Similar documents
Questions & Answers

Cisco Actualtests Questions & Answers

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS

Cisco Questions & Answers

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Implementing Cisco Data Center Unified Computing (DCUCI)

Implementing Cisco Data Center Unified Computing (DCUCI)

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Real4Test. Real IT Certification Exam Study materials/braindumps

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ]

LAN Ports and Port Channels

Cisco Troubleshooting Cisco Data Center Unified Computing. Download Full Version :

UCS Uplink Ethernet Connection Configuration Example

Cisco Real Exam Questions - Guaranteed

Traffic Monitoring. Traffic Monitoring

Direct Attached Storage

Overview. About the Cisco UCS S3260 System

CCIE Data Center Written Exam ( ) version 1.0

Cisco Exam Questions & Answers

Upgrading Earlier Release Version Servers for Cisco UCS Manager Integration

Overview. Cisco UCS Manager User Documentation

Equipment Policies. Chassis/FEX Discovery Policy

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee

Overview. About the Cisco UCS S3260 System

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches?

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Fibre Channel Zoning

Cisco UCS Manager Network Management Guide, Release 3.2

You can monitor or use SPAN on port channels only for ingress traffic.

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS Engineering Details for the SAN Administrator

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

Overview of Cisco Unified Computing System


Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

UCS Fabric Fundamentals

Overview. Overview. This chapter includes the following sections:

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

Exam Questions

UCS C-Series Deployment Options, Best Practice and UCSM Integration

Managing Cisco UCS C3260 Dense Storage Rack Server

Configuring Cisco UCS Server Pools and Policies

Configuring Fibre Channel Interfaces

DCNX5K: Configuring Cisco Nexus 5000 Switches

UCS Management Deep Dive

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee

UCS Fabric Fundamentals

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

FCoE Cookbook for HP Virtual Connect

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Configuring Cisco UCS Server Pools and Policies

Cisco CCIE Data Center Written (Beta) Download Full Version :

Nexus DC Tec. Tomas Novak. BDM Sponsor. Sponsor. Sponsor Logo. Sponsor. Logo. Logo. Logo

Configuring Enhanced Virtual Port Channels

Exam Questions

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions

HRG Assessment. Cisco UCS 5100 and IBM BladeCenter H. Introduction. Summary

Overview. Introducing Cisco UCS Central. This chapter includes the following sections: Introducing Cisco UCS Central, page 1

Global VSAN. Creating VSANs. Global VSAN, on page 1 Fibre Channel Zoning, on page 6

Configuring Dual-Wire Management

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch

Introduction to Cisco UCS Central

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

CCIE Data Center Lab Exam Version 1.0

Unify Virtual and Physical Networking with Cisco Virtual Interface Card

UCS Technical Deep Dive: Getting to the Heart of the Matter

Evolution with End-to-End Data Center Virtualization

Finally they removed the Cat65 VSS Picture to explain FEX

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

Cisco Prime Data Center Network Manager 6.2

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

Cisco UCS Accelerated Accreditation Training

Cisco Nexus B22 Blade Fabric Extender for IBM

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

Cisco UCS Virtual Interface Card 1225

UCS Networking Deep Dive

UCS Management Deep Dive

Configuring Service Profiles

"Charting the Course... Designing Cisco Data Center Infrastructure (DCID) Course Summary

AVANTUS TRAINING PTE LTD

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

"Charting the Course... Implementing Cisco Data Center Infrastructure (DCII) Course Summary

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum

UCS Networking 201 Deep Dive

UCS - the computing vision that boosts your business

UCS Direct Attached Storage and FC Zoning Configuration Example

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

Oracle Database Consolidation on FlashStack

Cisco UCS Manager Storage Management Guide, Release 3.1

IT Agility Delivered: Cisco Unified Computing System

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Introduction to Cisco UCS Central

Implementing Cisco Data Center Infrastructure v6.0 (DCII)

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Transcription:

www.passforsure.co 642-999 www.passforsure.co

QUESTION: 1 When upgrading a standalone Cisco UCS C-Series server, which method is correct? A. direct upgrade on all components B. Cisco Hardware Upgrade Utility C. Cisco Host Upgrade Utility D. Cisco Server Upgrade Utility Answer: C QUESTION: 2 In a standalone Cisco UCS C-Series server, which recommendations can be used to upgrade the BIOS? A. Cisco IMC B. Cisco UCS Manager C. iflash32 Utility D. Flash ROM Utility E. EFI Interface F. Cisco Host Upgrade Utility G. USB Flash Utility Answer: F QUESTION: 3 What are the default settings of the Cisco IMCCIMC NIC properties on a standalone Cisco UCS C- Series server? A: 'Shared LOM' NIC mode with 'Active-active' NIC redundancy and DHCP Enabled

B. 'Shared LOM' NIC mode with 'Active-standby' NIC redundancy and DHCP enabled C. 'Dedicated' NIC mode with 'Active-standby' NIC redundancy DHCP disabled D. 'Dedicated' NIC mode with 'None' NIC redundancy and DHCP enabled E. 'Cisco Card' NIC mode with 'Active-active' NIC redundancy and DHCP enabled Answer: D QUESTION: 4 Which ports can access the Cisco IMC if you select Shared LOM NIC mode in the Cisco IMC Configuration Utility for a Cisco UCS C-Series server? A. the ports on an installed Cisco network adapter card B. the two 1-Gb Ethernet ports C. the two 10/100 management ports D. the two 10/100 management ports, but each port has a default setting Answer: B QUESTION: 5 Which NIC redundancy modes allow the LOMs to be discovered by the operating system or hypervisor? A. Dedicated mode B. Active/Active C. Active/Standby D. Cisco Card Mode Answer: A QUESTION: 6 Which two are true with respect to the unified ports on the Cisco Unified Computing System 62XX Fabric Interconnect? (Choose two.)

A. The port mode is automatically discovered after plugging in a LAN or Fibre Channel-attached cable. B. By default, unified ports that are changed to Ethernet port mode are set to uplink Ethernet port type. C. Ethernet ports must be grouped together in a block and must start with the first port and end with an odd numbered port. D. Alternating Ethernet and Fibre Channel ports is supported on the expansion module. E. After making port mode changes on an expansion module, the module will reboot. F. In a standalone configuration, making port mode changes to the fixed module will not cause the fabric interconnect to reboot. Answer: C, E QUESTION: 7 Which two are true with respect to the switching modes on the Cisco Unified Computing System 62XX Fabric Interconnect? (Choose two.) A. End-host mode presents a link to a northbound uplink switch as a host trunk with loop detection that is provided by STP. B. For northbound traffic, server MAC addresses are statically pinned to an uplink; the return path is controlled by the unified fabric switches. C. A fabric interconnect port in Ethernet switching mode appears to the uplink switch as a host with many MAC addresses. D. Server-to-server traffic on a common VLAN are locally switched by the fabric interconnect and not the northbound switches. E. A MAC forwarding table is not used to forward traffic to the uplink switch. F. A MAC address forwarding table is maintained for server-to-server communications across VLANs. Answer: D, E QUESTION: 8 What is true statement concerning port personalities on the Cisco Unified Computing System 62XX Fabric Interconnect?

A. Fibre Channel uplink ports must operate in Fibre Channel switching mode. B. The fabric interconnects use native FCoE storage ports to directly attach to the SAN infrastructure. C. By default, all Fibre Channel ports are unconfigured. D. The Fibre Channel uplink ports do not support VSAN trunking and Fibre Channel port channels. E. The Fibre Channel storage ports support VSAN trunking and Fibre Channel port channels. Answer: C QUESTION: 9 What is a true statement concerning automatic Fibre Channel pinning on a Cisco Unified Computing System 62XX Fabric Interconnect? A. By default, uplink Fibre Channel interfaces are configured for VSAN trunking. B. Using NPV, each downstream server will be pinned to an uplink port that is based on a PIN group. C. The Fibre Channel pinning process is implemented differently than end-host MAC address pinning. D. With VSAN trunking, the automatic pinning of server traffic to Fibre Channel uplink ports will be based on the server WWN. Answer: D QUESTION: 10 The Cisco UCS administrator has the chassis discovery policy set to "2-link". The administrator connects a new chassis to the Cisco UCS 6200 Series Fabric Interconnects using four links. Which option about link utilization is true? A. The Cisco UCS will use two links until the chassis is reacknowledged, after which it will use all four links. B. The Cisco UCS will use all four links for discovery. C. The Cisco UCS will use only two links. The other two links are unusable. D. The Cisco UCS will use only two links. However, the administrator can manually

pin traffic to the extra links by using service profiles. Answer: A QUESTION: 11 Which policy is used to update adapter firmware? A. adapter policy B. host firmware policy C. management firmware policy D. network control policy Answer: B QUESTION: 12 Which options are valid port types when configuring fixed 10-Gb LAN interfaces on the Cisco UCS 6200 Series Fabric Interconnects? (Choose three.) A. monitoring port B. server port C. uplink Ethernet port D. FEX port E. Fibre Channel storage port Answer: A, B, C www.passforsure.co

www.passforsure.co www.passforsure.co