Instruction Manual HPH-8

Similar documents
Instruction Manual HID-2

MFJ-1164B AC Line RFI Filter

Instruction Manual CTC-1

NOTICE. Operating Instructions 150W Power Pack. How to Calculate Wattage Load for 150W Power Pack EXAMPLE

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

LANDSCAPE TRANSFORMERS

CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

Rack Mount Power Supplies

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

MFJ ENTERPRISES, INC.

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

AEXX-349 SERIES REMOTE DISPLAYS

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Model HM-535 Power Supply Installation and Service Instructions

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Basketball Shot Clock Set LX2180 Manual

TOKISTAR LIGHTING INSTRUCTION MANUAL

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

PS8 - II. Professional Power Sequencer. User s Manual

Overall Dimensions AE2M-1000 MADJ MW(X)CBLKMP 1000-MPBM. For Reference Only

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC

Transceiver Hub with Integral Camera Power

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Under the Table Interconnect Solutions

Please read the Operational Manual before attempting to use this product. Operational Manual

ELECTRO-MECH SCOREBOARD CO.

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

EnerSure Installation Guide

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Andover Continuum. Power Supplies with or without UPS

E1135C PDU and Pod Upgrade Procedure

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

What s in the Box. Table of Contents

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

E-Series Site Preparation Guide

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

Rexroth Controller Installation & Operations Manual

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

SAVE THESE INSTRUCTIONS

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

ELECTRO-MECH SCOREBOARD CO.

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

MEMORANDUM SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Electrical Components and Equipment for General Use Self Inspection Checklist

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

TC-9102 Series Surface Mount Temperature Controllers

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

CL-MF w CDM (Ceramic Discharge Metalhalide) Fresnel

EATON Transformer Module

THE CTB08D LIGHT CONTOLLER

AE21 SERIES DISPLAY CONTROL TERMINAL

Installation Manual. Alpha 4000 RGB Signs. Before you begin

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Installation Job Aid for Ethernet Routing Switch 3600 Series

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

M215 (M215-60) Safety

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

PCM60A 100W MAX P.A. AMPLIFIER.

B&W RearView Camera Installation & Operation

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

A Creative Light & Sound Company

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Dim levels for each system output may be controlled by any of the following methods:

Vision OPLC V TR6/V350-J-TR6

Quick Start Guide TS A

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Model: VA/230W UPS Backup System

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage XF Series

NightStar. Installation, Operation, & Maintenance Instructions M /04/2016

MFJ ENTERPRISES, INC.

ASCO 920 Remote Control (RC) Switches

CAUTION READ CAREFULLY

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

CAUTION READ CAREFULLY

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Installation, Operation

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved

Transcription:

Specifications HPH-8 Trigger cable 120-volt, Nema 1-15 Main Power 50-amps @ 240-volt AC Power receptacles (4) Nema 5-15 or 6-15 Maximum HID wattage 8000 watts (on 240-volt) 4800 watts (on 120-volt) Maximum number of HID ballast Eight (8) ballast Weight / Dimensions 13 lbs / 7.37 x 5 x 10 Life Expectancy > 10 years Instruction Manual HPH-8 High Power HID controller All Sentinel Timers and controllers offer a 3-year warranty. Sentinel products are distributed by: GPS / Global Product Solutions LLC. www.growgps.com

Introduction When trying to control more than one HID (High Intensity Discharge) lighting system, you can either use a bunch of timers OR a device like the HPH-8. The HPH-8 makes it simple to control up to 8000 watts of lighting from a single timer or controller. The HPH-8 has eight UNIVERSAL receptacles that accept either a 120 volt (Nema 5-15P) or 240 volt (Nema 6-15P) male plug from your HID ballasts. The user provides a single 240 volt, 50-amp circuit to the HPH-8. An internal heavy-duty relay switches the lights On and Off. The relay is turned On and Off by connecting the 15 ft trigger cable (a 120 volt power cable) to a timeclock or controller like the MDT-1. When the timeclock or controller turns ON, the trigger cable caries the voltage to the relay inside the HPH-8, the relays activate, and the (8) receptacles are energized turning the lights connected to the unit ON. The HPH 8 is housed in a sealed, aluminum heat sink A quick look at the HPH-8 enclosure and can be mounted Installation of the HPH-8 using the wall mount bracket Using the HPH-8 included. Connection Examples Heat from the relays and internal components is radiated *120-Volt Option outside the enclosure to ensure Troubleshooting & Specs long life and cool operation. The user must provide and connect a 240 volt, 50-amp circuit to the HPH-8 (see below) TABLE OF CONTENTS HPH-8 electrical connections 240 volt Troubleshooting Some of the more common questions and problems are listed here. Problem: The timeclock or controller is turning On the relay and red indicator light but the lights are not turning ON. Check the main power. If the relay is turned ON, and the ballasts are connected, the main power may not be turned ON. Problem: The red indicator and relay do not turn ON. Check the timeclock or controller that the trigger cable is connected to. The trigger cable provides a 120-volt signal to the HPH-8 that turns ON the relay and red indicator. Try plugging the trigger cable into a known 120-volt power source. If it works, then the problem is with the timeclock or controller you are using to turn the HPH-8 ON. Problem: The circuit breaker for the main power keeps shutting OFF. The circuit breaker is protecting the circuit from overloading. It is possible that one or more of the ballasts have failed (shorted out). Try unplugging each ballast one at a time to determine which ballast has a problem. It is also possible that the amperage is too much for the circuit breaker. Verify the circuit breaker is a 50-amp, 2-pole breaker. Problem: The red light and relay are OFF but the lights remain ON. It is possible that something is wrong with the heavy-duty relay. If the trigger cable is unplugged and the HID lights remain ON, contact the factory. Problem: The red light is ON but I do not hear the relay turning ON and the lights do not turn ON. It is possible that something is wrong with one of the heavy-duty relays. If the red light is ON, and the lights do not turn ON, contact the factory. WARNING: Installation must be completed by qualified person(s). Installation must be done in accordance with state and local electrical codes.

A quick look at the HPH-8 (8) Universal power receptacles accept either 120 volt or 240 volt power cords. Sealed cast aluminum heat sink enclosure keeps internal components running cooler. Indicator light confirms heavyduty relays are energized. Connector for userinstalled 240 volt, 50-amp main power. Wall mount bracket provides secure installation. 15 foot trigger cable connects to timeclock NOTE: The HPH-8 is a high-power device. Locate the HPH-8 away from other sensitive electronics. Even though the enclosure is sealed, DO NOT spray the unit with water... especially the receptacles. Provide a dedicated circuit to the HPH-8 with overload protection. (50-amp / 240 volt)

Installing the HPH-8 *120-Volt Option In order to ensure a safe and proper installation of the HPH-48 follow the steps below. 1) Select the location for the device to be used. Keep the unit away from water. Determine where the trigger cable will be connected to the timeclock or controller. (Extension cords can be used to connect the trigger cable to the timeclock if necessary.) 2) Secure the HPH-8 to the bracket using the screws included with the unit. 3) The wall mount bracket can then be mounted to the wall using appropriate screws. 4) Remove the enclosure cover to expose the relay and terminals. 5) With the main power turned OFF, connect the main 240 volt / 50-amp power to the terminals provided inside the enclosure. (See diagram / photo on the next pages.) 6) DO NOT turn ON the main power yet. Connect the 120 volt trigger cable to the timeclock or controller that will be turning the HPH-8 ON & OFF. 7) Energize (over-ride) the timeclock or controller and verify the RED indicator light and the relays are energized. (The relays will close with a loud clunk noise when it is energized) 8) Once the trigger cable is tested, disconnect the trigger cable from the timeclock or controller. Replace the cover on the HPH-8. 9) Now turn ON the main power. The unit is now ready for use. 10) Ensure that the timeclock / controller that will be activating the HPH-8 is set to turn ON & OFF at the correct times. Reconnecting the trigger cable will complete the installation. WARNING: Installation must be completed by qualified person(s). Installation must be done in accordance with state and local electrical codes. Ground User provided wiring 120vac Main power source 120 volt, 50-amp 120-volt, 2-wire Trigger cable 120v relay & light Important: DO NOT connect 120 volt devices to the receptacles on the HPH-8. DO NOT connect more than 8000 watts of lighting to the HPH-8. Only connect (1) ballast per receptacle.

*120-Volt Option The HPH-8 CAN be used to control ballast that are not capable of being operated on 240-volt power however, the number of ballast that can be operated is greatly reduced if they are operated on 120-volt. Here is a list of the number and wattages that can be used on 120-volt power. 250 to 400 watt = (8) ballasts 600 watt = (6) ballasts 1000 watt = (4) ballasts Notice that only (4) 1000 watt ballast can safely be operated at 120-volt. Each 1000 watt ballast consumes 9+ amps each. The user must provide a singlepole, 50-amp circuit breaker and #6 AWG wire when used with 120-volt. Installing the HPH-8 2 sturdy brackets can be used to fasten the unit to a wall. 120vac 3 wires connected to 2nd relay Ground (8) Universal power outlets accept 120 or 240 volt power cables. HID ballasts are connected here. 50-amp / 240 volt main power cable is installed here. Trigger cable is connected to any 120 volt timer.

Installing the HPH-8 HPH-8 electrical connections (240 volt) WARNING: Installation must be completed by qualified person(s). Installation must be done in accordance with state and local electrical codes. User provided wiring Main power source 240 volt, 50-amp 50-amp / 240 power enters HPH-8 through cable connector. Hid ballasts are connected to pre-wired receptacles. Ground 240vac 120-volt, 2-wire Trigger cable User connects Main power bare or green ground wire connected here. User connects (1) 120 volt wire from main power source here 120v relay & light User connects (1) 120 volt wire from main power source here

HPH-8 electrical connections (240 volt) Most of the wiring inside the HPH-8 is already connected, but the main power needs to be connected by the installer. 3 large aluminum terminals are provided inside the HPH-8. The main power (50-amp @ 240 vac) is connected to the terminals by the user. A #6 AWG 3-wire cable is the correct size cable to use for 50- amps. The user must also use a 50-amp 2-pole circuit breaker to protect the wiring and the HPH-8 Using the HPH-8 The following describes the most common use for the HPH-8. Most users who are using multiple HID ballasts will need to make sure their ballast are wired for use on 240-volt power before connecting them to the HPH-8. Unless your ballast have interchangeable power cables, it may be necessary to open the HID ballast enclosure and physically change the power connection inside the ballast. It is usually as simple as disconnecting the wire coming from the ballast transformer marked (120), and connecting the wire marked (240) to the ballast s power cord. NOTE: The HPH-8 can also be used to control ballasts wired for 120 volt. You must exactly follow the instructions on page # 12 of this instruction manual. (See *120-Volt Option) 240vac 3 wires connected to 2nd relay Because the HPH-8 has Universal receptacles that will accept a variety of different power cables, it is VERY important to doublecheck that all of the devices plugged into the HPH-8 are wired correctly for operation on 240-volt power. If a 120-volt device is connected to a 240-volt power source, the device could be permanently damaged or even cause a fire. Be ABSOLUTELY sure your ballast are wired correctly before energizing your HPH-8 for the first time. WARNING: Installation must be completed by qualified person(s). Installation must be done in accordance with state and local electrical codes. Ground Once the HPH-8 is connected to the main power source and the trigger cable is connected to the timeclock or controller that will activate the HPH-8, the lights connected to the HPH-8 will be turned ON & OFF automatically by the controlling device.

Connection examples Up to (8) HID light fixtures OR 120-volt trigger cable connects to MDT-1 controller or timeclock 240-volt HID ballasts 240-volt HID ballasts HPH-8 NOTE: Up to (8) ballasts equaling 8000 watts can be controlled by the HPH-8. Do not exceed the ratings of the unit. 50-amp @ 240-volt main power supply. (3-wire #6 AWG cable)