MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

Similar documents
Gelo LED Driver 100W, Single output RGLD100-24

Features. Applications and Benefits TRC ELECTRONICS, INC

TALON Network Manager- 2 & 6 Express

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Outdoor 25W Driver SL-LA US

Relay Panel. B l u e R i d g e T e c h n o l o g i e s

S025W-056C W Programmable LED Drivers

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Outdoor 200w Driver SL-L2282B002US

TU531, TU532 Terminal Unit

TF501, TF521 Terminal Bases

DC561, digital input/output module,

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Constant Voltage Mode

LED55WPG Programmable LED Driver

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

AO523 Analog Input Module

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

ASCO 920 Remote Control (RC) Switches

TECHNICAL DESCRIPTION

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

SL-LU US Type TL SL-LU US Class P

DC562, digital input/output module,

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

Multi-Point Gas Detection and Control System

CS XL XM. EcoSystem Bus Supply

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

RT12-240V/2.4kW Rectifier Specification

Installing the Tracer MP503 Input/Output Module Ordering number: ,

DI561 Digital Input Module

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

rcc.1081 Installation Instructions

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

APK INSTALLATION GUIDE

Safety Standards. Model Number:

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

920 Remote Control (RC) Switches

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

AI561 Analog Input Module

DX561 Digital Input/Output Module

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Installation & Operation Guide

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

DI572 Digital Input Module

Output Voltage* (nom.)(adjustable)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Output Voltage* (nom.)(adjustable)

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Redundancy unit CP-A RU

SAMSUNG ELECTRO-MECHANICS CO., LTD

TM3SAF. Main. Device short name

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Multi-Point Gas Detection and Control System

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

Multi-Point Gas Detection and Control System

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Cabinet Interface Device

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Digital ac/dc (24V) Input Module

INSTALLATION INSTRUCTIONS

Hi-lume Premier 0.1% EcoSystem LED Driver

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RT4F-110V/25A RECTIFIER

TM3AI4 module TM3-4 analog inputs

PanelView Plus/VersaView CE Terminals and Display Modules

Temperature. Power requirements. Weight. Dimensions

Room Controllers. SC3000 Relay Pack

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

SPECIFICATION. Model: PS3038. Redundant Power Supply With Active PFC 700W + 700W

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

SECTION ( ) LIGHTING CONTROL PANELBOARD

PDI Modular Compact Remote Power Panel

Transcription:

Data Sheet Lighting Relay Panel Overview Leverage the Power of BAS Integration Exterior with Surface Mount Trim The Series UL Listed, Lighting Control Panel provides the capability to control high voltage lighting circuits via a two-wire RS-485 network, occupancy sensors, light level sensors, momentary override switches, and other input devices. The standard Maxiom series panels have an extra capacity high-voltage compartment with ample space for the electrical contractor to add multi-pole contactors if desired. panels with Tru-lock feature cannot be opened without a key. Standard LTR relays have a manual override lever for operation of the relay without power to the electronics and each relay terminal block can accommodate up to size 8AW load wires. The standard panel sizes are based on relay capacity of 16, 32, and 48 relays. In addition, the mini panel has a capacity of only 8 relays and the MX60 extends the MX48 s interior relays chassis into the extra capacity area effectively using the space for 60 LTR relays. MX32 MX16 MX32 MX48 MX60 with LX5 technology integrates with most building automation systems; reducing frustration for the building engineer by eliminating the need to learn to operate and maintain a separate lighting control system. LX5 technology features native BACnet for MSTP and ARCnet, N2 direct, Apogee Open Processor direct, Lumisys, and Triatek Lighting open protocols. In addition, all panels have on-board DDN (Digital Device Network) communication to addressable switches. UL 916 CEC Title 24 Lumisys and are registered Trademarks 020209943CS Page 1 of 5 Interior with voltage separation removed MX08 _PW_DS.pdf

Specifications Native Communications Building Automation System Subnet Electrical Switch Inputs Analog Inputs Power Supply Relay Type Relay Rating Relay Terminals Dip switch selectable - BACnet MS/TP, N2, Lumisys Open, Triatek Legacy. Members of Lumisys Partner Program may offer additional native communication options. Transient protected two-wire differential signaling on a daisy-chain topology network. Two wires for communication & two wires for power. Belden # 1502P or equivalent. Software configurable switch input types Momentary two-wire ON / OFF alternating switch action Momentary ON two-wire or three wire ON only Momentary OFF three-wire OFF only Maintained two-wire, open = OFF closed = ON State Change two-wire ON / OFF alternating system action Jumper select for: dry contact or 12 to 24VDC external power. Six Analog Inputs (0-5 VDC) - typically used for Light Level Sensors (See Lumisys LS5 Sensors) Primary : 115/277 VAC, 30 VA, 60 Hz ± 10% (dual-tap) See Power Supply Wiring Secondary : 24VAC minimum ± 10% SPST latching with manual override lever, UL Recognized Component Tungsten 20 amp @ 277 VAC Ballast 20 amp @ 277 VAC Ballast 20 amp @ 347 VAC Resistive 20 amp @ 277 VAC Resistive 20 amp @ 347 VAC Each slotted screw box clamp terminal accepts #14 - #8 AW or two #10 AW. Solid or stranded wire, copper only Relay Drive Signal Staggered, energize pulse S.C.C.R. Short Circuit Current Rating - 20KA @277V Environmental Operating Temperature 32 to 125 F (0 to 50 C) Operating Humidity System Certification 20% - 95%RH, non-condensing Electronics meet or exceed IEC Level 3 standards: Radiated Emissions, IEC 55022, Class A Conducted Emissions, IEC 55022, Class A Quasi-Stationary Current Harmonics, IEC 6100-3-2 Voltage Fluctuation and Flicker, IEC 6100-3-2 Electrostatic Discharge, IEC 61000-4-2 Electrical Fast Transient/Burst, IEC 6100-4-4 Surge Immunity, IEC 6100-4-5 Immunity to Conducted Disturbance, IEC 6100-4-6 Immunity to Voltage Dips, Short Interruptions, Voltage Variations, IEC 6100-4-11 Electromagnetic Compatibility eneric Immunity Standard. Part 1, IEC 6100-6-1 ISO 9001 RoHS Compliant Mechanical Enclosure Type NEMA 1 Regulatory Electronic assemblies shall meet or exceed standards Underwriters Laboratories UL 916, Standard for Energy Management Equipment FCC, Part 15, Class A Radiated Emissions FCC, Part 15, Class A Conducted Emissions CEC Title 24 Lumisys and are registered Trademarks Page 2 of 5

Enclosure Dimensions Refer to Product Family Comparison Panel MX08 MX16 MX32 MX48 MX60 Dimensions (Width x Height x Depth) 13 x 16 x 4 18 x 25 x 18 x 33 3/4 x 18 x 42 1/2 x 18 x 42 1/2 x Contactor Mounting Space N/A 8.0 x 8.0 x 5.0 8.0 x 8.0 x 5.0 8.0 x 8.0 x 5.0 N/A Trim Style Screw on Tru-lock Tru-lock Tru-lock Tru-lock Controller Lx5 Lx5 Lx5 Lx5 Lx5 Flash Upgrade Yes Yes Yes Yes Yes Approximate Shipping Weight 20lbs 31lbs 44lbs 58lbs 70lbs Native Protocols Selectable via Dip Switch BACnet MS/TP Yes Yes Yes Yes Yes N2 Open Yes Yes Yes Yes Yes Lumisys Open Yes Yes Yes Yes Yes TRIATEK legacy Yes Yes Yes Yes Yes Other Protocol Options Lumisys Partners offer additional native communication options Inputs Digital Subnet for Switches and Occupancy Sensors Native Native Native Native Native Binary inputs available without option card 24 24 56 88 120 Analog Inputs available without option card 6 6 6 6 6 Optional Telephone Override Card No Yes Yes Yes Yes Outputs Relay Panel Capacity 8 16 32 48 60 Latching Relay with manual override on relay Warranty 24 months from date of shipment. Refer to Lumisys Terms and Conditions of Sale for additional details. Lumisys and are registered Trademarks Page 3 of 5

Ordering Information Ordering an MX08 Catalog # Description MX08PXX Series MX08 Lighting Control Panel - Factory assembled Number of Factory Installed Relays: Limited to relay capacity (8). 1 to 8 available. Ordering an MX16, MX32, MX48 or MX60 Catalog # Description MXXXIXX MXXXE MXXXTS Interior for Series Lighting Control Panel Number of Factory Installed Relays: Limited to Relay Capacity Selection below Relay Capacity Selection Options: 16, 32, 48 or 60 Relay Capacity Enclosure for Series Lighting Control Panel Relay Capacity Selection Options: 16, 32, 48 or 60 Relay Capacity Surface Mount Trim with Key Lock Trim Size Selection options: 16, 32, 48 or 60 (relates to relay capacity) NOTES The Relay Capacity selection for Interior, Enclosure and Trim need to match or the panel will not fit together properly. A correctly ordered MX16, MX32, MX48 or MX60 product will have all three components: Interior, Enclosure and Trim Example: Quantity Part# Description 1 MX32I27 Interior with 32 relay capacity and 27 relays factory installed 1 MX32E Enclosure with 32 relay capacity 1 MX32TS Surface mount trim for with 32 relay capacity enclosure Power Supply Wiring Blue Blue Fuse 24 VAC Yellow Brown White Fuse 277 VAC 24 VAC Yellow Brown White 120 VAC Relay Wiring Detail LTR Relay Hot Feed Switched Hot Load Neutral Network Architecture Belden # 8760 or equivalent BAS Belden # 1502P or equivalent Lumisys and are registered Trademarks Page 4 of 5

Switch 24V Power Connector 24 Belden # 1502P Signal Wires Network Input Module L H Common round Network Common 5V Power Analog Input Connector Signal Wires 5V A6 A5 A4 A3 A2 A1 Sensor 1 Signal A1 Common round 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 To Common round 2-wire switch momentary ON/ OFF 3-wire switch momentary ON/ OFF Lumisys and are registered Trademarks 2-wire switch maintained or state change Page 5 of 5