a highly accurate measurement tool that ensures stable speed data

Similar documents
JLR-7600/7900 (D)GPS navigator

JMA-1030 Radar. the JMA-1030 is an easy to use radar that greatly supports your ship's handling by touch operation. since 1915

GPS COMPASS JLR-20/JLR-30

OMNI COLOR SCANNING SONAR JFS-6880SERIES

Model: DS-60.

MARINE RADAR MARINE RADAR

JAN-7201S/9201S ECDIS

JAPAN RADIO CO., LTD.

JUE-251 FleetBroadband

MIC-2 Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

BEN Marine. Marine instrumentation

MIC-2 MKII, Multi-instrument DATA SHEET

Digital Indicator Solutions

7511 / / / 711 / / 731 / Preset 27

Technical specification Marine Master Clock

AlphaLine Repeater A new generation of displays.

Counting On Your Process Preset Counters

Continuous level measurement Ultrasonic controllers

IMPORTANT NOTES HOW TO USE THIS CATALOG PRODUCT SAFETY WARRANTY. This catalog details the general specification for your Carrot Products.

DINALOG A 144 x 36 A1400 Light-Strip Indicator

MCX08M2 Programmable controller

RST100 Alert & Tracking Solutions

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Black box radar High performance in a simple design.

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

TPC1. User s Manual. DYNASERVO INC.

HelmView Model HV750. Installation Manual Section 78

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

JLR-7500/JLR (D)GPS navigator

XBTGT2120 advanced touchscreen panel x 240 pixels QVGA - 5.7" - 24 V

HelmView Model HV750; HVS750. Installation Manual Section 78

Power Meter PowerMonitor 500

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

OPERATION MANUAL Model: NM501

Simplified information where and how you want it.

VIPEDIA-12. Cameo specification sheet. Product Description

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

XBTGT2120 advanced touchscreen panel x 240 pixels QVGA - 5.7" - 24 V

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

SM 3 SPEEDMOUNT COMPACT FULL-RANGE SURFACE MOUNT SPEAKERS SPEAKERS. Patented, concealed mounting system

Process displays For current and voltage

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

TM3AI4 module TM3-4 analog inputs

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

SITRANS F flowmeters SITRANS F US

MODCELL 2050R Single Loop Controllers

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

TM3DI16 module TM3-16 inputs

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

705 INSTALLATION MANUAL

Operation, Installation and Service Manual MASTER. 8 kn NAVIKNOT 350 E. Electromagnetic Speed Log

DM100 VDR. Voyage Data Recorder. Danelec systems Solid Safe Simple

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

Amplifiers, Counters, Timers & Controls

Fics-TPC1 Motion Controller. User Manual. Dynaservo Inc.

The Original Green LED Incorporated Digital Micrometer

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

TM3TI8T module TM3-8 inputs temperature

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TOXALERT MODEL AIR 2000

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Digital multimeters DMG

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

TM3TI4 module TM3-4 inputs temperature

DM100 S-VDR. Simplified Voyage Data Recorder. Danelec systems Solid Safe Simple

Clear Benefits of the KRAL Electronic.

Sorensen XT Series W A. 60 Watt Linear Performance DC Power Supply V. Low noise and ripple. Excellent line/load regulation

Micro Motion Model 7950 and Model 7951 Signal Converters

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

PowerView Model PV350 and PV380. Installation Manual Section 78

- NLS NAVIGATION LIGHT CONTROL

SMART PROGRAMMABLE RELAYS

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

BA/BS4S Temperature Sensor Installation & Operating Instructions

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Operator dialogue terminals 1

Keysight U8030 Series Triple-Output DC Power Supplies

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Circuit Breaker Analyzer & Timer CAT65

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Flow Measurement SITRANS F US Inline

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Explorer M310. Multi Instrument Installation and Operation Manual.

LED Controls. Lighting Controls. LED Controls

Transcription:

Photo by Damen JLN-205Mk2 Speed log RMS a highly accurate measurement tool that ensures stable speed data 4.5-inch high brightness display Dual color LED backlight Various display modes Large characters for easy read-out Accurate measuring and stable indication since 1915

Features Features The JLN-205Mk2 is a stable and highly accurate measurement tool to ensure stable speed data utilizing high frequencies ultrasonic waves. Dual LED backlight The unit incorporates many display modes readily available on a highly visible 4.5-inch LCD display. Besides the display being fully dimmable and having backlit keys, it features dual LED backlight (white and orange), making it easy to operate in various light settings on the bridge. Clear view Multiple display modes are available from the menu with main data displayed in large characters for easy reading. You can easily switch at your own convenience, particularly useful when a situation requires specific information. Transducer The transducer is compact and constructed of light weight moulded rubber, to minimize the effects on aeration, which allows stable and accurate operation. Gate valve Using an optional gate valve transducer allows for long-term cost saving and easy maintenance as dry docking is not necessary. Error free An ultrasonic beam is transmitted in fore and aft directions. At the same time, the hull motions such as rolling and pitching are detected and removed by simply measuring the difference of the Doppler shift reception signal, ensuring accurate and stable speed data, even in the roughest conditions. JLN-205Mk2 Speed log compact transducer and display

Operation Uniform operation In keeping with the company s philosophy of an easy to use Man Machine Interface, the new generation displays have allowed JRC s engineers to develop an exciting new software approach for uniform operation. 4.5-inch LCD Unit change Trip reset Menu Buzzer Cursor/Enter Power/contrast Dimmer Display Clear/Back Flexible data and dimmer share The display of the JLN-205Mk2 can be purchased separately as Multi Info Display (MID). It allows full NMEA0183 data share for up to 10 displays and can be flexibily installed. The same applies for dimmer share. By changing the intensity on one of the units, it automatically shares the new settings to the other displays. Sample: Data/dimmer share (RS-485) External dimmer unit Speed data (RS-422) ID1 ID2 ID3 ID4 Group 1 Group 2 In this sample, the display with ID4 receives data (RS-422) from signal distributor and outputs vessel speed data (RS-485) to all connected display. Dimmer share has been separated in two groups, whereas group 1 can be operated by external dimmer and group 2 is linked pressing the button on the display.

Flexibility Signal distributor This speed log incorporates a highly reliable interfacing field. You can easily connect a wide range of additional equipment to optimize your configuration. A second display, smaller remote displays and analogue indicators are just a few of the possibilities. The JLN-205Mk2 can also output the measurement information to radar and ecdis. Signal processor The transducer room has a quite bad environment with regard to vibration and humidity, therefore, before signal is distributed to various equipment, the transducer is directly connected to the processor, minimizing loss of signal and extending cable length to hundreds of meters. No flush mount kit With JRC's new design approach, a flush mount kit is not required and screws are nicely concealed behind the front cover. In the box Display + Bracket Signal distributor Signal processor Transducer + cable (30 m) Data/Power cable (2 m) Spare parts Plates + Manual Options Gatevalve transducer Slave display Analog display Distance counter Data/Power cable Data cable (3 m) T-shape connector Dimmer unit Junction box NKF-531E (with 25 m cable) NWZ-4610 NWW-24/25/26 (flush/wall/table mount) NWW-7 (Up to 9999.99NM) CFQ-5766A/D/F (2/10/20 m) CFQ-5769 (RS-485 network) AA-040404-MMM-TL (RS-485 network) NCM-227 (for NWZ-4610) CQD-10 (extending signal distributor)

Weight and dimensions Display unit NWZ-4610 Weight 600 g (+ bracket 130 g) Cutout dimensions 142 mm 162 mm 127 mm 142 mm 175 mm 55 mm 92 mm 127 mm Signal distributor Signal processor NQA-4288A Weight 6 kg NJC-25 Weight 10 kg 420 mm 310 mm 300 mm 130 mm 280 mm 123 mm Transducer Gatevalve transducer option NKF-547 Weight 17 kg NKF-531E Weight 48 kg 390 mm 130 mm 160 mm 135 mm 468 mm

Specifications JLN-205Mk2 IMO compliant Operating method Dual beam pulse Doppler system Frequency 2MHz Speed range -10kn to 40kn Distance run (range) 0 to 99999.99NM (NWW-7 is 9999.99NM) Depth range Relative speed to water of depth greater than 3 meter below hull bottom Speed accuracy ±1% or ±0.1kn whichever value is greater Distance accuracy ±1% or ±0.1kn in each hour whichever value is greater Speed unit kn or m/s Display unit 4.5-inch monochrome LCD (128 by 64 dots) Backlight White and orange LED selectable Dimmer levels Bright, medium, dark, off Dimmer control Keys or external control Contrast 13 levels Keys 12 (backlit) keys Alarm indication Sound and/or LCD backlight color change IEC-61162-1 input RMC, RMA or VTG (for displaying SOG from GPS) IEC-61162-1 output 8 ports (NMEA0183 ver 1.5 or 2.3: VBW, VLW sentence) Other output Ship's speed: 2 ports (DC voltage signal for analog display -2V to 10V DC) Log pulse: 4 ports (Opto-coupler signal 200 pulses/nm, 30V, 50mA max) Log signal: 1 port (Relay closure signal 200 pulses/nm, 30V, 1A max) Slave display signal: 2 ports Distance signal: 1 port Remote display signal: 1 port RMS: 1 port Power fail alarm: 1 port (Relay closure signal 250V, 5A max) Power supply voltage 100-115V/220-230V AC ±10%, 50/60Hz Power consumption Less than 100VA Ambient conditions Temperature: -15 to 55 C (operating) Relative humidity: 0% to 93% non-condensing JRC offices around the world Amsterdam Athens Hamburg Hanoi Hong Kong Jakarta contents are subject to change without notice Manilla New York Rio de Janeiro Authorized reseller Seattle Shanghai Singapore Taipei Tokyo jrc.co.jp JRC -13.06/66/1