IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Similar documents
IST ULTRASTAB Power Supply for high precision transducers

ITZ FLEX ULTRASTAB USER GUIDE /2 Page 1 of 32

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

DS5000-IBFS. 5kA rms - 8kA DC Fluxgate current transducer. Features. Description. Application. Precision Innovation /

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

Switching Power Supply

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Series Watt DC Power Supplies

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

I/O Expansion Module Installation & Reference

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Keysight U8030 Series Triple-Output DC Power Supplies

VP ELECTRONIQUE MASSY - Tel

Variable-switching Regulated DC Power Supplies PAS Series

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Expansion Module HZS 541-1S

Installation Manual for D244X Series 24-volt Power Supplies

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

Zelio Control-modular measurement and control relays 1

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

BGS (at min. setting) BGS (at max. setting)

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

LED Driver Linear / area fixed output

Suitable for detecting transparent films or transparent bottles

TXP3500/4000 Series AC-DC Industrial PSU

MODEL: R1M-GH. PC Recorders R1M Series

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

DINALOG A 144 x 36 A1400 Light-Strip Indicator

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

MINI MCR-SL-UI-2I(-SP)(-NC)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Manual Fiber Optic Interfaces

PRD/PRDW Series. Long Distance Type

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

GS202 Encoder Switch

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

A0750 AC-DC POWER MODULE

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

GFK-2415A March Type of sensor connection

3000W Programmable Single Output AEK AEK AEK AEK

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

InCos-P Pressure sensor 20 Pa Pa

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

LED Driver Linear / area fixed output

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AMU1-CHD+MK2 AUDIO MONITORING UNIT

-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

Series AM20EW-NZ 20 Watt DC-DC Converter

BSL Hardware Guide for MP35 and MP30-1 -

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Snaptec Australia Pty. Ltd.

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

RoHS. High shaft load capacity. Shock / vibration resistant

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

SCC-AO10 Isolated Analog Output Module

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

LED Driver Linear / area fixed output

Mini Digital Multimeter

PSC600-series DC/DC W

RS-485 I/O Modules: ADAM-4000

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

LED Driver Linear / area fixed output

DIAS Interface Module VARAN DIV 511

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Autoranging True RMS Multimeter User Manual

Electronic. Smart Testing Series

MINI MCR-SL-PT100-UI(-SP)(-NC)

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Digital input modules

Inductive Proximity Sensor

Transcription:

Power Supply for IT/ITN ULTRASTAB transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±10 V voltage output Six individual channels with 9-pin D-sub female connector for IT/ITN transducers Safety standard laboratory banana output jacks 19 rack mountable cabinet. Special features Universal mains input (100 240 V rms, 50/60 Hz) 15-pin male connector for access to status signals for all six channels LED indicators showing operational status of unit and of each individual channel ( Operational, Not operational, Not connected ). Advantages Applications Laboratory setup Industrial test bench Analogue current measurement frontend for multi-input power analyser, eg. for 3-phase measurements on AC motors, power inverters etc. Standards IEC 61010-1: 2001 IEC 61000-6-2: 2005 IEC 61000-6-4 : 2007. Application Domain Laboratory and Industrial. Convenient solution when operating 1 to 6 IT/ITN transducers in one setup Integrates in standard 19 rack system typically used in laboratory and industrial test setups The output current version allows measurement signal to travel long distances by using external burden resistor, i.e., current-to-voltage conversion is done by a precision resistor in attached measurement system (eg.: Power Analyser, etc.). N 88.92.98.000.0. Page 1/7

Mains INPUT Parameter Symbol Unit Value Mains supply voltage V rms 100 240 1) Fuse rating AT 2.5 Rated power supply frequency f Hz 50/60 Power consumption P C W < 150 2) Notes: 1) IEC-type dual fused inlet socket 2) All channels driven at max 1 A secondary output current. Transducer port Parameter Symbol Unit Value Comment Supply voltage U C V DC ±15 Ripple mv rms < 15 Noise mv rms < 15 Load regulation % < 5 Environmental and mechanical characteristics Parameter Symbol Unit Min Typ Max Comment Ambient operating temperature T A C 10 40 Ambient storage temperature T S C 20 85 Relative humidity RH % 20 80 Dimensions mm 483 88 290 W H D Mass m kg 4.2 Page 2/7

Electrical data - status port Parameter Symbol Unit Min Typ Max Comment Collector-Emitter voltage, off-state V CE off V 4 45 Collector-Emitter current, on-state I CE ma 2 30 Reverse Collector-Emitter voltage, off-state V CER off V 5 Collector-Emitter voltage, on-state V CE on V 0.2 1 1) 0.8 1 2) Notes: 1) Conditions: see diagram A on page 5 2) Conditions: see diagram B on page 5. Insulation characteristics Insulation voltage between rack electronics and status port connections: 3 kv rms. Page 3/7

Compatibility chart The IST ULTRASTAB supports the products (transducers), which are shown in the table below: Current range Products 60 A IT 60-S, IT 65-S 200 A IT 200-S, IT 205-S 400 A IT 400-S, IT 405-S 600 A IT 605-S, ITN 600-S 700 A IT 700-S 900 A ITN 900-S 1000 A IT 1000-S/SP1, ITN 1000-S Transducer connector 1 to 6: The pinout for the transducer connector 9-pin female, located on the back panel of the IST ULTRASTAB, is shown in the table below: Pin 1: Output current return Pin 2: N/C 5 1 Pin 3: Ground Pin 4: Ground Pin 5: Negative supply - 15 V Pin 6: Output current 9 6 Pin 7: N/C Pin 8: Normal operation Pin 9: Positive supply + 15 V 9-pin female UNC 4-40 screw lock Banana jacks output terminals 1 to 6: Two Banana jacks, located on the back panel of the IST ULTRASTAB, allow the connection of the secondary current outputs or the ± 10 V voltage outputs to the measurement device. Red: Current output or ±10 V voltage output depending on IST version. In current output case, this terminal is connected directly to pin 6 of the corresponding transducer port Black: Current output return or ±10 V signal ground. In current output case, this terminal is connected directly to pin 1 of the corresponding transducer port - Out + Page 4/7

Status/Interlock connector IST ULTRASTAB All IT/ITN ULTRASTAB transducers attached to the IST ULTRASTAB generate a status signal, which provides information about the operation of the transducer. This signal is routed through a photocoupler in the IST ULTRASTAB and available in one 15-pin male connector containing status signals for 6 channels. Power Status: Pin 1 Collector & Pin 5 Emitter Channel 1: Pin 9 Collector & Pin 13 Emitter Channel 2: Pin 2 Collector & Pin 6 Emitter Channel 3: Pin 10 Collector & Pin 14 Emitter Channel 4: Pin 3 Collector & Pin 7 Emitter Channel 5: Pin 11 Collector & Pin 15 Emitter Channel 6: Pin 4 Collector & Pin 8 Emitter 1 8 9 15 15-pin male UNC 4-40 screw lock All signals on the status/interlock connector are optically isolated, photocouplers type, floating Collector and Emitter. Status/Interlock port Wiring Diagram A: Active Low Output R UC : 4.. +45V DC Power Supply ICE max: 30 ma ICE min: 2 ma The photocoupler is driven by the transducer attached to the corresponding 9-pin connector ON : Transducer is OK (Normal Operation) OFF : Transducer is not OK Collector Emitter VOUT R min (kω) = 30 ma R max (kω) = 2 ma IST ULTRASTAB Rack USER SIDE Diagram B: Active High Output UC : 4.. +45V DC Power Supply The photocoupler is driven by the transducer attached to the corresponding 9-pin connector Collector ON : Transducer is OK (Normal Operation) OFF : Transducer is not OK Emitter VOUT ICE max: 30 ma ICE min: 2 ma R R min (kω) = 30 ma IST ULTRASTAB Rack R max (kω) = USER SIDE 2 ma In the diagram A, the active low output signal V out switches to GND when the corresponding transducer is OK (Normal operation and Green LED is lit). In the same manner, the transistor is switched off (No current from collector to emitter) to indicate that the corresponding transducer is not OK. Consequently, V out switches to U C and the corresponding Green LED is OFF, whereas the corresponding Red LED is lit. In the diagram B, the active high output signal V out switches to U C when the corresponding transducer is OK (Normal operation and Green LED is lit). In the same manner, the transistor is switched off (No current from collector to emitter) to indicate that the corresponding transducer is not OK. Consequently, V out switches to GND and the corresponding Green LED is OFF, whereas the corresponding Red LED is lit. The power supply voltage U C must be between 4 V and 45 V DC and the resistor value R must be chosen between a minimum value R min and a maximum value R max. Page 5/7

Some recommended standard values of R are given in the following table: Power supply voltage U C R min (kω) R max (kω) R standard values ± 5 % 5 V 0.153 2.3 180 Ω, 1 kω or 2.2 kω 12 V 0.386 5.8 470 Ω, 2.2 kω or 4.7 kω 24 V 0.786 11.8 1 kω, 2.2 kω or 10 kω FRONT PANEL INDICATOR PANEL The illuminated indicator panel has seven fields that are lit in the following modes: POWER: Green light - mains power is applied. No light - Unit is in off-state. CHANNEL 1 to 6: Green light - Indicated transducer is attached and normal operation signal is OK. Transducer is operational. Red light - Indicated transducer is attached and normal operation signal is not OK. No light - No transducer is connected. BACK PANEL Page 6/7

CONNECTING THE TRANSDUCERS IST ULTRASTAB The IST ULTRASTAB rack provides 6 connectors (9-pin ) on the back panel for connecting up to 6 IT/ITN individual transducers. Each 9-pin connector is used to connect the supply voltage to the DC power input of the transducer. It also routes the secondary current lines and the status signal from the transducer to the IST ULTRASTAB unit. Connect the transducers at the 9-pin connectors on the IST ULTRASTAB back panel via the shielded connection cables which have to be ordered separately. The shielded connection cable for operating a transducer is shown in the following figure: Available in two different lengths: 6 meters and 10 meters 9-pin male with metal housing Shielded connection cable 9-pin female with metal housing Plugs into 9-pin female on IST ULTRASTAB back panel Plugs into 9-pin male on transducer Connecting a transducer to IST ULTRASTAB The following 2 shielded connection cables are available: Description Order number Shielded connection cable length = 6 meters 71.12.08.000.0 Shielded connection cable length = 10 meters 71.12.13.000.0 It is recommended to use the connection cables indicated above. It is also possible to configure your own cable, bearing the following description in mind. The connection cable wiring is shown below: Metal housing: shield Metal housing: shield 9-pin male 1 3 4 5 6 8 9 1 3 4 5 6 8 9 9-pin female 9-pin Cable shield must be connected to the 9-pin housing at both ends female Transducer to IST ULTRASTAB connection cable wiring To prevent any malfunction that may occur due to the cable/wire voltage drop (i.e., its length and the wire resistance inside the cable) between the IST ULTRASTAB rack and the transducer, a cable with at least 7 wires, each having a cross section AWG 22, AWG 23 or 0.25 mm², must be used. In addition, it is recommended to use shielded cables in order to limit the effects of noise due to electromagnetic interference (EMI). Page 7/7