GE Power Management. MMII Intelligent MCC Controller

Similar documents
FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

LM10 to MM200 Retrofit

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

STANDARD SUBMITTAL PACKAGE

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

One relay for safety and process continuity

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

MSR-HD Motor Protection Relay. GB Instruction Manual

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

SSW06. Soft Starters.

CURRENT PROTECTION RELAY SMPR-1

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

Optidrive Applications Support Library

FM2. Feeder Manager 2 INSTRUCTION MANUAL. GE Industrial Systems

Maximize process uptime with the SEL-patented motor thermal model.

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Multilin MM200. Low Voltage Motor Protection and Control. Protection and Control. Metering & Monitoring. Communications. EnerVista Software

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

MM300. Integrated automation and protection for low voltage motors. Digital Energy Multilin. Metering & Monitoring. Protection and Control

VLT 2800 DRIVE SPECIFICATIONS

DGC-2000 DIGITAL GENSET CONTROLLER

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

MNS with M10x Intelligent motor management

Vector Drive - Troubleshooting Guide

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Optidrive Applications Support Library

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

POWER METER HC Features

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

M550 & M560 MOTOR PROTECTION RELAY

SMARTSTART MOTOR STARTERS

PowerFlex 40 Sample Specification

Compressor Controller MAM 890

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Q9 ASD LOW VOLTAGE DRIVE

SECTION VARIABLE FREQUENCY DRIVES

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

A drive dedicated to variable speed control for HVAC applications

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

PHASE MONITOR RELAYS Product Summary

PRICE LIST WITH EFFECT FROM 1st September 2016 ISSUE NO. 29

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

IPS INTELLIGENT PUMP STARTER

Easy To Use OEMS Take Note

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

MPS DEVICENET INTERFACE

How to Control and Monitor a C441 Motor Insight via DeviceNet

S.W. Version SubMonitor Connect Installation & Operation Manual

3GV M Modbus RTU Register Map

PFC-10 Power Factor Controller

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Standards Update Notice (SUN) Issued: April 25, 2017

MIC-2 Multi-instrument DATA SHEET

MNS with M10x Intelligent motor management

469 Motor Management Relay

1. Introduction. 2. Installation MODBUS INTERFACE

URC Utility Relay Company

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

Instruction Manual * DC* GE Consumer & Industrial Multilin MOTOR PROTECTION RELAY ISO9001:2000 G E M U LT

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Bulletin 825-P Modular Protection System

Technical Specificaions. kwh Energy Meter

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Technical Specifications. Dual Source kwh Energy Meter

FP-5000 Feeder Protection

EM6400 series Multi-Function meters

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

MAS Monitoring system for pumps. Reliable operation Low LCC Easy handling

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

SACE Emax 2 Specification guide

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Optidrive VTC Modbus RTU Register Map

Smartstart Control Module

Generator Management Relay COMMUNICATIONS GUIDE

ENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET

Trident and Trident X2 Digital Process and Temperature Panel Meter

HVAC Products. Introducing the SED2 Variable Frequency Drives

EDR-3000 Eaton Distribution Relay

Transcription:

A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance.

Presentation Overview 6 Applications 6 Protection and Control 6 Inputs 6 Metering and Monitoring 6 User Interface 6 Communications 6 Typical Wiring 6 Ordering

Applications In one package the Motor Manager II (MMII) combines control functions and comprehensive motor protection, providing sophisticated control and protective relaying. = Low voltage motor control centers = Integrated process and electrical control

Application 480 VOLTS BUS 52 SINGLE LINE DIAGRAM FUSE CONTACTOR CONTACTOR A (FORWARD/WYE) CONTACTOR B (REVERSE/DELTA) AUX 1 RELAY PHASE PT PHASE CT 59 27 51 49 37 46 AUX 2 RELAY GROUND CT WINDING THERMISTOR 51G 49 MOTOR MANAGER II CONTROL INPUTS 4-20mA INPUT PROCESS PLC OR TRANSDUCER Legend THERMISTOR LOAD MOTOR RS485 REMOTE COMMUNICATION 1200-19K2 BAUD

Application DEVICE PROTECTION 49/51 overload 46 phase unbalance (single phase) welded/open contactor 50G/51G ground fault 48 locked rotor/stalled rotor 49 hot winding (thermistor) 37 undercurrent/under power 27 undervoltage 59 overvoltage STANDARD PROTECTION OPTION 2 ENHANCEMENT

Protection = Overload = Phase unbalance = Contactor failure = Locked/stalled rotor = Ground fault = Hot winding thermistor = Undercurrent/underpower

Protection 100000 10000 4 NEMA compatible time/current overload curves TIME IN SECONDS 1000 100 10 CURVE # CLASS 30 CLASS 20 CLASS 15 CLASS 10 1 0.1 0.5 MULTIPLE OF 1 PICKUP 2 3 CURRENT 4 5 6 7 8910 (PER 20 UNIT) 50 100

Control = Undervoltage auto restart = Outputs (assignable to any one of 31 functions) = 2 contactor (A and B) = 2 programmable = Inputs: 6 fixed, 10 programmable = 1 analog input

Inputs = Switched Inputs = up to 6 fixed control inputs used for start A and B, stop, local isolator, and contactor A and B status. = Switched Inputs = scaleable to user defined values = high and low alarm and trip setpoints recorded with time delays

Metering = The MMII meters and displays: = RMS current of each phase = ground fault leakage current = motor load as a % of full load current = thermal capacity used (%) according to I 2 t history and chosen overload curve; hot/cold ratio is used to model heating when running below full motor current = % unbalance = power (kw) = energy (kwh) = voltage = analog input

Monitoring = Trip Record = when a trip command is issued, a trip record is generated, including the cause of trip and pre-trip actual values = Statistics and Maintenance = user enabled to set the interval at which a number of routine maintenance tasks should be performed. When these times are exceeded an alarm is generated, including: = motor greasing interval = contactor inspection = maximum motor stopped time

User Interface = RS485 ModBus, 1200-19,200 bps = Display model for local interface = Up to 11 status LEDs = MMII PC Software

User Interface The Chassis Mount Model = mounted inside the motor control center (MCC) = comes with all standard features = setpoints are loaded through the RS485 communications port from a personal computer running the MMII program.

User Interface MMIIPC Software 6 Windows based software > Windows 95 or Windows NT > Features: = program or modify setpoints = load or save setpoints from or to a disk = read actual values from the MMII = monitor status = read pre-trip data and trip record = display dynamic trending of actual values = get help on any topic = print the instruction manual from disk

Front View DISPLAY: 2 line, 40 character illuminated display communicates all messages in simple English for easy interpretation by users unfamiliar with unit RELAY INDICATORS: RELAY A: Contactor A energized RELAY B: Contactor B energized AUX 1: User programmable relay 1 energized AUX 2: User programmable relay 2 energized PROGRAM KEYS: ACTUAL VALUES: Press to enter actual values mode to display actual motor values such as current, ground leakage, thermal capacity. SETPOINTS: Press to enter setpoint mode to alter or examine setpoints. STORE: Save a newly entered setpoint. RESET: Reset the MMII after a trip. MESSAGE: Move to the desired setpoint or actual value message. VALUE: Increment or decrement currently displayed setpoint value.

Front View CONTROL KEYS: AUTO: Selects operation of start via communication port. MANUAL: Selects manual operation of motor using start key. START A: Energize contactor A. START B: Energize contactor B. STOP: De-energize contactors. STATUS INDICATORS: RUNNING: Contactor is energized and motor is running. STOPPED: Contactor is not energized and motor is not running. TRIPPED: Contactor is not energized. Motor is not running. The MMII has tripped the motor due to a fault. Normally a cause of trip message will be displayed. ALARM: One or more alarm conditions are present. Normally a cause of alarm message will be displayed. FAULT: An internal fault or abnormal condition has been detected. The MMII may need to be replaced or serviced.

Rear View COMMUNICATIONS RS485 2 wire serial communication port operates at 1200-19,200 bps for remote commands, monitoring and setpoint store. ModBus RTU protocol. SWITCH INPUTS Opto-isolated 120 VAC live inputs for various interlock functions. The interlock inputs are fully programmable and can be assigned to such functions as setpoint access, plant interlock, test, and various others. CONTROL POWER CONTROL POWER 120/240 VAC supply voltage selector switch and fuse access door SUPPLY VOLTAGE required to power the MMII 4 RELAYS = Contactor A: direct on line / forward / wye = Contactor B: reverse / delta = User programmable relay (AUX 1) = User Programmable relay (AUX 2)

Rear View Ground safety and surge ANALOG INPUT 4-20mA input for process control monitoring / alarming / tripping. VOLTAGE INPUT Phase A voltage input for voltage and power monitoring. THERMISTOR NTC or PTC thermistor input for hot winding detection. PHASE CT INPUTS 3 isolated phase CT inputs that accept 1 amp or 5 amp CT. GROUND CT INPUT 5 amp or 50:0.025 ground fault input for residually connected phase CTs or separate core balance (zero sequence) CT.

Communication = ModBus RTU RS485 connection Up to 32 MMIIs can be daisy chained together on a single communication channel. = supports operation at 1200 to 19,200 bps

Typical Wiring CT PHASE A Residual Ground Connection Two Phase CT Connection Direct Connection CT CT CT CT PHASE A PHASE B PHASE C PHASE C PART 2 OF DIAGRAM

Isolater Switch Contactor L1 L2 L3 CT Phase A Core Balance (Zero Sequence) CT Phase B CT Phase C CT Ground L1 L2 L3 MOTOR Stop Start A Fixed Switch Inputs Programmable Switch Inputs MOTOR MANAGER II = Option 1: Process control = Option 2: Enhanced protection 4-20mA Analog Input RS485 Stator Thermistor MCC Ground Bus L AC Control Voltage 120 / 240 VAC N Contactor A

Ordering MMII Basic Unit PD Panel Mount With Display * C Chassis Mount (Black Box) 1 Option 1 Process control, process input, undervoltage auto restart, diagnostics 2 Option 2 Enhanced protection, power (kw), thermistor, 2nd contactor control 120 Control voltage 120 VAC 240 Control voltage 240 VAC

Ordering Accessories: MMIIPC software package supplied free RS232 TO RS485 CONVERTER box designed for harsh industrial environments 5A PHASE CT: 50, 75, 100, 150, 200, 250, 300, 350, 400, 500, 600, 750, 1000 1A PHASE CT: 50, 75, 100, 150, 200, 250, 300, 350, 400, 500, 600, 750, 1000 50:0.025 GROUND CT for sensitive ground detection on high resistance grounded systems COLLAR for reduced depth mounting Modifications: MOD601: 240 VAC switch inputs - allows the use of external 240 VAC supply to power switch inputs MOD602: 24-48 VDC switch inputs - allows the use of external 24-48 VDC supply to power switch inputs MOD603: ESD relay - converts AUX 2 relay into an emergency shutdown relay MOD605: Removable rear terminals - allows terminals 13-58 to be unplugged from the MMII MOD610: Conformal coating MOD613: 240 VAC VT input MOD616: MMII with remote display