Submersion/Insertion ph/orp Sensors

Similar documents
General Purpose ph/orp Sensor

TUpH ph Sensors. Specifications. Storage. Sensor Installation. Electrode Preparation. 397 Performance and Physical Specifications

Combination ph/orp Sensor

OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES

Introduction: Features:

ph/orp 3/4-inch Combination ph and ORP Sensor Kits Features and Benefits DATA SHEET Versatile Mounting Styles Low Price High Performance

24-hour Continuous Field Monitors

Signet Conductivity Electrodes

SIGNET ph/orp Transmitter

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

Instruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter

INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor

ph600 2-wire ph/orp Transmitter

OPERATING INSTRUCTION MANUAL

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

INSTRUCTION MANUAL ORP-METER MODEL COR-01

Microprocessor ph/orp Controller

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Smart Conductivity. Reliable and Accurate Conductivity/Resistivity Measurement. THORNTON Leading Pure Water Analytics

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

+GF+ SIGNET ph/orp Transmitter Instructions

Type MS04. Redox potential sensor cube. Operating Instructions

Contents. 1. Installation

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

770MAX Conductivity/Resistivity Sensors THORNTON. Leading Pure Water Analytics

Signet 2750 DryLoc ph/orp Sensor Electronics

User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

Operations Manual EcoSense ph100a

Signet ph/orp Transmitter

Portable Conductivity Meter M1410. User Manual 1.002

OPERATION MANUAL MODEL TT-LP

MULTI meter MU 6100 H

Hanna Instruments HI9819X Multiparameter series

DO Meter Kit. Instruction Manual

KOBOLD PDA Series Digital Pressure Transmitter

Agilent 3200M Multi-Parameter Analyzer

GeneMate Benchtop ph Meters Operation Manual

portable waterproof multiparameter meter

TruLab ph/ise 1320(P)

WK7200. Water Quality Test Kit USER S MANUAL

Tracer ph/tds/salt PockeTester TM Code 1766

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Digital O.R.P. Transmitter Type 8206

HI 9828 Multiparameter Water Quality Meter...

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

HI 9828 Multiparameter Water Quality Meter...

Plug & Play Analytical Solutions Making Basic Measurements Easy

Resolution selectable from 0.01 and ph. Range to ph. Accuracy ± ph

PH450 Analyzer Proper Calibration Steps

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company

GENERAL SAFETY GUIDELINES

Handheld Water Quality Meters 100 Series

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

IOTRON TM SERIES SENSORS INTEGRATED INDUSTRIAL ph SENSOR SPECIFICATIONS

MODEL 245 / 345 High Range

AquaController Apex Probe Module 1

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

KOBOLD TDA Series Digital Temperature Transmitter

The manual is divided into the following sections:

MODEL 245 / 345 DigiComp

Electrodes ph EC DO /14 dge 2 P/L e

Operations Manual EcoSense ph100

SIGNET 5700 ph/orp Monitor - ORP Instructions

Model T28 Transmitter

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

ph/orp Meter SD Card real-time Datalogger

KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY

Calibration of ph requires flow shutdown to the sampling piping and removal of the ph sensor and the following sequence:

Instruction Manual PN pH/rev.C April Model 2081 ph. Smart Microprocessor Analyzer

Instruction Manual HI 2212 HI 2213 ph/mv/ C Bench Meters with Custom Buffers

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Instruction Manual. Portable ph Meter ph -20N (ph/mv/orp/temp) ph -25N (ph/ise/mv/orp/temp) Website :

Model 901-PH ph-mv-temp. Meter Handbook Version : 2.1 : 25-Mar-99

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet

STARTER 3000 Bench ph Meter Instruction Manual

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Datalogging ph Meter

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet

Bante902 Benchtop ph/conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Aqua TROLL 600 Multiparameter Sonde

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

Description, continued

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

Handheld Water Quality Meters 100 Series

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

Transcription:

Instruction Sheet PN 51A-396VP/rev.G January 2011 Models 396VP and 398VP Submersion/Insertion ph/orp Sensors For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS: SPECIFICATIONS MODEL 396VP MODEL 398VP Measurements and Ranges* ph: 0-14 ph: 0-14; ORP: -1500 to 1500 mv Available ph ACCUGLASSTypes GPHT hemi bulb or GPLR flat bulb GPHT hemi bulb or GPLR flat bulb Wetted Materials 316 SST, Polypropylene, EPDM, glass Titanium, Tefzel 1, glass, choice of Kalrez 1, Viton 1, or EPDM (platinum: ORP only) Process Connection None, use 1 in. NPT process connector, None, use 1 in. NPT process connector PN 23166-00 or 23166-01 (sold separately) PN 23166-00 or 23166-01 (sold separately) Temperature Range 0-85 C if SMART (-70) is used, 0-100 C (32-212 F) 0-100 C (32-212 F) Pressure Range - Hemi bulb 100-1136 kpa (abs) (0-150 psig) 100-1825 kpa (abs) (0-250 psig) Pressure Range - Flat bulb 100-790 kpa (abs) (0-100 psig) 100-790 kpa (abs) (0-100 psig) Minimum Conductivity 100 µs/cm, nominal 100 µs/cm, nominal Preamplifier Options integral SMART (-70) No Solution Ground No No VP8 Cable PN 24284-00 (more options available) PN 24281-00 (more options available) 1 Tefzel, Viton and Kalrez are registered trademarks of DuPont Performance Elastomers. CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Application compat ibility is entirely the responsibility of the user. CAUTION The buffer in the protective boot may cause skin or eye irritation. ATEX DIRECTIVE Special Conditions for safe use 1. All ph/orp sensors have a plastic enclosure which must only be cleaned with a damp cloth to avoid the danger due to a build up of an electrostatic charge. 2. All ph/orp sensor Models are intended to be in contact with the process fluid and may not meet the 500V r.m.s. a.c. test to earth. This must be taken into consideration at installation. *PERCENT LINEARITY ph range Hemi bulb GPHT Flat bulb GPLR 0-2 94% 93% 2-12 99% 98% 12-13 97% 95% 13-14 92% WARNING Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level! DANGER DO NOT connect sensor to power lines. Serious injury may result. WARNING Glass electrode must be wetted at all times (in storage and in line) to maximize sensor life.

INSTALLATION For sensor dimensions, see Figure 1. For sensor orientation, see Figures 2 and 3. For wiring, see Figures 4-22. ELECTRODE PREPARATION 1. Remove electrode from shipping container. 2. Remove the protective boot covering the electrode bulb. 3. For ph electrode, rinse away salt film with clean water, then shake the electrode so that the internal solution fills the bulb, thus removing any air trapped there. TWO POINT BUFFER CALIBRATION Select two stable buffer solutions, preferably ph 4.0 and 10.0 (ph buffers other than ph 4.0 and ph 10.0 can be used as long as the ph values are at least two ph units apart). NOTE A ph 7 buffer solution reads a mv value of approx. zero, and ph buffers read approximately ± 59.1 mv for each ph unit above or below ph 7. Check the ph buffer manufacturer specifications for millivolt values at various temperatures since it may affect the actual value of the buffer solution mv/ph value. 1. Immerse sensor in the first buffer solution. Allow sensor to equilibrate to the buffer temperature (to avoid errors due to temperature differences between the buffer solution and sensor temperature) and wait for reading to stabilize. Value of buffer can now be acknowledged by analyzer/transmitter. 2. Once the first buffer has been acknowledged by the analyzer/transmitter, rinse the buffer solution off of the sensor with distilled or deionized water. 3. Repeat steps 1 & 2 using the second buffer solution. 4. The theoretical slope value, according to the Nernst equation for calculating ph, is approximately 59.17 mv/ph. Over time the sensor will age, both in the process and in storage, and will result in reduced slope values. To ensure accurate readings, it is recommended that the electrode be replaced when the slope value falls below 47 to 49 mv/ph. RECOMMENDED ph SENSOR STANDARDIZATION For maximum accuracy, the sensor can be standardized on-line or with a process grab sample after a buffer calibration has been performed and the sensor has been conditioned to the process. Standardization accounts for the sensor junction potential and other interferences. Standardization will not change the sensor s slope but will simply adjust the analyzer s reading to match that of the known process ph. MAINTENANCE FOR ph ELECTRODE Electrodes should respond rapidly. Sluggishness, offsets, and erratic readings are indicators that the electrodes may need cleaning or replacement. 1. To remove oil deposit, clean the electrode with a mild non-abrasive detergent. 2. To remove scale deposits, soak electrodes for 30 to 60 minutes in a 5% hydrochloric acid solution. 3. Temperature effect on life expectancy: If glass electrode life expectancy is 100% @ 25 C (77 F), then it will be approximately 25% @ 80 C (176 F). ORP CALIBRATION 1. After making an electrical connection between the sensor and the instrument, obtain a standard solution of saturated quinhydrone. This can also be made quite simply by adding a few crystals of quinhydrone to either ph 4 or ph 7 buffer. Quinhydrone is only slightly soluble, therefore only a few crystals will be required. 2. Immerse the sensor in the standard solution. Allow 1-2 minutes for the ORP sensor to stabilize. 3. Adjust the standardize control of the instrument to the solution value shown in the table below. The resulting potentials, measured with a clean platinum electrode and saturated KCl/AgCl reference electrode, should be within +/- 20 millivolts of the value shown in the table below. Solution temperature must be noted to ensure accurate interpretation of results. The ORP value of saturated quinhydrone solution is not stable over long periods of time. Therefore, these standards should be made up fresh each time they are used. 4. Remove the sensor from the buffer, rinse, and install in the process. STORAGE 1. It is recommended that electrodes be stored in their original shipping containers until needed. 2. Do not store at temperatures below -5 C (23 F). 3. Electrodes should be stored with a protective cap containing KCl solution (PN 9210342). 4. For overnight storage, immerse the sensor in tap water or 4 ph buffer solution. 5. A ph glass electrode does have a limited shelf life of one year. MAINTENANCE FOR ORP ELECTRODE Electrodes should respond rapidly. Sluggishness, offsets, and erratic readings are indicators that the electrodes may need cleaning or replacement. 1. To remove oil deposit, clean the electrode with a mild non-abrasive detergent. 2. To remove scale deposits, soak electrodes for 30 to 60 minutes in a 5% hydrochloric acid solution. 3. ORP (metallic) electrodes should be polished with moistened baking soda. ORP of Saturated Quinhydrone Solution (millivolts) ph 4 Solution ph 7 Solution Temp C 20 25 30 20 25 30 mv Potential 268 264 260 94 87 80 2

INSTALLATION FIGURE 1. Sensor Dimensions FIGURE 2. Flow Through and Insertion Installation For Models 396VP and 398VP 1-1/2 inch Pipe Tee (PN 2002011) with 1 inch threaded connections. NOTE: The sensor must be mounted at least 10 above the horizon. 3

MILLIMETER INCH INCH MILLIMETER FIGURE 3. Typical Submersion Installations for Models 396VP and 398VP 4

WIRING FIGURE 4. VP8 Cable, sensor end FIGURE 5. VP8 Cable, instrument end FIGURE 6. Model 81 Wiring FIGURE 7. Model 1181 Wiring FIGURE 8. Model 81 Wiring through Remote Junction Box FIGURE 9. Model 1181, 1050/1060, & 1003/1023 Wiring through Remote Junction Box 5

FIGURE 10. Model 2081 Wiring FIGURE 11. Model 5081 VP6 Wiring FIGURE 12. Model 2081 Wiring through Remote Junction Box FIGURE 13. Model 3081, 4081, & 5081 Wiring through Remote Junction Box FIGURE 14. Model 54e VP6 Wiring FIGURE 15. Model 54e Wiring through Remote Junction Box 6

FIGURE 16. Model 1055-22-32 Wiring FIGURE 17. Model 1055-22-32 Wiring through Remote Junction Boxes FIGURE 18. Model 1055-10-22-32 Wiring 7

FIGURE 19. Model 1056 VP6 Wiring FIGURE 20. Model 1056 VP8 Wiring Standard VP8 wiring to 1056 FIGURE 21. Model Xmt VP8 Wiring 8

FIGURE 22. Model 54e VP8 Wiring Standard VP8 wiring to 54e FIGURE 23. Model 5081 VP8 Wiring Standard VP8 wiring to 5081 FIGURE 24. Model 1055 VP8 Wiring 9

FIGURE 25. Model 6081 VP6 Wiring FIGURE 26. Model 6081 VP8 Wiring Standard VP8 wiring to wireless 6081 FIGURE 27. Model 1056 Wiring through a j-box 10

FIGURE 28. Model 1055-11-22-32 Wiring Through Remote Junction Boxes FIGURE 29. Model Xmt-P-HT VP6 Wiring FIGURE30. Model 1054A/B & 2054 Wiring FIGURE 31. Model 1054A/B & 2054 Wiring through a Remote Junction Box 11

ACCESSORIES PART NUMBER DESCRIPTION 24281-00 15 ft. VP8 cable 24281-01 25 ft. VP8 cable 24281-02 2.5 ft. VP8 cable 24281-03 50 ft. VP8 cable 24281-04 100 ft. VP8 cable 24281-05 4 ft. VP8 cable 24281-06 10 ft. VP8 cable 24281-07 20 ft. VP8 cable 24281-08 30 ft. VP8 cable 22698-00 Preamplifier plug-in for junction box, for Model 1003 22698-02 Preamplifier plug-in for junction box, for Models 1181, 1050 22698-03 Preamplifier plug-in for junction box, for Models 1054A/B, 2054, 2081 22743-01 Pt100 preamplifier for Model 1181 22744-01 3K Preamplifier for Model 1181 23557-00 Preamplifier for junction box for Models 54, 3081, 81, 4081 33046-00 Ferrule, 1 in., split 316SS 9310096 Nut, swage, 1 in. 316SST 9210012 Buffer solution, 4.01 ph, 16 oz 9210013 Buffer solution, 6.86 ph, 16 oz 9210014 Buffer solution, 9.18 ph, 16oz R508-160Z ORP solution, 460 mv ± 10 at 20 C 9550167 EPDM O-ring for Process Connector (PN 23166-00 or 23166-01) 12707-00 Jet Spray Cleaner NOTE: All accessories above can be used with the Models 396VP, 396RVP, 398VP and 398RVP. 1 Kynar is a registered trademark of Elf Atochem North American, Inc. 2 Teflon is a registered trademark of E.I. du Pont de Nemours and Company. The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2011