Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Similar documents
Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

A low-cost, economical solution for distribution feeder protection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

High-speed transformer differential protection for up to five terminals

Advanced distribution feeder solution with integrated protection, monitoring, and control

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

2 ms arc-flash protection and feeder relay in one platform

Lightweight and flexible recloser control for single-phase applications

2 ms arc-flash protection and feeder relay in one platform

SEL Time-Domain Link (TiDL ) Technology

SEL Protection, Automation, and Bay Control System

Protect induction and synchronous motors with one relay.

Maximize process uptime with the SEL-patented motor thermal model.

SEL-487B Bus Differential Relay

Powerful and flexible recloser control for many popular reclosers

Comprehensive protection for large, medium, and small generators

Protect induction and synchronous motors with one relay

One relay for safety and process continuity

Built for speed, security, and simplicity

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

SEL-400 Series TiDL Quick-Start Guide

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

SEL-421 Data Sheet. Protection, Automation, and Control System With Sampled Values. Major Features and Benefits

SEL-421-4, -5 Protection and Automation System

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Line differential protection RED670 Relion 670 series

SEL-401 Data Sheet. Protection, Automation, and Control Merging Unit. Major Features and Benefits

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform

SEL-311C-1 Transmission Protection System

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

SEL-351A Protection System Data Sheet

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

Bus Bar Protection Relay B-PRO 4000

NERC PRC-002 Recording Solutions

SEL-651RA Recloser Control

Operator Controls and Reclosing Eliminate expensive control switches and wiring. Selectively reclose with synchronism and voltage checks.

GE Multilin 350 Feeder Protection Relay Specifications

SEL-351S Protection System Data Sheet

SEL-351-5, -6, -7 Protection System Data Sheet

SEL Real-Time Automation Controller (RTAC)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

SEL University. Power Through Knowledge. Dr. Héctor J. Altuve Ferrer Dean of SEL University

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

SEL-387E Current Differential and Voltage Protection Relay

Transformer Protection Relay

SEL-651R-2 Recloser Control

Products Portfolio. Pole mounted Vacuum Recloser

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

750/760 Feeder Management Relay Instruction Manual

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

TWO-WINDING TRANSFORMER DIFFERENTIAL

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Electrical Integration with Smart Communication

High-Speed Railroad Operations

MiCOM P521. Fast feeder differential protection

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

SEL-2030 Communications Processor

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

SEL-751 Feeder Protection Relay

VisoVac padmount fault interrupter

Siprotec 7ST61 / 7ST63

2 NOVATECH. This page is intentionally left blank.

Perfect protection smallest space

The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

SACE Emax 2 Specification guide

SEL-551/SEL-551C Overcurrent and Reclosing Relay

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Feeder/ Motor Protection Relay VAMP 40

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

MiCOM P521. Fast Feeder Differential Protection

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

PROTECTION, AUTOMATION & CONTROL

Transcription:

SEL-451 Protection, Automation, and Bay Control System Advanced feeder protection and complete substation bay control in one economical system Customize distribution protection using multiple instantaneous, time-overcurrent, and directional elements. Detect high-impedance faults with Arc Sense technology (AST). Implement bay control with complete two-breaker control and high-speed breaker failure detection. Time-Domain Link (TiDL ) technology allows you to implement a digital secondary system in the simplest way possible.

Functional Overview Line Bus 3 1 25 27 50 50BF 51 59 67 79 81 O U 85 RIO SEL-451 52PB ANSI Numbers/Acronyms and Functions 25 Synchronism Check 27 Undervoltage 50 RMS Overcurrent 50BF Dual Breaker Failure Overcurrent 51 Time-Overcurrent 52PB Trip/Close Pushbuttons* 59 Overvoltage 67 Directional Overcurrent 79 Autoreclosing 81 (O,U) Over-/Underfrequency 3 Bus 3 BRM DFR HIZ HBL HMI LGC LOC MET PMU SER SBM 1 1 IRIG-B 4 EIA-232 16 S EC 2 Ethernet* 1 Additional Functions 16 SEC Access Security (Serial, Ethernet) 50G Best Choice Ground 85 RIO SEL Mirrored Bits Communications BRM Breaker Wear Monitor DFR Event Reports HBL Harmonic Blocking HIZ High-Impedance Fault Detection AST* HMI Operator Interface LDE Load Encroachment LGC Expanded SELogic Control Equations LOC Fault Locator MET High-Accuracy Metering PMU Synchrophasors SBM Station Battery Monitor SER Sequential Events Recorder TiDL Time-Domain Link Technology* 1 Copper or fiber-optic *Optional feature

Key Features Comprehensive Feeder Protection Customize distribution protection in the SEL-451 Protection, Automation, and Bay Control System with multiple instantaneous, time-overcurrent, and directional elements combined with SELogic control equations. AST detects high-impedance faults, while low-energy analog (LEA) voltage inputs help protect pad-mounted switchgear. Powerful Bay Control and High-Speed Breaker Protection Comprehensive two-breaker control and breaker failure protection complement the versatility of the SEL-451 programmable logic to meet your bay control needs. Easily control motor-operated switches, capacitor banks, and field I/O from the front panel or remotely. Built-In Real-Time Synchrophasor Measurements Help system operators understand the network status with real-time visual displays of system phase angles and frequency. High-accuracy synchronized phasor measurements provide information and control to match the frequency and phase angle for critical activities, such as switching, startup, and power transfer. Monitoring That Maximizes the Capability of Substation Equipment Fully load equipment by monitoring power, including thermal or rolling interval demand as well as peak demand on positive-, negative-, and zero-sequence current. TiDL Technology Modernize your substation by applying the TiDL-enabled SEL-451 and the SEL-2240 Axion TiDL nodes. In a TiDL system, the Axion TiDL node provides remote I/O, digitizes analog signals, and sends the signals over fiber-optic cables to the relay. This simple and secure digital secondary system solution is easy to implement, with no external time source or network engineering required. Replacing copper wires with fiber-optic cables increases safety, reduces costs associated with using copper wires, improves reliability, and limits the impact of electromagnetic interference.

Product Overview EIA-232 front serial port is quick and convenient for system setup and local access. Easy-to-use keypad aids simple navigation. Interactive bay display with user-configurable apparatus labels allows the operator to view the status of breakers and disconnect switches and to control them.

Front-panel LEDs indicate custom alarms and provide fast and simple information to assist dispatchers and line crews with rapid power restoration. Programmable operator pushbuttons with user-configurable labels allow front-panel customization.

Product Overview Choose from a vertical or horizontal, panel-mount or rack-mount chassis and different size options. Use a maximum of 38 output contacts. 1 Order six current inputs in standard terminal blocks (as shown) or a Connectorized hardware configuration. Choose six voltage inputs in either standard terminal blocks, a Connectorized hardware configuration, or an LEA hardware configuration.

Communications protocols include FTP, Telnet, synchrophasors, DNP3 LAN/WAN, the Parallel Redundancy Protocol (PRP), the IEEE 1588 Precision Time Protocol Version 2 (PTPv2),** and IEC 61850 Edition 2.* Use one front and three rear EIA-232 ports for Mirrored Bits communications, DNP3, SCADA, and engineering access. Use a maximum of 55 input contacts. 1 Choose from power supply options such as 24 48 Vdc; 48 125 Vdc or 110 120 Vac; or 125 250 Vdc or 110 240 Vac. 1 Requires 5U chassis *Optional feature **For PTP implementation, Ports 5A and 5B must be ordered as an option.

Product Overview TiDL Option 4U chassis with mounting options (vertical or horizontal; panel or rack) accommodates your application needs. Commission button usage prompts the relay to communicate with the Axion TiDL nodes. LEDs indicate a valid configuration and successful commissioning. Eight 100 Mbps fiber-optic ports allow the TiDL-enabled relay to connect with eight remote Axion TiDL nodes and to receive remote analog and digital data.

LEDs indicate the connection status to a remote Axion TiDL node on a per-port basis.

Applications Complete Overcurrent Protection Customize distribution protection with multiple instantaneous and time-overcurrent elements combined with SELogic control equations. You can select from four phase, four negative-sequence, and four ground instantaneous overcurrent elements to best fit your application. Best Choice Ground Directional Element logic optimizes directional element performance and eliminates the need for many directional settings. High-Impedance Fault Detection Detect high-impedance faults with AST. High-impedance faults are a common result of a downed conductor on surfaces with poor conductivity. With AST, alarm or trip for faults that produce low fault current and are undetectable with conventional overcurrent relays. Two-Breaker Bay Control Meet your bay control needs with complete two-breaker control and high-speed breaker failure detection. You can easily control motor-operated switches, capacitor banks, and field I/O from the front panel or remotely. Configurable labels make it easy to customize the relay controls to match your application. Different bus configurations are available, including single- and dual-busbar, transfer bus, tie-breaker, breaker-and-a-half, ring-bus (shown in the figure below), double-bus/double-breaker, and sourcetransfer configurations. These bus arrangements allow easy status monitoring and control of as many as 20 disconnect switches and two breakers. BAYNAME SW1 BAYLAB1 BK1 BAYLAB2 BK2 SW2 SW3 6 ANALOGS I:99999.9 A V:9999.9 KV P:9999.9 MW Q:9999.9 MV F:99.9 HZ NAVIG ESC

Substation Modernization With TiDL Technology Substation Yard In a TiDL solution, Axion TiDL nodes are placed in the yard close to the primary equipment to digitize discrete I/O signals and analog data and then transport them over a fiber-optic cable to the TiDLenabled SEL-451 in the control house. This innovative technology uses point-to-point connections and a nonroutable protocol, providing a simple and secure solution. Because it does not need an external time source or Ethernet switches, it is easy to implement with no network engineering required. TiDL combines the proven protection of the SEL-400 series relays with the modularity of the Axion, reducing training requirements and providing a scalable and flexible solution. It also provides built-in time synchronization and synchronous sampling, ensuring protection is available in the relay regardless of whether or not an external time signal is available. VAY, VBY, VCY VAY, VBY, VCY SEL-2240 Axion SEL-2240 Axion IAW, IBW, ICW SEL-2240 Axion Feeder 1 SEL-451 Control House IAW, IBW, ICW SEL-2240 Axion Feeder 2 SEL-451 SEL-2240 Axion VAZ (sync. check) Fiber-Optic Cable Pad-Mounted Switchgear Protection Protect pad-mounted switchgear using the SEL-451 with LEA voltage inputs. This helps reduce overall system costs by eliminating amplification electronics between the line sensor and the relay. Having fewer devices leads to a simpler system, a reduction in labor costs, and the elimination of a possible point of failure. V pri Electric Voltage Divider C 1 C 2 Cable C c V sec VY or VZ Terminal Voltage Input (8 Vac LEA input) SEL-451

Harmonic Monitoring Apply the second-, fourth-, and fifth-harmonic elements with individual threshold settings to detect transformer energization and overexcitation conditions. You can use the output from these harmonic detection elements for a variety of functions. For example, modifying the relay settings can improve security, and event reporting makes the identification of transformer energization events fast and simple. Harmonics % of Fundamental 120 110 100 90 80 70 60 50 40 30 20 10 Harmonic Analysis 60 120 180 240 300 360 420 Frequency Custom Automation With SELogic Control Equations Create your own custom applications using powerful SELogic control equations. This allows you to: VAR-Supervised Time-Undervoltage Characteristic Prevent cascading voltage collapse using VAR-supervised time-undervoltage elements. Monitor VAR loading, and trip only the feeders with high VAR demand to prevent voltage collapse. Create an adaptive inverse-time overcurrent characteristic to adjust pickup based on load conditions. Protect ungrounded-wye shunt capacitor banks. Create your own custom curves. Time (s) 15 10 5 Trip Time 0 0.5 1.0 Voltage Per Unit

Panel Integration Improve efficiency and simplify installation with more target LEDs and operator pushbuttons. The 4U and 5U chassis have options for an additional eight target LEDs and four operator control pushbuttons. You can also include arc-suppressed trip/close pushbuttons for an enhanced solution. Display the breaker status and control the breaker position, even if the relay is not powered, with auxiliary breaker trip/close control pushbuttons and indicating lamps. The 24 target LEDs indicate the relay state and various trip conditions and are configurable for specific applications. You can modify the 12 operator pushbuttons to replace traditional panel switches and meet operator control needs. + Close (manual/local) Remote Close/ Autoreclose To Close Circuit Breaker Open 43 local - 52b 52 TC Breaker Closed 52a - 43 local Trip (manual/local) + Remote Trip/ Protection Trips Breaker Wear Monitoring Compare the breaker manufacturer s published data to the actual interrupted current and number of operations for two breakers, and create alarms accordingly. By monitoring the mechanical and electrical interruption time per pole, you can compare average and last trip times for maintenance scheduling. Phase Currents Auxiliary Contact Inputs Station Battery Voltages Relay Circuit Breaker Monitor Excess Breaker Contact Wear Excess Mechanical Operating Time Excess Electrical Operating Time Excess Pole Scatter or Pole Discrepancy Excess Breaker Inactivity Time Excess Motor Running Time Excess ka Interrupted Deviations in Station Battery Voltages

Enhanced Event Analysis Software Use the SEL-451 as a multichannel (six voltages, six currents) digital fault recorder. With SEL-5601-2 synchrowave Event Software, you can view COMTRADE files from the SEL-451 and other digital fault recorders. Event resolutions from 1 to 8 khz and event report lengths from 0.25 to 24.00 seconds (1 khz resolution) are possible. You can perform harmonic analysis of any voltage or current and select the prefault, fault, or post-fault portion of the event report to examine. Synchrophasors To significantly improve your system s performance, SEL offers complete synchrophasor solutions, including hardware, communications, viewing and analysis software, data collection, and data archiving. The SEL-451 provides real-time system state measurement with time-synchronized voltages and currents in the IEEE C37.118 standard format. In addition, SEL-5078-2 synchrowave Central Software or third-party software allow you to view and analyze system phase angles, load oscillations, voltage profiles, and other critical system information.

Accessibility and Communications Built-In Web Server Access basic SEL-451 information on a standard Ethernet network with the built-in web server. From there you can view the relay status, Sequential Events Recorder (SER) data, metering information, and settings with easy access within a local network. For increased security, web server access requires a relay password and the information is limited to a read-only view. Mirrored Bits Communications This field-proven technology provides simple and powerful bidirectional digital communications between devices. Mirrored Bits communications can transmit/receive information between upstream relays and downstream recloser controls to enhance coordination and generate faster tripping for downstream faults. SEL-451 SEL-421 52 MIRRORED BITS Communications Digital, Analog, or Virtual Terminal 52 SEL-451 SEL-421 Ethernet-Based Communications An Ethernet card option provides two copper, fiber, or mixed ports for failover redundancy. Simplify the Ethernet network topology and reduce external equipment with dual Ethernet ports that offer a switched mode for looped Ethernet networks. Available Ethernet communications protocols include FTP, Telnet DNP3, LAN/WAN, IEEE 1588 PTPv2, IEC 61850 Edition 2, IEEE C37.118 synchrophasors, and PRP. Engineering Access SEL-451 SEL-421 SEL-2488 GPS Clock SEL-2730M SEL-3530 Ethernet Switch Wide-Area Network SEL-487B SEL-451

SEL-451 Specifications General AC Current Inputs (6 total) AC Voltage Inputs (6 total) LEA Voltage Inputs Serial Ethernet 5 A nominal 1 A nominal 300 V L-N continuous, 600 Vac for 10 seconds 0 8 VL-N continuous, 300 Vac for 10 seconds 1 front-panel and 3 rear-panel EIA-232 serial ports 300 57,600 bps TiDL Ports Fiber-optic ports: 8 Precise-Time Input Synchrophasors Processing Power Supply Operating Temperature Communications protocols include FTP, Telnet, synchrophasors, DNP3 LAN/WAN, PRP, PTPv2, and IEC 61850 Edition 2 (optional). Choose from the following port options: Two 100BASE-FX fiber-optic network ports Two 10/100BASE-T twisted-pair network ports One 10/100BASE-T twisted-pair network port and one 100BASE-FX fiber-optic network port Range: ~2 km Data rate: 100 Mbps Demodulated IRIG-B time input and PTPv2 IEEE C37.118 standard Up to 60 messages per second AC voltage and current inputs: 8,000 samples per second Protection and control processing: 8 times per power system cycle 24 48 Vdc 48 125 Vdc or 110 120 Vac 125 250 Vdc or 110 240 Vac 40 to +85 C ( 40 to +185 F) Note: LCD contrast is impaired for temperatures below 20 C ( 4 F) and above +70 C (+158 F). Making Electric Power Safer, More Reliable, and More Economical Tel: +1.509.332.1890 Email: info@selinc.com Web: www.selinc.com 2018 by Schweitzer Engineering Laboratories, Inc. PF00074 20180220