General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

Similar documents
General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Product type designation

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

General information. Configuration control. Display. Control elements. Supply voltage

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage. Input current. Power losses

General information. Supply voltage

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. Supply voltage

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Product type designation. General information. Supply voltage. Input current

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Data sheet CPU 015PN (015-CEFPR01)

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Preface. Documentation guide. Product overview.

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

Data sheet CPU 015PN (015-CEFPR00)

General information. Display. Supply voltage

SIPLUS CPU 313C-2DP. Function

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Product type designation. General information. Supply voltage

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

CPU 412H. Function. Parameterizable properties

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

CPU 412. Function. Programmable properties

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Data sheet SLIO CPU 015PN (015-CEFPR01)

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Data sheet CPU 315SN/PN ECO (315-4PN33)

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet CPU 013C (013-CCF0R00)

Data sheet VIPA CPU M13C (M13-CCF0000)

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Data sheet CPU 315SN/NET (315-4NE12)

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet CPU 315SB/DPM (315-2AG12)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

Data sheet CPU 315SB/DPM (315-2AG12)

General information. Supply voltage

SIMATIC S Central processing units

CPU PN (6ES7511-1AK00-0AB0) SIMATIC S CPU PN (6ES7511-1AK00-0AB0) Preface. Documentation guide. Product overview.

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet VIPA CPU 115DP (115-6BL22)

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

CPU PN/DP (6ES7517-3AP00-0AB0) SIMATIC S CPU PN/DP (6ES7517-3AP00-0AB0) Preface. Documentation guide. Product overview.

CP ADVANCED. Function

Data sheet CPU 115 (115-6BL02)

SIMATIC PC-based controller

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Multi Panel options. SIMATIC WinAC MP 2/169

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

CPU 1214C. Overview. Design. The compact CPU 1214C has:

System description SLIO

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

Supply voltage. Input current. Encoder supply. Memory

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

Main Catalog 2012/2013 for specialists in automation and control technology

PA ROUTERS. The following criteria can be applied when choosing the network transition:

CP BACNET Function

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Transcription:

Datasheet SIMATIC DP, CPU 1510SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 100 KB FOR PROGRAM AND 750 KB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 72 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY General information Hardware product version Configuration control via dataset FS01 Control elements Mode selector switch 1 Supply voltage Type of supply voltage permissible range, lower limit (DC) permissible range, upper limit (DC) Reverse polarity protection 24 V DC 19.2 V 28.8 V Mains buffering Mains/voltage failure buffering time Input current Current consumption (rated value) Inrush current, max. I²t Power Infeed power to the backplane bus Power loss Power loss, typ. 5 ms 0.6 A 4.7 A; Rated value 0.14 A² s 8.75 W 5.6 W Memory Number of slots for SIMATIC memory card 1 SIMATIC Memory Card required Work memory integrated (for program) integrated (for data) 100 kbyte 750 kbyte Page 1/10 28.08.2014 Copyright Siemens AG

Load memory plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup maintenance-free CPU processing times for bit operations, typ. for word operations, typ. for fixed point arithmetic, typ. for floating point arithmetic, typ. 72 ns 86 ns 115 ns 461 ns CPU-blocks Number of blocks (total) 2 000 DB Number, max. 2 000; Number range: 1 to 65535 Size, max. 750 kbyte FB Number, max. 1 998; Number range: 1 to 65535 Size, max. 100 kbyte FC Number, max. 1 999; Number range: 1 to 65535 Size, max. 100 kbyte OB Size, max. 100 kbyte Number of free cycle OBs 100 Number of time alarm OBs 20 Number of delay alarm OBs 20 Number of time interrupt OBs 20 Number of process alarm OBs 50 Number of DPV1 alarm OBs 3 Number of isochronous mode OBs 1 Number of technology synchronous alarm OBs 2 Number of startup OBs 100 Number of asynchronous error OBs 4 Number of synchronous error OBs 2 Number of diagnostic alarm OBs 1 Nesting depth per priority class 24 Page 2/10 28.08.2014 Copyright Siemens AG

Counters, timers and their retentivity S7 counter Number 2 048 Retentivity adjustable IEC counter Number Retentivity Any (only limited by the main memory) adjustable S7 times Number 2 048 Retentivity adjustable IEC timer Number Retentivity Any (only limited by the main memory) adjustable Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. 128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB Flag Number, max. 16 kbyte Number of clock memories 8 Data blocks Retentivity adjustable Retentivity preset No Local data per priority class, max. 64 kbyte; max. 16 KB per block Address area Number of IO modules 1 024 I/O address area Inputs Outputs per integrated IO subsystem 32 kbyte; All inputs are in the process image 32 kbyte; All outputs are in the process image Inputs (volume) 8 kbyte Outputs (volume) 8 kbyte per CM/CP Inputs (volume) 8 kbyte Page 3/10 28.08.2014 Copyright Siemens AG

Outputs (volume) 8 kbyte Subprocess images Number of subprocess images, max. 32 Address space per module Number of IO subsystems 2 Hardware configuration Number of DP masters via CM 1 Number of IO Controllers integrated 1 via CM 0 Rack Modules per rack, max. 64 Rack, number of rows, max. 1 PtP CM Number of PtP CMs Time of day Clock Type Deviation per day, max. Backup time the number of connectable PtP CMs is only limited by the number of available slots Hardware clock 10 s; Typ.: 2 s 6 wk; At 40 C ambient temperature, typically Operating hours counter Number 8 Clock synchronization supported to DP, master to DP, slave in AS, master in AS, slave on Ethernet via NTP Interfaces Number of PROFINET interfaces 1 Number of PROFIBUS interfaces 1 1. Interface Interface types Number of ports 3 Page 4/10 28.08.2014 Copyright Siemens AG

integrated switch RJ 45 (Ethernet) Protocols PROFINET IO Controller PROFINET IO Device SIMATIC communication Open IE communication Web server Media redundancy 2. Interface Interface types Number of ports 1 RS 485 Protocols SIMATIC communication PROFIBUS DP master PROFIBUS DP slave No Interface types RJ 45 (Ethernet) 100 Mbps Autonegotiation Autocrossing Industrial Ethernet status LED RS 485 Transmission rate, max. 12 Mbit/s Protocols Number of connections Number of connections, max. 64 Number of connections reserved for ES/HMI/web Number of connections via integrated interfaces 10 64 Number of S7 routing paths 16 PROFINET IO Controller Services PG/OP communication S7 routing Isochronous mode Page 5/10 28.08.2014 Copyright Siemens AG

Open IE communication IRT MRP ; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50 PROFIenergy Prioritized startup Number of connectable IO Devices, max. 64 Number of connectable IO Devices for RT, max. 64 of which in line, max. 64 Number of IO Devices with IRT and the option "high performance", max. Number of IO Devices that can be simultaneously activated/deactivated, max. 64 8 Number of IO Devices per tool, max. 8 Updating times with RT The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data for send cycle of 250 µs 250 µs to 128 ms for send cycle of 500 µs 500 µs to 256 ms for send cycle of 1 ms 1 ms to 512 ms for send cycle of 2 ms 2 ms to 512 ms for send cycle of 4 ms 4 ms to 512 ms for IRT with the "high performance" option for send cycle of 250 µs 250 µs to 4 ms for send cycle of 500 µs 500 µs to 8 ms for send cycle of 1 ms 1 ms to 16 ms for send cycle of 2 ms 2 ms to 32 ms for send cycle of 4 ms 4 ms to 64 ms for IRT with the "high performance" option and parameter assignment for so-called "oddnumbered" send cycles Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs... 3.875 µs) PROFINET IO Device Services PG/OP communication S7 routing Isochronous mode No Open IE communication IRT, supported Page 6/10 28.08.2014 Copyright Siemens AG

MRP, supported PROFIenergy Shared device Number of IO Controllers with shared device, max. 4 SIMATIC communication S7 communication, as server S7 communication, as client User data per job, max. See online help (S7 communication, user data size) Open IE communication TCP/IP Data length, max. 64 kbyte several passive connections per port, supported ISO-on-TCP (RFC1006) Data length, max. 64 kbyte UDP Data length, max. 1 472 byte DHCP SNMP DCP LLDP No Web server HTTP HTTPS ; Standard and user-defined pages ; Standard and user-defined pages PROFIBUS Services PG/OP communication S7 routing Isochronous mode No Equidistance No Number of DP slaves 125 Activation/deactivation of DP slaves PROFIBUS DP master Number of connections, max. 48 Further protocols MODBUS ; MODBUS TCP Media redundancy Page 7/10 28.08.2014 Copyright Siemens AG

Switchover time on line break, typ. 200 ms Number of stations in the ring, max. 50 Isochronous mode Isochronous mode (application synchronized up to terminal) S7 message functions Number of login stations for message functions, max. 32 Block related messages Number of configurable alarms, max. 5 000 Number of simultaneously active alarms in alarm pool Number of reserved user alarms 290 Number of reserved alarms for system diagnostics Number of reserved alarms for motion technology objects Test commissioning functions Status block Single step 100 160 No Status/control Status/control variable Variables of which status variables, max. of which control variables, max. Inputs, outputs, memory bits, DB, times, counters 200; per job 200; per job Forcing Forcing Forcing, variables Inputs, outputs Number of variables, max. 200 Diagnostic buffer present Number of entries, max. 1 000 of which powerfail-proof 500 Traces Number of configurable Traces 4 Interrupts/diagnostics/status information Diagnostics indication LED RUN/STOP LED Page 8/10 28.08.2014 Copyright Siemens AG

ERROR LED MAINT LED Monitoring the supply voltage (PWR-LED) Connection display LINK TX/RX Supported technology objects Motion Speed-controlled axis Number of speed-controlled axes, max. 6 Positioning axis Number of positioning axes, max. 6 external encoders Number of external encoders, max. 6 Controller PID_Compact PID_3Step ; Universal PID controller with integrated optimization ; PID controller with integrated optimization for valves Counting and measuring High-speed counter Ambient conditions Operating temperature horizontal installation, min. 0 C horizontal installation, max. 60 C vertical installation, min. 0 C vertical installation, max. 50 C Storage/transport temperature min. -40 C max. 70 C Configuration Programming Programming language LAD FBD STL SCL GRAPH Know-how protection User program protection Copy protection Page 9/10 28.08.2014 Copyright Siemens AG

Block protection Access protection Protection level: Write protection Protection level: Read/write protection Protection level: Complete protection Cycle time monitoring lower limit upper limit Dimensions Width Height Depth Weights Weight, approx. adjustable minimum cycle time adjustable maximum cycle time 100 mm 117 mm 75 mm 310 g last modified: 21.08.2014 Page 10/10 28.08.2014 Copyright Siemens AG