Common Mode Noise The Often Neglected Tenth Power Problem

Similar documents
Dirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.

AC Power Quality and Protection

Surge Protector. Esma Khatun

Tel: Web: Lightning and surge protection help pages

Liebert Precision Power Center

UPS Operating Modes: A Global Standard. A White Paper from the Experts in Business-Critical Continuity

HANDOUT Electrical Safety How do we make sure that humans and computer equipment are safe from electrical hazards?

Power Quality. and Computers on the Farm

Industrial Facility Wide Protection

Power Quality of Commercial Buildings - Advanced

How Power Problems Affect PLC Reliability

Power supply (Power supply unit or PSU) is a device or system that supplies electrical or other types of energy to an output load or group of loads.

Common Power Problems & Power Protection Solutions

Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

ALP UPS FEATURES & ADVANTAGES

Data Line Transient Protection

Data Line Transient Protection

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

LIGHTNING AND SURGE PROTECTION

Power Quality of Commercial and Industrial Power Systems

Power and Grounding For Audio and Video Systems Part 1

Advanced technology for superior protection

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

Data Sheet. Surge protection devices - A technical overview

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

electrical disturbances how to protect businesses

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

Power and Grounding For Audio and Video Systems Part 1. Jim Brown Andy Benton

The Different Types of UPS Systems

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

PREVENTING DOWNTIME OF E911 CENTERS

Technical Data Sheet Medium Current Power Surge Filters

Power and protection for your rackmount and cabinet equipment.

Grid to Chip Surge Protection Product Catalog

Liebert Nfinity. A Powerful UPS Solution For Small To Medium Data Centers. AC Power For Business-Critical Continuity

Liebert THE NEW SHAPE OF NETWORK POWER PROTECTION. UPStation GXT 2U. An On-Line UPS With Proven Reliability,

SAMPLE. MOVs are sometimes referred

INDUSTRIAL POWER QUALITY PROBLEMS. A. El Mofty K. Youssef. Alexandria Electricity Company, Alexandria Egypt SUMMARY

THE NEW SHAPE OF NETWORK POWER PROTECTION

Quantum Chargers Enhanced AC Line Transient Immunity

After the storm leaves the area, you pat yourself on the back for protecting your data and equipment. The worry is over. Or is it?

Z8 G4 Site Prep Guide Table of contents

Introduction to Proper Variable Frequency Drive Installation Practices. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

I need to protect my equipment against damaging power surges and spikes.

"Powering and Protecting Networks and Equipment Connected to It" Jim Pelegris ITW/LINX

White Paper. AC Surge Protection. Evaluation of Series Element Surge Protective Device for Protection of Electronic Equipment and Systems

RETAIL Price List - Valid From June 2017

Standard SureVolt Power Conditioner / Voltage Regulator

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Surge Protectors and Digital Timer

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

Specifying your exact choice of power supply: alternatives to full customization

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Residential/Commercial/Industrial

PowerTronics Probe Datalogging User s Manual PowerTronics 143 Raymond Road Candia, N.H

Installation Instructions

THE SOLLATEK SUPPRESSOR RANGE Instruction manual

Maximize Your Uptime: Reducing Risk of Power Supply Failure

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

SmartOnline V 1kVA 700W On-Line Double-Conversion UPS, Tower, C14 inlet, DB9 Serial

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

Line-Interactive UPS with USB and 8 Outlets - 120V, 1000VA, 600W, 50/60 Hz, AVR, ECO Series, ENERGY STAR

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

CATEGORY C CATEGORY B CATEGORY A. The Power to Protect

Successfully Make AC Line Disturbance Measurements

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

Voltage Control Components. & Power Quality Solutions

Gotchas for USB Measurement

Modular UPS S KVA

Installation Instructions

Power Quality. The Overlooked Productivity Variable

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

LPI SST Surge Filters

A+ Certification Guide. Chapter 4 Power Supplies and System Cooling

A Dell Technical White Paper Dell

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal

EP Series II UPS 230 V

White Paper Power and Its Connection to Network Reliability

Cirprotec Technical Article No. 5

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

Mitigation of Voltage Swells I

Series 230 Automatic Transfer Switch

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

A+ Guide to Managing and Maintaining your PC, 6e. Chapter 4 Form Factors and Power Supplies

Surge Protective Devices. STV25K Series. Instruction Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

Liebert IntelliSlot Relay Card

CPC1964BX6. Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information.

MFJ-1164B AC Line RFI Filter

LPI SG + SST Spark Gap Surge Filter

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

AIR COOLED MODULAR RECTIFIER

CHAPTER 5 SMPS. Power Supply

Transcription:

A White Paper from the Experts in Business-Critical Continuity Common Mode Noise The Often Neglected Tenth Power Problem by Michael Boyle

Executive Summary Computers and other electronic equipment play a key role in our lives. Everything from business to our personal enjoyment is addressed by these devices. As electronic equipment becomes more and more a part of our daily lives, the need for clean, quality, power to keep them operating at peak performance and efficiency becomes more and more important. Unfortunately, the quality of the power available can vary greatly from site to site and can affect how computers and other electronic equipment operate. Power issues can cause a computer to slow down due to a disruption of its data stream, or shorten its life, or even destroy electronic equipment. Within power quality, there are nine problems that are commonly defined and addressed (see The other nine problems at the end of this article). Unfortunately, this leaves one very serious problem that is usually overlooked often to the detriment of the reliability of electronic systems. This neglected or tenth problem is common mode noise. fig. 1. Noise captured on an oscilloscope Common mode noise What is noise? In general, noise is any unwanted electrical signal superimposed on an electrical or electronic signal (Figure 1.). 1

have two common components: semi-conductor chips - including CPU, memory and peripheral components and a switch mode power supply that converts line power to the voltages required by the CPU and supporting hardware. fig. 2. Three wire AC conductor (normal mode versus common mode) Common mode noise is usually defined as electrical interference that is measurable between the neutral and ground legs of a typical AC power line. While this is the most classic definition, common mode noise can also be measured between the line (or hot) and ground legs (Figure 2.) Where does noise come from? Noise can be generated by multiple sources including nature, and other electrical devices. For example, fluorescent lights usually create high frequency noise, while motors, pumps, and fans create transient noise as they are turned on and off. Switch mode power supplies inside computers, monitors, and printers, cell phones and wireless phones are also sources of electrical noise that can interfere with other devices. How are semiconductors affected by common mode noise? The semiconductors used in today s products can be very sensitive to noise and transients. In some cases, just touching a semiconductor can result in permanent damage. Further, many of today s semiconductor parts are designed to work with a power supply voltage of either 1.5 or 3.3 volts. With this small voltage, the signals between such parts become more susceptible to distortion thereby potentially transmitting incorrect data. In some cases this simply slows down the system as some form of error correction routine is run, while in other cases, the data error causes the system to lock-up or crash. When noise finds its way into data transmission between computers, the noise level may be low enough not to damage the hardware but data may be corrupted (Figure 3.) What does common mode noise affect? While common mode noise can affect the performance and life of any kind of electronic equipment, this article focuses on how it affects devices with computers. Today, computers are used in a wide variety of applications including ATMs, POS systems, medical systems, avionics and space systems, DVRs, copiers, and video game systems just to name a few. Virtually all computer based systems 2

fig. 3. How noise interferes with a data stream This requires that the data be resent. If this happens often enough, the speed of the network slows down. It is in these ways that common mode noise can keep a computer network from operating at peak efficiency and speed. How does common mode noise enter a Switch Mode Power Supply (SMPS)? The common side of the output of most Switch Mode power supplies is connected to the metal chassis of equipment that it powers. This is the same chassis that is connected to the incoming power line ground wire for safety. It is through this potential path that common mode noise often passes from the power line to the computer based equipment. There is a probability that some portion of this noise will pass through the power supply and into the system logic. While the SMPS itself can be damaged by the noise if it is too great, it is more likely that the semiconductor devices in the equipment will be disrupted or damaged by this noise. Common mode noise (and all other electrical noise, for that matter) can also find unexpected paths through a system. The frequency of the noise (cycles per second) and rate of change (dv/dt) can have a profound impact on the path noise takes, sometimes bypassing the intended conductors and causing unpredictable operation. What is not a solution? A traditional TVSS (Transient Voltage Surge Suppressor) without filtering is often suggested as a solution for noise problems on computer based equipment. None of the many different designs for Transient Voltage Surge Suppressors (TVSS) on the market today, fully control common mode noise. In fact, many TVSS products, including some All Mode models are designed in a way that they unintentionally increase the common mode noise on a system by shunting the transient current to ground and thereby creating a common mode noise which can be more harmful than the normal mode noise which the TVSS is 3

trying to suppress. There are specially designed filter / TVSS combinations such as the ONEAC FilterPro, which are superior to a traditional TVSS in controlling common mode noise and more effective than the TVSS alone. On-line UPS (Uninterruptible Power Supply) are sometimes recommended for common mode noise problems. While they can help solve other problems, they are unlikely to solve the common mode noise problem because most on-line UPS below 3 kva do not have an isolation transformer. As a result, the neutral and ground lines are connected from input to output of the UPS and common mode noise can pass directly through the UPS to the attached equipment. What is the solution? The best solution for controlling common mode noise is a power conditioner or power conditioned UPS with a specially designed transformer and filter combination. Attempting to control common mode noise using just an isolation transformer, even with a grounded electro static shield, is by itself often not successful as the stray capacitance between transformer windings can allow a path for noise to pass through the transformer. How is a power conditioning solution measured? Noise control solutions are measured by how much of the noise they let though their protection barrier. For power conditioners the measurements are usually provided as a let-through voltage which is a measure of how much of the voltage appears on the output of the power conditioner when a specified waveform is applied to its input terminals. The most commonly used input waveform for this test and specification is the ringwave (category A) that is defined in the IEEE C62.41 standard. While a let-through voltage of zero volts is ideal, a common mode (neutral to ground) let-through voltage of ½ volt or less, and a normal mode (line to neutral) let-through voltage of 10 volts or less is the established standard for the best products. Power conditioners that control the normal and common mode let-through voltages to these levels have been proven to resolve most power line noise issues in the field. The other nine problems While controlling common mode noise is critical to achieving a high level of system availability, there are also other, more talked about and easily measured problems that can negatively affect power quality. Below is a brief summary of these problems and some remedies for correcting them. AC Blackout A total loss of power occurring for more than two AC cycles. The blackout may only cause the lights to blink or the power may be off for hours. The solution is a UPS (Uninterruptible Power Supply) or Generator system. Power Sag A short term low voltage condition brought on by the starting of a large piece of equipment, utility switching, or temporary overload of the electrical system. The result is a low voltage condition that lasts a couple cycles to a couple seconds. The solution is an online or line-interactive UPS or voltage regulating power conditioner. Brownout A brownout has the same characteristics as a power sag but for much longer time duration. A brownout can last from minutes to days or even longer. The solution is an on-line or line-interactive UPS or voltage regulating power conditioner. High Voltage Spike A quickly rising high amplitude voltage spike that lasts ½ cycle or less, but is capable of causing damage because of the high voltage and current potential. This could be the result of a lightning strike that can exceed 6 kva. A TVSS (Transient Voltage 4

Surge Suppressor) can be used to suppress this spike but will typically clamp the voltage at 330 Volts or more. A better solution is a power conditioner or power conditioned UPS that meets a 10 V (Normal Mode) and ½ V (common mode) let-through specification. Voltage Surge A voltage that has increased RMS voltage amplitude for multiple cycles, it is usually of short time duration but could last for hours or even days. The solution is an on-line or line-interactive UPS or voltage regulating power conditioner. Normal mode electrical line noise A high frequency noise between line (L) and neutral (N) conductors that is superimposed on the main AC sinewave causing a distortion of the sinewave. The source of the noise can be either radiated RFI or induced EMI on to the line and neutral. Sources include transmitting devices, fluorescent lighting, computers and electronics, motors and pumps, etc. The solution is power conditioner or power conditioned UPS system. Frequency variation - A random or periodic change from the nominal frequency (60 Hz or 50 Hz) that is expected from the power line or generator. While most of North America, Western Europe, and Japan have a fairly stable power line frequency, some parts of the world are more likely to suffer with this problem. Operation from generators that are old or not maintained can also produce frequencies that are unstable. The solution is an on-line UPS. Harmonic Distortion A distorted AC Sinewave that is a result of non linear loads such as rectifiers and similar circuits found in equipment with switch mode power supplies, and VFD (variable frequency drives). Common problems created by harmonic distortion include difficulty synchronizing equipment to the line and overheating of equipment and transformers. Solutions placed at the source include drive isolation transformers and Line Reactors. The solution placed to protect the load is an on-line UPS. Conclusion There are a large number of different devices designed to reduce the effects of nine of the ten power problems found in our world. The tenth problem, common mode noise is the most over looked power problem today and it can have devastating effects on computers and other equipment. In today s environment quality power is essential. Emerson Network Power, ONEAC AC Power offers a complete line of power conditioners and power conditioned UPS equipment to reduce the 3 Ds, Disruption, Degradation, and Destruction that common mode noise and the other nine power quality problems will cause over the life of your valuable equipment. Switching Transient is a fast high voltage spike with very short time duration. They are mainly caused by power factor correction capacitors being switched on and off the power grid. Not only can they cause damage to the load but to the circuit breakers protecting the load as well. The solution to protect the load is an on-line UPS. 5

About the author Michael Boyle Michael Boyle is currently a Technical Product Manager for ONEAC AC Power. He has a BSEET from DeVry Institute of Technology. Emerson Network Power ONEAC Product and Services 27944 North Bradley road Libertyville, IL 60048 800 327 8801 Phone (US & Canada) 847 816 6000 Phone (outside US) oneac.com Michael has over 10 years experience in the power quality field. While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. Specifications subject to change without notice. Business-Critical Continuity, Emerson Network Power and Emerson Network Power Logo are trademarks of Emerson Electric Co. or one of its affiliated companies. 2011 Emerson Electric Co. 950-032 @ Rev B Emerson Network power. The global leader in enabling Business-Critical Continuity EmersonNetworkPower.com AC Power Systems Embedded Power Precision Cooling Site Monitoring and Services Connectivity Inbound Power Outside Plant Rack & Integrated Cabinets DC Power Systems Power Switching & Controls Surge Protection Services