Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Similar documents
Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Operating instructions ClassicLine module AC / / 2012

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Quick reference guide 3D sensor O3D3xx

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Operating instructions. Speed monitor D / / 2014

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Binary level sensor LMC / / 2014

Operating instructions Photoelectric distance sensor OGD592 OGD593

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Electronic temperature sensor TN /00 04/2011

Operating instructions Optical distance sensor O1D / / 2008

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions Optical distance sensor O1D / / 2012

Installation instructions Ethernet switch EC / / 2011

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions Electronic pressure sensor PN7xxx

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Operating instructions AC010S Compact AS-i E-STOP safety module

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

Operating instructions Memory plug E /02 11/2011

AS-i 3.0 Motor modules

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Digital Modules AS-i in IP20, 22,5 mm

AS-i Safety Output Module, IP20

Operating instructions Electronic temperature sensor TN7511

Operating instructions Programming and display unit PP / / 2010

Please keep these instructions for further reference.

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Operating instructions RFID evaluation unit DTE / / 2011

Operating instructions. Standstill monitor A / / 2011

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module

Analog Modules AS-i, IP67, M12

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

Operating instructions. Monitor FS-2 / FS-2N / / 2013

System manual AS-i safety monitor AC041S /00 05/2013

Assembly and Operating Instructions Door Control

Please keep these instructions for further reference.

Operating Manual FPGA-based High-Speed Micro-PLC

Operating instructions Binary level sensor LMTx0x LMTx1x LMTx2x

B63/ NS MS. EtherNet/IP LINK

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Operating instructions Control monitor for temperature sensors TR7439

AS-i Safety Relay Output Module with Diagnostic Slave

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

InView Marquee Message Display

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Handbuch Manual Manuel MASI20

6173 AG GJB A0138

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

MILLENIUM MASI INSTALLATION MANUAL NTR 748 / E. Simple Automation Control Module (MAS)

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Operating instructions Pressure sensor. PE30xx / / 2010

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Operating instructions Pressure sensor. PN70xx / / 2012

AS-i Safety Relay Output Module with Diagnostic Slave

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

MINI MCR-SL-MUX-V8-FLK 16

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Transcription:

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015

Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions and features...3 4 Installation...4 5 Operating and display elements...9 6 Addressing...9 6.1 Addressing with the AC1154 addressing unit...9 7 Electrical connection...14 8 Operation...15 9 Technical data...15 2

1 Preliminary note An instruction is indicated by : Example: Mount the unit as shown. A reaction to the action is indicated by > : Example: > yellow LED lights. Important note Non-compliance can result in malfunction or interference. Information Supplementary note. 2 Safety instructions Please read the operating instructions prior to set-up of the device. Ensure that the product is suitable for your application without any restrictions. The unit conforms to the relevant regulations and EC directives. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. Installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. 3 Functions and features maximum number of modules per master: -- 31 (AC5205, AC5208, AC5211, AC5213) -- 62 (AC5203, AC5214, AC5215, AC5233, AC5294) AS-interface version 3.0, downward compatible 3

4 Installation Disconnect the system from power before installation. 1 Alignment of the flat cable on delivery Carefully place the yellow and optionally the black AS-i flat cable into the profile slot. 2 Mount the upper part. 3 Lock the unit. 4

With the supplied lower part the flat cable can be aligned in three directions. For the requested direction place the flat cable guide (1) accordingly. 5

A Settings at the lower part Select the position 1, 2 or 3 depending on the requested flat cable alignment ( ). A = factory setting B C 6

Settings at the upper part Then set the selected position at the upper part. To do so, turn the triangle to the corresponding number (fig. D1 and D2). D1 Use a tool, e.g. a screwdriver (figure D1) or the yellow / black flat cable guide (figure D2). D2 7

Open the unit Open the unit using a tool as shown (e.g. screwdriver). Take care in laying the AS-i flat cable, the flat cable should be laid straight for about 15 cm. 8

5 Operating and display elements 7 1 6 5 4 1: addressing interface 2: LED AUX 3: 4 M12 sockets 4: LED 2 5: LED 1 6: labels 7: LED PWR 6 Addressing The address is set to 0 at the factory. 3 2 6.1 Addressing with the AC1154 addressing unit When mounted and wired the module can be addressed with the addressing cable (E70213) via the integrated addressing interface. If a slave with the extended addressing mode (AC5203, AC5214, AC5215, AC5233, AC5294) is used in combination with a master of the first generation (version 2.0), the parameter P3 must be 1 and the output bit D3 must be 0*. The output bit D3 and the parameter bit P3 must not be used. * * default setting If a slave with the extended addressing mode is used in combination with a master of the first generation (version 2.0), an address between 1A and 31A must be assigned to this slave. 9

AC5203 3 outputs AS-i profile S-8.A.E / extended addressing mode: yes Output 1 2 3 - Socket O-1/2 O-1/2 O-2 O-3 - Y-circuit outputs - O1 O-1/2 O2 - O2 O-2 AC5205 4 inputs AS-i profile S-0.0.E / extended addressing mode: no Input I1 I2 I3 I4 Socket I-1 I-2 I-3 I-4 Inputs 2 1 + 10

AC5208 4 outputs AS-i profile S-8.0.E / extended addressing mode: no Output O1 O2 O3 O4 Socket O-1/2 O-1/2 O-2 O-3/4 O-3/4 O-4 Y-circuit outputs - O1 O-1/2 O2 - O3 O-3/4 O4 - O2 O-2 - O4 O-4 AC5211 2 inputs / 2 outputs (2 Ampère) AS-i profile S-3.0.E / extended addressing mode: no Input I1 I2 - - Socket I-1 I-2 - - Output - - O3 O4 Socket - - O-3/4 O-3/4 O-4 Inputs Y-circuit outputs - O3 O-3/4 O4 2 1 + - O4 O-4 11

AC5213 4 outputs (2 Ampère) AS-i profile S-8.0.E / extended addressing mode: no Output O1 O2 O3 O4 Socket O-1/2 O-1/2 O-2 O-3/4 O-3/4 O-4 Y-circuit outputs - O1 O-1/2 O2 - O3 O-3/4 O4 - - O2 O-2 O4 O-4 AC5214 2 outputs / 2 inputs AS-i profile S-B.A.E / extended addressing mode: yes Input - - I3 I4 Socket - - I-3/4 I-3/4 I-4 Output O1 O2 - - Socket O-1/2 O-1/2 O-2 - - Y-circuit inputs Y-circuit outputs - O1 O-1/2 O2 - O2 O-2 12

AC5215 4 inputs AS-i profile S-0.A.E / extended addressing mode: yes Input I1 I2 I3 I4 Socket I-1/2 I-1/2 I-2 I-3/4 I-3/4 I-4 Y-circuit inputs - I1 I-1/2 I2 + - I3 I-3/4 I4 + - I2 I-2 + - I4 I-4 + AC5233 4 outputs (2 Ampère) AS-i profile S-7.A.7 / extended addressing mode: yes Output O1 O2 O3 O4 Socket O-1/2 O-1/2 O-2 O-3/4 O-3/4 O-4 Y-circuit outputs - O1 O-1/2 O2 - O3 O-3/4 O4 - - O2 O-2 O4 O-4 13

AC5294 4 inputs AS-i profile S-0.A.E / extended addressing mode: yes Input I1 I2 I3 I4 Socket I-1 I-2 I-3 I-4 Inputs 2 1 + 7 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Disconnect power. Connect the unit. Connect the plugs of the sensors / actuators to the M12 sockets, tightening torque 0.6...0.8 Nm. Cover the unused sockets with protective caps (E73004)*, the addressing socket with the supplied protective cap. Tightening torque 0.6...0.8 Nm. To guarantee protection rating IP 67 you also have to use the flat cable end seal (E70413)* if the module is at the end of the cable line * to be ordered separately 14

8 Operation Avoid build-up of dirt and dust on the upper and lower parts so that the locking mechanism is not affected. LED 2 yellow: LED PWR green: LED AUX green: LED FAULT red lights: LED FAULT red flashes: LED 1 yellow: input / output switched AS-i voltage supply ok AUX voltage supply ok (AC5203, AC5208, AC5211, AC5213, AC5214, AC5233) AS-i communication error, slave does not participate in the normal exchange of data, e.g. slave address 0 peripheral fault, e.g. sensor supply / output overloaded or shorted logic state of the outputs Overload and short circuit of the input supply and the outputs are signalled as peripheral fault to the AS-i master (version 2.1 or higher). 9 Technical data Technical data and further information at www.ifm.com. 15