VS-Link. Dos Version. CB Electronics

Similar documents
CB ELECTRONICS. P2MMC RS422-Midi Machine Control Interface

CB ELECTRONICS TC-4 PORTABLE LTC READER/GENERATOR

Pec - Direct Remote For DAW's (Revision 2 Software)

Euphonix Machine Control Systems

Pec - Direct Remote For DAW's (Revision 2 Software)

Using the ProTools PD-1 Session Template

* Option 1... High Profile Jog Wheel

Use with the TMC-1Reference

USB422V. Dual RS-422 USB Interface with Video and GPO. Main Features

Q2Midi Convert Cue Lists to Midi Files

CB Electronics PDStem Windows/Mac Stem Definition s/w

Installation and Operating Instructions

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99

TC-5 Generator/Reader/Converter LTC-Midi-USB

Auto Digitizing Media

RS232/RS422 INTERFACE SETUP MANUAL FOR PHV Series High Voltage POWER SUPPLY Document: Rev A

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips.

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183)

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

TURBODRIVE USER GUIDE

MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays

TRANSCEIVER DATA PROGRAMMER TDP-136 INSTALLATION & OPERATING INSTRUCTIONS. Document No. 00RE277 Rev. C FEB Technisonic Industries Limited

Data Capture System for Windows. Documentation. TSW Automation, Inc Robertson Ave. Nashville, TN phone: fax:

Personal Directory PC Utility Reference Guide

CTC Load Utility TM User Guide

ALERT2 - Decoder Programming Software Ver. 1.00, MS-DOS.

Software Upgrade v 2.0

Personal Directory PC Utility Reference Guide

Instructions for installing software to the hard drive; Instructions for running the software under Windows 95 and NT;

menu of icons which you can select which item you want to use to startup the computer.

CB Electronics SR/MR/RM User Guide

ISDN Console Setup Utility User s Guide

YAMAHA 02R96 DIGITAL AUDIO MIXER

PAGEPAC PLUS CONTROLLER CONFIGURATION PROGRAMMING GUIDE (V )

MLP (Multi-Link Programming) SOFTWARE

3980xpi/3980/3900 V8.2 User Notes

Tait Orca Download and Configuration Application

Configuration Cloning for LW3 Devices

Access Control System

Click-A-Tune. User Manual

E SAS Serial Acquisition System Manual E Ver 6.03 January 3, 1998

IBIS-R+ Configuration and parameter setting software for Digitric 500 and Protronic 100/500/550. Operating manual 42/ EN Rev.

Norstar Manager Reference Guide

CF2SCSI Disk Bridge User Guide

Remote Display User Manual

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

960H H.264 DVR Setup Guide

PCard2SCSI Flash-Tape User Guide

User Manual Revision: A04 June 23, QuEST Rail LLC.

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

Lite H.264 DVR Setup Guide

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Simplex 4190 TrueSite Workstation (TSW) Software Upgrade Instructions

Getting Started Version 1.0

Prizm Mux Monitor (PMon) User Manual. March 13, Rev. 2.1

AMS COCKPIT USERS GUIDE. AMS Cockpit Version 1.1 USERS GUIDE

Fastrack Release Notes Version 3.5X60

721EX Access Controller Installation

JNIOR Series 3. Serial-to-Ethernet Manual. A Network I/O Resource Utilizing the JAVA Platform. Release 3.0. NOTE: JNIOR OS 3.1 or greater required

Futronix Interfacing to Crestron

VAIO Digital Studio Computer User Guide PCV-RX540

Model: LK7000. Programmable Matrix Keyboard. 119 Keys with Built-in Scanner and MSR USER MANUAL

Appendix A Example Programs

SIO2MicroSD. Written by Don Peruski Document updated 12/31/12

Operating Instructions

ToroPCTM User s Manual

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

BAUMÜLLER OPERATION SOFTWARE. Technical description and operation manual E

Installation and Programming Manual

User Guide. AV-HS410 Plug-in Software ENGLISH

Standard H.264 DVR Setup Guide

CyberComm Pro Data Acquisition Software Installation & User Guide

Show Designer 1. Software Revision 3.11

CA400S INSTALLATION INSTRUCTIONS

VP2000 Reference Guide Rev. 1.0 Mar COPYRIGHT Eurotech S.p.A. All Rights Reserved.

MMI6070 Quick Start Guide

BlackBerry 7100v from Vodafone Installation Guide

C218 Turbo User s Manual

Model: KB1700. Programmable Keypad. 17 Programmable Keys USER MANUAL

User s Manual CAP 531*1.5 Configuration and Programming tool

Internal Commands COPY and TYPE

USER GUIDE. to the CP130. Thermal Printer

Quick Start Guide to the SmarTouch TM Controller

SuperNova. Screen Reader. Version 14.0

MAX197 Evaluation Kit. Evaluates: MAX197/MAX199. Features

PC100. Operating Manual. Enclosed Disk Art.-No.: Programming-Software for Compact-Encoder

M2500 Engine Controller Configuration Manual

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

SVMi-8E/SVMi-16E Installation

MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual

IP Controller INSTRUCTIONS

Series III Programmer Installation Manual

TT Graph (for Windows) Manual Table of Contents

4/0 EASY control relay

Copyright 1983 VisiCorp All Rights Reserved. Printed in U.S.A.

NUBIX H.264 DVR Setup Guide

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

This bulletin describes how to setup calypso so that you can send and receive encrypted s and/or digitally sign your s.

Transcription:

CB Electronics VS-Link Dos Version CB Electronics Loddonside, Lands End House, Beggars Hill Road, Charvil, Berks RG10 0UD, UK Tel: +44 (0)118 9320345, Fax: +44 (0)118 9320346 URL: www.colinbroad.com E-mail: support@colinbroad.com

CB ELECTRONICS Loddonside, Lands End House, Beggars Hill Road, Charvil, Berks RG10 0UD, UK Tel: +44 (0)118 9320345, Fax: +44 (0)118 9320346 1.00 HELP! 1.01 Log Onto the A: Drive 1.02 <Enter> 1.03 Directory & Sub-Directory 1.04 Windows & DOS 1.05 Black Box Developments 1.06 Hardware Requirements 1.07 Using Serial port 2 (Com 2) 1.08 [F9] CONTINUE / [F10] EXIT 1.10 INSTALLATION 1.11 BACKUP 1.12 Connection Cable 1.13 RS232 / RS422 1.20 STARTUP 1.21 STARTUP SCREEN 1.22 ADR FILE BASE DIRECTORY 1.23 JOB SUB-DIRECTORY 1.24 EPISODE SUB-DIRECTORY 1.25 WHY SO MANY DIRECTORIES 2.00 [F2] Send EDL File 3.00 [F3] Send VS file 4.00 [F4] Send Text File 5.00 [F5] DOS 7.00 [F7] Delete All 8.00 [F8] Wipe 9.00 [F9] Data VS-Link (DOS Version) CONTENTS 8.00 Commands 8.1 [F8] Wipe On/Off 8.2 [F9] Data Line On/Off 8.3 Del Delete current cue 8.4 +/- Increment/Decrement current cue 8.5 Up/Down Next / Previous Cue 8.6 Space Capture New Cue, Enable Data Line CB ELECTRONICS Capture 1

1.00 HELP! VS-Link runs on any PC compatible computer, this section answers some common questions on the operation of the computer and or DOS. 1.01 Log Onto the A: B:, or C: Drive To do this, insert the Disk into the A: or B: drive, then type A: or B: followed by <Enter> your screen should then display a A: or B: prompt. 1.02 <Enter> When you see <Enter> written in this document it refers to the large key either labled enter or with a symbol which looks similar to :- <- 1.03 Directory & Sub-Directory In the same way as you arrange your paperwork in separate files, shelves and drawers your information should be stored on the computer in separate directories and sub-directories. This allows you to find information quickly and easily. EG. This manual is filed on my hard disc in a Sub-Directory called "MANUALS" which is in the "TEXT" directory. Under DOS all directory names must be terminated by a "\" thus to edit this manual I type "EDIT \TEXT\MANUAL\VSLINK" where VSLINK is the name of the manual. The first "\" tells DOS to look in the main or ROOT directory on the current disk. If you are the type of person that puts all books, papers etc in a large box then you will not need directories or sub directories. I once came across someone with over 600 entries in the root directory, this meant that if he forgot the name of a file then he had to look through all 600 files to find the file he required. The vslink programs assumes that you wish to file your Video Streamer lists in individual subdirectories according to the program name. The program also supports multiple episodes of the same program. The main directory is called "VS" To change the between directories use the "CD" command, for instance all the files used on this program are stored in "\VSLINK", to change to this directory type "CD \VSLINK <enter>". 1.04 Windows & DOS This program are written for DOS and not for windows, the reason for this is that every IBM compatible is capable of running DOS but not every IBM will run windows. We have customers using our ADR taker program on original PC running 8088 s (The slowest processor). If you wish to run this program under Windows then a DOS window and run the program in that window. To setup an Icon under windows 3.1 use Alt-F (file), New, Program Item. This was written a number of years ago, look to our web site www.colinbroad.com for a windows version of this program. 1.05 Black Box Developments Black Box Developments have a windows program that runs the Video Streamer directly from Studio frame and other Digital Audio Work Stations. 1.06 Hardware Requirements This program will run on any PC compatible or on any computer running PC emulation. The speed of operation will vary with the speed of the computer but nothing else. The main setup allows you to specify a colour or B/W screen. 1.07 Using Serial port 2 (Com2:) In order to use Com2 start the program by typing VS com2. alternativly cop vs2.bat to you base directory as follows copy \vslink\vs2.bat \. 1.08 [F9] CONTINUE / [F10] EXIT CB ELECTRONICS Capture 2

On most menu s within this program [F9] CONTINUE is used to continue with the selected process, [F10] EXIT is used to abort the process. 1.10 INSTALLATION Insert the disk in the A: or B: drive, log onto the A:/B: drive (type A:<Enter>), and then type INSTALL C: <Enter> assuming installation onto the C drive. 1.11 BACKUP. Once installed on the hard drive the files on the floppy disk may be used to back up the files on the hard disk. 1.12 Connection Cable between an IBM computer and the Video Streamers The connection to a IBM is made as follows:- Connector: 9 pin MALE D, screw lock. On rear panel. Data Format: 1 Start bit, 8 Data bits, 1 Stop bit, No parity Baud Rate: 9600 Standard: RS232 RS232 Interface cable:- CB Video Streamer Connector On Cable IBM PC Connector On Cable 9 pin D Male 9 pin D 9 pin D 25 pin D Function Bus (RS422) Micro-D New Micro-D Old Micro-A Function COM-1 COM-2 Tx Data- 2 2 2 Rx Data- 2 3 Rx Data- 8 3 3 Tx Data- 3 2 Ground 4 4 7 Ground. 5 7 Note: Change in ground pin between Old and New Video Streamers 1.13 RS232/RS422 RS232 is not designed to run over long distances, the connection on the later Video Streamer is switchable between RS-422 and RS-232. To use long cable runs you should change the link in the VS- 1 to RS-422 and use a RS-422-RS232 converter. We can supply one, K2systems also make one. 1.20 STARTUP When the program is installed a batch file called VS.BAT should be copied to the root directory of the drive onto which the program is installed. This may be modified as required or run as is by typing VS<Enter> from the root directory. 1.21 STARTUP SCREEN The startup screen shows the revision number. If you ring in for assistance please make sure that you have this information at hand. Hit any key other than <F10> or <Esc> to continue. 1.22 VS FILE BASE DIRECTORY As supplied the program will assume that "\VS" is the base directory for all edl s, if it finds a "\VS" directory then it use it. If not then the program will ask if it can make this directory. At this point either agree or specify the directory you would like to use. CB ELECTRONICS Capture 3

In our paper analogy this the drawer with which the lists are kept. 1.23 JOB SUB-DIRECTORY The program will then look for the current JOB directory, this is supplied as \ADR\JOBNAME please enter an appropriate name. Please note spaces are NOT allowed and a maximum of 8 characters may be used! In our paper analogy this the customer/job file. 1.24 EPISODE SUB-DIRECTORY If enabled a further sub-directory will be searched for and that is the EPISODE sub directory. See section 14.16 for further details. If episodes are enabled then an VS List called VS123 could be stored in the following location:- C:\VS\JOBNAME\EPISODE\VS123 1.25 WHY SO MANY DIRECTORIES Filenames are restricted to 8 characters + 3 extension characters, if the job, episode and reel number are all to be encoded into the file name then the name will not be very descriptive. At any one time you may be working on more than one job or episode, this helps you differentiate between them. CB ELECTRONICS Capture 4

2.00 [F2] Send EDL Format File Used to download a standard CMX EDL file to the Video Streamer, The program will use the Record in points as the cue values. For example, if you strip an EDL list of all the audio only edits you can then down load the video edits to the VS-1. The VS-1 will then insert a wipe on every scene change. 3.00 [F3] Send VS Format File When you have entered cues directly onto the VS-1, you can upload (Shift-[F3]) them and store them on the computer, Use [F3] to down load the stored cues to the Video Streamer. 4.00 [F4] Send TEXT File You can write a list of cues using a text editor (TextPAd, WordPad, NotePad) or save As text from a word processor (Word, WordPerfect). The only requirement is that the First cue should include the hours and that each cue starts on a new line, the first timecode value found in any line will be used. The timecode format should be HH:MM:SS:FF 5.00 [F5] DOS [F4] Opens a Dos window to run another program. 6.00 [F6] COPY [ F6 ] is used to copy a file from a the floppy in the A: drive to the current selected directory. 7.00 [F7] DELETE-ALL On depressing F7 you will be asked if you wish to save the current list from the streamer. hitting any key other than n will request a file name for the current cues. The file saved will be in the VS format. To upload this file at a later date use [ F3 ] Send VS. 8.00 [F8] WIPE The [F8] key may we used to enable and disable the Wipe. 9.00 [F9] DATA The [F9] key may be used to enable and disable the Data Line. CB ELECTRONICS Capture 5

10.00 Commands 10.1 [F8] Wipe On/Off Enable/Disable the Wipe, When the count down is enabled on the unit this command also disables the countdown. 10.2 [F9] Data Line On/Off Enable/Disable the Data Line 10.3 Del Delete current cue Delete the currently displayed cue. 10.4 +/- Increment/Decrement current cue Increment/Decrement the currently displayed cue 10.5 ^/v Next / Previous Cue Move to Next/Previous Cue, note if the timecode is running then the list will move with the timecode. 10.6 Space bar: Capture New Cue, Enable Data Line When the code is running the reaction time preset subtracted from the reader timecode before it is stored as a new cue. The reaction time is only subtracted when the code is running, when stationary code or no code is present at the reader input the timecode captured should be identical to the time displayed on the VS-1 reader display. 8,7 Setting the Reaction time The reaction time may be set as follows Mode 0) Mode Selection Screen 5) System Options 9) More 1) Set Reaction Time CB ELECTRONICS Capture 6