INTECONT PLUS for Measuring Systems

Similar documents
INTECONT Tersus Mass flow rate measurement

DISOMAT T Weigh Transmitter

DISOVIEW E - The Legal-for-trade Scale Window for Windows PCs

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Presented By. NicolScales.com Contact Us

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

CHP GAS MONITOR GDR 1404

Quality knows no compromise

CHP GAS MONITOR GDR 1404

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

The wireless way to your scale Bluetooth radio modules

NF760 Batch Controller

Maxxis 4 Process Controller with BASIC Application

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Intrinsically safe batch controller Batching Master 110i

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

MID approval no. DE-08-MI004-PTB004 Date of release

EU Type Examination Certificate

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

MIC-2 Multi-instrument DATA SHEET

A2000 Multifunctional Power Meter

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Compact Speed Monitoring and Overspeed Protection System

CONFIGURABLE SAFETY RELAYS

Flow simulation system PROline FieldCheck

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

STANDARD TERMINAL. Digital Indicators. Product Number 3020

KS 3012 PMA GENERAL DESCRIPTION

Compact Universal Controllers

Weighing Electronics SIWAREX - PLC-based weighing electronics

Flowmeter for Mass Flow Rate Measurement

VEGA II. Electronic counter. The solutions that count

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Flow Measurement SITRANS F C

Business. Republic of SEWHACNM to the world beyond. 1 2 Industrial Automation

SX90 Process Controller

Comprehensive Modular Genset Controller

SIMOREG 6RA70 DC MASTER SIMOREG CM

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

PHOENIX CONTACT Features

Programmable Relay ZEN V2 Units

DD2050 Hopper Scale. datasheet

Compact universal controllers

FAX

Digital weighing terminal DWT 800

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Flow Measurement SITRANS F C

Signum Complete Scale Advanced SIWABBP SIWADCP SIWAEDG

LAUREL ELECTRONICS, INC.

C-Flow Coriolis Mass Flow Meter

RA33. Technical Information. Batch controller For the batching and dosing of mass and volume

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

NF770 Temperature Compensation Liquid Flow Computer

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

For Transmission, Distribution and Machinery protection.

N420 R420 R423. series

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

LM10 to MM200 Retrofit

Product data sheet accessories control and regulation Accessories AIRWIN

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

PI-EX-ME-2NAM/COC-24VDC

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

General information. Display. Supply voltage. Input current

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

PowerFlex 400 AC Drive Guide Specification

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Weighing Indicator. Features. Description. Applications

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

LAUREL ELECTRONICS, INC.

CATALOG SELECTION / PRODUCT SELECTION

The safety control of the next generation

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

TECHNICAL DATA. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection.

Clear Benefits of the KRAL Electronic.

PUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C/41H measuring indicator...

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering.

General information. Display. Supply voltage

Signum Complete Scales Supreme Stainless Steel SIWSBBS and SIWSDCS

C500 Series Data Sheet

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

EC Type Examination Certificate

Displays Transducers. Displays and transducers

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Transcription:

INTECONT PLUS for Measuring Systems % Compact weighing electronics for continuous measuring systems % Integrated display and control panel % Optimal communication structures thanks to modular fieldbus technology % EasyServe PC program for convenient commissioning and service % Enhanced operating reliability through diagnostics and self-testing functions % High operating convenience, automatic calibration programs % Optional legal-for-trade variant Application The INTECONT PLUS weighing electronics is specially designed for weighing in continuous production processes. It is the right solution whenever material flows have to be measured and acquired with high accuracy with the use of % Belt weighers (MULTIBELT ) % Solids flow meters (MULTISTREAM ) % Coriolis mass flow meters (MULTICOR ) This also covers special applications, e.g. legal-for-trade weighing or use in the hazardous area. The INTECONT PLUS weighing electronics is primarily designed for applications with a need for convenient and elaborate display, control and monitoring, in addition to basic measuring functions. The weighing electronics ensures repeatability and transparency of the production process. Equipment The system is supplied as front panel mounting unit or with wall-mounting housing for local installation. Operation is via ergonomically styled keyboard organised into operating and service functions. A luminescent, anti-glare two-line display ensures easy reading of results. Equipped with appropriate communication module, INTECONT PLUS optimally fits into any automated environment. Operating Principle Although the INTECONT PLUS functions vary with every scale type, the basic equipment is always the same. % System accuracy for weighing tasks better than 0.05% % Manual and/or automatic zero setting % Full feed/dribble feed control for accurate batching % High electromagnetic compatibility % Galvanically isolated outputs % Totalizing counter pulses % Fail-safe data memory (EEPROM) % Integrated diagnostics and selftesting functions (SPC) % Default settings for simple and quick commissioning % Auto calibration (automatic calibration programs, self-starting taring) % Calibration intervals with signal output (selectable at will) % Dialog available in German, English, Italian, Spanish and French % Status, event, calibration and quantity reports % Simulation mode for testing and learning BV-D2184GB

Weighing functions As a function of mechanical system used, the actual feed rate is acquired using: % Belt load and belt speed (belt weighers) % Reactive force (solids flow meters) % Direct mass flow measurement on the Coriolis principle (mass flow meters) In addition to the comprehensive basic equipment, the following weighing functions are available: % Belt weighers - Accurate belt speed measurement - Belt influence compensation (BIC) - Belt run monitoring - Shifting of weighing to point of discharge - Legal-for-trade variant (upon request) % Solids Flow Meters - Adaption to varying measuring chute characteristics % Coriolis Mass Flow Meters - Accurate speed and torque acquisition Dimensions (mm) INTECONT PLUS for Front Panel Mounting INTECONT PLUS Wall Housing Belt Weighers, Solids Flow Meters Panel cut-out 282 + 0,5 x 88 + 0,5 INTECONT PLUS Wall Housing Coriolis Mass Flow Meters Bottom View

Technical Data Base Unit Display Power supply Clear text fluorescent display, 2 lines with 20 digits each, 6 mm character height 24 VDC +30% / -25% Consumption 20 VA Ambient conditions Operating temperature -40 to 60 C EMC (EN 61000, EN61326) conform to CE regulations Legal-for-trade application: Temperature range -10 to +40 C Front panel mounting housing Protection Front protected to IP 65 Measuring inputs Speed (RPM) input (NAMUR level 0.04-3000 Hz) Load cell input (R min 80 Ω, up to 1000 m cable) Release contact (24 V, 5 ma) Namur input for belt circuit sensor Control inputs 3 potential-free digital inputs (24 V, 5 ma) Outputs 3 relay outputs (max. 230 V, 8 A ohmic load, 1 A inductive load) 1 analog output (potential-free, 0(4)-20 ma, max. 11 V) 1 pulse output for totalizing counter (24 V / 100 ma) Interfaces Power supply measuring circuit RS 232 for Service PC 12 V AC Additional Equipment Wall housing for belt weighers, solids flow meters Wall housing for Coriolis mass flow meters with control unit and power switch Power supply, 85... 264 V Power supply, 85... 264 V Analog display Pulse counter, non-resettable Pulse counter, resettable Event printer Special measuring cable Legal-for-trade memory Wall housing IP 54 (Nema 4) Power supply 85.. 264 V/ 24 V Wall housing IP 54 (Nema 4) Power supply 85.. 264 V /24 V Control unit and power switch 24 V, 2 A, panel-mounting unit 24 V, 1,25 A, desk-top unit 0-100%, panel-mounting unit 4-20 ma, 96mm x 24 mm 8-digit 52 mm x 28 mm 6-digit 52 mm x 28 mm printer with serial interface RS 232 and system cable Indicate length in your order MEMOSAVE, see Datasheet BV-D 2078GB I / 0 Expansion (Option) 2 potential-free digital inputs Control inputs (24 V / 5 ma) Outputs 5 relay outputs (max. 230 V, 8 A ohmic load, 1 A inductive load) 1 analog output (potential-free, 0(4)-20 ma, max. 11 V) Interfaces RS 232 for printer Communication Modules (Option) Model VSS 021 V VPB 020 V VCB 020 V VET 020 V VET 022 V Modbus, 3964 R Profibus DP Device Net Ethernet MODBUS/TCP Ethernet/IP

INTECONT Variant VEG 206XY X = 0 : No I/0 expansion = 1 : With I/0 expansion Y = 0 : No communication module Y = 1 : Communication module Modbus, 3964 R Y = 2 : Communication module Profibus DP Y = 3 : Communication module Device Net Y = 4 : Communication module Ethernet MODBUS/TCP Schenck Process GmbH Pallaswiesenstr. 100 64293 Darmstadt, Germany Phone: +49 6151 1531-1216 Fax: +49 6151 1531-1172 sales@schenckprocess.com www.schenckprocess.com Options Wall housing with power supply for belt weighers and solids flow meters Wall housing with power supply, control unit and power switch, for Coriolis mass flow meters Power supply: desk-top, panel-mounting units Analog display Pulse counter, non-resettable Pulse counter, resettable Event printer BV-D2184GB 0903 All information is given without obligation. All specifications are subject to change. by Schenck Process GmbH, 2009

INTECONT PLUS for Feeding Systems % Compact measuring, control, and supervisory electronics for continuous feed applications % Integrated display and control panel % Optimal communication structures thanks to modular fieldbus technology % EasyServe PC program for convenient commissioning and service % Enhanced operating reliability through diagnostics and self-testing functions % High operating convenience, automatic calibration programs Application Designed for feeding duties in continuous processes, the INTECONT PLUS measuring, control, and supervisory electronics is specially suited for single feeders and small gangs controlled by a host system. The system is the right choice whenever bulk solids have to be fed with high accuracy with the use of % belt weighers (MULTIBELT or weigh belts with controlled prefeeders % weighfeeders (MULTIDOS ) % Coriolis mass flow feeders (MULTICOR ) % loss-in-weight feeders (discharge and fill weighing with MECHATRON / AccuRate) without expensive control of the feeder environment. The system can also be used in special applications, i.e. in the hazardous area. The measuring, control, and supervisory electronics is specially economical if the feed system is controlled locally in normal mode or from the display and control panel in a central control room. Equipment The electronics is supplied as front-ofpanel mounting unit or with an optional wall-mounting housing for installation at site. The system is operated via an ergonomically styled keyboard organised into operating and service functions. A luminescent, anti-glare two-line display ensures easy reading of results. Equipped with appropriate communication module, INTECONT PLUS optimally fits into any automated environment. Operating Principle Although the INTECONT PLUS functions vary with every scale type, the basic equipment is always the same. % System accuracy for weighing tasks better than 0.05% % Precise speed acquisition % Optimal feed control for accurate batching via an adaptive control circuit % High electromagnetic compatibility % Galvanically isolated outputs % Fail-safe data memory (EEPROM) % Integrated diagnostics and selftesting % functions (SPC) % Preset with default values for easy and quick commissioning % AUTO calibration (automatic calibration programs), theoretical span calibration without auxiliaries % Totalising pulse (level and pulse width set by parameter) % Simulation mode for testing and learning % Status, event, calibration and quantity reports Dialog in German, English, Italian, Spanish and French. BV-D2185GB

Weighing Functions The difference of set and actual feed rates, determined by comparison, forms the control output to the feeder control circuits. As a function of feeder type, a corresponding control signal is transferred to the speedcontrolled weigh belt, the controllable discharge unit of the loss-in-weight feeder or the controllable feed unit of the Coriolis mass flow feeder. The control circuit exactly controls the actual feed rate for setpoint. The actual feed rate is acquired using: % Measured variables, i.e. belt speed and belt load with weighfeeders % Loss in weight in the hopper per unit time with loss-in-weight feeders % Direct mass flow measurement on the Coriolis principle (mass flow feeders) In addition to the comprehensive basic equipment, the following weighing functions are available: % Weighfeeders - Control for point of discharge - Automatic belt run monitoring (belt slip, belt skew) - Belt influence compensation (BIC) % Loss-in-weight feeders - Adaptive fuzzy disturbance auto elimination - Fill control as a function of time and/or weight - Adaptive control adjustment to material properties % Coriolis mass flow feeders - Manual and automatic zero setting - Prefeeder control Dimensions (mm) INTECONT PLUS for Front-of-Panel Mounting Wall-mounting Housing Selected in accordance with frequency inverter output and design Panel cut-out 282 + 0.5 x 88 + 0.5 Cable inlet 300

Technical Data Base Unit Clear text fluorescent display, Display 2 lines with 20 digits each, 6 mm character height 24 VDC +30% / -25% Power supply Consumption 20 VA Ambient conditions Operating temperature -40 C to 60 C Humidity Class F (DIN 40040) EMC (OIML, IEC 801, EN 45501) Spark protection (EN 55011, VDE 871-B) conform to CE regulations Front-of-panel mounting housing Protection Front protected to IP 65 Measuring inputs Speed (RPM) input (NAMUR level 0.04-3000 Hz) Load cell input (R min 80 Ω) Analog input, galvanically non-isolated for external setpoint 0(4)-20mA) Belt circuit pulse (NAMUR level) Control inputs 3 potential-free digital inputs (24 V, 5 ma) Outputs 3 relay outputs (max. 230 V, 8 A ohmic load, 1 A inductive load) 1 analog output (potential-free, 0(4)-20 ma, max. 11 V) 1 pulse output for totalising counter (24 V / 100 ma) Interfaces I / 0 Expansion (Option) RS-232 for Service PC 2 potential-free digital inputs Control inputs (24 V / 5 ma) Outputs 5 relay outputs (max. 230 V, 8 A ohmic load, 1 A inductive load) 1 analog output (potential-free, 0(4)-20 ma, max. 11 V) Interfaces RS-232 for printer Additional Equipment Control cubicles and racks Wall-mounting housing with drive unit and power supply for accommodation of INTECONT PLUS Power supply, 85... 264 V Power supply, 85... 264 V Local control unit Analog display Pulse counter, non-resettable Pulse counter, resettable Event printer DC isolator Emergency Stop switch Special Scale / Weighing Electronics interconnecting cable Control cubicles and racks for accommodation of several INTECONT PLUS with or without power supply 600 mm x 600 mm x 2000 mm 800 mm x 400 mm x 2000 mm Wall-mounting housing protected to IP 54 (Nema 4) for drive units and power supply 230V / 400V (see figure) 24 V, 2 A, panel-mounting unit 24 V, 1,25 A, desk-top unit Local/Automatic modes, Start/Stop, speed setpoint 0-100%, panel-mounting unit 4-20 ma, 96mm x 24 mm 8-digit 52 mm x 28 mm 6-digit 52 mm x 28 mm dot matrix printer with serial interface RS-232 (V 24) and system cable DC isolation amplifier for analog outputs Emergency Stop switch for max. 1.5 kw connected load Indicate length in your order Communication Modules (Option) Model VSS 021 V VPB 020 V VCB 020 V VET 020 V VET 022 V Modbus, 3964 R (S5) Profibus DP Device Net Ethernet MODBUS/TCP Ethernet/IP

Variants VEG 206XY X = 0 : No I/0 expansion = 1 : With I/0 expansion Y = 0 : No communication module Y = 1 : Communication module Modbus, 3964 R Y = 2 : Communication module Profibus DP Y = 3 : Communication module Device Net Y = 4 : Communication module Ethernet MODBUS/TCP Y = 5 : Communication module Ethernet/IP Schenck Process GmbH Pallaswiesenstr. 100 64293 Darmstadt, Germany T +49 6151 1531-1216 F +49 6151 1531-1172 sales@schenckprocess.com www.schenckprocess.com Options Control cubicles or racks with/without power supply for max. 2 INTECONT PLUS Wall-mounting housing with drive units up to 3 kw and power supply Power supply: desk-top, panel-mounting units Local control unit Analog display Pulse counter, non-resettable Pulse counter, resettable Event printer DC isolator Emergency Stop switch BV-D2185GB 0809.1 All information is given without obligation. All specifications are subject to change. by Schenck Process GmbH, 2008