TECHNICAL BULLETIN. Logix 3200IQ Digital Positioner. Experience In Motion FCD LGENTB /11

Similar documents
3200IQ Digital Positioner

Valtek Logix Series Digital Positioner

TECHNICAL BULLETIN. Logix 500si Series Digital Positioner. Experience In Motion FCD LGENTB /05

TECHNICAL BULLETIN. Logix 500si Series Digital Positioner. Experience In Motion FCD LGENTB /13

USER INSTRUCTIONS. Flowserve ValveAnalysis. Installation and Operation. Experience In Motion. Diagnostic Software Module FCD VLENIM /06

StarPac 3 Intelligent Control System Experience In Motion

CHRONOS IDP INTEllIGENT DIGITAl POSITIONER FOR CONTROl VAlVES

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

SoftTools Suite 7.0. Flowserve Corporation

Type i2p-100 Electro-Pneumatic Transducer

DVC2000 Series FIELDVUE Digital Valve Controllers

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown.

Series 3730 Type Electropneumatic Positioner

Series 3730 Electropneumatic Positioner Type

2-IQ Series Smart Valve Positioners

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

MXa and QXM LB (Linear Base)

VALVE ACCESSORIES & CONTROLS V100 POSITIONER VAC V100 SERIES POSITIONER SIMPLE DURABLE RELIABLE

D3 Digital Positioner. PMV D3 Digital Positioner Product Information. A Flowserve Company

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Fisher i2p-100 Electro-Pneumatic Transducer

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Advanced, Cost-effective, and Reliable HART Communication Products

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Type 330SA High-Performance Electric Actuator

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

PROFIBUS-PA Positioner Type 3785

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

T EN TROVIS Electropneumatic Positioner

Fisher FIELDVUE DVC2000 Digital Valve

Performance!Nxt Release

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

4110 HART Level Encoder

Level-Lance Model 5400A

General Specifications

Fisher FIELDVUE DVC2000 Digital Valve

Series 3730 Type Electropneumatic Positioner

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

IHP24. Intelligent Hydraulic Positioner D HP- PL

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

SideControl Positioner

Series Electropneumatic Positioner Type and Type with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

General Specifications

Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.

Technical Information Promonitor NRF560

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Communicator to a HART device, the tag and model number of the connected device is automatically displayed on the top line of the LCD screen!

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

NELES ND7000 DIGITAL VALVE CONTROLLER

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Explosion-Proof Gauge Pressure Transmitter

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Fisher i2p-100 Electro-Pneumatic Transducer

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

Temperature process values at a glance

Explosion Proof I/P Transducer

Modular Automation System

Electropneumatic Positioner Type and Type with HART communication

Fisher i2p-100 Electro-Pneumatic Transducer

Roxar CorrLog High Accuracy Corrosion Monitoring

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

2900 Float & Tape Transmitter

LTM IntelliGage Series Magnetostrictive Level Transmitters

MC Toolkit (Rugged & Intrinsically Safe models)

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Get to know our positioner! One that masters everything: SIPART PS2. Flexibility for all challenges. siemens.com/positioner

2910 Float & Tape Transmitter

FIELDVUE Instrumentation

HERION SERIES Indirect solenoid actuated spool valves

Smart Wireless THUM Adapter

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57

Smart Wireless THUM Adapter

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX

HART Communicator. Emerson Process Management Catalog

Data Sheet T EN

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Logix 500 Digital Positioner

Digital Positioner 8049

SCADAPack Modbus multivariable transmitter

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Capacitance level switches LS 210 LS 220

Dräger Polytron 8200 Stationary gas detector (CatEx)

Performance!Nxt Release

Actuators & Positioners Intelligent Positioners Field Mount Units / Accessories

Transcription:

TECHNICAL BULLETIN Logix 3200IQ Digital Positioner FCD LGENTB0058-03 01/11 Experience In Motion

Logix 3200IQ Digital Positioner FCD LGENTB0058-03 01/11 Superior Performance and Reliability Introducing the Flowserve Logix 3200IQ Digital Positioner The Flowserve Logix 3200IQ high-performance digital HART positioners utilize state-of-the-art piezo technology to provide superior performance and reliability. This is accomplished through the use of a powerful 32-bit microprocessor and a proprietary twostage electronic relay. Among the Logix 3200IQ s more attractive features are the on-board QUICK-CAL button, DIP switches, Jog buttons, and variable gain selector. These features allow the user to complete setup and calibration of either diaphragm- or piston-operated valves in a couple of minutes, without the need of additional handheld devices or software. The Logix 3200IQ offers valve status updates at a glance using the highly visible LEDs. Users can easily determine if a valve or actuator is functioning properly, and quickly diagnose any problems using the 36 smart LED blink codes. This means that maintenance personnel can provide a visual check of the valve status without having to remove the cover or connect a HART hand-held device or maintenance PC/laptop. Data transfer with SoftTools software is substantially faster than other current HART-compatible systems, resulting in a dramatic speed increase in configuration and diagnostic signature acquisition. The Logix 3200IQ communicates using the latest HART communications protocol, which provides additional capabilities (including burst mode) over previous versions of HART. Inside the Logix 3200MD Figure 1 Logix 3200MD Controls DIP Switches for Fast and Easy Setup No Exposed Electronics 3 All Blink Codes Listed Large QUICK-CAL Button Jog Buttons Gain Selector Switch flowserve.com

Logix 3200IQ Digital Positioner FCD LGENTB0059-03 01/11 Features and Advantages Table 1 Features Easy commissioning Local status LEDs Internal diagnostic codes Fast and simple configuration Jog calibrate Auto Tune HART communication Low air consumption 21-point characterization Two-stage control design High-friction algorithm Configuration lockout NAMUR and VDI/VDE mounting kits Compact and lightweight Advantages Commissioning is performed by simply setting a few switches and pressing the QUICK-CAL button. The Direct User Interface allows local access to positioner control without requiring multi-level menus, a handheld communicator or laptop computer. LEDs, visible from a distance, indicate positioner s current status without removing the cover. LEDs provide instant information relating to internal diagnostic codes. These codes indicate to the user positioner status and alarms without the need for a handheld communicator or laptop computer. With its unique Direct User Interface, the Logix 3200IQ positioner provides fast and easy configuration. Local configuration switches allow the user to set all basic parameters for positioner operation, such as output characteristic (equal percent, linear or custom), air action, signal direction, gain, tuning, etc. The jog calibrate function allows the user to easily and quickly calibrate the positioner on all actuators without physical stroke stops. These buttons also allow the user to exercise local (manual) control of the valve. A simple press of a button starts the self-calibration and auto tune process, speeding up the commissioning procedure and ensuring consistency between one valve and the next (regardless of who performs the procedure). Additionally, a gain selector allows the user to modify the calculated Auto Tune result. Using industry standard HART protocol, the Logix 3200IQ positioner can use existing handheld communicators and supply extensive information to maintenance database software packages. State-of-the-art piezo technology combined with inner-loop feedback produces high-performance control with minimal air consumption. With SoftTools software or a handheld communicator, a custom 21-point characterization curve can be generated that can be used to change the response of the positioner to meet the process requirements. Positioner uses two-stage control to provide faster response and tighter control. Improves control of high-friction ball and globe valves by eliminating overshoot and hunting. Local configuration lockout switch permits users to perform automatic quick-calibration procedures without modifying existing configuration and tuning settings. NAMUR and VDI/VDE mounting interfaces provides direct standardized mounting to various linear or rotary actuators. Brackets are available for non-namur actuators. The positioner s compact design allows it to be installed on smaller actuators. 4-20 ma feedback option Modular design allows reliable position feedback without the need for isolators. 4

Logix 3200IQ Digital Positioner FCD LGENTB0058-03 01/11 Specifications Table 2 Electrical Specifications Power supply Compliance voltage Effective resistance Communications Minimum required start-up current Minimum operating current Table 3 SoftTools Requirements Computer Drive Memory Hard Drive Ports Modem Table 4 Physical Specifications Operating temperature range Housing Weight Two-wire, 4-20 ma input 10 VDC @ 20 ma 500 Ω @ 20 ma HART Protocol 3.6 ma 3.6 ma A computer using a Pentium, higher, or compatible processor and running Windows 95, 98, NT, 2000, or XP CD-ROM drive 32MB RAM minimum (64MB RAM recommended) Approximately 30MB disk space for installation 1 minimum available with 8 maximum possible. (Can also communicate via PCMCIA and USB connections) HART Compatible RS-232 / PCMCIA / USB Modem Standard: -4 F to 176 F (-20 C to 80 C) Low: -40 F to 176 F (-40 C to 80 C) Cast, powder-painted aluminum or stainless steel Aluminum: 8.5 lb. (3.9 kg) Stainless steel: 20.5 lb. (9.3 kg) Table 5 Performance Specifications Response level 0.1% full scale Deadband 0.1% full scale Resolution 0.1% full scale Linearity ±0.5% full scale Repeatability 0.25% full scale Hysteresis 0.5% full scale Air consumption at 60 psig (4 barg) 0.35 SCFM (0.5 Nm 3 /hr) Max./min. air supply Table 6 Hazardous Area Certifications FM/CSA Intrinsically Safe Class I, Div 1, Groups A, B, C, D Class II, Div 1, Groups E, F, G (See Figure 1 for installation requirements.) ATEX (CENELEC) Intrinsically Safe Flameproof Compliant IECEx Flameproof 150 psig/30 psig (10.3 barg/2 barg) Explosion Proof Class I, Div 1, Groups B, C, D Class II, Div 1, Groups E, F, G NEMA/Type 4x II 1G EEx ia IIC T4, T5 T4 Ta = -40 C to 80 C T5 Ta = -40 C to 35 C IP-65 II 2 GD EEx d IIB + H 2 T5, Ta = -40 C to 80 C IP-65 Ex d IIB + H 2 T5 Ta = -20 C to 55 C IP-65 5 flowserve.com

Logix 3200IQ Digital Positioner FCD LGENTB0059-03 01/11 SoftTools Interface Introduction to SoftTools Software NOTE: SoftTools can be downloaded from www.flowserve.com Flowserve s SoftTools Suite software helps manage field devices by combining the features of field network hardware and the HART communications protocol, with the performance of Logix 3200IQ digital positioners. SoftTools Suite is a complete software package, featuring device status, configuration and calibration screens. Additionally, the user can access customized reports for all configuration, calibration and event data. SoftTools software opens the window to the device and allows immediate views with live feedback on all active device sensors including valve stem position, control signal, and other important process metrics. Multiple instances of the software can be run simultaneously, addressing unique positioners. Up to 33 field devices can be viewed simultaneously, allowing the control professional to study cause and effect scenarios. SoftTools software enables communication between the software suite of tools and field device networks using the HART protocol and provides access to the diagnostic information from field devices. Using the MTL or ELCON brand HART multiplexer, users can access more than 63,000 Logix HART positioners from a single workstation. Additionally, the software includes an active database to capture configuration, calibration history and event logging for each digital positioner addressed through the software. Users can now obtain a new level of detailed diagnostic information with SoftTools software. Diagnostic tests and functions (formally available only in strap-on diagnostic testers) are now part of the functionality. The software retains the traditional signature and logging features made popular in previous Flowserve software and adds scheduled polling for device alarms, critical diagnostic tests for friction, and performance analysis of positioners. Configurator Logix 3200IQ configurations can be saved securely in a database file. By uploading a positioner configuration, the information is automatically saved and written to disk on the workstation. SoftTools software allows the user to selectively query the database to isolate or identify specific configurations. The user can sort by any number of parameters including tag number, valve size or type, trim type, flow direction, and liquid or gas application. SoftTools software also allows the user to easily upload a configuration from the positioner. This means that a new replacement positioner can be identically configured with the simple click of a mouse once the correct configuration has been identified. The configurator enables users to edit individual configurations, export to word processors and spreadsheets and import from other files. It also allows the user to format and print a positioner configuration report. 21-point Characterization Curve With SoftTools software, the user can adjust a 21-point characterization curve to change the response of the positioner in order to meet the process requirements. The output of each control point is independent, allowing the user to create a custom curve with very high resolution. This customized curve can be saved in the memory of the Logix 3200IQ, and either activated or overridden with a simple on-board selector switch. Tuning Unlike other positioners that offer only one gain setting, the Logix 3200IQ positioner provides dual-gain tuning. This allows the positioner to make large step changes with minimal overshoot, while achieving the resolution to respond to very small step changes. The Logix 3200IQ positioner not only provides several preset gain settings, it also allows the user to develop custom settings for a wide range of actuator sizes and types. Tuning sets can be configured, or selected with the HART 275/375 handheld, SoftTools, or directly from the user interface on the positioner. By setting the Auto Tune on/off DIP switch, the tuning mode can be changed from manual to auto. The Auto Tune procedure cycles the actuator to produce a measured response and selects those gain values that provide appropriate actuator performance. The Auto Tune function includes a gain modifier selector that can be used to increase or decrease the calculated gain in order to achieve optimal performance. 6

Logix 3200IQ Digital Positioner FCD LGENTB0058-03 01/11 SoftTools, Signatures and Performance Testing Figure 2 Ramp Open Test Signatures The Logix 3200IQ positioner is designed to assure that data is easily gathered, stored and compared to historical valve data so the user can determine the performance of critical valves. With SoftTools software a user-defined signature ramp (Figure 2) or step response test can be generated with a Logix 3200IQ positioner. Signatures can be saved and cataloged (and later retrieved) for comparison (Figure 3) with a more recent signature. Figure 3 Signature Comparison SoftTools software allows a user to easily overlay valve signatures and compare current performance with past performance over a particular time period. This allows the user to determine if degradation has occurred over time on critical valves. It also allows the user to compare historical data and determine if a valve needs to be pulled for maintenance. User-defined steps (large or small) can be tested and stored large steps for speed and small steps for resolution and precision. Internal sensors allow the user to test the response and health of the valve at any time. Positioner Performance Static performance and accuracy measures such as hysteresis, deadband, linearity, and repeatability can be obtained with the Logix 3200IQ positioner. These values can be graphically depicted, stored and later retrieved for comparative analysis (Figure 4). Third Party Configuration Devices Figure 4 Performance Test While no handheld device or software is required to commission and calibrate the Logix IQ, a Fisher-Rosemount HART 275/375 can also be used to perform configurations and calibration. The Logix IQ is AMS Aware, and has complete configuration, alarm and calibration functionality with this software platform. Unique in the AMS Suite of HART instrumentation is the ease of calibration of the Logix IQ. Since the Logix IQ self-calibrates, there is no need for a calibration wizard or a script to guide the user through this operation. AMS simply initiates the QUICK-CAL on the Logix IQ, then awaits confirmation from the Logix IQ that calibration is complete. Most positioners on the market today require a script or wizard that resides on a handheld device or PC-based software to perform a calibration because their on-board microprocessors require it. 7 flowserve.com

Logix 3200IQ Digital Positioner FCD LGENTB0059-03 01/11 Dimensions NOTE: Dimensions in inches (mm) Supply, Output 1 and Output 2 ports ¼-18 NPT thread 5.92 (150.24) 10.63 (269.92) 4.05 (102.74) 3.38 (85.83) 1.24 (31.59) 0.86 (21.76) 7.18 (182.45) 0.97 (24.69) 4.00 (101.60) Customer conduit ports ½-14 NPT thread (M20 optional) Spool Valve Cover and Vent LED Indicators Main Cover Follower arm limit is ±45 from position shown, maximum 0.25 (6.35) 2.00 (50.80) Customer Interface Cover Driver Cover 2.70 (68.68) 0.15 (3.81) 1.13 (28.58) 2.25 (57.15) Square 5.24 (133.15) 1.00 (25.40) 0.75 (19.05) 8

Logix 3200IQ Digital Positioner FCD LGENTB0058-03 01/11 How to Order Selection Code 3 Protocol HART 2 Diagnostics Standard 0 Advanced 1 Aluminum, White Paint (Valtek) 0 Stainless Steel, No Paint (Valtek) 1 Material Aluminum, Black Paint (Automax) 2 Aluminum, Food-Grade White Paint (Automax) 3 Aluminum, Black Paint (Accord) 4 Aluminum, Food-Grade White Paint (Accord) 5 Example 3 2 1 0 Design Version IQ IQ Explosionproof EEx d IIB + H 2, ATEX II 2 G (CENELEC) 07 Explosionproof Class I, Div 1, Groups B, C, D Intrinsically Safe Class I, Div 1, Groups A through G (FM, CSA) FM Nonincendive. CSA Class I, Div 2, Class I, Zone 1, Group IIB + H 2 and Exia Class 1, Zone 0, 10 Certifications Group IIC (CSA Only) General Purpose 14 Intrinsically Safe EEx ia IIC T4, Standard Temp: -40 F (-40 C) Ta 176 F (80 C)/131 F (55 C), ATEX II 1 G (CENELEC) 15 IECEx Ex d IIB + H 2 16 Shaft DD 316 Stainless Steel Shaft (Valtek Standard) D6 NAMUR 316 Stainless Steel (VDI/VDE 3845) N6 Conduit 1/2" NPT E Connections M20 M Four-way (Double-Acting) 04 Action Three-way (Single-Acting) 03 Four-way Vented (Double-Acting) 4V Three-way Vented (Single-Acting) 3V Temperature Operating Temperature (-40 F to 176 F; -40 C to 80 C) 40 Gauges (Valtek standard) OG Stainless Steel Gauges OS Gauges Stainless Steel with Brass Internals (kg/cm 2 ) KG Stainless Steel with Stainless Steel Internals (kg/cm 2 ) KS No Gauges OU Special Options 4-20 ma Position Feedback OF No Specials OO 10 D6 E 04 40 OG OF 9 flowserve.com

United States Flowserve Corporation Flow Control 1350 N. Mt. Springs Parkway Springville, UT 84663 Phone: 801-489-8611 Fax: 801-489-3719 FCD LGENTB0058-03 Printed in USA. To find your local Flowserve representative: For more information about Flowserve Corporation, visit www.flowserve.com or call USA 1 800 225 6989 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2005 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation. flowserve.com