USTER TESTER 5-C800. The filament yarn inspection system. Technical Data

Similar documents
u TESTER 6-C800 The quality testing system Technical Data

USTER ZWEIGLE TWIST TESTER 5-SA

USTER QUANTUM EXPERT 3 ULTIMATE

u SENTINEL The ring spinning optimization system Technical Data

USTER QUANTUM EXPERT 3

COVATEST Capacitive Evenness Tester for Slivers, Rovings, and Spun Yarns with optional Hairiness Module

u AFIS PRO 2 The fiber process control system Technical Data

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

FX 3300 Air Permeability Tester III Scope

Air data test indicator Model CPA2501

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

u HVI 1000 The fiber classification and analysis system Technical Data

Hand-Held Thermometer Model CTH 6200

Portable low-pressure controller Model CPC2000

Cloud Human Machine Interface SERIES

QC20-W wireless ballbar system description and specifications

Hand-held thermometer Model CTH6200

Panel PC. 15" wide-screen display IndraControl VPP 15

Immersion Temperature Sensors

Small Tensile Testers for universal usage Z3, Z5 Z10 Z20, Z50. page 1

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

Luminaire testing device

We Build Confidence...

Hand-held thermometer Model CTH6200

Air Permeability Tester FX 3300 LABOTESTER III

PTB 420 Auto. Fully Automated 4 in 1 Tablet Testing Instrument

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

PTB 311E / 511E / 311E-800

INSITE Features Notes

PTB111E_111E-500_111E-800

User Manual. cmt-iv5 Startup Guide

hm 2010 / 2020 DC Microprocessor-controlled rotary sealer for medical packaging (validatable process in accordance with ISO 11607)

Humidity transmitter for critical climate applications

ND 1202 T. Axes 2 (XZ) Encoder inputs* » 1 V PP or «TTL (other interfaces upon request) Subdivision factor* 10-fold (only for 1 V PP ) Display step 1)

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

ModEva numerical control units can control up to 18 axes of which 2 are synchronized hydraulic axes especially intended for press-brakes.

Precision pressure indicator 1- or 2-channel version Model CPG2500

HMIPWC7D0E01 Panel PC Optimum - Compact Flash - 15'' - DC - Fanless

modunet292: novanet-ethernet interface

ProcessCalibrator Model CPH6000

Microplate Absorbance Reader Labtech LT-4500

Electronic Temperature Controller. Instruction Manual Version

Refrigeration and Air Conditioning Controls. Technical Leaflet. Monitoring, Control and Alarm System m2 REFRIGERATION AND AIR CONDITIONING

OPTIFLEX 1100 C Technical Datasheet

LMI 4000 Series Melt Flow Indexers

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION

LSM-6200 Display Unit SERIES 544 Standard Display Unit for Laser Scan Micrometer

INTECONT PLUS for Measuring Systems

AUTOMATIC TENSION & COMPRESSION TESTING MACHINE

E350 series 2. ZCF100Ax/Cx s2. Technical Data. Electricity Meters IEC/MID Residential

Portable pressure calibrator Model CPH7600

Pressure Aging Vessel PAV3

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

For synchronized press brakes. 4 or 7 axes, 2 of them synchronized axes for the beam. DNC 884S PS or DNC 887S PS

INSITE Features Notes

Vibration Tester. Test and Measurement Instruments C.C.

RESIDENTIAL ZMF100AC, ZMF100AB, ZFF100 TECHNICAL DATA. IEC-specific data Current Base current I b. Measurement Accuracy. Measurement Behaviour

Beautifully Simple Photofinishing Solutions.

Dual-core Intel Atom processor. 2 x 3.5" SATA(II)/2.5" SATA/SSD. 1. The standard system is shipped without HDD.

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

INSITE Features Notes

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

Dual-core Intel Atom processor. 6 x 3.5" SATA(II)/2.5" SATA/SSD. 1. The standard system is shipped without HDD.

Super universal modules

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Battery Analyzer MST Instructions

LMI 4000 Series Melt Flow Indexers

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Chatillon TCD225 Series Digital Force Testers

HCC-F Software. Honigmann Computer Control - Precision Friction Meter

Vectis AX4 / AX8 / AX16

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Dual-core Intel Atom processor. 4 x 3.5" SATA(II)/2.5" SATA/SSD. 1.The standard system is shipped without HDD.

Relative humidity Noise level 4-7" reels: 8-72 mm tapes 11-15" reels: 8-72 mm tapes Max. 3.5 kg

Precision digital measuring device PHYSICS 51

Pneumatic Precision Pressure Controller Model CPC6000

Thermal Shake Touch heat. cool. mix. repeat.

PHYSICS Digital Measuring Devices

BLITZ 60L - BLITZ 55 - BLITZ 50. Double head sawing machine with motorized movement of the mobile head and electronic control of the head tilting

tiamo TM Titration and more Networked Titration Data System

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

Compact PC IndraControl VPB

Box-PC / Displays. Compact PC IndraControl VPB

Mobile Data Collector

i-sensys MF4320d Up to 1200 x 600 dpi with Automatic Image Refinement % in 1% increments 250-sheet tray 1-sheet manual feed slot

PMI Borescope Lizard 100 Series User Guide

Datasheet.

Room unit with PPS2 interface

Precimar. PLM and CiM Universal Length Measuring Machines

831 KF Coulometer. Never before has coulometric Karl Fischer water determination been so economical!

Operating Instruction

Room unit with PPS2 interface

FG-3000 Digital Force Gauge Operation Manual

Thermal Mass Flowmeter

Transcription:

USTER TESTER 5-C800 The filament yarn inspection system Technical Data February 2014

Testing and analyzing installation for the quality assurance of filament yarns Elements of the USTER TESTER 5-C800 installation 4 1a 1 * USTER TESTER 5-C800 2 (11)

Basic Installation 1 Test Unit Sensor CC, Evenness unit Sensor Humidity/temperature (integrated) 1a Changer/Yarn Feeder (only for UT5-C800/A) 2 Operating Unit * Single-package creel (only for UT5-C800/SA) Options 3 Sensor FSA, Count Manual KB-System SPG (no illustr.) Special accessories 4 Tensioner carrier with 24 tensioners 3 2 USTER TESTER 5-C800 3 (11)

Basic Installation Overall Installation Functions: Measurement of mass variations in filament yarns Collection, evaluation and storage of measurement values Automatic check of all measured values, diagrams and spectrograms Editor for customizing report layouts Filter functions for quick data retrieval and for the preparation of long-term reports Simulation of yarn boards, woven and knitted fabrics Versions: USTER TESTER 5-C800/A (automatic version) USTER TESTER 5-C800/SA (semiautomatic version) Included in the delivery: Test unit Operating unit (Control unit, screen, keyboard and mouse, backup unit) Single-package carrier (for semiautomatic version only) Application software Table set TEST UNIT (1) Subsystems of the USTER TESTER 5-C800 basic version: Sensor CC: Capacitive measuring unit for the determination of mass variations in filament yarns Measurement range: approx. 10 dtex to 2500 dtex (3.0 to 10 dtex upon request; depending on the structure of the yarn, yarn count of up to approx. 6000 dtex can be measured) Integrated sensor for measurement of humidity and temperature in the en- vironment of the Test unit Humidity: +/- 3% rh at a temperature of 21 C Temperature: +/- 0.3 C at a temperature of 20 C Sensor humidity and temperature: Tensioner C: Material tensioner system for filament yarn Conveyor C: Material conveying system for filament yarn Testing speed: 25 to 800 m/min Twister C: Material twisting system for filament yarn Base C: Absorber for the removal of the tested yarn Keypad: Control keys for easy operation Display of active sensors and actual speed USTER TESTER 5-C800 4 (11)

Changer/ Yarn Feeder (1a) For the automatic version only Function: Automatic transfer of the yarn from the package changer and insertion into the measuring slot (max. 24 positions). Operating Unit (2) Computer software: The USTER TESTER 5-C800 is a menu driven design that allows quick access and selection of testing, setup, calibration and data management. These features include: Windows XP operating system with icon-based software Simple user interface Error messages for troubleshooting Network capabilities Computer hardware: Industrial computer system with dual core 2.5 GHz processor and 4GB RAM DVD-R drive 2 hard drive, 250 GB or better Computer accessories: 19 High r esolution flat panel LCD monitor with Integrated sound bar Laser printer Keyboard Optical mouse USTER TESTER 5-C800 5 (11)

Options Sensor FSA, Application range: Manual determination of the absolute count of filament yarns in the count range count manual (3) of 10 dtex to 6000 dtex. Connection to Function: Connection set to connect the USTER TESTER 5 to the USTER LAB EXPERT LAB EXPERT KBS, Knowledge Function: Knowledge-based software module for detecting the cause of periodic faults Based System in the spectrogram: The parts of the respective production machine which may be defective are marked in the graphic represatation The gearing layouts of the most important production machines are stored Software-supported configuration of the gearing layouts and the knowledge base Special Accessories Tensioner carrier Application: For the measurement of yarn packages from a bobbin carrier without yarn wtih 24 tensioners (4) tensioners Packages carrier Application: Packages carrier for creeling and transporting up to 24 bobbins with Ø max. 125 mm USTER TESTER 5-C800 6 (11)

Application Software Reports Type of reports: Test reports of measurement series USTER Quality Report (summary of the key data and the test results on one page; quality certificate) QUALIPROFILE (graphic presentation of the overall yarn quality, with respect to the USTER STATISTICS or to a customer-specific yarn profile) Long-term reports Pre-configured standard reports for different applications Customized reports Display and print-out of the reports: Automatic reports Exception reports As required Limit values: Determination of fixed limits or definition of limits based on the USTER STATISTICS stored in the system Verification of measured values Measured values which exceed the set limit values will be marked Numerical output of Unevenness U: Determination of the mass unevenness by help of the irregularity results (SENSOR CC) Coefficient of variation CV: Determination of the mass unevenness by help of the coefficient of variation Coefficient of variation CV(L): Determination of the unevenness for cut lengths of 1, 3, 5, 10, 50 or 100 m and for the inert and half-intert modes. Maximum mass variation: m (max) = maximum mass increase m (min) = maximum mass reduction Possible cut lengths for the calculation: 1, 3, 5, 10, 50 or 100 m Relative count: Percentage count variation of the test material between single tests in a sample, with reference to a selectable material length Numerical output of Absolute count: Determination of the length-related mass value results (count measuring system) USTER TESTER 5-C800 7 (11)

STATISTICS Statistical values: Overall result protocol with statistical data of the result columns Mean value Median Standard deviation s Coefficient of variation CV 95% confidence range Min. value Max. value Graphic output of Diagram: Sensitivity selectable in the ranges of ±5% to +500/ 100% results (SENSOR CC) Longitudinal scale in the ranges of 1 to 10000 m per line Cut lengths: normal, 0.1, 0.3, 1, 3, 10, 30, 100, 300, 1000 m, inert and half-inert Possibility of representing 3D diagrams Spectrogram: Wavelength range up to 1/5 of the measured test length, but to a maximum of 2200 m Max. 160 channels (compared to the USTER TESTER 3, the resolution has been doubled) Possibility of representing 3D spectrograms Variance-length curve: Cut lengths from 2 cm to 600 m, whereby the maximum calculated cut length is about 1/15 of the measured test length (compared to the USTER TESTER 3, the resolution has been doubled) Possibility of representing 3D variance-length curves Frequency distribution diagram: Representation of the parameter variations within single tests Data protection Backup: The data are stored on the 2nd hard disk For long-term storage, the data can be archived on the 2nd hard disk (backup unit) and presented again as required at a later date All settings, measurement values and diagrams are stored Input of data, output Dialog and report English, German, French, Italian, Spanish, Portuguese, Turkish, Russian or of results, languages languages: Chinese can be selected via the operating menu (other languages on request) units Possible units: Titer: tex, dtex, den Speed: m/min, yd/min Test time: 6 seconds to 20 minutes, variable USTER TESTER 5-C800 8 (11)

Selftest Function check: Initiated automatically when the installation is switched on Comprehensive function check and special test programs can be initiated at any time via the diagnosis menu General General ambient Room climate: The ambient conditions must be maintained in order to avoid any influencing on conditions the test material according to ISO 139.1973 or DIN 53 802. Humidity: 65±2% relative humidity. Temperature: according to ISO 139.1973 or DIN 53 802 20±2 C for temperate climates 27±2 C for tropical climates Installation data Electrical connections: Single phase mains with protective conductor Mains voltage range: Voltage selector Nominal voltage (-10/+6%) 50/60 Hz 105 V 100 110 V 125 V 115 127 V 145 V 130 150 V * 210 V 200 215 V 230 V 220 230 V 250 V 240 250 V *) Caution: 150 V only +3% tolerance Mains frequency: 48 62 Hz Power consumption: Max. 1000 VA Compressed air Air quality: according to ISO 8573.1, class 3 connection: Min. pressure at inlet of air filter regulator: 6 bar Max. pressure at inlet of air filter regulator: 7 bar Requirement compressed air: Standard C800: 8 m 3 /h Min. internal diameter of the connection: 8 mm Max. length of the connection: 5 m Max. temperature difference between compressed and laboratory air: 10 C Compressed air connection for additional tester will be doubled. For detail please refer to the above mentioned information. USTER TESTER 5-C800 9 (11)

Gross weight of the Semiautomatic version: Approx. 100 kg basic installation Automatic version: Approx. 110 kg Space required for the installation of the USTER TESTER 5-C800 At a vibration-free location Manual or automatic count measurement systems must be set up on a separate table 1429 mm 955 mm 658.5 mm 585 mm USTER TESTER 5-C800 10 (11)

THE YARN INSPECTION SYSTEM 834 mm 257 mm 486.5 mm 968.5 mm 1712 mm Subject to technical modifications Uster Technologies has made all reasonable efforts to ensure that all information is accurate at the time of publication. Hereby it is declared that alterations to the product may be possible at any time. In these cases the information contained in this technical datasheet is subject to change without notice. February 2014 Uster Technologies AG Sonnenbergstrasse 10 CH-8610 Uster / Switzerland Phone +41 43 366 36 36 Fax +41 43 366 36 37 www.uster.com sales@uster.com 02.14 Copyright 2014 Uster Technologies AG