTOCOL Address Setting Up to 63 uniquely addressed INT0 boards (two in each PD80, one in each PD26 and PD26) may be installed in any one system. Each INT0 must be set to a unique decimal address between and 63. INT0 #63 output is not available for use. Total number of zones ((63 x ) - = 25). Refer to TABLE On Page 9 of this manual for proper setting of the address selectors S and S2 on the PD26. Example: S2 & S should be set respectively to & A if the desired address is 26 ( x 6 + A = 26, A =0). In this example, the two outputs of PD26 # 26 are referred to as 26. and 26. when configuring buttons on PROTOCOL stations, using the PROTOCOL SOFTPRO programming software. Address used must not be an address already used elsewhere in the system). NOTE: It is also possible to quadruple the maximum number of outputs on a system up to 00 circuits. An INT0 may have a decimal address of up to, and including, 252. Please contact factory for more details. For a complete Decimal to Hexadecimal conversion chart, please refer to Appendix A in the PROTOCOL Hardware and Software Manuals. Non-Dim Output Setting PD26 Installation Check List BEFORE ENERGIZING THE PD26 MAKE SURE: 0 Loads are tested before connecting to dimmers. 0 Breaker feed lines are on same electrical phase. 0 PD26 has been properly grounded. 0 All line voltage screw terminals are properly tightened to prevent hot spots. 0 Low voltage data lines connections are properly insulated. 0 Low voltage data lines polarity is observed throughout the system. 0 The PD26 s INT0 is set to the right addresses. Whilst both outputs may be programmed to dim or not dim through the SOFTPRO configuration software, in some circumstances it may be preferable for both outputs in the PD26 to be configured for non-dim (switch only) operation by a hardware lock. This prevents inadvertent dimming, or damage, of loads that cannot be dimmed, such as contactors, mechanical relays, motors, non-dim fluorescent, etc... Since this procedure involves adding a jumper to the INT0 board, it is preferable to have it performed by the factory, at time of order. However, any qualified electronic technician can perform the procedure in the field when necessary. Figure 0 shows the location for installing the non-dim (ND) jumper. Figure 0 - PD26 INT0 DETAIL 0 ALL KNOCKOUT HOLES MUST BE COVERED WHEN UNIT IS INSTALLED 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26 Jumper to Ensure Non-Dim function of INT0 to be installed here. 0 5 5 0 INT0 2 3 5 S S2 8 6 7 INT0 Solder (Back) Side PD26-UM

PD26 Digital Lighting Systems User's Manual - Page 9 Table - PD DIMMER Address Selection Information 00 INVALID ADDRESS 0 set S2,S to 0, 02 set S2,S to 0,2 03 set S2,S to 0,3 0 set S2,S to 0, 05 set S2,S to 0,5 06 set S2,S to 0,6 07 set S2,S to 0,7 08 set S2,S to 0,8 09 set S2,S to 0,9 0 set S2,S to 0,A set S2,S to 0,B 2 set S2,S to 0,C 3 set S2,S to 0,D set S2,S to 0,E 5 set S2,S to 0,F 6 set S2,S to,0 7 set S2,S to, 8 set S2,S to,2 9 set S2,S to,3 20 set S2,S to, 2 set S2,S to,5 22 set S2,S to,6 23 set S2,S to,7 2 set S2,S to,8 25 set S2,S to,9 26 set S2,S to,a 27 set S2,S to,b 28 set S2,S to,c 29 set S2,S to,d 30 set S2,S to,e 3 set S2,S to,f 32 set S2,S to 2,0 33 set S2,S to 2, 3 set S2,S to 2,2 35 set S2,S to 2,3 36 set S2,S to 2, 37 set S2,S to 2,5 38 set S2,S to 2,6 39 set S2,S to 2,7 0 set S2,S to 2,8 set S2,S to 2,9 2 set S2,S to 2,A 3 set S2,S to 2,B set S2,S to 2,C 5 set S2,S to 2,D 6 set S2 S to 2,E 7 set S2,S to 2,F 8 set S2,S to 3,0 9 set S2,S to 3, 50 set S2,S to 3,2 5 set S2,S to 3,3 52 set S2,S to 3, 53 set S2,S to 3,5 5 set S2,S to 3,6 55 set S2,S to 3,7 56 set S2,S to 3,8 57 set S2,S to 3,9 58 set S2,S to 3,A 59 set S2,S to 3,B 60 set S2,S to 3,C 6 set S2,S to 3,D 62 set S2,S to 3,E 63 set S2,S to 3,F NOTES: 00 Decimal (S2,SI = 0,0) is not allowed on any device. Max PD26 Address: 63 Decimal (S2,S = 3,F) 7588 NW 8th Street, Miami, Fl. 3326 Tel: 305-26-839 or -877-26-839 Fax: 305-26-6637 PD26-UM

LIMITED WARRANTY Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty. Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state. Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective. No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory. Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission. Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems. Defective merchandise may be returned to Digital Lighting Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting Systems distributor, representative, or: Digital Lighting Systems, Inc. Attn: Customer Service Department 7588 NW 8th Street Miami, FL 3326 (305) 26-839

Digital Lighting Systems, Inc. 7588 NW 8th Street Miami, FL 3326 www.digitallighting.com Tel 305-26-839 Fax 305-26-6637 e-m info@digitallighting.com Printed in U.S.A. February 2003