INSTRUCTION MANUAL MODEL 8081 DIGITAL RECORDER

Similar documents
Model 5270 Data Acquisition and Control Software Installation and Technical Support Manual

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

LINAX Series Videographic Recorders

Instruction Manual July sitrans RD SOFTWARE

The following steps will allow you to install and quickly begin using DevCom2000:

RST INSTRUMENTS LTD.

SGT-600 SAFETY GROUND TESTER

RST INSTRUMENTS LTD.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

Computrac Max 5000XL. Installation & Maintenance Instructions. Web Server Operation Manual

TagTemp-NFC 3 TECHNICAL DATA 1 INTRODUCTION 2 MECHANICAL INSTALATION. TEMPERATURE LOGGER INSTRUCTIONS MANUAL V 1.0x D

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

9120 Redundant Probe System (RPSC)

6-Channel Monitor. Installation and Operation Manual

The following steps will allow you to install and quickly begin using DevCom:

PowerView. Model PV-101 User s Guide. Rev Catalog Section 78

ARTiPRO. User Manual. (Model 910 & 920)

Podium Plus Data Analysis Software. User Manual. SWIS10 Version

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

Avaya Call Management System Network Reporting

NORDSON CORPORATION AMHERST, OHIO USA

QUICK START. DevCom2000 User Manual

PowerView. Model PV-101-A, V2.3 User s Guide Section 78

F4T Touch Screen Controller User s Guide

ncompass CM i4.3 Multi-loop Controller Configuration Manual

3700 SERIES USER MANUAL

Vision Express Engraver S5 Installation Guide Vision Engraving & Routing Systems

REMOTE FRONT PANEL EMULATION

The merisuite CG Application

VBT-75 S2 VACUUM BOTTLE TESTER

Vision VE810 Engraver S5 Installation Guide Vision Engraving & Routing Systems

F4T Touch Screen Controller User s Guide

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

Allegro CX Field PC Release 1.07a

FX2-CHILLER. Digital Control. Operations Manual

N2KExtractor. Maretron Data Extraction Software User s Manual

testo EasyClimate Software Instruction manual

PowerView. Model PV-101-C User s Guide Version Catalog Section 78

HawkEye 45T Display User Manual

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

Moomba Boats PV480 Color Display

RST INSTRUMENTS LTD.

The following steps will allow you to install and quickly begin using DevCom:

N2KExtractor. NMEA 2000 Data Extractor Software. User s Manual

Aimetis Thin Client 2.7. User Guide

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

Esensors. Websensor User Guide. Save trees. Print only when necessary

FH125/FT121. Temperature / Humidity LCD Graphing Logger FH125 SET CURSOR. 1 Hour/Div 1 1 : 12 : 23 01/03/02 (ESC)

Videographic Recorders

ACTpro Single Door IP Controller. Operating & Installation Instructions

BESTCOMSPlus Software

ATEK Intelligence Platform

xponent Version 4.2 RELEASE NOTES

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

FX 2 Instruction Manual

Multi Channel Data Logger

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

TDSPTD Protocol Trigger and Decode Application Online Help

Lookin Body Web User Manual

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

Chapter 3 Operating instructions

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Avigilon Control Center Web Client User Guide

cmt Quick Start Guide

2. INSTALLING AALTO CONTROL SYSTEM

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

Ovation Process Historian

Standard Operating Procedure For The Kaye Validator 2000 Thermal Mapping System

Webview Help Guide. OnSite Telemetry System. Distributed by: Chart Inc th Street NW New Prague, MN USA (800)

USER MANUAL. Mouldflo Software (GUI) Mouldflo A/S Copyright 2016

Smith Meter ETR-1000 Electronic Register

TempLog & RH/TempLog User Guide. Sixth Edition First print Printed in July

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06

Software Operations Manual

LOREX CLIENT 3.0 SOFTWARE MANUAL IRMS Integrated Remote Management Software

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

TopGuard Online Help PATROL AND PATROL PLUS

FTI 3000 Manual Lookout Road, Boulder, CO Phone: Fax:

HelmView 450 Model HV450. Operation Manual Section 78

SAP BusinessObjects Live Office User Guide SAP BusinessObjects Business Intelligence platform 4.1 Support Package 2

PF3100 Quick User Guide R 0.3 PROFIRE PF3100. Quick User Guide. PROFIRE Page 1 of 13

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis

installation quick guide integrated access control & environmental monitoring

User Guide File Transfer Scheduler. LINAX Series LINAX A310 CAMILLE BAUER

Full User Manual and Quick Start Guide

Operator Manual. MS1000 Software. Trencher Monitoring System

PanelView Plus and Text Historian Guide

AX200. Installation Guide

TAC Vista Webstation. Operating Manual

Amcrest 960H DVR Quick Start Guide

RADI-CEM. User manual. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy. Tel Fax

CVT-765 Capacitor Voltage Transformer Ratio Tester

TITAN S8. Portable Data Acquisition Logger. Product User Guide

Amb-OS User Interface Installation Manual

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1

PF31XX FAMILY FIRMWARE UPDATE GUIDE. v1.2 Revised Nov 29, 2016

Transcription:

INSTRUCTION MANUAL MODEL 8081 DIGITAL RECORDER Revision B February 2013 P/N 8081-0005 S/N 2001 N. Indianwood Ave., Broken Arrow, Oklahoma 74012 Tel: 918-250-7200 Telefax: 918-459-0165 E-mail: Chandler.sales@ametek.com Website: www.chandlereng.com

Copyright 2013, by Chandler Engineering Company, LLC P.O. Box 470710 Tulsa, Oklahoma 74147 All rights reserved. Reproduction or use of contents in any manner is prohibited without express permission from Chandler Engineering Company, LLC. While every precaution has been taken in the preparation of this manual, the publisher assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. This publication contains the following trademarks and/or registered trademarks for: AMETEK and CHANDLER ENGINEERING. These trademarks or registered trademarks and stylized logos are all owned by AMETEK, Inc. All other company, product and service names and logos are trademarks or service marks of their respective owners.

TABLE OF CONTENTS T-1 Table of Contents Page General Information... P-1 Application of the Recorder... P-1 Keypad Functions... P-2 Safety Requirements... P-4 Where to Find Help... P-4 Section 1 Saving and Exporting Data... 1-1 USB Drive Specifications... 1-1 Recorder Operation... 1-1 Starting a Test... 1-2 Ending a Test... 1-2 Data Storage Rate... 1-3 File Format... 1-3 File Name Format... 1-3 Section 2 File Import with 5270 DACS... 2-1 Section 3 Screens and Menus... 3-1 Main Menu... 3-1 Home Screen (Vertical Trend)... 3-2 Horizontal Trend Screen... 3-2 Vertical Bar Graph Screen... 3-3 Horizontal Bar Graph Screen... 3-3 Numeric Screen... 3-4 Recorder Operation Screen... 3-4 View Menu... 3-5 History... 3-6 History Menu... 3-6 Section 4 Advanced Configuration... 4-1 Saving a Configuration... 4-1 Restoring a Previous Configuration... 4-2 Calibration... 4-2 Changing Chart Speed... 4-3 Changing Data Storage Interval... 4-3

T-2 TABLE OF CONTENTS THIS PAGE IS INTENTIONALLY LEFT BLANK

General Information Application of the Recorder GENERAL INFORMATION P-1 The Chandler 5270 DACS software is designed to provide data logging and control capability for Chandler cement consistometers and other instruments. Data is collected directly from the instrument in real-time and stored to a file on a PC by the 5270 DACS software. Additionally, a digital recorder is provided on the front panel of the instrument as a back-up system. In the event of a PC or communication failure, data from the on-board recorder can be retrieved and imported into 5270. The connectivity scheme is illustrated below. Data Temperature Pressure Consistency Wall Temperature Backup Internal Flash Storage 5270 DACS Figure 1 Digital Recorder Connectivity

P-2 PREFACE Keypad Functions The front panel consists of 4 buttons (shown below). Figure 2 - Keypad Layout When a menu is not displayed, the main screens can be cycled through using the buttons. Pressing the button will display the menu screen or to navigate back to the previous screen, depending on the context. The button is used to select a highlighted parameter or accept an entered value.

GENERAL INFORMATION P-3 Table 1 - Specifications Features Summary 4 Channel Data Collection USB File Transfer CSV Files Compatible with Chandler Engineering 5270 Software On-Screen Trending and Data Display Mechanical and Electrical Input Voltage: 100-230 VAC ± 15% 48-62 Hz Input Power: 9W Environment Operating Temperature: 10 to 49 C (50 to 120 F)

P-4 PREFACE Safety Requirements READ BEFORE ATTEMPTING OPERATION OF INSTRUMENT Any instrument that is capable of the extremely high temperatures and pressures, such as a cement consistometer should always be operated with CAUTION. The instrument is designed for operator safety, however to ensure that safety: Locate the instrument in a low traffic area. Post signs where the instrument is being operated, to warn non-operating personnel. Read and understand instructions before attempting instrument operation; observe caution notes! Observe and follow the Warning Labels on the instrument. Never exceed the instrument maximum pressure and temperature ratings secured on the machine. Always disconnect main power to the instrument before attempting any repair; HIGH VOLTAGE CAN KILL!!! Keep front access door closed when operating instrument. Turn off the heater at completion of each test! Oil in an open cylinder exposed to atmospheric conditions can result in fire, if heated past its "flash" point. A fire extinguisher, Type 8 BC should be located within 50 feet of instrument. Before attempting to operate the instrument, the operator should read and study the instrument s user manual to become familiar with the operation of the equipment. Where to Find Help On-site training classes are available. For more information, contact our Sales Department at Chandler Engineering (Telephone: 918-250-7200, Fax: 918-459- 0165, e-mail: chandler.sales@ametek.com, or visit our website at: www.chandlereng.com.) In the event of problems, your local sales representative will be able to help or you can contact the personnel at Chandler Engineering using the following: Telephone: 918-250-7200 FAX: 918-459-0165 E-mail: chandler.sales@ametek.com Website: www.chandlereng.com

SECTION 1 - SAVING AND EXPORTING DATA 1-1 Section 1 Saving and Exporting Data The digital recorder is designed to record data continuously to its own internal flash memory. In order to extract data from the instrument, it must be exported (i.e. archived ) to an external USB drive. The advantages of using a USB drive to transfer data include: Simple to operate Data retrieval does not depend on availability of any particular PC, server or network. Data is transportable to any PC with a USB port for import into 5270. USB Drive Specifications A standard USB drive (< 8GB) is required for exporting (i.e. archiving ) data. The following requirements must be met: Compatible with USB 1.1 standard or greater Drive size must be 8GB or less FAT or FAT32 file system (NTFS not supported) USB hubs are not supported U3 smart drives are not recommended Recorder Operation When the hardware is recording data, a green R icon is displayed in the lower left-hand corner of the chart and data view screens. When the device is not recording data, a red pause icon is displayed in its place. If a wrench icon is displayed, the device is not recording data because it is being configured by a user. NOTE: If the icon is not displayed in the lower right corner of the home screen, data will not be stored even though the screen is being updated with live data. The operation of the recorder is described in the following illustration.

1-2 SECTION 1 - SAVING AND EXPORTING DATA Idle (Paused) Data display and plot updated No data storage Start Test Run / Stop = checked Internal data storage resumed Stop Test Run / Stop = X Data storage paused USB archive is created or brought to date, if drive is installed Test Operation Continuous data storage (internal flash) 50MB Buffer Size (25 days @ 1 sample/sec) Figure 3 - Recorder Operation Cycle The recorder is factory configured to remain paused (i.e. not storing data) until a test is started. Once a test is started, data is stored continuously. Once a test has been stopped, data recording is paused and an archive file is automatically created on the USB drive, if connected. At the end of a test, the recorder is factory configured to bring the USB archive up to date, meaning any data not already archived to a USB drive will be transferred. Therefore, if a USB drive is always inserted, a single data file will be created for each test. Starting a Test To start a test, navigate to the Recorder Operation screen, using the buttons. Press the button once to highlight the Run/Stop field. To toggle the Run/Stop field, press the button. A Test Started message is stored to the event log and internal data storage is enabled once the Run/Stop field is changed from paused ( ) to running ( ). Ending a Test To end a test, navigate to the Recorder Operation screen, using the buttons. Press the button once to highlight the Run/Stop field. To toggle the Run/Stop field, press again. A Test Stopped message is stored to the event log, internal data storage is suspended and a USB archive is automatically attempted once the Run/Stop field is changed from running ( ) to paused ( ).

SECTION 1 - SAVING AND EXPORTING DATA 1-3 Data Storage Rate The recorder is factory configured to save data at a rate of 1 sample per second, which provides approximately 25 days (600 hours) of internal storage. Once the internal buffer is full, the oldest data in the buffer is overwritten. To change the data storage rate, refer to the Advanced Configuration section. File Format The recorder is factory configured to generate comma separated value (CSV) files, which can be opened via Chandler Engineering 5270 software, or a third-party application, such as Microsoft Excel. The data is stored in column format, with the signal name and units located at the top of the appropriate columns. Alarms or messages, such as Test Started or Test Stopped are included in the file. An example cement consistometer test file is shown below. Date/Time Temperature Pressure Consistency Wall Temperature 9/13/2012 16:19:36 Test Started F PSI Bc F 9/13/2012 16:19:37 169 9000 45 198 9/13/2012 16:19:38 174 9167 46 198 9/13/2012 16:19:39 179 9333 47 199 9/13/2012 17:48:54 392 18167 91 384 9/13/2012 17:48:55 390 18000 90 384 9/13/2012 17:48:55 Test Stopped File Name Format File names are stored in a format that identifies the instrument model number as well as the starting and ending time and date of the data stored within the file. A typical filename is shown below: S = Start Starting Time (hh mm ss) E = End 7322~S09-13-12-16-19-36~E09-13-12-17-48-55.csv Model Number Starting Date (mm dd yy) Ending Date (mm dd yy) Ending Time (hh mm ss)

1-4 SECTION 1 - SAVING AND EXPORTING DATA THIS PAGE IS INTENTIONALLY LEFT BLANK.

SECTION 2 - FILE IMPORT WITH 5270 DACS 2-1 Section 2 File Import with 5270 DACS The Chandler Engineering 5270 DACS software (Version 2.4 or greater) is capable of importing an archive file from the digital recorder, or any device capable of generating the same file format. Acceptable file formats include comma (csv) or tabdelimited text files. To import a file, insert the USB drive containing the archive or copy the file to a folder or network location that is accessible from 5270. Within 5270, the File->Import function can be used with an existing template (.tst file), or an instrument and test profile can be selected to create the template from. This allows the imported data to populate a 5270 test file with all the necessary data and graph formats, while generating calculated values and calculated curves, if applicable. Refer to the 5270 help system for more information on importing files.

2-2 SECTION 2 - FILE IMPORT WITH 5270 DACS THIS PAGE IS INTENTIONALLY LEFT BLANK

Section 3 Screens and Menus Main Menu SECTION 3 SCREENS AND MENUS 3-1 Figure 4 - Main Menu The main menu (shown above) can be accessed by pressing the button. Depending on which screen is currently displayed, the button may need to be pressed more than once. Pressing the button from the main menu will cause the home screen to be displayed. To make a selection, use the buttons and press the button. The following selections can be made. Home This selection is the same as pressing the button. It allows the user to navigate to the home screen, which displays a vertical trend, similar to that of a traditional paper chart recorder. Go to view This selection allows the user to navigate to the view menu. History This selection allows the user to view historical data (refer to the History section for details). Faceplate cycling on/off This selection toggles faceplate cycling on or off. Faceplate cycling refers to the data display at the top of the vertical or horizontal trend screens. When faceplate cycling is on, the name and value of each signal is periodically displayed. When faceplate cycling is off, the user must press the button to manually cycle through the signals in order to change which signal is displayed at the top of the graph. Operator notes This selection allows an operator to write a note to the chart, which is stored along with the data. Demand archiving This selection allows an advanced user to archive data to an FTP server in-lieu of a USB drive. Configuring the recorder to function with an FTP server is not covered in this manual. Contact Chandler Engineering for more information about FTP functionality. Log in / out In order to make configuration changes, a user must first log in. There are 4 access levels: Logged out, Operator, Supervisor and Engineer. Each level has specific restrictions, with Engineer providing the highest level of access. When logged in as Engineer, data recording is temporarily disabled.

3-2 SECTION 3 SCREENS AND MENUS Home Screen (Vertical Trend) Figure 5 - Home (Vertical Trend) Screen The home screen (shown above) displays a vertical trend of all configured signals, with a digital display at the top of the screen. When faceplate cycling is on, the name and value of each signal is periodically displayed here. When faceplate cycling is off, the user must press the button to manually cycle through the signals in order to change which signal is displayed at the top of the screen. Horizontal Trend Screen Figure 6 - Horizontal Trend Screen The horizontal trend screen (shown above) shows a horizontal trend of all configured signals, with a digital display at the top of the screen. When faceplate cycling is on, the name and value of each signal is periodically displayed here. When faceplate cycling is off, the user must press the button to manually cycle through the signals in order to change which signal is displayed at the top of the screen.

SECTION 3 SCREENS AND MENUS 3-3 Vertical Bar Graph Screen Figure 7 - Vertical Bar Graph Screen The vertical bar graph screen (shown above) shows a vertical bar graph of all configured signals, with a digital display at the top of the screen. When faceplate cycling is on, the name and value of each signal is periodically displayed here. When faceplate cycling is off, the user must press the button to manually cycle through the signals in order to change which signal is displayed at the top of the screen. Horizontal Bar Graph Screen Figure 8 - Horizontal Bar Graph Screen The horizontal bar graph screen (shown above) shows a horizontal bar graph of all configured signals. To toggle between the display of signal names and values, press the button.

3-4 SECTION 3 SCREENS AND MENUS Numeric Screen Figure 9 - Numeric Screen The numeric screen (shown above) displays all configured signals and their current values. Recorder Operation Screen Figure 10 - Recorder Operation Screen The recorder operation screen (shown above) is used to start and stop a test. Refer to the Recorder Operation section of this manual for more information.

SECTION 3 SCREENS AND MENUS 3-5 View Menu Figure 11 - View Menu The view menu (shown above) can be used to navigate to any of the screens described above, or to screens pertaining to the following: Alarm Summary This screen displays any currently active process alarms, such as over-temperature, over-pressure, etc. If any process alarms are active, the symbol will be displayed at the bottom of the home screen. System Alarms This screen displays any currently active system alarms, such as Media Missing (USB drive not installed). If any system alarms are active, the symbol will be displayed at the bottom of the home screen. Message Summary This screen displays a list of messages, including a log of all configuration changes, firmware upgrades, started and stopped tests, archive operations, etc. When a new message is logged, the icon will be displayed at the bottom of the home screen.

3-6 SECTION 3 SCREENS AND MENUS History The recorder allows historical data to be viewed from the LCD, when History is selected from the main menu. In the History screen, the chart background will change from white to dark grey, as shown below. Figure 12 - History Screen From the History screen, the chart can be scrolled forward or backward using the buttons. Pressing the button brings up the History menu. History Menu Figure 13 - History Menu The History menu (shown above) is accessed from the History screen. The following selections are available. Zoom In/Out This selection changes the length of time displayed on the history chart. Trend If All Points is selected, all channels are displayed simultaneously. If Each Point is selected, only one channel is displayed, and the button can be used to cycle through the available channels. Show Messages This selection shows or hides messages in the history chart. Exit History This selection closes the history view and returns to real-time display of data.

SECTION 4 - ADVANCED CONFIGURATION 4-1 Section 4 Advanced Configuration The digital recorder has many configurable parameters. In addition to configuration from the front panel, the Eurotherm itools software can be used to create, store, retrieve and apply settings for virtually every aspect of the recorder. For a complete description of all configurable parameters and a comprehensive listing of advanced features not covered in this document, refer to the Eurotherm nanodac recorder manual at www.eurotherm.com. The following sections cover advanced configuration topics likely to be encountered in a typical usage scenario. Saving a Configuration The currently selected configuration can be saved directly to a clone file on the USB drive, which can be used to restore the current configuration later, or to duplicate the device s settings on other devices. To access the save/restore menu, go to the main menu, select log in, then log in as Engineer. The default configuration requires a password of 100 to be entered. Once logged in, the Configuration menu is automatically selected. The menu selections to save/restore a configuration are: Configuration menu-> Instrument-> Save/Restore From the Instrument Save/Restore screen, select the Save operation. If a USB drive is installed, a file browser is displayed. Select <New File> and enter a filename when prompted. Alternatively, the Eurotherm itools software (available at www.eurotherm.com) can be used to save a clone file. Connectivity to itools requires an Ethernet cable to be connected between the rear of the recorder and a PC. The necessary setup information can be found in the Eurotherm nanodac recorder manual at www.eurotherm.com.

4-2 SECTION 4 ADVANCED CONFIGURATON Restoring a Previous Configuration The instrument s configuration may be loaded from a previously created clone file on the USB drive, using the Restore feature. To access the save/restore menu, go to the main menu, select log in, then log in as Engineer. The default configuration requires a password of 100 to be entered. Once logged in, the Configuration menu is automatically selected. The menu selections to save/restore a configuration are: Configuration menu-> Instrument-> Save/Restore From the Instrument Save/Restore screen, select the Restore operation. If a USB drive is installed, a file browser is displayed. Select the appropriate file to continue. Alternatively, the Eurotherm itools software (available at www.eurotherm.com) can be used to load a clone file. Connectivity to itools requires an Ethernet cable to be connected between the rear of the recorder and a PC. The necessary setup information can be found in the Eurotherm nanodac recorder manual at www.eurotherm.com. Calibration To calibrate a signal, go to the main menu, select log in, then log in as Engineer. The default configuration requires a password of 100 to be entered. Once logged in, the Configuration menu is automatically selected. The menu selections to access a channel s configuration menu are: Configuration menu-> Channel-> (select 1,2,3 or 4)-> Main From the channel s configuration menu, an Offset value may be entered for thermocouple signals. For voltage or resistance signals, such as Consistency or Pressure, the following values are also adjustable: Input Low The low range of the raw input (volts, mv, ma, Ohms, etc. defined by the Type field.) Input High The high range of the raw input (volts, mv, ma, Ohms, etc. defined by the Type field.) Scale Low The calibrated value (in units specified in the Units field) that corresponds to the Input Low value. Scale High The calibrated value (in units specified in the Units field) that corresponds to the Input High value.

SECTION 4 - ADVANCED CONFIGURATION 4-3 Changing Chart Speed The chart speed can be changed so that a longer or shorter period of time is displayed on the horizontal and vertical trend screens. To access the appropriate menu, go to the main menu, select log in, then log in as Engineer. The default configuration requires a password of 100 to be entered. Once logged in, the Configuration menu is automatically selected. The required menu selections are: Configuration menu-> Group-> Trend-> Interval Note: Changing the remaining settings in the Group->Trend menu is NOT recommended as it may affect compatibility with the 5270 DACS software. Changing Data Storage Interval The data storage interval can be changed to an interval ranging from one sample per 0.125 seconds to 1 sample per hour. This setting affects the data storage rate to internal flash, which is in-turn reflected in the sample rate of the archived data. To access the appropriate menu, go to the main menu, select log in, then log in as Engineer. The default configuration requires a password of 100 to be entered. Once logged in, the Configuration menu is automatically selected. The required menu selections are: Configuration menu-> Group-> Recording-> Interval Note: Changing the remaining settings in the Group->Recording menu is NOT recommended as it may affect compatibility with the 5270 DACS software.

4-4 SECTION 4 ADVANCED CONFIGURATON THIS PAGE IS INTENTIONALLY LEFT BLANK