Agilent InfiniiMax II 1168A/1169A Probes

Similar documents
Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent Technologies E5385A 100-Pin Probe

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Agilent CSV Export Utility

Agilent OpenLAB. Data Store. Maintenance Guide

Agilent OpenLAB. Data Store. Backup and Restore Guide

Agilent N5410A Fibre Channel Automated Test Application

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent Series Logic Analysis System

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Agilent OpenLAB Chromatography Data System (CDS)

86100 Series Infiniium DCA Oscilloscope

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

BenchCel Workstations Software

Agilent 1260 Infinity Purification Solution

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent N5394A DVI Electrical Performance Validation and Compliance Software

Agilent OBSAI Protocol Tester

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Keysight Add Source and Receiver Attenuators Upgrade Kit

Firmware Guide. Keysight PXIe Chassis Family

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Agilent OpenLAB Chromatography Data System (CDS)

Setting Up Probes. Online Help

Keysight N7015A/16A Type-C Test Kit. User Guide

Agilent OpenLAB Chromatography Data System

Agilent ChemStation Plus

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Agilent Dissolution Tester Driver

Agilent ChemStation Plus

Nimsoft Monitor. proxy Guide. v3.1 series

Agilent W2635A and W2636A

Agilent EZChrom SI. Startup Guide

Agilent E2094M IO Libraries

Microscan Barcode Reader

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

Agilent OpenLAB Data Store. Maintenance Guide

Agilent OpenLAB Chromatography Data System (CDS)

Quick Start/Installation Guide

Keysight E7515A UXM Firmware Update Tool

Agilent Gb/s Serial BERT

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Agilent OpenLAB Chromatography Data System (CDS)

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Agilent OpenLAB Chromatography Data System (CDS)

Automated Plate Labeling

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Keysight M9393A PXIe Vector Signal Analyzer

Agilent OpenLAB Chromatography Data System

G5584A Labware MiniHub

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Agilent Softtouch 2.0 Midbus Probe

Advanced Test Equipment Rentals ATEC (2832)

* * Agilent Power Distribution Unit (PDU) Installation Guide

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

87421/22A Power Supply. Operating and Service Manual

Agilent N4219B Packet Analysis Probe for Serial ATA. User s Guide

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Automated Plate Centrifugation

Agilent N5393B PCI Express Automated Test Application

Agilent 89600B VSA. Software Installation Guide

Agilent ChemStation for UV-visible Spectroscopy

DDR Setup Assistant. Online Help

Agilent U2941A Parametric Test Fixture

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Agilent G2721AA/G2733AA

Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Agilent Genomic Workbench 6.0

Agilent OpenLAB Data Store Administration. Guide for Administrators

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Agilent Connector Plate

User s Guide. Keysight W2635A and W2636A DDR3 BGA Probe Adapters for Oscilloscopes

Nimsoft Monitor. sysstat Guide. v1.1 series

Agilent 16442B. User s Guide. Agilent Technologies

Agilent OpenLAB ECM Intelligent Reporter

Unified Infrastructure Management Compatibility Matrix June 26, 2015

Agilent N5430A User Defined Function

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent W2100 Antenna Modeling Design System

Cary 50. Pre-Installation Manual

Agilent N5393C PCI Express Automated Test Application

Errata. Agilent References in this manual. About this manual. Support for your product

Unified Infrastructure Management Compatibility Matrix September 05, 2017

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

PlateLoc ActiveX v3.1

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Agilent 70612B K18 Switch Matrix

Transcription:

Agilent InfiniiMax II 1168A/1169A Probes Handling Guide Agilent Technologies

Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number 01169-97009 Edition First edition, August 2008 Printed in USA Agilent Technologies, Inc. 1601 California Street Palo Alto, CA 94304 USA Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

Agilent InfiniiMax II 1168A/1169A Probes Handling Guide This manual will assist you in properly handling your InfiniiMax II 1168A/1169A probe amplifiers and probe heads to maximize their lifetime of operation and maintain their high performance. Connecting / Disconnecting Probe Heads Whenever you disconnect a probe head from an InfiniiMax II amplifier, pull the probe head connectors straight out of the sockets as shown in Figure 1. When removing or connecting a probe head, hold the amplifier by grasping the indentations located on the sides of the amplifier (as shown in Figure 1). There are also indentations on many of the probe head sockets so you have a convenient place to grasp there as well. Figure 1 Pull the probe head straight out to disconnect it from the amplifier. When connecting a probe head to an amplifier, push straight in also. Agilent Technologies 1

Never bend the probe head in order to pop it loose from the amplifier. Also, do not wiggle the probe head up and down or twist it to remove the connectors from the sockets. This can damage the pins in the amplifier or the probe head itself. Figure 2 is an example of an improper way to disconnect the probe head. Figure 2 An improper way to disconnect a probe head from an amplifier 2 InfiniiMax II Handling Guide

To see if the pins in the probe amplifier are bent, visually inspect them by looking in the sockets on the amplifier. Notice in Figure 3 that the pins are straight (as they should be). Pins Figure 3 Straight pins in an amplifier If you connect and disconnect probe heads using the appropriate method, these pins should not bend. Always remember to apply enough force to pull the probe head straight out or push it straight in. Do not wiggle, twist, or bend it in any way. Handling the Probe Cable In general, you need to be careful not to kink the cable, twist it, or bend it too much. For example, slamming a drawer or dropping a heavy item on a cable can kink it and significantly degrade the probe s performance. InfiniiMax II Handling Guide 3

Also, when a probe is attached to an oscilloscope, you need to be careful not to let a chair or other object crash into the face of the oscilloscope because it will hit the probe cable where it exits the probe amplifier and bend it well beyond its limit. When storing the probe, it is best to coil the cable in a large radius and avoid a net twist in the cable during the process. This can be done in a similar manner to how garden hoses or extension cords are typically coiled. You can start by wrapping the cable around your thumb (Figure 4 - first picture). Then continue to circle your thumb, but provide a slight twist with each rotation. This will allow the cable rotations to lie flat against each other and will eliminate the net twisting of the cable in the end. Figure 4 The recommended way to coil and store your probe 4 InfiniiMax II Handling Guide

Note that the radius of the coil must be fairly large so it does not induce kinking or bending. Connecting an InfiniiMax II Probe to an Oscilloscope The InfiniiMax II probes are only meant to be plugged into gold plated BNCs (like those on Infiniium oscilloscopes). Simply push the probe into the BNC and then push the locking mechanism to the right to secure the probe to the oscilloscope (Figure 5). How far the locking mechanism can be pushed to the right varies and will not be the same for every user. Therefore, do not try to force it further to the right because you believe it is unlocked. Instead, gently push it until it is snug. Figure 5 Properly connecting a probe to an oscilloscope InfiniiMax II Handling Guide 5

Handling the Probe Amplifier The probe amplifier contains a delicate circuit board. You, therefore, need to treat it carefully and take standard precautions (for example, not dropping it repeatedly or from large heights, not getting it wet, not smashing it with heavy objects, etc.). Additionally, these probes are sensitive ESD devices so standard precautions need to be used to not ruin the probe from the build-up of static charges. Common Issues with Probe Heads Resistor Tips Differential Browser Probe Head There are a variety of probe heads compatible with the InfiniiMax II amplifiers, but this section will cover some of the more commonly seen misuses. Many probe heads come equipped with replaceable resistor tips. If these resistor tips break, you can replace the tips without having to replace the entire probe head or having to send it back for repair. The 1168A and 11169A Differential and Single-ended Probes User s Guide details the replacement procedures for the various resistor tips available. This manual can be downloaded from www.agilent.com and also walks you through the step-by-step processes of trimming and soldering resistor tips to DUTs (devices under test). Do not use the differential browser probe head as a tool to scrape solder mask or other things off of a circuit board. When using this probe head, the blue tips can easily be broken off if the browser is not used properly. The proper way to use this probe head is such that the blue tips remain vertical during measurements (Figure 6). 6 InfiniiMax II Handling Guide

Figure 6 The proper vertical orientation of the blue tips on the differential browser probe head SMA Probe Heads The InfiniiMax II probe amplifier can become damaged when used with the N5380A or E2695A SMA probe heads. Use the Agilent N5380-64701 SMA Head Support to prevent damage. Make sure to plug the probe amplifier into the SMA head before installing the SMA Head Support and do not attempt to plug or unplug the SMA head from the probe amplifier while it is in the SMA Head Support housing. InfiniiMax II Handling Guide 7

Below is a picture showing how to attach the SMA Head Support using two provided screws. Figure 7 Attaching the SMA Head Support Temperature Rating The InfiniiMax probe amplifiers have a specified operating temperature range of 5 o C to 40 o C. However, the probe heads can be operated over a much larger range of temperatures. If you need to make measurements at temperatures outside the range of the amplifier, the N5450A Extreme Temperature Cable Extension Kit is your solution. These cables can be used to physically separate the amplifier from the probe head to allow you to operate the probe head inside a temperature chamber while the probe amplifier remains outside the chamber. For more information on this product, refer to the 1168A and 11169A Differential and Single-ended Probes User s Guide. 8 InfiniiMax II Handling Guide

Securing Probe Heads and Amplifiers to Your DUTs When soldering a probe head to a circuit, you should first provide some strain relief by using low temperature hot glue (use as little as possible) or non-conductive double-sided tape. Do not use super glue and do not get the low temperature hot glue on the actual probe head tip as this can damage the precision components of your probing system (only use the low temperature hot glue on the probe head cables). The provided velcro pads can be used to secure your probe amplifier casing to the board. Figure 8 Correct securing methods Figure 9 Incorrect securing method because glue is placed on the probe head tip InfiniiMax II Handling Guide 9

Once strain relief has been provided, solder the probe tip to the circuit board (refer to 1168A and 11169A Differential and Single-ended Probes User s Guide for tips on soldering) and then plug the probe head into the probe amplifier. 10 InfiniiMax II Handling Guide

www.agilent.com In This Book Agilent Technologies, Inc. 2008 Printed in USA 08/08 First Edition, August 2008 *01169-97009* 01169-97009 Agilent Technologies