ASTi Axis Local Distribution Module Technical & User Guide Document: ASSY-01-UMLD-UG-1

Similar documents
ACU2 Technical User Guide. Document: DOC-HW-ACU2-UG-L-1

ACU2 Technical User Guide. Document: DOC-HW-ACU2-UG-L-3

IA Installation Overview. Document: DOC-IA-NA-OV-E-1

ASTi Telestra 4 Quick Start Guide. Document: DOC-01-TEL4-QSG-1

ASTi Secure DACS User Guide. Document: DOC-01-SD-UG-1

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

ASTi SYNAPSE Cold Start and Installation Manual Document: DOC-01-SYN4-CSI-1

87421/22A Power Supply. Operating and Service Manual

4170 POS System Installation Guide

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

FieldServer X-25 Start-Up Guide

ASTi 8-Channel Waveform Synthesizer User Guide Document: DOC-01-8AFA-UG-1

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Models HP Z VR Backpack G1 Dock

QuickSpecs. HP 1x4 USB/PS2 KVM Switch. HP 1x4 USB/PS2 KVM Switch. Models HP 1x4 USB/PS2 KVM Switch

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

High Voltage Power Supplies

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

USER GUIDE. For additional languages, please visit LandingZone.net/user-guides

Rack Power Distribution Unit AP7530, AP7540

BACnet Router Start-up Guide

Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies

Cabinet Interface Device

User Manual for Models HG2, HP2, PSM and PSL. Version 1.0. User Manual. June 18, Version 1.0 P/N??? Page 1/17

Rackmount Keyboard Installation Instructions. Revision A A-0000

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

SERVICE MANUAL MODEL SSW-520-F

Mounting/Security HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve v2

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

First of all, thank you for purchasing R2W series redundant power supply.

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SERVICE MANUAL MODEL SSW-321-X

Agilent 66000A 1200 W DC Modular Power System, GPIB

BACnet Router Start-up Guide

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

RPX Series USER S MANUAL

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

DSP 4x4 Operation Manual

User Manual. CV-401 / 801 / U Rackmount PS/2 KVM Switch

IBM. Rack Installation Instructions

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Thunderbolt 3 Multiport Dock USER MANUAL UH7230

Sorensen XT Series W A. 60 Watt Linear Performance DC Power Supply V. Low noise and ripple. Excellent line/load regulation

Installation and Configuration Guide

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Power Supply (48Vdc, 2.5A)

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

RTD Embedded Technologies, Inc.

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

ASTi ACE Studio VM Quick Start Guide. Document: DOC-01-ASVM-QSG-4

1-36V, 0-3A DC Power Supply

The OmniCube User Manual

HDMI Optical Extender USER MANUAL VE882 / VE892

RS422 PORT SWITCHER REMOTE CONTROL PANEL

Quick Start Guide. Dual USB Wall Charger with PD Charging, (x1) USB-A Port and (x1) USB-C Port. Model: U280-W02-A1C1

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Operation/Reference Guide MVP-TDS. Table Docking Station for MVP-7500/8400 Modero ViewPoint Wireless Touch Panels. Touch Panels & Accessories

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

USB Ranger 110/410 User Guide

HDEXT50M USER MANUAL Extend HD Signals over CAT 5/5e/6 up to 164ft.(50m) All Rights Reserved Version: HDEXT50M_2017V1.2

Sunlight Readable Touch Monitor. Industrial Touch Monitor. Sunlight Readable Series. CS-100/M1000 Series

User Manual. N Series 1U LCD Keyboard Drawer 17", 19" screen size. Models NRKD-KVM-17 / 19 Series. Models NRKDS-KVM-17 / 19 Series

Innovative Circuit Technology Ltd.

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Black & White Camera Kit with Multiplexer Video Surveillance System

60 GHz Wireless Dock Basic Model

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

Dell Thunderbolt Dock TB15 User Guide

Single-Output 2000 W GPIB

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

Technology Corporation. ADDERLINK X SERIES X2-MultiScreen

Broadband Automatic Disconnect Switch. User Manual

MODEL USBP-DIO16RO8. DIGITAL INPUT/OUTPUT BOARD w/8 ELECTROMECHANICAL RELAYS USER MANUAL

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

User Manual SP2H2A-H2. HDMI 2.0 1x2 Splitter with Audio Breakout. All Rights Reserved. Version: SP2H2A-H2_2018V1.0

DL-S41 Installation Guide

User Guide. USB/Ethernet Charging Cradle. Mobility Electronics, Inc Via Pasar, San Diego, CA 92126, USA

McAfee Network Security Platform

INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N

SERVICE MANUAL MODEL SSP-350-X

TESLA 1U GPU COMPUTING SYSTEMS

TRC-190 User s Manual

Dolphin DXE410 Expansion Chassis

12-Bay Docking Station Standard Battery Version User Guide

MiR Bluetooth Box. Technical Documentation

Translator VGA To DVI Converter/Scaler

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Click Desktop Kit. Click Desktop Kit

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Transcription:

ASTi Axis Local Distribution Module Technical & User Guide Document: ASSY-01-UMLD-UG-1 Advanced Simulation Technology inc.500a Huntmar Park Drive, Herndon, Virginia, 20170 USA Revision E (February 2010)

Product Name: Axis ASTi Axis Local Distribution Module Technical & User Guide Copyright 2010 ASTi Restricted Rights: Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. This material may be reproduced by or for the U.S. Government pursuant to the copyright license under the clause at DFARS 252.227-7013 (1994). ASTi 500A Huntmar Park Drive Herndon, VA 20170

Table of Contents Axis General Information..................................................... 1 Description... 1 Features... 1 Figure 1: Telestra Hardware Connection and Functionality Diagram...1 Physical Specifications....................................................... 2 Figure 2: Axis Front Panel...2 Figure 3: Axis Rear Panel...2 Dimensions... 2 Weight... 2 Module and Cabling Requirements............................................. 3 Power Requirements... 3 Figure 4: Axis Power Supply Options...3 Temperature & Humidity Ranges... 4 Power-On Ordering Requirements and Lost USB Devices... 5 Installation USB Cabling & USB Ports... 5 Axis Indicator LEDs......................................................... 6 Figure 5: Axis Rear Panel Indicator Light...6 Figure 6: Axis Front Panel Indicator Lights...6 Memory Devices............................................................. 7 Mounting Options........................................................... 7 Figure 7: Axis Mounting Template...7 Troubleshooting............................................................. 8 Warranty Information....................................................... 9 Repairs and Returns......................................................... 9 Disclaimer and Warnings..................................................... 9 i

ii

Axis General Information Description The Axis provides connection and distribution for ASTi USB-based peripheral devices local to the Telestra platform. The Axis may support up to eight (8) Iris devices. Features Four (4) Type A USB connections One (1) Type mini-b USB connection to Telestra Figure 1: Telestra Hardware Connection and Functionality Diagram Copyright 2010 Advanced Simulation Technology inc. 1

Physical Specifications AXIS Out A Out B Out C Out D Advanced Simulation Technology inc. www.asti-usa.com Figure 2: Axis Front Panel AXIS In Power +15VDC Advanced Simulation Technology inc. www.asti-usa.com Figure 3: Axis Rear Panel Dimensions 5.5 wide x 1.53 high x 6.0 deep Allow at least 2 or more of space to the front and rear of module for cable access and clearance. For detailed dimensions, refer to drawing CDHW-AU-001. Weight Axis only: 1.5 lbs. Axis with power supply: 2.25 lbs. 2 Copyright 2010 Advanced Simulation Technology inc.

Module and Cabling Requirements Power Requirements Input to PSL-UM-001 Output of PSL-UM-001 Power connector 100-240 VAC, 50-60 Hz, 1.5Arms (120VAC), 0.75Arms (240VAC) 15 VDC at 2.5A max, < +/- 5% voltage regulation, < 150 mv max voltage ripple Inside Diameter 0.100", Outside Diameter 0.218", bushing 0.219, locking, center positive The Axis module can be powered by an individual power supply (included at shipment), or by ASTi s Power Distribution Module (sold separately). Iris or Axis PSL-UM-001 Individual Power Supply OR PS4L-UM-001 (Power Distribution Module) Standard IEC Female Power Connector Power Out Power Out Power Out Power Out +15VDC +15VDC +15VDC +15VDC Figure 4: Axis Power Supply Options The power adapter inlet connector is an IEC320 type C14 or C8, requiring a matching cordset equipped with an IEC320 C13 or C7 connector (female line cord). Country-specific power connectors must be acquired separately for international use. Other types of power supplies may be used, given that the power output is 15 VDC, 800mA, with the properly fitting power connector. Copyright 2010 Advanced Simulation Technology inc. 3

Temperature & Humidity Ranges Operating temperature range +10 C to +40 C (50 F to 104 F) Operating max. temperature gradient 20 C (68 F) per hour Operating humidity range 10% to 90% non-condensing Storage temperature range -10 C to +70 C (14 F to 158 F) Storage max. temperature gradient 30 C (86 F) per hour Storage humidity range 5% to 95% 4 Copyright 2010 Advanced Simulation Technology inc.

Power-On Ordering Requirements and Lost USB Devices The USB audio distribution architecture has specific requirements regarding the power on sequencing of devices in order to achieve a working system. The Telestra processor system must perform a discovery process in order to find all the devices that are connected, and hence this system is started last in the sequence of elements. The discovery process runs as part of the system framework boot process, or it is manually initiated from RMS, by clicking the Hardware tab, and then the Reset USB network link. Prior to this all other elements of the USB sub-system must be connected, and powered on. Note that the Prism/Spectrum extender architecture should be powered on before or simultaneously with the Iris audio interface units. If any element of the USB sub-system is powered off and then back on again without rebooting the Telestra processor, or initiating a manual USB discovery, then the result will be that those devices are lost to the system, and will no longer process audio. The most effective way to check for this condition is to look at the RMS system, select the Hardware tab, and then the Layout tab. Any Iris units that were connected at the time of system boot and have been subsequently powered off will show up with a red X through the device. If profiling is turned on (see Telestra 3 User Guide for details), then any device that is not active on the USB sub-system will be reported with a red X. To recover from this situation, power on the required USB devices (Prism devices first, Iris devices last), and then either reboot the Telestra, or initiate a manual USB re-discovery using RMS. If using RMS, once the re-discovery process has completed, it will be necessary to reload the model. Installation USB Cabling & USB Ports For complete information on connecting Telestra USB devices, see the Telestra USB Device Connections Matrix document (ASSY-01-UMCX-IN-1). Copyright 2010 Advanced Simulation Technology inc. 5

Axis Indicator LEDs Red Power LED Figure 5: Axis Rear Panel Indicator Light The red LED on the rear panel of the Axis module will light when power is applied to the unit. Upper Green Out A Out B Out C Out D Lower Yellow Figure 6: Axis Front Panel Indicator Lights The upper green LED will light when the connected USB device (usually an Iris) has been properly identified by the software on the Telestra platform. The lower yellow LED will light when there is a USB-related problem. 6 Copyright 2010 Advanced Simulation Technology inc.

Memory Devices Micro controller internal RAM EEPROM Mounting Options Flush mounting to a flat surface is possible.þ Refer to the full sized template below. The three hole pattern on the mounting plate is compatible with NS-35 DIN rail mounting hardware adapter (sold separately). Figure 7: Axis Mounting Template 1U 19 shelf rack mount kit (for up to 3 units), ASTi part number RMK-UM-001. Copyright 2010 Advanced Simulation Technology inc. 7

Troubleshooting All USB devices require ASTi cable "CA-UA-UMB-X", where X stands for length, for correct operation. For more information on connections refer to Telestra USB Device Connections Matrix document (ASSY-01-UMCX-IN-1). Symptom: All LEDs are off. Possible Cause: No power applied to unit. Remedy: 1. Check that power cable is connected to Axis. 2. Check that power supply unit is plugged in. Symptom: An Iris is connected to the Axis, and the corresponding device LED is off, or the ASTi USB device fails. Possible Causes: 1. The software is not running. 2. The Iris is malfunctioning. 3. The Axis is malfunctioning. 4. The cable between the Axis and Iris is faulty or not fully connected. Remedy: 1. Make sure the Model is running on the Telestra system, and the Iris device has been detected. If not, reset all devices in software. 2. Unplug the Iris device from the Axis and reconnect. 3. Connect the Iris to a different Axis (or Prism/Spectrum, if possible). 4. Restart the Telestra system. If the device does not become operational, use another USB cable and restart again. If the device continues to fail, contact ASTi. 8 Copyright 2010 Advanced Simulation Technology inc.

Warranty Information The equipment is warranted for a period of one (1) year following purchase. Repairs and Returns If it becomes necessary to return equipment to ASTi please observe the following instructions: 1. Obtain an RMA number through ASTi s website: http://www.asti-usa.com/support/ 2. When packaging the equipment in question, make sure it is well protected. The device should be properly enclosed in an antistatic bag to prevent possible ESD damage. Failure to properly package the equipment during shipping could void the warranty. 3. Do not include accessory pieces such as rack mount kits, power supplies or software. Only send items that do not work. 4. The shipping label must include the RMA number. 5. Include a description of the problem, point of contact, phone number, return address and unit serial number(s). Failure to include this information could extensively delay the return of the equipment. 6. If an RMA number is not used within sixty (60) days of issuing date, the request data and number issued will be closed and designated as unused. 7. Any items received from customers without RMA numbers or appropriate contact information included with shipment will not be tested. After sixty (60) days, ASTi reserves the right to scrap all hardware received in this condition. 8. If the equipment is not under warranty a Purchase Order will be required to cover the cost of any repairs. ASTi will provide a quote for all non-warranty repair items. 9. Equipment will be shipped back using Federal Express, unless otherwise directed. If the repair is non-warranty then shipping charges will be billed. Disclaimer and Warnings Connect only ASTi-approved devices to the USB ports. Attempted use of non-asti USB devices may result in equipment damage. Do not use commercial extender cables with ASTi USB devices. There are NO user serviceable components in this device. Opening the chassis will void the warranty. Copyright 2010 Advanced Simulation Technology inc. 9