Agilent GC, MS, and ALS

Similar documents
Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

5973N and 5973 inert Mass Selective Detector

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Agilent Intuvo 9000 Gas Chromatograph

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. Agilent 6230B Series TOF LC-MS System Installation Checklist

Quick Reference. 5973N and 5973 inert Mass Selective Detector Local Control Panel (LCP)

Agilent G1732AA MSD Security ChemStation

Agilent 7890 Series Gas Chromatograph

Agilent G1701DA MSD ChemStation

Customers should provide all necessary operating supplies upon request of the engineer.

Agilent MassHunter GCMS Data Acquisition for the 5977 Series MSD System

Thermal Diffusivity Instruments DLF-2 with EM-1600

5973N and 5973 inert Mass Selective Detectors

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

Agilent G2070BA GC ChemStation

Agilent 7890B Gas Chromatograph

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

Agilent 5977 MSD Overview

Agilent G1732AA MSD Security ChemStation

Agilent 5975 Series MSD

Quick Start Guide and Health and Safety Information

5975 Series Mass Selective Detectors

Agilent 7820A Gas Chromatograph

Agilent GC/MSD Instructions

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

Micro GC Fusion Quick Start Guide

5973 Network Mass Selective Detectors

FOX-50 Heat Flow Meter

Agilent 6100 Series Quad LC/MS System

Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

Agilent 7890B Gas Chromatograph

5975 inert MSD. Chris Sandy European GC-MS Product Specialist Agilent Technologies

Agilent G1732BA MSD Security ChemStation

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

UNITY 2 TM. With ULTRA (50:50) & Air Server Series 2. Version 1.2. September 2012

Installation and Operation Differences. G2570A GC/MSD System

How to Run the CASPiE GCMS

Getting Started. Environmental Analysis Software

Rosemount 370XA Natural Gas Chromatograph

SIM Direct Inlet Probe. Agilent 5975 MSD. Agilent 7000 Triple Quadrupole

Agilent 6400 Series. System. Installation Guide. Agilent Technologies

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

SPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry

CTC Sampler Implementation in the GC/MSD ChemStation. Technical Overview. Introduction

The minimum version of Microsoft's Internet Explorer is version If you need to upgrade, install version 6.0, service pack 1.

Agilent G1978B Multimode Source for 6100 Series Single Quad LC/MS

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments

Z-350 FAZER USER MANUAL

Getting Started Manual

Gas Cooling Accessory

VOYAGER PUMP DOWN PROCEDURE (BENCH-TOP MODELS)

Agilent G1978A Multimode Source for G1946/G1956 LC/MSD

GC-MS ChemStation Reference Guide. Last Updated July 2014

D Issue D Original. Instruction Manual. Micro Tool Interface

Customer Responsibilities

Introduction to the HPLC ChemStation and Acquisition

Agilent 6400 Series Triple Quadrupole LC/MS System

Standard Operating Procedure

Model VDL 115 Vacuum drying chambers for flammable solvents

NDIR Infrared Gas Analyzer

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

System Installation Manual. HP 1100 Series LC/MSD

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Customer Responsibilities

S-100X / S-200X Snow Machine User Manual

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

Customer Responsibilities

Installation Note for Isocratic-to- Quaternary Pump Upgrade Kit G1352A

Warning 101 Invalid heater power for front detector, inlet, and aux 1 Warning 102 Invalid heater power for back detector, inlet, and aux 2

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

MICRONETICS. Test Solutions Group. Carrier - to - Noise Generator Operating Manual VOLUME 3: Service and Field Calibration

UNITY 2 TM. MFC Series 2 Installation Manual. Version 1.6 (Changes: Sections 1,2.1, 2.2, 3 & 4) June 2009

Steps for LCMS-8040 Triple Quadrupole

The Agilent 5975 inert MSD: New Tools for the Forensic Analyst

Instrument Network (INET) or Local Area Network (LAN) Communications Interface Board Installation Guide

CryoFocus-4 GC Cryogenic Trap

TA Instruments Installation Requirements for Microcalorimeter Systems

120Ra-1 Pentium III Processor Installation Insert

ZEPHYR Compact Haze Machine

Installing the Cisco MDS 9020 Fabric Switch

Junos WebApp Secure 5.0 Hardware Guide

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Removal and Installation8

Evolution 4300 Dissolution Sampler. Operation Manual

MT1810A 4 Slot Chassis Operation Manual

Waters 600E Multisolvent Delivery System Quick Start Guide

SHUR/Dry Slide Dryer III Catalog # SD-III-120 or Operator s Manual Version 1.0, May 2011

Accessories for

Agilent G1978A Multimode for 6210/6220 TOF

Moving your printer 1. Remove cables. Printing Moving the printer. Using color. Paper handling. 1 Turn the printer off. Maintenance.

400-DS Apparatus 7. Operator s Manual Original Instructions

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

9 Maintenance and Repair

885 Compact Oven SC. Manual EN /

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

VJ-1618 INSTALLATION MANUAL

Transcription:

Installation Checklist Verify Site Preparation for Your GC, GC/MS, and ALS 2 GC and MS Installation 2 Automatic Liquid Sampler (ALS) Installation 6 Acquisition Software and PC Installation 7 Performance Verification (5975 and 5977 Series if applicable) 7 This checklist is designed to help you correctly install your GC, 5975 MSD, 5977 MSD, 7000 Triple Quad GC/MS, or 7200 Accurate-Mass Q-TOF MS (referred to as MS in this document) and ALS, and have them function properly in your facility. Correct installation is the first step to operate your instruments and system reliably over an extended time. Make sure that necessary operating supplies, fittings, consumables, and usage-dependent items such as vials, syringes, and solvents are available before beginning installation. Agilent Technologies

Verify Site Preparation for Your GC, GC/MS, and ALS Adequate space available Suitable supporting bench CAUTION The supporting surface for the 7200 Q-TOF GC/MS system should be kept relatively vibration free. Vibration can lead to a loss of mass accuracy and resolution. GC and MS Installation Adequate electrical power available at the correct voltages and frequencies Environmental control systems adequate to maintain a correct, stable operating environment Adequate safe exhaust venting preparations Necessary supplies for instrument operation are available, including solvents, carrier and reagent gases for performance verification, and printer paper Computer as required for your instrument Verify shipped materials are unpacked and inspected MS installation Unpack and verify condition and completeness of shipment with shipping documents. Check serial numbers and fill in installation documentation serial number fields if necessary. 2 Installation Checklist

Place MS on bench. CAUTION The supporting surface for the 7200 Q-TOF GC/MS system should be kept relatively vibration free. Do not put the rough pump on your laboratory bench with the 7200 Q-TOF GC/MS due to the vibration that the pump creates. Vibration can lead to a loss of mass accuracy and resolution. Place the foreline pump on the floor or on the bench. Open MS top cover. (597x series MS only) Prepare MS and standard or dry foreline pump. Remove diffusion pump cap from MS (5975B VL MSD and 5977 DIFF MSDs only). Vent the MS. Install G3397A High Vacuum Gauge Controller (required for 5975 and 5977 Series CI MSDs). Prepare and connect reagent gas lines to MS (CI MSDs). WARNING The use of hydrogen is specifically prohibited with the 7200 Q-TOF MS. When using hydrogen as a carrier gas, remove and store the plastic cover over the window on the front of the MS. (5975 and 5977 Series only) Connect the GC s collision gas EPC module s line to the analyzer. (7000 GC/MS and 7200 Q-TOF MS). Connect the IRM helium line to the analyzer. (7200 Q-TOF MS). Place the 7200 Q-TOF alignment tool on the bench. Installation Checklist 3

GC Installation Unpack and verify condition and completeness of shipment with shipping documents. Check serial numbers and fill in installation documentation serial number fields if necessary. Check voltage settings of the instrument and computer systems. Verify that power cables are correct (must correspond with power socket). Verify line voltage and voltage settings. Place GC drawer stand on benchtop. (7000 and 7200 GC/MS only) Place the GC on the bench or mounting platform. WARNING The use of hydrogen is specifically prohibited with the 7200 Q-TOF MS. If using hydrogen as a carrier gas, remove the large round plastic cover for the MSD transfer line in the left side panel (7890A GC/MS only). Connect supply gases/traps (if ordered). Verify gas purity. Leak check all connections and purge the gas lines. Connect cryogenic coolant (if included). Plug in power cable. Connect the signal output and/or remote cables (if applicable). Turn on GC power. Set up LAN for use with data system. Configure the IP address if required for data system. Install test column to inlet and condition. Configure the GC time and date, devices, columns, gases, etc. Install the other end of the column. Check out the GC/ALS system using the checkout conditions and sample (use the Agilent Instrument Utility as applicable). 4 Installation Checklist

Connect the MS to the GC Turn off GC power. Align hole in GC left cover to use for back position. Align GC on alignment tool (7200 Q-TOF MS). Connect GC/MS interface heater cable. Position MS with interface in GC oven. Connect remote cable between the GC and the MS. Plug in the MS. Loosen sideplate thumbscrews completely and open analyzer door to view column end (5975, 5977 and 7000 MS only). Install column in the GC/MS interface. Connect standard or dry foreline pump and AC supply power cords to the MS. Turn on GC power. Turn off transfer line heater. Set GC carrier gas flow to 1.0 ml/min with constant flow enabled. Turn on MS power (press on the sideplate(s) ). Verify standard or dry foreline pump and front fan operation. Verify foreline pump stops gurgling within 60 seconds (standard pump). Verify turbo pump stops whining within 4 minutes (5975 and 5977 inert series, 7000 GC/MS, and 7200 Q-TOF MS only). Verify diffusion pump heater turns on (5975B VL MS and 5977 DIFF MS only). Verify MS does not turn off after 10 minutes of pumping down. Turn off GC heated zones. Installation Checklist 5

Automatic Liquid Sampler (ALS) Installation Unpack and verify condition and completeness of shipment with shipping documents. Check serial numbers and fill in installation documentation serial number fields if necessary. Install the ALS hardware on the GC: Prepare the GC. Install the tray, if applicable. Install injector mounting post and injector. Connect the injector and tray cables, if applicable. Connect to the controlling device. Turn on GC power. Install the tray vial racks, if applicable. If a tray is not installed, install the standalone sample turret. Configure the ALS on the GC and data system. Calibrate the tray, then the ALS system. Perform a dry run to verify the functionality of the instruments: Cap three sample vials. Place the sample vials in sample positions 1, 2, and 3. Place the solvent and waste vials in position. Install the syringe. Prepare the GC and controlling device. Start the sequence. 6 Installation Checklist

Acquisition Software and PC Installation Install PC and printer as needed. Create system LAN as needed. Install/upgrade software and configure. Install the user documentation on PC (if applicable). Install Agilent Instrument Utilities on the PC. Performance Verification (5975 and 5977 Series if applicable) Perform Checkout Tune. Perform Tune Verification. Perform Sensitivity Check verification of EI Sensitivity performance. Switch CI MS to CI operating mode. Verify PCI performance. Perform PCI autotune. Verify PCI sensitivity. Verify NCI performance. Installation Checklist 7

Agilent Technologies First Edition February 2013 This information is subject to change without notice. Agilent Technologies, Inc. 2013 Printed in U.S.A., February 2013 G3870-90001