Technical Data Sheet OPUS A6 STANDARD Full TDS OPUS A6sF,

Similar documents
Technical Data Sheet OPUS A6 STANDARD Full

Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF,

Technical Data Sheet OPUS A3 STANDARD Full

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A8 STANDARD Full TDS OPUS A8sF,

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A6 ECO Basic

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A3 ECO Full

MultiViu Flex 4 Data Sheet

Technical Data Sheet OPUS A6 ECO Full

Technical Data Sheet OPUS A3 ECO Basic TDS OPUS A3eB,

Technical Data Sheet OPUS A3 ECO Basic

Technical Data Sheet OPUS A8 ECO Full

Technical Data Sheet OPUS A8 ECO Basic

Technical Data Sheet OPUS A3 ECO Full

Technical Data Sheet OPUS A3 STANDARD Basic

Technical Data Sheet OPUS A6 ECO Basic

Technical Data Sheet OPUS A6 STANDARD Full

I /O. OPUS A6s - For Perfectionists IP 65 IP "

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Operating Manual HMI 4 HMI 4. Operating Manual Hardware Description INTER CONTROL GmbH & Co. KG

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 7 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600 CP635, CP635-B, CP635-WEB

PowerView Model PV485. Installation Manual Section 78

2 Control Equipment for General Applications

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP635-FB, CP635-FW

Absolute Encoders Multiturn

A-307. Mobile Data Terminal. Android OS Platform Datasheet

IRMA MATRIX Release 2

HelmView 450 Model HV450. Installation Manual Section 78

Inclination sensors 1-dimensional, measuring range

HelmView Model HV750. Installation Manual Section 78

Installation instructions Process and dialogue module PDM360 NG CR1080 CR9223 CR1081 CR9224 CR CR1084 CR9226 CR1085 CR9227

HelmView Model HV750; HVS750. Installation Manual Section 78

Inclination sensors 2-dimensional, measuring range up to ±90

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

CCPILOT PRODUCT CATALOG 2018 AN ACTUANT COMPANY

Faults on the system Proximity switch connection technology:

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Valueline Industrial PC

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

TECHNICAL DATASHEET #TDAX050000K CAN

CCD1100S. Technical Data Sheet

MRS Electronic, Inc Winner Circle Dayton, OH (937) Datasheet CAN Relay Box 16. Page 1 of 8 Version 1.

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MRS Electronic GmbH. Datasheet CAN I/O & CAN PLC CAN I/O & CAN PLC. CAN I/O & CAN PLC Site 1 of 5 Version 1.0

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Features. Intel 45nm Atom Processor N270: 1.6 GHz

Fingertip Joystick. Single-axis joystick for easy and ergonomic actuation. Use. Variants

RoHS. High shaft load capacity. Shock / vibration resistant

F1000 User's Manual. (Version: V1.01)

Mobile Automation. Products and Services. We automate your success.

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

Electronic Control Unit RC

NOVOHALL Transducer 5 up to 50 mm touchless. Series TFD-4000

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull

DRTS 33. The new generation of advanced three phase relay test set

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

CDC2000X. Technical Data Sheet

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

DATA SHEET Advanced Graphical Interface, AGI 100 series

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

D E C E M B E R

Modular controllers CECX

XC-CPU-201 XC-CPU-201-XV

Linear Position Transducer HLT 1000-R2

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Inclinometer. 4-20mA and RS232

DRTS 66 can test all the following relays

LMC078CECS20T motion controller LMC078-20DIO transistor sercos compact Ethernet Canopen 24Vdc

Programmable logic valve control type PLVC 8

L-LAS Series. L-LAS-TB-F-6x1-40/40-CL L-LAS-TB-F-1x6-40/40-CL. Design. L-LAS Series Laser Line Sensors. Product name:

General Operating, Maintenance and Installation Manual

Digital Speed Controller User Manual

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Data Sheet for Joysticks

Evo2. Free programmable room controller. Summary

Data sheet CC 03, Commander Compact (603-1CC21)

(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!

Pioneering new technologies. Technical Data. Electronic Control Unit ESX-3CM.

Mobile Automation. Products and Services. We automate your success.

Data Sheet for Linear Sensors

Rotary Measuring Technology Absolute encoders, Multiturn, DeviceNet

VESA 75/75 or 100/100 (full metal housing only); fastening clips (built-in-variant only)

MCX06C Programmable controller

Solid State Battery Fuel Gauge

General information. Display. Supply voltage. Input current

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Transcription:

Technical Data Sheet OPUS A6 STANDARD Full TDS OPUS A6sF, 02.10.2012 OPUS A6 STANDARD Full Landscape OPUS A6 STANDARD Full Portrait OPUS A6 Standard Full Landscape/Portrait

1 Order Numbers OPUS A6 STANDARD Full Wachendorff Projektor Landscape Portrait Landscape/Portrait CoDeSys Landscape Portrait Landscape/Portrait ISO-VT Landscape 2 Mechanical 2.1 Dimensions OPUSA6SL1CANF000 OPUSA6SP1CANF000 OPUSA6SN1CANF000 OPUSA6SL1CDSF000 OPUSA6SP1CDSF000 OPUSA6SN1CDSF000 OPUSA6SL1ISOF000

2.2 Housing Plastic housing, colored light grey (RAL 7035) with black rubber frame 2.3 Mounting landscape or portrait standalone in-dash 3 Display Type Size Mounting accessories (not included): In-Dash mounting frame (OPUSA6ZBEB001) Standalone mounting adaptor for RAM mounting system (OPUSA6ZBAH001) TFT Color Graphic LCD with LED backlight 7, 152 mm (W) x 91 mm (H) Resolution 800 x 480 px (WVGA), 15:9 Colors Brightness 262k typ. 400 cd/m² Contrast Ratio typ. 500:1 4 Input Devices 4.1 Touch analog resistive 4.2 Left Keypad 6 keys with tactile feedback blue LED backlight Lifetime 1.000.000 actuations 4.3 Right Keypad 6+3 keys with tactile feedback blue LED backlight Lifetime 1.000.000 actuations 4.4 Indicators and Sensors Light sensor 1 Multicolor-LED 3 Status-LED s 4.5 Encoder optical encoder with 16 mechanical detents and push function lifetime: 1 million cycles

5 Electronics 5.1 Processor platform CPU Mass storage RAM RTC Freescale I.MX35, 532 MHz 1 GByte (approx. 900 MB for customer use) 128 Mbyte (256 Mbyte available Jan-2013) buffered by gold cap 5.2 Buzzer 65 db(a) in 30 cm distance lifetime min. 1000h 5.3 Interfaces 5.3.1 Power supply Operating voltage range Protection Overvoltage resistance Inverse polarity protection 9 36 V DC short circuit protection 48V for max. 2 minutes up to -48 V DC for max. 5 minutes Current consumption (without external load), max Power Mode current at 13,5 V DC current at 27 V On 900 ma 500 ma Low-power 200 ma 120 ma Sleep 100 ma 65 ma Off 0 ma 0 ma 5.3.2 Can Interfaces 2 x CAN-Interfaces ISO 11898, CAN-specification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) 5.3.3 RS232 1 x RS232-Interface Type Speed EIA232 (only RxD, TxD, GND) max. 115 Kbps 5.3.4 USB Host 2.0 Main connector On front 1 x Full speed 1 x USB slot High speed 5.3.5 Inputs 4 configurable analog/digital inputs input impedance resolution Voltage range > 3kOhm 10 bit resolution (1028 digits, 1 digit = 11,7 mv) 0 12 V max. protectable input voltage 36 V DC protection frequency short circuit protection max. signal frequency 50 Hz 5.3.6 Outputs 3 digital outputs short circuit protection I max R DS,on R DS,off up to 36 V 300 ma open drain < 1 Ohm > 100 kohm 5.3.7 Video-Interface 3 analog video inputs, 1 Vss camera control output (open drain) for special functionality (mirror, shutter, heating etc.), ampacity 300mA @ 12V DC

5.3.8 Ethernet-Interface 1 x 10/100 Mbit/s Base T 6 Connections Main connector Tyco-AMP 1437288-6 Mating connector (customer) Tyco-AMP 3-1437290-7 Mating crimp contact (customer) Tyco AMP 3-1447221-4 Video connector M12 round connector, female, 5-pole, B-coded acc. to EN 61076-2-101 Ethernet connector M12 round connector, female, 4-pole, D-coded acc. to EN 61076-2-101 Connector pinout see chap. 9. 7 Software 7.1 Operating System Linux 2.6.28 7.2 Application Programming Wachendorff Projektor Tool Optional: Codesys-Tools (3.5) Optional: ISO-VT (Q4/2012) Optional: C/C++ 8 Testing and Verification 8.1 CE-Compliance EU Directive 2004/108/EC (EMC) according to EN 12895: Industrial Trucks Electromagnetic compatibility EN 13309: Construction machinery Electromagnetic compatibility of machines with internal electrical power supply EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria 8.2 e1 - Type approval EU Directive 72/245/EWG (Jan-2013) 8.3 Protection Level (IP Code) IP 6k5 according to ISO 20653: Road Vehicles Degrees of protection (IP-Code) Protection of electrical equipment against foreign objects, water and access 8.4 Electrical Requirements 12 and 24V-Systems according to: ISO 16750-2: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Electrical loads ISO 15003: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions 8.5 Mechanical Requirements According to ISO 16750-3: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Mechanical loads, Code L ISO 15003: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions o Mechanical Shock: Level 2 o Random Vibration: Level 2 o Sinusoidal Vibration: Level 2 8.6 Climate Requirements According to ISO 16750-4: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Climatic Loads o Operating Temperature Range: -30 +65 C o Storage Temperature Range: -40 +85 C ISO 15003: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions

9 Pinout 9.1 Main connector pinout pin no. assignment description 1 VCC supply voltage +; terminal 30 2 Ignition Input ignition input; terminal 15 3 GND supply voltage - ;terminal 31 4 CarGND Car GND 5 n. c. Not connected 6 n. c. Not connected 7 n. c. Not connected 8 CAN1H CAN 1 high 9 CAN1L CAN 1 low 10 CAN2H CAN 2 high 11 CAN2L CAN 2 low 12 USB_VCC USB +5V supply 13 USB_GND USB supply GND 14 USB_D- USB Data - 15 USB_D+ USB Data + 16 RS232 RxD RS232 receive data 17 RS232 TxD RS232 transmit data 18 RS232 GND RS232 GND 19 A/DI3 analog/digital input 3 20 A/DI1 analog/digital input 1 21 A/DI2 analog/digital input 2 22 A/DI4 analog/digital input 4 23 SERV_EN service enable 24 DO3 digital output 3 25 DO1 digital output 1 26 DO2 digital output 2 view on rear side of the A6

9.2 Video connector pinout Round Connector, 5 pins, M12 1 VidSig+ 2 Mirror 3 Camera+ 4 Camera - 5 VidSig GND Video- Connector, M12, female, 5 pins, b-coded, view on rear side of the A6 9.3 Ethernet connector pinout Round Connector, 4 pins, M12, acc. To IEC 61076-2-101 1 TD+ 2 RD+ 3 TD- 4 RD- Ethernet Connector, M12, female, 4 pins, d-coded, view on rear side of the A6