Cube YY-0420/0430 Technical Instruction

Similar documents
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

CONTENTS. 1. Motherboard installation Install 5¼ and 3½ drives Install PCI components Case fan setup...5

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

(Hardware and case keys are provided inside the chassis storage compartment.)

120Ra-1 Pentium III Processor Installation Insert

Upgrading and Servicing Guide

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

RM414 User s Manual. Preliminary Release

AK35 5U Tower Chassis Kit

Veriton M678G/S678G. Product End-of-Life Disassembly Guide

Installing and Upgrading Memory and Virtual Private Network Modules

Rack Installation Instructions

Managing Individual Components

Dell Inspiron N5110 Service Manual

ALIENWARE AURORA SERVICE MANUAL 01/

SCSI Cable Installation Instructions

Installing the Cisco MDS 9020 Fabric Switch

Upgrading and Servicing Guide

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

HP ProLiant DL165 G7 Server

IBM. Rack Installation Instructions

742S 742i SC742 CHASSIS USER'S GUIDE

Installing the Cisco SFS 3504 Server Switch

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Computer Assembly (Installing Mother Board & CPU)

RPC-600/610. Industrial Chassis USER' Manual

Hardware Replacement Guide

Dell Inspiron XPS and Inspiron 9100 Service Manual

Upgrading and Servicing Guide

Upgrading and Servicing Guide

Chenbro. ES34169 Chassis User s Manual. April / 2 /

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Installing the Cisco Unified Videoconferencing 3545 MCU

1. Unpacking the System

Rack Installation Instructions

R-4 Bulldozer user s Manual

Dell Precision Workstation T7610 Owner's Manual

LVN5200A-R2, rev. 1, Hardware Installation Guide

Oracle <Insert Picture Here>

EBC Mini-ITX Chassis for High Power Consumption Applications Version: 1.0. Quick Installation Guide ABOUT COMPATIBLE SBC/COOLING KIT

Replacing/Upgrading Mac Pro Processors (Early 2008)

AR-IPC14P Industrial PC Chassis

To connect the AC adapter:

Upgrading and Servicing Guide

EVGA assumes you have purchased all necessary parts needed to allow for proper system functionality.

Hard Drive user manual

Hard Drive user manual

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Quick Installation Guide

H3C S12500 Routing Switch Series

Allworx 24x Service and Troubleshooting Guide

Dell Precision Tower 7910 Owner's Manual

SySTIUM TM TECHNOLOGIES Model 215

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

3. Install Graphics/PCIe Cards in NA255A 8

Installation Job Aid for Avaya Virtual Services Platform 8400

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Table of Contents - 1. Predator PO3-600 User s Guide

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

WMC-402M. Wallmount Chassis User Manual

RIOTORO CR1080. Installation Guide

Replacing the SATA PCI Controller Card

Installing a New Solo 1150 Hard Drive

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

easyraid Q24P2-U4R4 Hardware Manual

Upgrading and Servicing Guide

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

Hard Drive/Solid-State Drive Replacement Instructions

System Storage EXP3000 Rack Installation Instructions

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6417, 6418, 6449, 6453

Replacing the Gateway M305 Optical Drive

G-MAX TM. ATX Series User s Manual

NZXT. CRAFTED GAMING ARMOR. TRINITY. User s manual NZXT. 1

D-Storm Series. High-end Rackmount case. Installation and User Guide. Copyright 2004 istarusa, Inc.

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

SC832/SC833 CHASSIS USER'S GUIDE

Purepower 500W. Table of contents. Note : 1. Introduction Installation

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

P160 User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

Dell Latitude V710/V740 Service Manual

Megatouch FORCE Monitor Chassis Board Replacement

TravelMate 6493 Series Disassembly Instruction

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Use flat head screws for the out side of chassis and pan head screw for inside of chassis.

CHASSIS INSTALLATION GUIDE

CSE-M14T Mobile Rack USER'S GUIDE

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

This is a learning module for a specific Learning Outcome as stipulated in the HSP that is :

INFORMATION AND COMMUNICATION TECHNOLOGY

WEASEL N/B MAINTENANCE

Installing and Managing the Switch

16Hi HARDWARE INSTALLATION GUIDE

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

4.1 General. 4 Replacement Procedures

Replacing the Gateway M405 Keyboard

H4 Series Hardware Replacement Guide

Transcription:

Cube YY-0420/0430 Technical Instruction Contact Information YEONG YANG Technology Co., Ltd. Address 12F, 778-1, Chung Cheng Road, Chung-Ho City, Taipei, Taiwan, R.O.C. Telephone +886-2-3234-0020 Fax +886-2-3234-0014 Email: info@yeongyang.com.tw USA Contact: GIGACASE Corp. Address 18459 E. Railroad St., City of Industry, CA 91748, U.S.A. Telephone +1-626-854-9289 Fax +1-626-854-1896 Email info@yeongyang.com Eruope Branch: YEONG YANG Technology GmbH Address: Mühlenhagen 130, 20539 Hamburg Germany Telephone +49-040-780461-0 Fax +49-040-780461-11 Email info@yeongyang.de - 1 - I. INTRODUCTION 1. This Cabinet YY-0420/0430 is a server cabinet configured on redundant power supply which takes using as a Server/Raid system. And more, the excellent thermal solution, compatibility of full size AT, Baby AT, ATX motherboard and Xeon CPU makes it strongly supports the most complicated server tasks. 2. Component Checklist If assembling this chassis by yourself, it is important to prepare all the chassis components before starting. This will save a great deal of time by not having to hunt down components. The following checklist provides a guideline as to the necessary components for a chassis. Standard Components Chassis YY-0420/0430 Power Supply Redundant or ATX PSII Single P su Cables LED, Power/Reset, and audio speaker cable Speaker 2.25 Audio speaker User s Manuals Hardware Reference Guide and Power Supply User s Manual Optional Components (you may purchase from YEONG YANG) Cooling Fan 9cm cooling fan, 1pce - 2 -

Cooling Fan 12cm cooling fan, supports up to 3pcs Power Supply Redundant or ATX PSII Single P su HDD Frame w/9cm cooling fan Occupy 3*5.25 device for 5* HDD use SCA2, ATA or SATA RAID module with back plane EMI Filter EMI filter for tail gates 3. Features The followings are highlight to this cabinet s many features. For additional features and details, please contact with us directly or visit our updated web site with this cabinet package. Processor: Available for Intel PentiumIVand Xeon CPU Motherboard: Supports Full size AT and ATX/ATX extended form factor. Raid Solution: Supply flexible and expandable configurations of Server/Raid system. Device Bays: Supports up to 8 drive bay Thermal Solution: Provides up to 1 set of 9cm and 3 sets of 12cm cooling fans Front Panel Control: Snap in front bezel for quick accessibility, with Power switch, Reset switch, Power LED, Power error LED, HDD LEDs and Key lock. Security: Security by 100 key combinations. 4. Safety and Warning Observe the following safety instructions any time you are connecting or - 3 - disconnecting devices to this cabinet. WARNING: An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. When adding or removing any additional devices to or from the system, ensure that the power cables for those devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device. Use one hand, when possible, to connect or disconnect signal cables to prevent a possible shock from touching two surfaces with different electrical potentials. To prevent electrical shock hazard, disconnect to power cable from the electrical outlet before relocating the system. WARNING: This product is equipped with a three-wire power cable and plug for the user s safety. Use the power cable in conjunction with a properly grounded electrical outlet to avoid electrical shock. 5. Tools Required A few items are needed to install or remove the components in this chassis. - 4 -

n Phillips (cross) screwdriver n Standard (flat) screwdriver n Anti-static wrist strap outlet. To reduce the risk of electrical shock or damage to your chassis, do not bypass the grounding plug. 6. Preparation 1. Unpack your chassis, do not connect the power cord. IMPORTANT: Most chassis use an AT power supply that has a fixed ON and OFF switch located on the front. This chassis uses an ATX power supply that is normally OFF until an electrical signal is given to the power supply through a momentary switch located on the front of the chassis. There is always a standby power in the power supply in order for ATX power supply features to work, and therefore removing the power cord is necessary to prevent electrical shocks when working on the chassis components. 2. Unlock the padlock if one is used. This chassis is equipped with a lockable front door to prevent unauthorized access. Open the side panel. 3. Set the power supply input voltage to either 115V for 110-120V areas or 130V for 120-140V. CAUTION: The voltage must be set correctly or damage may occur. 4. Connect the included power cords to the chassis power supply. 5. Connect the chassis to a grounded (three pronged) AC power source such as an UPS or power strip (preferably with surge protection). WARNING: This chassis is designed for connection to a grounded - 5 - - 6 -

II. System Assembly and Disassembly 2. Side Panels 1. Front Panel There are two screws in each side. The chassis security function is guaranteed by the key lock and the front panel. To disassembly the front panel, we should ensure the key lock is placed in ON position. Use one hand on the bottom of front panel, hold up, and the other hand on the top, pull out. The front panel will be open from top, toward your body. Release the screws, pull out the side panel from rear side to front side. To install the side panel, slide in the side panel firmly into the track and tighten the screws. To assembly the front panel, plug the three hooks in the bottom of front panel, into the chassis body and snap the springs of front panel in. 3. Fixed Storage Devices To install 3.5 FDD drive or HDD Drive, it should release the 3.5 device cage from the cabinet body first. The 3.5" device cage is held by two screws on each front side, release the screws by screwdriver. - 7 - - 8 -

Fitted the 3.5 FDD or HDD drive with 3.5" device cage by screws on both sides. If there is any drive space empty, the spacer is available and used to cover. Press the device inward, to take the slides in along the rail of left side. Fasten by one screw on front side. Fasten right side of the device by two To install 5.25 HDD or CD-ROM, it should release the 5.25 device frame from the cabinet body first. The 5.25"device frame is held by three screws, one on front side and the other two on right side screws. 4. Cooling Fan mounting Take the metal slide out from Fasten fans from outside of chassis by screws. 5.25"device frame, and ensure the metal slide should be fitted with device in position. 5. Power Supply Mounting - 9 - - 10 -

7. Rolling Wheel Constructed There are four rolling wheels could be used in this cabinet, each wheel could be and must to be fastened tightly by two screws. Mounting and unmounting the power supply must be done from the inside as shown left. Four screws are used to secure the power supply to the cabinet back side. To avoid the unexpected moving and vibrating, two lockable wheels could be set on by pushing the locking pad. III. System Components 1. Cabinet Front Side 1.1 Chassis Security To protect the chassis from unauthorized intrusion, the cabinet front panel can be locked with the built-in key lock. 1.2 Chassis Panels There are two identical side panels on this cabinet, one on each side. Each panel is secured by four screws on the front of the cabinet. 1.3 Message LED Description There are 16 LEDs show on the middle of front panel. The first LED represents the power on message of system active (connect to motherboard), the second LED shows power supply status (connect to redundant power supply), the other 14's are represented the HDD situation. 2. Cabinet Back Side The back side of the cabinet is provided to show the back exterior components of this cabinet. That will be including, - 11 - - 12 -

2 x DB25 Port 2 x DB9 Port 2 x SCSI (68 pin) 7 x ID Ports Redundant Power Supply System Fans drive bays. 3. Cabinet Inside When the left panel removed, you should see the space of motherboard and 12 cm cooling fans, 3.5" drive frame. Right side provides space for redundant power supply and 8x5.25 4. POWER SUPPLY Please read its individual manual - 13 -